• 제목/요약/키워드: Fin-and-tube heat exchanger

검색결과 264건 처리시간 0.028초

An Experimental Study on the Defrosting Behavior of a Fin-Tube Heat Exchanger

  • Lee, Kwan-Soo;Jhee, Sung
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제7권
    • /
    • pp.101-111
    • /
    • 1999
  • The effect of various conditions of frosting and defrosting on the defrosting behavior of a fin-tube heat exchanger has been examined experimentally. An electric heater is used for defrosting in a fin-tube heat exchanger. There are several local maxima in the water draining rate. The amount of residual water on the heat exchanger after completion of defrosting is kept constant due to surface tension on the heat exchanger. Without considering degradation of the thermal performance due to the frosting, the defrosting efficiency is improved with increasing amount of frost irrespective of the frosting condition. The defrosting behavior is affected by frosting density as well as frost accumulation, both of which vary with the experimental operating conditions. The heat loss to the surrounding air decreases, and melting and defrosting efficiencies show high values with decreasing heat input.

  • PDF

마이크로채널과 핀 튜브 열교환기를 적용한 가정용 에어컨디셔너의 성능 평가 (Evaluation of Performance of a Residential Air-Conditioning System Using Microchannel and Fin-and-Tube Heat Exchanger)

  • 윤린
    • 설비공학논문집
    • /
    • 제19권1호
    • /
    • pp.28-35
    • /
    • 2007
  • In this study the seasonal performance of a residential air conditioning system having either a fin-and-tube condenser or a microchannel condenser is experimentally investigated. A commercially available 7 kW capacity residential air conditioning system having a fin-and-tube condenser served as the base system. The test results show that the system with a microchannel heat exchanger has a reduced refrigerant charge amount of 10%, the coefficient of performance is increased by 6% to 10%, and the SEER is increased by 7% as compared with those of the base system. Moreover, the condensing pressure of the system is decreased by 100 kPa and the pressure drop across the condenser is decreased by 84%. The microchannel heat exchanger enhances the SEER of the residential air conditioning system by providing better heat transfers at reduced pressure drops.

Heat Transfer Correlation for the Forced Convective Flow on Single Circular Fin-tube Heat Exchanger

  • Kang Hie-Chan
    • International Journal of Air-Conditioning and Refrigeration
    • /
    • 제14권1호
    • /
    • pp.14-18
    • /
    • 2006
  • This study was performed to investigate the heat transfer characteristics of the circular fin-tube heat exchanger. This paper contains the experimental data for the seven kinds of fin geometries. The correlation of Stasiulevicius agreed with the experimental data at high Reynolds number, however not well at low Reynolds number. The Nusselt number was well correlated with Graetz number, and showed a transition near Gz=10. An empirical correlation proposed in the present study agreed well with the experimental data.

밀집형 열교환기에 사용하는 평판핀 성능에 관한 수치적 연구 (Numerical investigation of plate fin performance for a compact heat exchanger)

  • 유재욱;송태호
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.292-300
    • /
    • 1999
  • Fin conduction not only enhances heat transfer to the ambient air but also increases tube-to-tube conduction. The latter is known to deteriorate the heat exchanger performance. Heat conduction between neighboring tubes thorough the fin is numerically investigated for accurate performance analysis of plate finned-tube heat exchangers. Governing equations for arbitrary plate fin are solved and the temperature distribution is obtained using the principle of superposition. Analysis is made using finite element method by changing the shapes of fin, the arrangements of tubes and the fin parameter mD. It is found that tube-to-tube conduction is significant when mD is small or the distance between neighboring tubes is small.

  • PDF

단일 원형휜-원형관에 대한 강제대류열전달 상관식 (Forced Convection Correlation for Single Circular Fin-tube Heat Exchanger)

  • 강희찬;강민철
    • 설비공학논문집
    • /
    • 제16권6호
    • /
    • pp.584-588
    • /
    • 2004
  • This work was performed to investigate the heat transfer characteristics of the circular fin-tube heat exchanger. This paper contains the experimental data for the seven kinds of fin geometries. The correlation of Stasiulevicius agreed with the experimental data at high Reynolds number, however not well at low Reynolds number. The Nusselt number was well correlated with Graetz number, and showed a transition near Gz=10. An empirical correlation proposed in the present work agreed well with the experimental data.

핀 튜브 열교환기와 알루미늄 열교환기의 성능 비교 (Performance Comparison of Fin-Tube Heat Exchanger and Aluminum Heat Exchanger)

  • 장근선;이현수;김재덕;홍석률
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2008년도 하계학술발표대회 논문집
    • /
    • pp.408-413
    • /
    • 2008
  • This study presents comparison of the air side heat transfer and friction characteristics in a heating condition between Louver fin-tube heat exchangers and aluminum heat exchangers. Experiments are performed for the Louver fin-tube heat exchangers and aluminum heat exchangers using a calorimeter, which is designed based on air-enthalpy method described in ASHRAE standards. The air velocities its are varied from 0.7 to 1.6 m/s with 0.3 m/s interval. A study result shows that the heat transfer performances of aluminum heat exchangers are $40{\sim}80%$ higher than those of Louver fin-tube heat exchangers per unit volume, mass and heat transfer area.

  • PDF

에어컨 실외기용 휜-관 직교형 열교환기의 열, 유동 해석 및 휜 성능 개선을 위한 연구 (Flow and heat transfer analysis for the performance improvement of cross-flow fin-tube heat exchangers)

  • 안진수;최도형
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2004년도 춘계 학술대회논문집
    • /
    • pp.183-189
    • /
    • 2004
  • The flow and the heat transfer about the cross-flow fin-tube heat exchanger in an out-door unit of a heat pump system has been numerically Investigated. Using the general purpose analysis code, FLUENT, the Navier-Stokes equations and the energy equation are solved for the three dimensional computation domain that encompasses multiple rows of the fin-tube. The temperature on the fin and tube surface is assumed constant but compensated later through the fin efficiency when predicting the heat-transfer rate. The contact resistance is also taken into consideration. The flow and temperature fields for a wide range of inlet velocity and fin-tube arrangements are examined and the results are presented in the paper. The details of the flow are very well captured and the heat transfer rate for a range of inlet velocity is in excellent agreement with the measured data. The flow solution provides the effective permeability and the inertial resistance factor of the heat exchanger if the exchanger were to be approximated by the porous medium. This information is essential in carrying out the global flow field calculation which, in turn, provides the inlet velocity lot the microscopic temperature-field calculation of the heat exchanger unit.

  • PDF

열전달 촉진 핀-관 열교환기의 공기측 압력강화 및 열전달 특성에 관한 실험 (Experimental Study of Air Side Pressure Drop and Heat Transfer Characteristics of Enhanced Fin-Tube Heat Exchangers)

  • 윤백;길용현;박현연;김영생
    • 대한기계학회논문집B
    • /
    • 제22권11호
    • /
    • pp.1555-1563
    • /
    • 1998
  • Heat transfer and pressure drop for ${\phi}10.07$ dry surface fin-tube heat exchanger with wave and wave-slit fins were measured for different fin spacings and number of tube rows. Longitudinal and transverse tube spacings of the heat exchangers are 21.65mm and 25mm respectively, and wave depth of wave fin is 1.5mm. The experiments were performed for 4 different fin spacings, 1.3, 1.5, 1.7 and 2.0mm, and the number of tube rows were 1,2 and 3 rows. The present results were compared with the previous results for the wave depth of 2mm. Also hydrophilic coated and bare fins were tested. Correlations for Colburn j-factor and friction factor were developed.

미소열교환기법에 의한 밀집형 열교환기의 성능 계산 : 핀을 통한 튜브간 전도의 영향 (Computation of Compact Heat Exchanger Performance by the Heat Exchangelet Method : Effect of Tube-to-tube Conduction along the Fin)

  • 성시경;송태호;최영철
    • 설비공학논문집
    • /
    • 제12권5호
    • /
    • pp.494-501
    • /
    • 2000
  • Effectiveness of a 3-pass plate finned-tube heat exchanger is calculated using heat exchangelet method by changing the shape of fin and the arrangement of tubes. The alternative refrigerant R134a is taken in this study. Conduction between neighboring tubes along the fin is taken into account in addition to convection between the fin and the surrounding air. Governing equations are obtained by using energy balance in a small control volume containing a tube and fins. They are numerically solved following the tube. Effect of tube-to-tube conduction is investigated in single-phase and two-phase flows with various fin shapes and arrangements of tubes. Improvement of effectiveness by fin perforation is studied too. The results shows that perforating fins, increasing the number of tubes, and increasing the distance between neighboring tubes at the same fin area enhance the effectiveness.

  • PDF

휜-관 열교환기의 착상 성능 해석 (Analysis of Frosting Performance of a Fin-Tube Heat Exchanger)

  • 양동근;이관수
    • 설비공학논문집
    • /
    • 제17권11호
    • /
    • pp.965-973
    • /
    • 2005
  • This paper proposes a mathematical model for predicting the frosting performance on a fin-tube heat exchanger. The model consists of empirical correlations of average heat transfer coefficients for the plate and tube surfaces and a diffusion equation inside the frost layer. The numerical results are compared with experimental data for the frost thickness, the frosting rate and the heat transfer rate to validate the proposed model. The results are in good agreement with the experimental data, and show that this model can be applied to predict frosting performance of common fin-tube heat exchanger.