• Title/Summary/Keyword: Fine particulate

Search Result 442, Processing Time 0.03 seconds

Source Identification and Quantification of Coarse and Fine Particles by TTFA and PMF

  • Hwang, In-Jo;Bong, Choon-Keun;Lee, Tae-Jung;Kim, Dong-Sool
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.18 no.E4
    • /
    • pp.203-213
    • /
    • 2002
  • Receptor modeling is one of statistical methods to achieve reasonable air pollution strategies. In order to maintain and manage ambient air quality, it is necessary to identify sources and to apportion its sources for ambient particulate matters. The main purpose of the study was to survey seasonal trends of inorganic elements in the coarse and fine particles. Second, this study has attempted emission sources qualitatively by a receptor method, the PMF mo-del. After that. both PMF (positive matrix factorization) model and TTFA (target transformation factor analysis) model were applied to compare and to estimate mass contribution of coarse and fine particle sources at the receptor. A total of 138 sets of samples was collected from 1989 to 1996 by a low volume cascade impactor with 9 size fraction stages at Kyung Hee University in Korea. Sixteen chemical species (Si, Ca, Fe, K, Pb, Na, Zn, Mg, Ba, Ni, V, Mn, Cr, Br, Cu. Co) were characterized by XRF. The study result showed that the weighted arithmetic mean of coarse and fine particles were 51.3 and 54.4 $\mu\textrm{g}$/㎥, respectively. Contribution of both particle fractions were esti-mated using TTFA and PMF models. The number of estimated sources was seven according to TTFA model and 8 according to PMF model. Comparison of TTFA and PMF revealed that both methodologies exhibited similar trends in their contribution pattern. However, large differences between contributions were observed in some sour-ces. The results of this study may help to suggest control strategies in local countries where known source profiles do not exist.

Effect of Brake Timing on Joint Interface Efficiency of Aluminum Composites During Friction Welding (알루미늄 복합재료의 마찰용접시 브레이크 타이밍이 접합계면 효율에 미치는 영향)

  • Kim Hyun-Soo;Park In-Duck;Shinoda Takeshi;Kim Tae-Gyu
    • Journal of Powder Materials
    • /
    • v.13 no.1 s.54
    • /
    • pp.62-67
    • /
    • 2006
  • Friction welding of $Al_2O_3$ particulate reinforced aluminum composites was performed and the following conclusions were drawn from the study of interfacial bonding characteristics and the relationship between experimental parameters of friction welding and interfacial bond strength. Highest bonded joint efficiency (HBJE) approaching $100\%$ was obtained from the post-brake timing, indicating that the bonding strength of the joint is close to that of the base material. For the pre-brake timing, HBJE was $65\%$. Most region of the bonded interface obtained from post-brake timing exhibited similar microstructure with the matrix or with very thin, fine-grained $Al_2O_3$ layer. This was attributed to the fact that the fine-grained $Al_2O_3$ layer forming at the bonding interface was drawn out circumferentially in this process. Joint efficiency of post-brake timing was always higher than that of pre-brake timing regardless of rotation speed employed. In order to guarantee the performance of friction welded joint similar to the efficiency of matrix, it is necessary to push out the fine-grained $Al_2O_3$ layer forming at the bonding interface circumferentially. As a result, microstructure of the bonded joint similar to that of the matrix with very thin, fine-grained $Al_2O_3$ layer can be obtained.

Particle Analysis of Uranium Bearing Materials Using Ultra High-resolution Isotope Microscope System (초고분해능 동위원소현미경 시스템을 활용한 우라늄 핵종 입자 분석 기술)

  • Jeongmin Kim;Yuyoung Lee;Jung Youn Choi;Haneol Lee;Hyunju Kim
    • Economic and Environmental Geology
    • /
    • v.56 no.5
    • /
    • pp.557-564
    • /
    • 2023
  • Nuclear materials such as uranium are used as fuel for nuclear power generation, but there is a high possibility that they will be used for non-peaceful purposes, so international inspections and regulations are being conducted. Isotope analysis data of fine particulate obtained from nuclear facilities can provide important information on the origin and concentration method of nuclear material, so it is widely used in the field of nuclear safety and nuclear forensics. In this study we describe the analytical method that can directly identify nuclear particles and measure their isotopic ratios for fine samples using a large-geometry secondary ion mass spectrometer and introduce its preliminary results. Using the U-200 standard material, the location of fine particles was identified and the results consistent with the standard value were obtained through microbeam analysis.

Seasonal Changes in the Absorption of Particulate Matter and the Fine Structure of Street Trees in the Southern Areas, Korea: With a Reference to Quercus myrsinifolia, Quercus glauca, Quercus salicina, Camellia japonica, and Prunus × yedoensis (한국 남부지역 가로수종 잎 미세구조와 미세먼지 흡착량의 계절 변화: 가시나무, 종가시나무, 참가시나무, 동백나무, 왕벚나무 중심으로)

  • Jin, Eon-Ju;Yoon, Jun-Hyuck;Choi, Myung Suk;Sung, Chang-Hyun
    • Journal of Korean Society of Forest Science
    • /
    • v.110 no.2
    • /
    • pp.129-140
    • /
    • 2021
  • The study investigates the correlation between the seasonal changes in the absorption of fine dusts and the fine structure of surface on each type of street tree, such as Quercus myrsinifolia, Quercus glauca, Quercus salicina, Camellia japonica, and Prunus × yedoensis in the southernareas of Korea. The absorption ranges of fine dust were 31.51~110.44 ㎍/cm2 in January, 23.20~79.30 ㎍/cm2 in November, 22.68~76.90 ㎍/cm2 in May, and 9.88~49.91 ㎍/cm2 in August. The absorption value was about 54.4% higher in January than in May. With the grooves and hairs on the leaf surface and lots of wax, Q. salicina seems related to the high absorption rate of fine dust for each fine dust particle size. The one with gloss and smooth leaf surface has a low amount of wax. C. japonica Prunus × yedoensisshowed a low absorption rate of fine dust in each season. Whereas the increase in porosity density, length, and leaf area size can be related to the reduced PM and increasedabsorption rate, the leaf surface roughness, total wax amount, and porosity width can be related to the increase in the PM absorption rate. There was also a high correlation between the total wax amount and absorption rate of the leaf surface at the size of PM0.2 than PM10 and PM2.5. These results imply that the quantitative and qualitative trais of leaf, such as wax amounts and leaf surface,can increase the absorption of fine dusts, and the small-sized particles seem to be highly adsorbed with the high wax amounts.

Monitoring of Particulate Matter and Analysis of Black Carbon and Some Particle Containing Toxic Trace in the City of Yaoundé, Cameroon

  • Tchuente, Siaka Y.F.;Saidou, Saidou;Yakum, N.Y.;Kenmoe, N.X.;Abdourahimi, Abdourahimi
    • Asian Journal of Atmospheric Environment
    • /
    • v.7 no.2
    • /
    • pp.120-128
    • /
    • 2013
  • The concentration and composition of particulate matter (PM) in the atmosphere can directly reflect the environmental pollution. The atmospheric pollution in some Cameroonian cities is increasing with the industrial development and urbanization. Air pollution is inherently complex, containing PM of varied size and composition. This PM exists as a dynamic cloud interacting with sunlight and is modified by the meteorology. The reflectometer and the EDXRF spectrometry are applied to determine the concentration of some specific elements at four sites in the city of Yaound$\acute{e}$. The particular aim of the present work is to put in place data base on air pollution in urban area and elaborate regulations on the emissions issued to industrial and vehicle activities. This study provides an overview of the concentration of black carbon and some specific elements in the air, which have impacts on human health. The measurement was done by distinguishing the size of particle. So that, the particle with aerodynamic diameter between $2.5-10{\mu}m$ (so-called coarse particle) and aerodynamic diameter < $2.5{\mu}m$ (so-called fine particle) were considered to obtain more information about levels of the inhalable fraction of the location. The results obtained in four locations of the city of Yaound$\acute{e}$ show that the black carbon concentration is very considerable, the element sulfur is a major pollutant and the concentration of fine particle is very greater. The results obtained of fine and coarse filters range from $5-17{\mu}g/m^3$ and $10-18{\mu}g/m^3$ for the black carbon. S, Cu, Zn, Pb, Cd, As, Se and Hg are the specific findings of this work. The pollutants with a greater concentration are S, Pb, and Zn. These later seem to be non-uniformly, non-regular in some location and high compared to other countries. This work allows us to make a potential relation between pollutants and emission sources. In this framework, some suggestions have been proposed to reduce emissions for an improvement of the air quality in the environment and thus, the one of the city of Yaound$\acute{e}$.

Filtration Characteristics of Paticulate Matter at Bag Filters Coated with PTFE Membrane During Off-Line Pulsing (PTFE membrane이 코팅된 여과백의 off-line 탈진시 미세먼지 집진 특성)

  • Kim, Joung-Hun;Moon, Il-Shik;Hwang, Min-Young;Kim, Ryang-Gyoon;Ko, Daekwun
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.7
    • /
    • pp.391-402
    • /
    • 2017
  • Particulate matter becomes an important issue in the environmental society recently so that it is necessary to evaluate that the commercial application of baghouse systems for effective control of fine particulates is viable. A laboratory-scale baghouse experimental apparatus with filter bags made of PTFE felt or PTFE felt coated with PTFE membrane is used to investigate the filtration performances of fine particulates. Experiments by changing filtration velocity, inlet dust concentration, and average dust particle size show that the dust collection efficiency becomes higher at lower filtration velocity, higher inlet dust concentration and larger average dust particle size. The total pressure drop through the filter media and dust layer becomes higher at higher filtration velocity and higher inlet dust concentration. The dust collection efficiency is higher and the pressure drop is lower at a baghouse with filter bags coated with PTFE membrane than that without membrane coating. From the result that the dust collection efficiency of $PM_{2.5}$ in a reasonable filtration velocity range during off-line pulsing at a baghouse with PTFE felt bag filters coated with PTFE membrane is as high as 99.99%, it is confirmed that the use of baghouse is an effective measure to control the fine particulates.

Removal Efficiency of PM10 & $CO_2$ in Subway Mock-up Cabin (지하철 목업차량내 객실 공기정화장치의 미세먼지(PM10) 및 $CO_2$ 저감성능평가)

  • Kwon, Soon-Bark;Park, Duck-Shin;Cho, Young-Min;Kim, Jong-Bum;Cho, Goan-Hyun;Nam, Goong-Seok;Lee, Joo-Yeol;Kim, Tae-Sung
    • Proceedings of the KSR Conference
    • /
    • 2011.05a
    • /
    • pp.613-618
    • /
    • 2011
  • More than 7 million persons use Seoul Metropolitan Subways (SMS) everyday and the number has been in increasing trend. With the increasing trend of concerns on indoor air quality(IAQ), the management of IAQ has become an important issue, especially in case of subway operators, because most of subway lines are placed underground with poor ventilation condition. The ultimate object of study develop independent cleaning device that reduce efficient fine particle and $CO_2$. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. Two layered electrically pre-charged filters were used for removing particulate matters and gas absorbers are packed between two layer filters for removing gases pollutants such $CO_2$, VOCs and HCHO. Urban subway has characteristics about proper clean air flow, must be installed in narrow space and maintenance cycle has enough time. SCAP prototype is producted as all in one method which decrease fine dust, $CO_2$ and noxious gas. and basic test carry out with quantity of wind, a gap of pressure, sampling efficiency.

  • PDF

Field Application of a Double Filtration Process to Control Fine Dust in a Metro Subway Station (도시 지하역사 미세먼지제어를 위한 이중여과장치의 현장적용 연구)

  • Park, Haewoo;Kim, Wooram;Jo, Youngmin
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.29 no.5
    • /
    • pp.625-633
    • /
    • 2013
  • This study attempted to find an alternative method for fine dust control in the pre-exiting facilities of metro-subway stations. A new double-layer design was proposed for the MVAC (mechanical ventilation and air control) system. Several filter lay-outs were combined a pre-filter with electret filter (EF), electret bundle filter (EBF), or electret pleated filter (EPF), and were then examined focusing on the collection efficiency of particulate matters and pressure drop across the filter layers. The experimental results from the lab and field tests showed the best collection efficiency with EPF, which achieved 85% for $PM_{10}$ and 55% for $PM_{2.5}$. It was also found from the long term field test that the new filter lay-out could provide quite consistent dust level particularly in underground platform regardless of external condition.

A Study on the Coarse Particles Burden to Aerosol in Seoul Area (粗大粒子가 大氣淨遊粉塵에 주는 負荷)

  • 이윤재;김희강
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.1 no.1
    • /
    • pp.71-82
    • /
    • 1985
  • The effect on the particulate matters in the atmosphere was investigated in Seoul area from March, 1984 to Aprill, 1985. Aerosols were collected by filters on nine stages Andrsen Air Sampler, and size distribution and total concentration of the aerosols, Fe and Pb were measured. In spring with Yellow Sand the concentration of particles in aerosols was 185.55$\mug/m^3$ and CP/TA was 65.9%. But in spring without Yellow Sand those of particles was 135.45$\mug/m^3$ and CP/TA was 58.6%. Accordingly the concentration of coarse particles with Yellow Sand was higher than without them in Spring. Above results indicate that in Seoul Area the main source of air pollution originated from natural burdens, especially from soil. The concentration of Pb was similarly valued through both seasons in Seoul area but fine particles valued above coarse particles. On the other hand, in urban area, the natural and anthropogenic sources have influenced on the concentration of Pb. With referred to particle size distribution for Fe, the concentration of coarse particles was 0.168$\etag/m^3$ (CP/TA: 74.3%) in Spring with Yellow Sand, 0.096$\mug/m^3$ (CP/TA: 71.6%) without Yellow Sand and 0.083$\mug/m^3$ (CP/TA: 67.4%) in winter, respectively. Compared with fine particles, all of them were higher. It indicated that the origin of coarse particles in urban air was not related to anthropogenic source. The concentration of Fe was influenced by Yellow Sand and contributed to air pollution.

  • PDF

Concentration Variations of Persistent Organic Pollutants in Gosan, Jeju during the Polluted Period in November 2001 and the Yellow Sand Period in Spring 2002 (2001년 11월 오염시기와 2002년 봄 황사시기 제주도 고산에서의 잔류성 유기오염물질 농도 변화)

  • 김영성;김진영;김연제;문길주;문광주;한진석;김상우;윤순창;권성안
    • Journal of Korean Society for Atmospheric Environment
    • /
    • v.19 no.5
    • /
    • pp.469-490
    • /
    • 2003
  • Atmospheric concentrations of persistent organic pollutants (POPs) were measured at Gosan, Jeju in November 2001 and spring 2002, each time for two weeks. Primary target pollutants were organochlorine pesticides, coplanar polychlorinated biphenyls (co- PCBs), and dioxin/furans listed in the Stockholm Convention adopted in May 2001. Polycyclic aromatic hydrocarbons (PAHs) were also measured in order to understand the overall characteristics of the POPs distribution as well as PM$_{2.5}$, a potent carrier of POPs. In the latter part of the measurement period of November 2001, almost every pollutant of combustion origin including dioxin/furans went high probably due to influence of emissions in the nearby area. The characteristics of atmospheric environment at Gosan in this period were rather close to urban areas far from those of a background area. A severe dust storm swept for three days at the end of the measurement period of spring 2002. However, changes in pollutant concentrations were relatively small except PM$_{10}$. Nevertheless, increases in particulate PAHs and OCDD (octachlorinated dibenzo-p-dioxins), mostly present in fine particles, were observed. Trends in organochlorine pesticide variations were mixed although possible volatilization of DDT residues from soil was inferred from the measurements of spring 2002.2.2.