• Title/Summary/Keyword: Finger Scan

Search Result 22, Processing Time 0.024 seconds

A study on the Web Standard Modules (Non-ActiveX) based on Secure Banking Transactions (웹 표준 모듈(Non-ActiveX)기반 한 안전한 은행거래를 위한 연구)

  • Nam, Ki-Bok;Park, Koo-Rack;Kim, Jae-Woong;Lee, Yun-Yeol
    • Proceedings of the Korean Society of Computer Information Conference
    • /
    • 2016.07a
    • /
    • pp.243-244
    • /
    • 2016
  • 은행거래를 하려면 Active X를 기반으로 하는 보안 통합설치프로그램, 공인인증 보안프로그램, 개인 PC방화벽 프로그램 등 보안에 필요한 프로그램을 설치해야한다. 그러나 Active X의 보안취약점으로 앞으로 나올 브라우저에서는 Active X대신 웹 표준 모듈을 기반으로 하는 보안 시스템을 제공하고 있다. 본 논문은 Active X를 대체할 수 있는 것으로 웹 표준 모델에 근거한 QR코드 및 지문인식을 통한 인증을 제안한다. 본 논문에서 제안한 시스템을 적용한다면, 보다 안전한 은행거래를 하는데 도움을 줄 수 있다.

  • PDF

Synthesis of Hydroxypropyl Chitin and Its Liquid Crystalline Character (히드록시프로필 키틴의 합성과 액정형성)

  • Kim, Seon Jeong;Lee, Young Moo
    • Applied Chemistry for Engineering
    • /
    • v.3 no.3
    • /
    • pp.516-521
    • /
    • 1992
  • Hydroxypropyl chitin (HPCH) was prepared by reacting chitin with propylene oxide. HPCH showed the improved solubility in several organic solvents compared with chitin. It showed the remarkable solubility in formic acid. Form the results of polarized microscopic observatoin of HPCH solution in formic acid, finger-print pattern was observed in concentrations over 30 wt% solution. Since no typical thermogram was observed in DSC scan, the HPCH showed a lyotropic cholestric liquid crystallinity.

  • PDF

Hand-Gesture Recognition Using Concentric-Circle Expanding and Tracing Algorithm (동심원 확장 및 추적 알고리즘을 이용한 손동작 인식)

  • Hwang, Dong-Hyun;Jang, Kyung-Sik
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.636-642
    • /
    • 2017
  • In this paper, We proposed a novel hand-gesture recognition algorithm using concentric-circle expanding and tracing. The proposed algorithm determines region of interest of hand image through preprocessing the original image acquired by web-camera and extracts the feature of hand gesture such as the number of stretched fingers, finger tips and finger bases, angle between the fingers which can be used as intuitive method for of human computer interaction. The proposed algorithm also reduces computational complexity compared with raster scan method through referencing only pixels of concentric-circles. The experimental result shows that the 9 hand gestures can be recognized with an average accuracy of 90.7% and an average algorithm execution time is 78ms. The algorithm is confirmed as a feasible way to a useful input method for virtual reality, augmented reality, mixed reality and perceptual interfaces of human computer interaction.

The Feasibility of Event-Related Functional Magnetic Resonance Imaging of Power Hand Grip Task for Studying the Motor System in Normal Volunteers; Comparison with Finger Tapping Task

  • Song, In-Chan;Chang, Kee-Hyun;Han, Moon-Hee
    • Proceedings of the KSMRM Conference
    • /
    • 2001.11a
    • /
    • pp.111-111
    • /
    • 2001
  • 목적: To evaluate the feasibility of the event-related functional MR study using power grip studying the hand motor system 대상 및 방법: Event-related functional MRI was performed on a 1.5T MR unit in seven norm volunteers (man=7, right-handedness=2, left-handedness=5, mean age: 25 years). A single-shot GRE-EPI sequence (TR/TE/flip angle: 1000ms/40ms/90, FOV = 240 mm matrix= 64$\times$64, slice thickness/gap = 5mm/0mm, 7 true axial slices) was used for functiona MR images. A flow-sensitive conventional gradient echo sequence (TR/TE/flip angl 50ms/4ms/60) was used for high-resolution anatomical images. To minimize the gross hea motion, neck-holders (MJ-200, USA) were used. A series of MR images were obtained in axial planes covering motor areas. To exclude motion-corrupted images, all MR images wer surveyed in a movie procedure and evaluated using the estimation of center of mass of ima signal intensities. Power grip task consisted of the powerful grip of all right fingers and hand movement ta used very fast right finger tapping at a speed of 3 per 1 second. All tasks were visual-guid by LCD projector (SHARP, Japan). Two tasks consisted of 134 phases including 7 activatio and 8 rest periods. Active stimulations were performed during 2 seconds and rest period were 15 seconds and total scan time per one task was 2 min 14 sec. Statistical maps we obtained using cross-correlation method. Reference vector was time-shifted by 4 seconds an Gaussian convolution with a FWHM of 4 seconds was applied to it. The threshold in p val for the activation sites was set to be 0.001. All mapping procedures were peformed usin homemade program an IDL (Research Systems Inc., USA) platform. We evaluated the activation patterns of the motor system of power grip compared to hand movement in t event-related functional MRI.

  • PDF

A Case of Neuroblastoma Presenting with Sudden Blindness (실명을 주소로 한 신경아세포종 1예)

  • Ma, In-Youl;Hah, Jeong-Ok;Kim, Chun-Dong;Lee, Tae-Sook
    • Journal of Yeungnam Medical Science
    • /
    • v.2 no.1
    • /
    • pp.259-264
    • /
    • 1985
  • Neuroblastoma is the most common extracranial solid tumor of childhood which presents various clinical symptoms depending on the primary and metastatic sites. However, it has been rarely reported that sudden onset of blindness was the chief complaint of neuroblastoma. A four years old boy was admitted to the Yeungnam University Hospital with the chief complaint of a sudden onset of blindness due to a distant metastasis of abdominal neuroblastoma to the sphenoid sinus. On admission, both side pupils were dilated without light reflex, fundoscopy showed pale optic disk, electroretinogram was subnormal and visual evoked potential showed no response. The liver was palpable in $3{\frac{1}{2}}$ finger breadth from the right costal margin and adult fist sized mass was palpable in the right flank. Skull X-ray showed destructed sphenoid bone and clinoid process and brain CT scan showed tumor mass in the sphenoid sinus and left orbit. Ultrasonogram and CT scan of the abdomen showed large tumor masses around the right kidney and para-aortic and retropancreatic lymph node. IVP showed displaced right calyceal system with preserved contour. Left supraclavicular lymph node which appeared after admission was biopsied and it showed poorly differentiated neuroblasts. He was treated according to the multiagent chemotherapy schedule for stage IV neuroblastoma patient of children's cancer study group. Abdominal tumor masses and sphenoid sinus mass were markedly reduced after 2 courses of the combination chemotherapy of cyclophosphamide, vincristine, DTIC, adriamycin and VM-26. Eventhough the blindness was not improved, the patient has been in good clinical condition.

  • PDF

A Large Ruptured Anterior Communicating Artery Aneurysm Presenting with Bitemporal Hemianopsia

  • Seung, Won-Bae;Kim, Dae-Yong;Park, Yong-Seok
    • Journal of Korean Neurosurgical Society
    • /
    • v.58 no.3
    • /
    • pp.291-293
    • /
    • 2015
  • Anterior communicating artery (ACoA) aneurysms sometimes present with visual symptoms when they rupture or directly compress the optic nerve. Giant or large ACoA aneurysms producing bitemporal hemianopsia are extremely rare. Here we present an unusual case of bitemporal hemianopsia caused by a large intracranial aneurysm of the ACoA. A 41-year-old woman was admitted to our neurosurgical department with a sudden-onset bursting headache and visual impairment. On admission, her vision was decreased to finger counting at 30 cm in the left eye and 50 cm in the right eye, and a severe bitemporal hemianopsia was demonstrated on visual field testing. A brain computed tomography scan revealed a subarachnoid hemorrhage at the basal cistern, and conventional cerebral catheter angiography of the left internal carotid artery demonstrated an $18{\times}8mm$ dumbbell-shaped aneurysm at the ACoA. Microscopic aneurysmal clipping was performed. An ACoA aneurysm can produce visual field defects by compressing the optic chiasm or nerves. We emphasize that it is important to diagnose an aneurysm through cerebrovascular study to prevent confusing it with pituitary apoplexy.

Design of ECG/PPG Gating System in MRI Environment (MRI용 심전도/혈류 게이팅 시스템 설계)

  • Jang, Bong-Ryeol;Park, Ho-Dong;Lee, Kyoung-Joung
    • Journal of Biomedical Engineering Research
    • /
    • v.28 no.1
    • /
    • pp.132-138
    • /
    • 2007
  • MR(magnetic resonance) image of moving organ such as heart shows serious distortion of MR image due to motion itself. To eliminate motion artifacts, MRI(magnetic resonance imaging) scan sequences requires a trigger pulse like ECG(electro-cardiography) R-wave. ECG-gating using cardiac cycle synchronizes the MRI sequence acquisition to the R-wave in order to eliminate image motion artifacts. In this paper, we designed ECG/PPG(photo-plethysmography) gating system which is for eliminating motion artifacts due to moving organ. This system uses nonmagnetic carbon electrodes, lead wire and shield case for minimizing RF(radio-frequency) pulse and gradient effect. Also, we developed a ECG circuit for preventing saturation by magnetic field and a finger plethysmography sensor using optic fiber. And then, gating pulse is generated by adaptive filtering based on NLMS(normalized least mean square) algorithm. To evaluate the developed system, we measured and compared MR imaging of heart and neck with and without ECG/PPG gating system. As a result, we could get a clean image to be used in clinically. In conclusion, the designed ECG/PPG gating system could be useful method when we get MR imaging of moving organ like a heart.

Temple and Maternity Ward Security using FPRS

  • Ambeth Kumar, V.D.;Ramakrishnan, M.;Jagadeesh Kannan, R.
    • Journal of Electrical Engineering and Technology
    • /
    • v.8 no.3
    • /
    • pp.633-637
    • /
    • 2013
  • A wide range of applications for Foot Print Recognition System is discussed in this paper. The whole concept works under the principle that foot print is a parameter associated with biometrics that is very common as well as distinct. Its foremost application is at the government hospitals in the under developed and third world nations where there aren't the best of facilities. This system can be applied in the maternity ward of the hospitals for the identification or differentiation of the infants. Till date there has been no specialized system adopted for this purpose. The Foot Print Recognition System will overcome all the defects of any biometrics when applied here. Since the child will be very delicate for an iris scan and it will not be able to open its eyes wide or to correctly place its finger print on the sensor since the hands of a new born infant will be closed for a while. The Foot Print Recognition system can also be implemented in temples where there are cases of theft often reported. This can be used to grant access to the karpagraham of the deity by authorized users alone. These 2 applications of FPRS are discussed in this paper.

Clinical animal test for development of osseointegration implant;application for beagle tibia (골융합 임플란트 개발을 위한 동물임상실험;비글견 경골 적용)

  • Choi, Kyong-Joo;Kim, Shin-Ki;Mun, Mu-Seong;An, Jae-Yong
    • Proceedings of the KSME Conference
    • /
    • 2003.11a
    • /
    • pp.1373-1377
    • /
    • 2003
  • Current prostheses for amputees are generally extrinsic wearing socket type that the coupling between body stump and appliance wraps the soft tissue and this structure causes several problems :applying direct weight to soft tissue such as skin and muscle, skin trouble of contacting area and pain. In this study, osseointegration implant is a method to directly connect prosthesis to the residual stump skeletal tissue of arm, finger and leg through surgical operation. Technology presented in this paper essentially solves the problems of pain and abnormal weight transfer system indicated above and recovers the functions of the amputated arm and leg. In this paper, implant shape was designed for the first step for the development of osseointegration implant and then we studied the possibility to apply this osseointegration implant to human body by performing implant insertion operation to beagle tibia for the clinical animal test and normal beagle's gait analysis was executed in order to quantitatively verify the beagle's skeletal functions after the implant insertion.

  • PDF

Compression of the Ulnar Nerve in the Ulnar Tunnel Caused by an Anomalous Pulsatile S-shaped Ulnar Artery (척골관에서 척골동맥의 주행 이상에 의한 척골신경의 압박)

  • Cheon, Nam Ju;Kim, Cheol Hann;Kang, Sang Gue;Tark, Min Seong
    • Archives of Plastic Surgery
    • /
    • v.36 no.1
    • /
    • pp.84-88
    • /
    • 2009
  • Purpose: Compression of the ulnar nerve in the ulnar tunnel is a relatively uncommon condition. Many authors have described several etiologies of ulnar nerve compression. We experienced two cases of ulnar nerve compression in the ulnar tunnel due to an anomalous pulsatile S - shaped ulnar artery. Methods: Case 1: A 51 - year - old man was referred with numbness and paroxysmal tingling sensation along the volar side of the ring and little fingers of his right hand for 6 months. When exploration, the ulnar artery was pulsatile S - shaped and was impinging on the ulnar nerve. To decompress the ulnar nerve, the tortuous ulnar artery was mobilized and translocated radially onto the adjacent fibrous tissue. Case 2: A 41 - year - old man was referred with tingling sensation on the 4 th, 5 th finger of the right hand for 4 months. Sensory nerve conduction velocities of the ulnar nerve was delayed. Preoperative 3D angio CT scan showed an anomalous S - shaped ulnar artery. Same operation was done. Results: The postoperative course was uneventful. After decompression, paroxysmal tingling sensation decreased to less than 1 minute per episode, occurring 1 - 2 times a day. After 4 months, they had no more episodes of numbness and tingling sensation. Examination demonstrated good sensation to pinprick and touch on the ulnar aspect of the hand. Conclusion: We report two cases of ulnar nerve compressive neuropathy that was caused by an anomalous pulsatile S - shaped ulnar artery in the ulnar tunnel. Although this is an unusual cause of ulnar nerve compression, the symptoms will not spontaneously resolve. The prompt relief of compressive neuropathic symptoms following the translocation of the impinging ulnar artery from the affected ulnar nerve onto adjacent tissue proved that the ulnar nerve compression is due to the anomalous vessel.