• 제목/요약/키워드: Fine bubbles

검색결과 48건 처리시간 0.022초

미세기포를 이용한 오염 호소수의 정화에 관한 연구 (Study on the Treatment of Contaminated Lake Water Using Micro Air Bubbles)

  • 김준영;박창원;이종경;장인성
    • 한국환경과학회지
    • /
    • 제16권6호
    • /
    • pp.699-706
    • /
    • 2007
  • Many lakes or irrigative reservoirs in Korea are rapidly contaminated due to the ever increasing pollutants. Although lots of treatment processes have been recommended and practiced, economical and technical improvement is currently needed. In this study, contaminated irrigation reservoir was treated using the proposed process which is consisted of fine air bubbles, coagulation and flotation. Fine bubbles, approximate diameter of 3 to $10{\mu}m$, were generated using cavitation in the pressurized tank and polyaluminum chloride was used as coagulants. This fine bubbles, coagulation and flotation effectively controlled the low density algae, for example, Chlorophyll-a was removed more than 97 %. Removal efficiency of COD, SS, T-N and T-P were 80.7%, 94.3%, 64.1 % and 92.4%, respectively. Pollutants released from the sediments was removed more than 80% of organics and 60-70 % of nutrients. Consequently, fine bubbles coagulation and flotation process could be effectively used as an alternative treatment method for the purpose of control of lake water quality.

미세수소기포를 이용한 환기 터널내의 연기거동 모사 (Simulation of smoke movement in a ventilated tunnel by using fine hydrogen bubbles)

  • 박원희;이한수;장용준;정우성
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 춘계학술대회 논문집
    • /
    • pp.1768-1772
    • /
    • 2008
  • The authors previously presented that the experimental technique using fine bubbles generated by electrolysis simulated fire behavior in a tunnel. We improve this experimental setup to enable this to be considered tunnel-ventilation by circulation of salt water. In this paper we introduce the new experimental setup and the visualization of fine hydrogen bubbles simulated smoke in a ventilated tunnel by using a laser sheet are presented.

  • PDF

미세수소기포를 이용한 터널내의 연기거동 모사 (Experimental modelling of tunnel smoke flow using a fine-bubble technique)

  • 박원희;장용준;김동현;박승일
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2007년도 춘계학술대회 논문집
    • /
    • pp.444-447
    • /
    • 2007
  • The free flow of fine bubbles generated by electrolysis and smoke flow in a space enclosed by fire were recently found to show the same tendency thus leading to the introduction of a research technique. The research experimentally models smoke diffusion and flow in parallel and slanted tunnels using the fine hydrogen bubbles generated by electrolysis in a water tank. Visualization laser with wavelength of 532nm and output power of 1000mW is used to visualize effectively the cross section of fine hydrogen bubble flows generated in a model tunnel.

  • PDF

균일형 유로에서 기포의 거동에 관한 연구 (Study on the Behaivor of Bubbles in Array Type Flow Channels)

  • 정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제24권1호
    • /
    • pp.84-90
    • /
    • 2013
  • The hydrogen or oxygen gas producted by electrolysis become many bubbles in the electrolyte, but exact data on the behavior of these bubbles in the separator of an electrolysis stack didn't become known. In this study, the flow visualization experiment on the behavior of bubbles in the flow pattern of the array type separator is performed by using of a visible alkaline electrolysis stack and a stereoscopic microscope. As the results, a fine size bubbles adhered to the surface of the flow pattern grow to large sized bubbles until each bubble's buoyance is lager than the sum of external force and weight. And then the large bubbles flow into the upper area of the separator. Bubbles adhered to the surface of the vertical flow pattern grow quickly than them adhered to the surface of the horizontal flow pattern. Also, he electrolysis efficiency is declined because many multi-size bubbles occupied the wide volume in the flow pattern.

분리판에서 기포의 거동에 관한 연구 (Study on the Behaivor of Bubbles in the Separators)

  • 유철휘;김종수;박대흠;정영관
    • 한국수소및신에너지학회논문집
    • /
    • 제23권5호
    • /
    • pp.538-544
    • /
    • 2012
  • The bubbles made of hydrogen and oxygen gases producted by electrolysis disturb the electrolysis, but the behavior of these bubbles in the electrolysis stack isn't clearly defined. In order to study on the behavior of bubbles in the flow pattern of the meshes type separator, the flow visualization experiment was performed by using of a visible alkaline electrolysis stack and a stereoscopic microscope. As the results, a fine size bubbles adhered to the separator's surface in the electrolyte solution have grown large sized bubbles until each bubble's buoyance is lager than the sum of surface adhesion force and weight. And then the large bubbles flow into the upper area of the separator. Also, as wide area of the separator have been occupied by various sized bubbles, the electrolysis efficiency is declined.

탈기에 의한 심층포기 호기조 MLSS (Mixed Liquor Suspended Solid) 침전성 향상 방안 연구 (Study to enhance the settleability of deep aeration tank MLSS (Mixed Liquor Suspended Solid) by air sparging)

  • 한지수;이제승;이병희
    • 상하수도학회지
    • /
    • 제38권3호
    • /
    • pp.165-175
    • /
    • 2024
  • The dissolved air at the bottom layer of the deep aeration tank transforms into fine gas bubbles within the MLSS (Mixed Liquor Suspended Solid) floc when exposed to the atmosphere. MLSS floc flotation occurs when MLSS from the deep aeration tank enters the secondary clarifier for solid-liquid separation, as dissolved air becomes fine air within the MLSS floc. The floated MLSS floc causes a high SS (Suspended Solid) concentration in the secondary effluent. The fine air bubbles within the MLSS floc must be removed to achieve stable sedimentation in the secondary clarifier. Fine bubbles within the MLSS floc can be removed by air sparging. The settleability of MLSS was measured by sludge volume indexes (SVIs) after air sparging MLSS taken at the end of the deep aeration tank. MLSS settling tests were performed at MLSS heights of 200, 300, 400, and 500 mm, and compressed air was fed at the bottom of the settling column with air flow rates of 100, 300, and 500 ml/min at each MLSS height, respectively. Also, at each height and air flow rate, air was sparged for 3, 5, and 7 minutes, respectively. SVI was determined for each height, air flow rate, and sparging time, respectively. Experimental results showed that a 300 mm MLSS height, 300 ml/min air flow rate, and 3 minutes of sparging time were the least conditions to achieve less than 120 ml/g of SVI, which was the criterion for good MLSS settling in the secondary clarifier.

원심유동층에서 Al2O3의 기포 거동에 관한 연구 (Bubble Behavior in Centrifugal Fluidized Bed of Fine Particles)

  • 이관석;금성민
    • 한국산학기술학회논문지
    • /
    • 제10권7호
    • /
    • pp.1446-1452
    • /
    • 2009
  • 직경 340mm, 높이 195mm의 원심유동층에서 10.5${\mu}m$와 21.5${\mu}m$의 평균직경을 갖는 $Al_2O_3$를 유동물질로 하여 400, 600, 800, 1000rpm으로 기포의 거동을 규명하고자 2중사진 촬영에 의해 유동가시화현상을 실험하였다. 실험결과, 본 실험 범위에서 원심유동층에서 기포의 거동은 회전수에 영향을 받는 것을 알 수 있었으며, 회전수가 증가함에 따라 기포가 발생하기 시작하는 속도는 증가하였으나 기포의 직경은 감소하는 것을 알 수 있었고 기포의 크기는 상대적으로 작게 나타났다.

THE EFFECT OF AIR BUBBLES FROM DISSOLVED GASES ON THE MEMBRANE FOULING IN THE HOLLOW FIBER SUBMERGED MEMBRANE BIO-REACTOR (SMBR)

  • Jang, Nam-Jung;Yeo, Young-Hyun;Hwang, Moon-Hyun;Vigneswaran, Saravanamuthu;Cho, Jae-Weon;Kim, In S.
    • Environmental Engineering Research
    • /
    • 제11권2호
    • /
    • pp.91-98
    • /
    • 2006
  • There is a possibility of the production of the air bubbles in membrane pores due to the reduction in pressure during membrane filtration. The effect of fine air bubbles from dissolved gases on microfiltration was investigated in the submerged membrane bio-reactor (SMBR). The $R_{air}$ (air bubble resistance) was defined as the filtration resistance due to the air bubbles formed from the gasification of dissolved gases. From the results of filtration tests using pure water with changes in the dissolved oxygen concentration, the air bubbles from dissolved gases were confirmed to act as a foulant and; thus, increase the filtration resistance. The standard pore blocking and cake filtration models, SPBM and CFM, respectively, were applied to investigate the mechanism of air bubble fouling on a hollow fiber membrane. However, the application of the SPBM and CFM were limited in explaining the mechanism due to the properties of air bubble. With a simple comparison of the different filtration resistances, the $R_{air}$ portion was below 1% of the total filtration resistance during sludge filtration. Therefore, the air bubbles from dissolved gases would only be a minor foulant in the SMBR. However, under the conditions of a high gasification rate from dissolved gases, the effect of air bubble fouling should be considered in microfiltration.

정수장(淨水場) Scum의 발생(發生) 원인분석(原因分析)과 살수에 의한 물리적(物理的) 제거효과(除去效果) (Analysis on Occurrence of the Scum in Water Treatment Plants and Its Removal by Water Spray Method)

  • 윤재흥;최계운
    • 상하수도학회지
    • /
    • 제8권3호
    • /
    • pp.26-33
    • /
    • 1994
  • To slove the problems by the scum, which causes operational and water quality problems in water treatment plants, several researches were conducted based on the site investigations on twelve large water treatment plants, biological and chemical analysis of scum, analyzing raw water quality data. Two types of scum, which are from scum and floe scum, can be classified based on the analysis and site investigations. The major parameter generating floe scum was indicated as fine bubbles dissolved in the water. The fine bubbles dissolved in the water can be generated by over-saturated air in the water, adding aluminum surface as the coagulant, conducting the break point pre-chlorination and so on. The water spray method, which is one of the physical treatment methods for removing scum, was selected for conducting experiments on the removal efficiency in the flocculation basin of the real water treatment plant. The water spray method was successfully applied for removing scum with the advantages of using spiral nozzles in case of using the raw water rather than the cleaned water.

  • PDF

치과용 아말감 내부의 수은 유출과 기포의 발생에 관한 연구 (A Study on occurrence of porosity and leakage of mercury in dental amalgam's inside)

  • 김주원
    • 한국치위생학회지
    • /
    • 제10권3호
    • /
    • pp.531-540
    • /
    • 2010
  • Objectives : In this study, following the cavity restorations with low copper conventional alloy, high copper admixed one and high copper unicompositional one, which are used the most frequently in a clinical setting at the present, to experiment the time-dependent changes of strength, bubbles were examined. Besides, to examine the detrimental effects of mercury contained in dental amalgam, the amount of mercury release was evaluated. Methods : As dental amalgams which were used herein, [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy] were selected for a low-copper conventional amalgam, a high-copper admixed one and a high-copper unicompositional one in the corresponding order. The formation of bubbles and the weight ratio of mercury release were evaluated using a field emission scanning electron microscope (FE-SEM). Thus, the following results were obtained: Results : 1. The time-dependent amount of mercury release reached a statistical significance in three types of alloys, which was shown in such a descending order as [BESTALOY], [Hi-Aristaloy 21] and [Sybraloy]. 2. A low-copper conventional type, BESTALOY is a cutting type and it was found to have an increased formation of fine bubbles. In the remaining two types, [Hi-Aristaloy 21] (a high-copper admixed alloy) and [Sybraloy] (a high-copper unicompositional alloy), the time-dependent changes in the formation of bubbles was negligible. Conclusions : Accordingly, this type of mercury release from amalgam alloy denotes the difference in the weight ratio of total constituents between after 24 hours and after two weeks. But further studies are warranted to examine the amount of mercury release which is detrimental to human bodies. Besides, a low-copper conventional alloy is a cutting type and it was characterized by the abundant formation of bubbles in a time-dependent manner. This implies that the strength of amalgam is impaired, which should be considered in selecting the appropriate amalgam alloy in a clinical setting.