• Title/Summary/Keyword: Filtration rate

Search Result 712, Processing Time 0.028 seconds

Assessment of Aging Effects on Computed Tomographic Glomerular Filtration Rate in Dogs (개에서 연령에 따른 동적 컴퓨터단층촬영을 이용한 사구체여과율의 평가)

  • Chang, Jin-Hwa;Kim, Hwan-Cheol;Choi, Ji-Young;Choi, Ho-Jung;Lee, Hee-Chun;Chang, Dong-Woo;Lee, Young-Won
    • Journal of Veterinary Clinics
    • /
    • v.29 no.2
    • /
    • pp.130-133
    • /
    • 2012
  • The purpose of this study is to assess the relationship between glomerular filtration rate (GFR) and age by using dynamic computed tomography (CT) and Patlak plot analysis in dogs. Fifteen dogs were used in this study. CT-GFR study was performed under general anesthesia using propofol and isoflurane. 1 ml/kg dosage of 300 mgI/ml iohexol was administered at a rate of 3 ml/s during GFR measurement. CT-GFR was determined with a single-slice dynamic acquisition and Patlak plot analysis. The individual and global GFR values were calculated to plasma clearance per body weight (ml/min/kg). Bodyweight ($mean{\pm}SD$) ranged from 2.0 to 5.7 kg ($3.31{\pm}1.13$ kg). Age ranged from 3 years to 13 years old ($7.14{\pm}3.30$). $Mean{\pm}SD$ creatinine ($0.53{\pm}0.34 $mg/dl), phosphorus ($4.1{\pm}1.2$ mg/dL), and albumin ($3.3{\pm}0.3$ mg/dL) concentrations and urine protein-to-creatinine ratios (all ratios were < 0.5) were within reference ranges. Abdominal ultrasonography revealed small-sized renal calculi, mineralization, or renal cyst at eight dogs. The global CT-GFR ranges shown in this study was 2.57 to 6.60 ml/min/kg. In this study, there was no trend toward weight-adjusted CT-GFR with increasing age. We found no relationships between age-related kidney dysfunction in fifteen dogs. Small-sized renal calculi or cysts did not affect renal function in this study. However, it is thought that a large sample size may have been required to document an age effect.

Production and Separation of Anti-hypertensive Peptide during Chunggugjang Fermentation with Bacillus subtilis CH-1023 (청국장 발효과정 중 항고혈압성 peptide의 생산 및 분리)

  • Cha, Woen-Suep;Bok, Su-Kyung;Kim, Myoung-Uk;Chun, Sung-Sook;Choi, Ung-Kyu;Cho, Young-Je
    • Applied Biological Chemistry
    • /
    • v.43 no.4
    • /
    • pp.247-252
    • /
    • 2000
  • As functionality investigation of Korean traditional soybean fermentation foods, an antihypertensive peptide was separated during Chunggugjang fermentation by Bacillus subtilis CH-1023 and investigated inhibitory effect against angiotensin converting enzyme. After incubation at $20^{\circ}C,\;30^{\circ}C,\;40^{\circ}C,\;50^{\circ}C,\;60^{\circ}C$ for the $0{\sim}72$ hrs, protein content, protease activity and angiotensin converting enzyme inhibitory rate were determined. The protein content and protease activity were increased and reached maximum at 60 hrs fermentation with $40^{\circ}C$ and decreased after the 60 hrs fermentation. The optimum condition for antihypertensive peptide from Chunggugjang was appeared for 60 hrs at $40^{\circ}C$. Crude extract of Chunggugjang was partially purified by Amicon YM-3 membrane filtration and Sephadex G-10, G-25 gel filtration. The purified peptide showed inhibitory rate of 94.3% with 0.5 mg peptide content. The most prominent amino acid composition of the peptide from Chunggugjang was alanine, followed by phenylalanine, histidine.

  • PDF

Application of Ceramic MF Membrane at the Slow Sand Filtration Process (완속모래여과 공정에서 세라믹 MF 막의 적용)

  • Choi, Kwang-Hun;Park, Jong-Yul;Kim, Su-Han;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.35 no.12
    • /
    • pp.877-882
    • /
    • 2013
  • The application of ultrafiltration (UF) and microfiltration (MF) membranes has been increased for drinking water purification. The advantages of UF/MF membrane process compared to conventional treatment processes are stable operation under varying feed water quality, smaller construction area, and automatic operation. Most membrane treatment plants are designed with polymeric membranes. Recently, some studies suggested that the process of treating surface water with ceramic membranes is competitive to the application of polymeric membranes. Higher water flux, less frequent cleaning, and much longer lifetime are the advantages of ceramic membrane comparing to polymeric membrane. Therefore, this research focused on the application of ceramic MF membrane pilot plant at the slow sand filtration plant. The ceramic membrane pilot plant has three trains that used raw water and sand filtered water as a feed water, respectively. For optimizing the pilot plant process, the coagulation with PACl coagulant was used as a pretreatment of ceramic membrane process. In addition, CEB (Chemical Enhanced Backwash) process using $H_2SO_4$ and NaOCl was used for 1.5 days, respectively. The experimental results showed that applying the optimum coagulant dose before membrane filtration showed enhancing membrane fluxes for both raw water and sand filtered water. Also, when using raw water as a feed of membrane, minimum fouling rate was 2.173 kPa/cycle with 25 mg/L of PACl and when using sand filtered water, the minimum fouling rate was 0.301 kPa/cycle with 5 mg/L of PACl.

Optimization of Ultrafiltration Process using $MIEX^{(R)}$+Coagulation Process ($MIEX^{(R)}$+응집공정을 이용한 한외여과 공정의 최적화 : 다양한 전처리 공정의 적용에 따른 막 오염 현상 규명)

  • Son, Hee-Jong;Hwang, Young-Do;Roh, Jae-Soon;Jung, Chul-Woo;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.27 no.7
    • /
    • pp.753-761
    • /
    • 2005
  • In this study, pretreatment of organic matters with $MIEX^{(R)}$ was evaluated using bench-scale experimental procedures on four organic matters to determine its effect on subsequent UF membrane filtration. For comparison, coagulation process was also used as a pretreatment of UF membrane filtration. Moreover, the membrane fouling potential was identified using different fractions and molecular weights of organic matters. From the removal property of MW organic matters by coagulation process for the sample water NOM and AOM, the removal efficiency of high MW organic matters were much higher than those of low MW organic matters. It was shown that the removal efficiency of high MW organic matter more than 10 kDa was lower than that of low MW organic matter for $MIEX^{(R)}$ process. For the change of permeate flux by the pretreatment process, $MIEX^{(R)}$+UF process showed high removal efficiency of organic matter as compared with coagulation-UF processes, but high reduction rate of permeate flux was presented through the reduction of removal efficiency of high MW organic matter. From sequential filtration test results in order to examine the effect of MW of organic matter on membrane fouling, it was found that the membrane foulant was occurred by high MW organic matter, and the DOC of organic matter less than 0.5 mg/L was working as the membrane foulant. In the case of sample water composed of low MW organic matter less than 10 kDa, since the low MW organic matter less than 10 kDa has high removal efficiency by $MIEX^{(R)}$, low reduction rate of permeate flux is obtained as compared with coagulation-UF processes. In summary, it is required to conduct the research on physical/chemical characteristic of original water before pretreatment process of membrane process is selected, and a pertinent pre-treatment process should be employed based on the physical/chemical characteristic of original water.

A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy (동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰)

  • Ham, Jun-Cheol;Bahn, Young-Kag;Park, Min-Soo;Cho, Seok-Won;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • Purpose: Glomerular filtration rate is an important index for assessment of renal function, early discovery of renal disease, and progress observation of chronic renal disease patients. In the present study, the objective is to conduct a comparative analysis of differences between Gates and Modified Gates method in dynamic renal scintigraphy based on MDRD (Modification of Diet Renal Disease) formula using blood collection. Materials and Methods: Renal scintigraphy was performed for 45 patients who visited our hospital between November 2010 and August 2011. For 20 patients of those tested, glomerular filtration rates from Gates method and MDRD formula using AGUS equipment, were compared. For the other 20 patients, glomerular filtration rates from Modified Gates method and MDRD formula using INFINIA equipment. Finally, Gates and Modified Gates method were compared for 5 patients who indicated no change in glomerular filtration rates from MDRD formula during progress observation. Results: Glomerular filtration rates from both Gates and Modified Gates method showed a high correlation with those from MDRD formula ($p$<0.01, r=0.903, r=0.867), with a paired difference mean for Gates method of $2.05{\pm}2.54mL/min/1.73m$, and that for Modified Gates method of $25.2{\pm}3.71mL/min/1.73m$. Finally, the values for Gates method and those for Modified Gates method showed a high correlation for the five patients ($p$<0.05, r=0.949), with a paired difference mean of $20.4{\pm}8.84mL/min/1.73m$. Conclusion: Glomerular filtration rates from Gates method, Modified Gates method and MDRD formula showed mutually high correlations. If the tests are performed with recognition for the correlations between Gates and Modified Gates method used in a dynamic renal scintigraphy, then an accurate assessment of renal function is considered possible with an improved diagnostic ability.

  • PDF

Rapid Detection Method for Human Rotavirus from Vegetables by a Combination of Filtration and Integrated Cell Culture/Real-Time Reverse Transcription PCR (Filtration과 Integrated Cell Culture/Real-Time Reverse Transcription PCR 기법을 이용한 채소류에서 Human Rotavirus 신속 검출)

  • Hyeon, Ji-Yeon;Chon, Jung-Whan;Song, Kwang-Young;Hwang, In-Gyun;Kwak, Hyo-Sun;Lee, Jung-Soo;Kim, Moo-Sang;Lee, Jung-Bok;Seo, Kun-Ho
    • Korean Journal of Microbiology
    • /
    • v.47 no.2
    • /
    • pp.117-123
    • /
    • 2011
  • The purpose of this study was to evaluate and compare different elution and concentration methods for optimization of human rotavirus (HRV) detection method using real-time RT-PCR and cell culture techniques. The leafy vegetable samples (lettuce, Chinese cabbage) were artificially inoculated with HRV. Viruses were extracted from the vegetables by two different elution buffers, buffer A (100 mM Tris-HCl, 50 mM glycine, 3% beef extract, pH 9.5) and buffer B (250 mM Threonine, 300 mM NaCl, pH 9.5), and the extracted viruses were concentrated by filtration and PEG precipitation sequentially. To determine infectivity of the viruses, the viruses recovered from the samples were infected to the MA-104 cells, and integrated cell culture real-time RT-PCR was performed at 1, 48, 72, 96, 120, 144, 168 h post-infection (p.i.). The elution buffer A was more efficient in extracting the virus from the produce samples tested than the buffer B, 29.54% and 18.32% of recoveries, respectively. The sensitivity of real-time RT-PCR method was markedly improved when the virus was concentrated by the filtration method. When the viruses were eluted and concentrated by buffer A and filtration, respectively, the average recovery rate was approximately 51.89%. When the viruses recovered from samples were infected to MA-104 cell, infectious HRV was detected within 48 h p.i. by ICC/real-time RT-PCR, whereas cytopathic effects were not observed until 72 h p.i. The optimized detection method evaluated in this study could be useful for rapid and reliable detection of HRV in fresh produce products and applied for detection of other food-borne viruses.

A Study of Filtralite Media Applicability for Development F/A Process of Membrane Filtration Pre-treatment Process in the Water Purification Plant (정수장에서 막여과 전처리용 F/A 공정 개발을 위한 Filtralite 여재의 적용성 연구)

  • Kim, JUN-Hyun;Jun, Yong-sung;Kwak, Young-ju;Jang, Jung Woo
    • Membrane Journal
    • /
    • v.25 no.6
    • /
    • pp.503-514
    • /
    • 2015
  • In this study, water purification system without coagulant was consisted of F/A and membrane to produce purified water which only uses physical treatment without coagulant. Because the use of coagulant has a possibility remaining of hazardous aluminum with our health. Especially, the Filtralite was reviewed the possibility to remove turbidity and organic material. It was found that the turbidity removal rate of Filtralite was 83~84%. It show that Filtralite has similar efficiency to sand-filter. But Filtralite has higher 50% removal rate of organic material than sand-filter due to well-developed pore on the surface of it. So, Filtralite could be used to substitute the sand-filter for the F/A process due to higher removal rate. And also coupled with activated carbon in F/A process, TMP was increased by TOC value. To prevent increasing TMP, media that has outstanding organic adsorption ability should be used.

A Study on Operating Condition of Test-Bed Plant using Membrane filtration of D Water Treatment Plant in Gwang-Ju (D정수장 정밀여과막 실증플랜트의 최적 운전조건 연구)

  • Yang, Hyung-Jae;Yi, Seung-Hoon;Moon, Kyung-Ran
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.3
    • /
    • pp.155-163
    • /
    • 2017
  • Membrane filtration has become more popular in drinking water treatment recently, since the filtration can control not only particulate matters but also pathogenic microorganisms such as giardia and cryptosporidium very effectively. Pilot-scale ($120m^3/d$ of treatment capacity) and test-bed ($25,000m^3/d$ of treatment capacity) microfiltration experiments were conducted to find optimum operating mode and the critical flux. Optimum operating mode of pilot-test was assessed as inflow 1.0 min, filtration 36.5 min, air backwash 0.9 min, backwash 1.0 min and outflow 1.0 min with 50 LMH ($L/min{\cdot}m3^$) of critical flux. Critical Flux was calculated to be $50L/m^2-h$ (within TMP 0.5 bar) based on the increase formula of the transmembrane pressure difference according to the change of time at Flux 20, 40, 56 and 62 LMH in pilot operation. Chemical cleaning was first acid washed twice, and alkali washing was performed secondarily, and a recovery rate of 95% was obtained in the test-bed plant. The results of operating under these appropriate conditions are as follows. Turbidity of treated water were 0.028, 0.024, 0.026 and 0.028 NTU in spring, summer, autumn and winter time, respectively. Microfiltration has superior treatment capability and performance characteristics in removing suspended solids and colloidal materials, which are the main cause of turbidity and important carrier of metal elements, and it has shown great potential in being an economically substitute to traditional processes (sand filtration).

Numerical Analysis of Horizontal Collector Well in Riverbank Filtration (수평 방사형 집수정 활용 강변여과 취수 수치 분석)

  • Kim, Hyoung-Soo;Jeong, Jae-Hoon
    • Journal of Soil and Groundwater Environment
    • /
    • v.14 no.1
    • /
    • pp.1-10
    • /
    • 2009
  • Groundwater flow due to intake of horizontal collector well in riverbank filtration site was analyzed by use of numerical groundwater modeling program (FEFLOW 5.1). Drawdowns of groundwater table nearby collector well were evaluated according to variations of several conditions; pumping rate, thickness of aquifer, offset distance from well to shore line of stream, conductance of streambed. It is observed that the drawdowns of groundwater table are clearly changed according to the variations of these conditions. The results of sensitive analysis shows that the thickness of alluvial aquifer and the offset distance are more sensitive than the conductance of streambed in evaluation of drawdown. This result implies that hydrogeological conditions, as like thickness of aquifer and its distribution in the site are important factors in site selection and evaluating the availability of riverbank filtration intake using horizontal collector well system. It is also revealed that numerical modeling using FEFLOW with 1-D discrete element feature can give efficient quantitative evaluation of horizontal collector well and estimation of availability of riverbank filtration site.

Comparisons of Certification Standards for Mask and Review on Filtration Efficiency for Viruses (마스크의 인증기준 비교와 바이러스 여과효율에 대한 고찰)

  • Yoon, Chungsik;Go, Sulbee;Park, Jihoon
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.30 no.2
    • /
    • pp.109-123
    • /
    • 2020
  • Objectives: The aims of this study were to review the standards and key components of the standards for disposable masks in Korea, the US, EU, Japan, and China and to evaluate the appropriateness of disposable masks during a virus pandemic. Methods: We reviewed the standards in the above countries and compared their key elements for each standard. For the second purpose, systemic paper gathering using key words like 'mask', 'respirator' 'virus', and 'coronavirus' in the PubMed search engine was performed. Fifty-three papers were selected and reviewed in regard to the appropriateness of test protocols with sodium chloride(NaCl) particles for virus filtration and the effectiveness against viruses. Results: The standards for masks are largely divided into two categories: US standards and EU standards. In Korea, the Ministry of Employment and Labor adapted the EU standards for workers and the Health Masks adopted the Ministry of Employment and Labor standards by the Ministry of Food and Drug Safety. Regarding airborne viral infections, WHO emphasizes only droplet infection, while many studies have shown that small particles enter the air through coughing or sneezing, which increases the possibility of airborne infection. Compared to other particles, various factors such as airborne viability and the ability to replicate the virus in the body are further involved in the virus's airborne infection rate. Airborne infection is classified into absolute air infection, preferential air infection, and opportunistic air infection. The NaCl-certified N95 mask showed good filtration efficiency against viruses and NaCl particles were proved to be a surrogate material for viruses. From this, KF94 is also expected to be effective in blocking viruses. Conclusion: The N95 test method could be used as a surrogate test method for virus filtration. N95-class masks have been found to effectively block viral infections in the air. However, surgical or medical masks are only partially effective against airborne virus infection though they could effectively block large droplet infection. However, most studies considered in this study targeted N95 in foreign countries and studies on masks actually used in Korea are very limited, so studies on microorganisms and reuse on domestic masks should be conducted in the future.