• Title/Summary/Keyword: Filtration efficiency

Search Result 516, Processing Time 0.028 seconds

Comparison of Efficiency between Pre-storage and Post-storage filtration by Leukoreduction Blood Filter

  • Shin, Geon Sik;Kim, Bohee;Kim, Sung Hoon;Rhee, Ki-Jong;Kim, Yoon Suk
    • Biomedical Science Letters
    • /
    • v.23 no.2
    • /
    • pp.111-117
    • /
    • 2017
  • Leukocytes in blood components are involved in diverse adverse transfusion reactions such as febrile non-hemolytic transfusion reactions. Therefore, leukocyte reduction is required to reduce these adverse reactions. The objective of this study was to compare the efficiency of pre-storage filtration and post-storage filtration. Filtration time, residual leukocyte count, RBC recovery, and hemolysis were assessed after pre-storage or post-storage filtration. Compared to pre-storage filtration, filtration time was prolonged and hemolysis was dramatically increased when post-storage filtration was performed. Residual leukocytes count and RBC recovery after post-storage filtration were similar with those obtained after pre-storage filtration. These results suggest that pre-storage filtration has better efficiency than post-storage filtration. These are thought to contribute to the production of better quality of leukoreduction blood components.

Filtration efficiency and Manikin-based Total Inward Leakage Study of Particle Filtering Mask Challenged with Silver Nanoparticles (은나노입자에 대한 방진마스크 포집효율 및 총누설율)

  • Kim, Jong-Kyu
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.26 no.3
    • /
    • pp.367-376
    • /
    • 2016
  • Objectives: The production and use of nanoparticles have been increased. In 2014 Workplace Survey Results, 335 companies produce and treat nanoparticls. However, lack of data on nano-toxicity and a method for risk management and regulation on nanoparticles and the standard test method are not sufficient. Protective equipment selection guidelines for nanoparticles are not established. It is required to carry out respirator efficiency test against nanoparticles. This study was performed to evaluate filtration efficiency and manikin-based total inward leakage of particle filtering mask using in Korean country challenged with silver nanoparticles. Methods: We investigated filtration efficiency and total inward leakage of 7 respirator with silver nanoparticle. Results: The geometric mean diameters of Silver nanoparticles were 30 nm and number concentration were about $10^6{\sharp}/cm^3$. Filtration efficiency of six of the seven particle filtering masks was more than 98% and one particle filtering masks filtration efficiency was 94.9%. The filtration efficiency of particle filtering masks to 20 nm silver nanoparticels was highest. Artificial breathing machine with manikin based total inward leakage were 7.6% ~ 42.3%. Conclusions: The results of this study nano-silver filter efficiency was high but the total inward leakage was higher than filter penetration. Therefore, education on how to wear a respirator should be demanded. Especially for workers handling nanoparticles and toxic material, user seal checking and fit test must be performed.

Filtration Efficiency of Electrically Charged Air Filters by a Corona Method

  • Murtadlo, Zainul Alim Ali;Joe, Yun-Haeng;Park, Seok-Hoon;Park, Hyun-Seol
    • Particle and aerosol research
    • /
    • v.15 no.1
    • /
    • pp.15-25
    • /
    • 2019
  • The influences of corona charging parameters on collection efficiency and surface potential of air filters were investigated. A polypropylene filter medium was electrically charged using a corona charger, and the resulting surface potential and filtration efficiency against neutralized KCl particles were measured. The filter media was charged under different conditions of applied voltage, voltage polarity, charging time, and distance between electrodes. In addition, we considered charging both sides of the filter as well as charging one side of the filter. As a result, electrical force obtained by charged fiber affected filtration efficiency when the apply voltage strength was higher than 7 kV. Negatively charged filter had higher filtration efficiency than positively charged filter while the surface potential of the negatively charged filter was slightly lower than those of positively charged filter. Moreover, the filtration efficiency increased as the charging time of filter fiber increased and the distance between electrodes decreased. The filtration efficiency was more sensitive to changes of charging time than to those of electrode distance, and the efficiency of both sides charged filter was higher than that of single side charged filter.

Changes of Particle Filtration Efficiency of Cloth Masks by Machine Washing and Cloth Expansion (세탁 및 옷감 신장에 따른 천마스크 제품의 여과효율 변화)

  • Kim, Seung Won
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.27 no.2
    • /
    • pp.115-122
    • /
    • 2017
  • Objectives: This study was designed to evaluate the changes in the particle filtration efficiencies of five cloth masks (4 plate types, 1 cup type) with an increasing number of machine washings and the degree of cloth expansion. Methods: NaCl aerosols were generated using an atomizer and passed through cloth masks in a dynamic aerosol chamber. Particle concentrations were measured both before and after for the cloth masks using an optical particle counter (OPC) in the size range of $0.3{\sim}10{\mu}m$. Results: In the original condition, the filtration efficiencies of the five cloth masks were A: 20.1%, B:30.9%, C: 25.0%, D: 26.5%, and E: 40.9%. As the number of washings increased in the order of one, two, and four times, the filtration efficiencies of cloth mask C increased. The filtration efficiency of A, D, and E increased after the first washing. With the exception of B, the filtration efficiency of cloth masks increased after the second washing and those of all cloth masks increased after the fourth washing. This might be caused by the fibers untangling from the yarn and being freed at one end. In this status, the packing density of the textile will not change, but the distances between fibers will increase, which might bring about an increase in filtration efficiency. When the cloth masks were extended by 10% and 20% in one direction, the filtration efficiencies of cloth masks B, D, and E decreased at 10% extension, and those of all cloth masks decreased at 20% extension. When the cloth masks were expanded by 10% and 20% in two directions, the filtration efficiencies of all cloth masks decreased by at least 34.7% at 10% extension, and by at least 60.9% at 20% extension Conclusions: The filtration efficiency of cloth masks could decrease after one to two machine washings, but will increase after four washings in comparison with their original performances. The filtration efficiency of cloth masks will decrease when they are expanded, such as when stretching over the nose during wearing status.

An Experimental Study on Filtration Efficiency and BPT Characteristics by Soot Loading in Partial-diesel Particulate Filter (포집량에 따른 p-DPF의 정화효율 및 BPT 특성에 관한 실험적 연구)

  • Kim, Tae-Kwon;Kim, Young-Jo;Ha, Ji-Soo;Lee, Chun-Beom;Oh, Kwang-Chul
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.19 no.6
    • /
    • pp.10-16
    • /
    • 2011
  • Diesel particulate filter is being recognized that it is the most effective technologies to reduce particulate matter. In this study, to determine the characteristics of the cell-open-type pDPF, we employed p-DPF to exhaust gas tunnel of diesel engine and surveyed filtration efficiency and BPT on the basis of PM which is exhausted from engine. In this paper the soot loading mass in DPF can be predicted from increase of differential pressure of DPF so that we can measure filtration efficiency and Balance Point Temperature (BPT) by soot loading mass. The result of the research showed that the filtration efficiency is 65% in ESC mode with 0.7mm hole diameter. For the results of the characteristics of filtration efficiency and BPT according to mass_exh, we found that if mass_exh increases, filtration efficiency increases and BPT decreases.

A Study on Filtration Efficiency of Several Dust Masks for Stainless Steel arc Welding fume (방진마스크의 Stainless steel arc 용접흄 여과효율에 관한 연구)

  • Song, Kyung-Seuk;Kwon, Yong-Shick;Han, Kuy-Tae;Chung, Kyu-Hyuck;Lee, Yong-Mook;Yu, Il-Je
    • Journal of Korean Society of Occupational and Environmental Hygiene
    • /
    • v.11 no.1
    • /
    • pp.42-47
    • /
    • 2001
  • The purpose of this study was to investigate for filtration efficiency of several dust masks, comparing with filtration efficiency certified by KOSHA(Korea Occupational Safety & Health Agency), and to require of the right use of protective respirators. Using a welding fume generator and chamber, several dust masks, which were widely used in the workplaces in korea, were tested for their filtering efficiency for stainless steel arc welding fume. The filtration efficiency testing system consisted of a welding fume generator, a chamber and a filtration unit. The filtration unit was made of a mask which was inserted into the sampling cassette and another sampling cassette, which contained mixed cellulose ester filter paper. These two cassettes were connected with tubing. Stainless steel arc welding fume generator was delivered into an chamber. The welding fume in the chamber was passed into the filtration unit with flow rate of 30 liter/min. The welding fume filtration efficiency was evaluated by gravimetric measurement. Metal concentrations in the welding fume before and after filtration were measured with inductive coupling plasma analyzer. Following results were obtained: Filtration efficiency of welding fume for common hygienic mask was 63.82% and the average efficiencies for A, B, C, D, E, F and G masks were 94.62%, 96.58%, 83.20%, 82.76%, 77.25%, 86.55% and 93.22%, respectively. Our results indicate that dust masks used widely in the welding workplaces in korea are not proper for protecting worker's health and then the use of fume mask should be required.

  • PDF

Performance of fiber media filter device for combined sewer overflows treatment (합류식 하수관거 월류수 처리를 위한 섬유사 여과 장치의 처리특성)

  • Son, Sang-Mi;Warangkana, Jutidamrongphan;Park, Ki-Young;Park, Chul-Hwi
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.24 no.2
    • /
    • pp.231-236
    • /
    • 2010
  • A compressible media filtration process with synthetic fiber media was studied for combined sewer overflows (CSOs) treatment. Since the operation performance of fiber media filtration was dependent on the pattern of CSOs, the flow rate of CSOs was investigated and it was characterized by a big fluctuation. Thus, in this study, the fiber media filtration process was tested with wide range of filtration velocity. The removal efficiency was proportion to the increase in compressibility. As the filtration velocity was increased, the treatment efficiency was decreased and consequently leveled off when the velocity exceeded 750 $m^3/m^2$/d. An exponential equation was introduced to express the relationship between the removal efficiency and up-flow velocity. At columm test, six repetition of filtration and backwash cycle did not after the filtering velocity under the constant pressure condition.

An Experimental Study on Filtration Efficiency and BPT Characteristics by PM Loading in Partial-diesel Particulate Filter (포집량에 따른 p-DPF의 정화효율 및 BPT 특성에 관한 실험적 연구)

  • Oh, Kwang-Chul;Lee, Kyung-Bok;Lee, Chun-Beom
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.20 no.1
    • /
    • pp.147-154
    • /
    • 2012
  • The number of vehicles applied diesel engine are rapidly rising for fuel economy. Accompanying this trend, application of an after-treatment system is strictly required as a result of reinforced emission regulation. The Diesel Particulate Filter (DPF) system is considered as the most efficiency method to reduce particulate matter (PM) by car makers but also in retrofit market. In recently, various kinds of partial flow DPF are widely used for proper filtration performance and reducing of pressure drop but it is difficult to define the characteristics of these filters because the filtration mechanism is obscure according to the status of these systems. In this paper we investigated the characteristics of cell open type DPF according to the status of filter especially, PM loading. The PM loading mass in the p-DPF are predicted from increase of differential pressure of DPF and the trend of filtration efficiency so that we can measure filtration efficiency and Balance Point Temperature (BPT) of this p-DPF according to PM loading.

Verification of the Filter Media Applied to Filter Type Facility Considering the Treatment Efficiency Factor (여과형 시설에 적용되는 여재의 처리효율 영향인자를 고려한 실증화 평가)

  • Kim, Taeyoon;Lee, Junebae;Lee, Dongwoo;Shin, Hyunsuk;Kim, Hyunchul;Kwon, Soonchul
    • Journal of Korean Society on Water Environment
    • /
    • v.33 no.5
    • /
    • pp.572-579
    • /
    • 2017
  • Increased impervious surface caused by rapid urbanization serves to produce the discharge of non-point source pollutants such as total suspended solid (TSS). There exist various methods of removing TSS, including a filtration process using granular media (a well-known method to be practically used after the consideration of removal efficiency, clogging, and backwashing efficiency). To determine the TSS removal capability of the filter, we initially performed lab-scale experiments which assessed flow rates, influent concentrations, permeability co-efficients, the particular shapes of suspended solids and potential clogging, and also evaluated TSS removal efficiency when applied to filtration facility in a pilot-scale. In low filtration flux condition, the removal efficiency of suspended solids was more than 95 %, while decreased to 83% in high filtration flux. Regarding the clogging aspect of the experiment, total cumulative solids were loaded up to $19.15kg/m^2$, and TSS removal efficiency was noted to commence to decrease when the loaded solids exceeded $9.0kg/m^2$. It was also noted, however, that superior efficiency was maintained for six hours. In addition, for pilot-scale experiment, the removal efficiency was still high enough (83.4 %) for the solid concentration of 140 ~ 343 mg SS/L and after backwashing, head loss was recovered to 92 ~ 95 % during two hour filtration. With these results, It was confirmed that lifetime of the filter applied to the test was prolonged due to the high treatment efficiency and good backwashing efficiency for the cumulative solids load.

A Study on Filtration System Model and Comparative Performance Tests of Automotive (여과시스템 모델과 자동차 연료필터의 비교성능시험 연구)

  • 이재천
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.20 no.3
    • /
    • pp.194-201
    • /
    • 2003
  • This study presents the comparative filtration performance evaluation of automotive fuel filters based on the theory of Beta ratio. For the experiments, the fuel component's test stand incorporating the multi-pass filtration test circuit was developed. A mathematical description of filtration process in general was derived. And the theoretical basis of multi-pass test and the test procedure were described in detail. Experimental results revealed that domestic fuel filter tested could not maintain consistent Beta ratio, that is filtration efficiency, although it had the holding capacity of contaminants close to the specification at maximum pressure drop across the filter assembly. The results of experiments and simulations also showed that filtration system model could be refined including desorption ratio to estimate the variable Beta ratio in service life.