• Title/Summary/Keyword: Filtration Tests

Search Result 108, Processing Time 0.025 seconds

Treatment of Industrial Wastewater with High Concentration of Hydrocarbons Using Membrane Reactors

  • Bienati, B.;Bottino, A.;Comite, A.;Ferrari, F.;Firpo, R.;Capannelli, G.
    • Membrane Journal
    • /
    • v.17 no.2
    • /
    • pp.112-117
    • /
    • 2007
  • The application of membrane bioreactors for the depuration of wastewater coming from the washing of mineral oil storage tanks is described. Microfiltration hollow-fibre membranes were used in the submerged configuration. Filtration tests were carried out with a biomass concentration of about 15 g/L in order to assess the critical flux of the hollow fibre membrane used. Then particular care was taken in carrying out the performance runs in the sub-critical flux region. The reactor performance was very high, with removal efficiencies ranging between 93% and 97% also when the concentration of hydrocarbon was very high. Some kinetic parameters for the COD and the hydrocarbon removal were estimated.

A Study on the Improvement of Membrane Separation and Optimal Coagulation by Using Effluent of Sewage Treatment Plant in Busan

  • Jung, Jin-Hee;Choi, Young-Ik;Han, Young-Rip
    • Journal of Environmental Science International
    • /
    • v.22 no.10
    • /
    • pp.1353-1361
    • /
    • 2013
  • The objectives of this paper are the characterization of the pretreatment of wastewater by microfiltration (MF) membranes for river maintenance and water recycling. This is done by investigation of the proper coagulation conditions, such as the types and doses of coagulants, mixing conditions (velocity gradients and mixing periods), pH, etc., using jar tests. The effluent water from a pore control fiber (PCF) filter located after the secondary clarifier at Kang-byeon Sewage Treatment Plant (K-STP) was used in these experiments. Two established coagulants, aluminum sulfate (Alum) and poly aluminum chloride (PAC), which are commonly used in sewage treatment plants to treat drinking water, were used in this research. The results indicate that the optimal coagulation velocity gradients (G) and agitation period (T) for both Alum and PAC were 200-250 $s^{-1}$ and 5 min respectively, but the coagulation efficiencies for both Alum and PAC were lower at low values of G and T. For a 60 min filtration period on the MF, the flux efficiencies ($J/J_0$ (%)) at the K-STP effluent that were coagulated by PAC and Alum were 92.9 % and 79.9 %, respectively, under the same coagulation conditions. It is concluded that an enhanced membrane process is possible by effective filtration of effluent at the K-STP using the coagulation-membrane separation process.

Removal of Aerosol Through Fibrous Filter as a Function of Particle Size and Velocity (입자의 크기와 유속에 따른 섬유질 여과포에 의한 부유입자 제거 연구)

  • Sang Hoon Lee;Kwan Sik Chun;Hoo Keun Lee
    • Nuclear Engineering and Technology
    • /
    • v.16 no.1
    • /
    • pp.29-35
    • /
    • 1984
  • Filtration efficiency tests were conducted on a fiberglass mat filter with DOP aerosol having a diameter from 0.l${\mu}{\textrm}{m}$ to 0.45${\mu}{\textrm}{m}$ in the face velocity range of 1cm/sec to 10cm/sec. Filtration of submicron particles by a fibrous filter is characterized by a face velocity. The size of DOP aerosol which has a minimum removal efficiency decreases with increasing the velocity. A numerical solution of the diffusion equation is obtained for a fiberglass mat filter by using "Kuwabara's cell model" for the flow field and Von Mises Transformation for the actual flow around a fiberglass. The present theoretical results agree quite well with the experimentals for fiberglass mat. This result could be contributed to predict the removal efficiency on an air filter and to optimize the operating condition of an air purification system with a filter. a filter.

  • PDF

Effect of inlet structure of filtration system on the removal characteristics of iron particles by ceramic candle filters (집진장치의 유입구조에 따른 세라믹필터의 철입자 제거특성에 미치는 영향)

  • Park, Young-Ok;Jeong, Ju-Yeong;Seo, Yong-Chil
    • Particle and aerosol research
    • /
    • v.5 no.4
    • /
    • pp.189-197
    • /
    • 2009
  • Wet-type particulate removal system is employed in most of ironmaking processes. These de-dusting systems require additional downstream aggregates for treatment of water and for drying of the collected slurry. Thus dried slurry can be pressed in shape of briquettes and recycled in the steelmaking process. Different from the wet-type, the dry-type particulate removal systems generate no slurry. A high-temperature, high-pressure de-dusting system with inertial inlet was developed. The target application of this system was to remove particulate matter generated from the novel ironmaking process and other steelmaking processes. In this study we conducted tests with this newly developed system to evaluate the performance of the silica-carbide (SiC) ceramic filters. In addition, for purpose of comparison, we also conducted tests with a unit which has conventional direct inlet. Fe-Particles collected from the novel ironmaking process were used in our tests as test dusts. The temperature and the pressure were kept constant at their respective values $800^{\circ}C$ and $3kg_f/cm^2$.

  • PDF

An Experimental Study on Filtration Efficiency of Sand Filter Layers to TSS and COD in Non-point Source Pollutant (분산형 빗물 저류조용 모래 여과층을 적용한 도심지 비점오염원의 TSS와 COD 정화효율에 대한 실험적 연구)

  • Ahn, Jaeyoon;Lee, Dongseop;Han, Shinin;Choi, Hangseok
    • KSCE Journal of Civil and Environmental Engineering Research
    • /
    • v.34 no.5
    • /
    • pp.1477-1488
    • /
    • 2014
  • Prevalent construction of impermeable pavements in urban areas causes diverse water-related environmental issues, such as lowering ground water levels and shortage of water supply for the living. In order to resolve such problems, a rainwater reservoir can be an effective and useful solution. The rainwater reservoir facilitates the hydrologic cycle in urban areas by temporarily retaining precipitation-runoff within a shallow subsurface layer for later use in a dry season. However, in order to use the stored water of precipitation-runoff, non-point source pollutants mostly retained in initial rainfall should be removed before being stored in the reservoir. Therefore, the purification system to filter out the non-point source pollutants is essential for the rainwater reservoir. The conventional soil filtration technology is well known to be able to capture non-point source pollutants in a economical and efficient way. This study adopted a sand filter layer (SFL) as a non-point source pollutant removal system in the rainwater reservoir, and conducted a series of lab-scale chamber tests and field tests to evaluate the pollutant removal efficiency and applicability of SFL. During the laboratory chamber experiments, three types of SFL with the different grain size characteristics were compared in the chamber with a dimension of $20cm{\times}30cm{\times}60cm$. To evaluate performance of the reservoir systems, the concentration of the polluted water in terms of TSS (Total Suspended Solids) and COD (Chemical Oxygen Demand) were measured and compared. In addition, a reduction in hydraulic conductivity of SFL due to pollutant clogging was indirectly estimated. The optimum SFL selected through the laboratory chamber experiments was verified on the in-situ rainwater reservoir for field applicability.

Geochemical Characteristics of Groundwater during the Constant and Step-drawdown Pumping Tests at the River Bank Filtration Site (장기 및 단계 양수시험 시 강변여과 지하수의 수질변화 특성)

  • Kim, Gyoobum;Shin, Seonho;Kim, Byungwoo;Park, Joonhyung
    • Journal of the Korean GEO-environmental Society
    • /
    • v.14 no.8
    • /
    • pp.11-21
    • /
    • 2013
  • In-situ test to find the change of $Fe^{2+}$ and $Mn^{2+}$ concentrations and ion contents in groundwater was conducted during two pumping tests at the riverbank filtration site, where is the riverine area of the Nakdong River in Changnyeong-Gun. Groundwater was sampled at one pumping well and 10 monitoring wells during a 5 steps drawdown pumping test with the rates from $500m^3/day$ to $900m^3/day$ and a constant pumping test with $800m^3/day$. The change in ion concentration of groundwater was more remarkable during a step drawdown pumping test than a constant pumping test. Especially, the decrease in $Fe^{2+}$ and $Mn^{2+}$ concentrations was distinct in a step drawdown pumping test and it happens predominantly along the direction that the radius of pumping influence was small due to a good aquifer connectivity to a pumping position. The precipitation and the oxidation of iron and manganese were caused by an air inflow and a disturbance in groundwater flow due to an abrupt change in pumping rate. The pumping rate and spatial distribution of an aquifer around a pumping well need to be considered as an important factor for the development of in-situ iron and manganese treatment technology.

A Study on Glomerular Filtration Rate Comparisons between Gates Method and Modified Gates Method used in Dynamic Renal Scintigraphy (동적 신장 신티그래피 검사 시 사용되는 Gates 법과 Modified Gates 법의 사구체 여과율 비교에 관한 고찰)

  • Ham, Jun-Cheol;Bahn, Young-Kag;Park, Min-Soo;Cho, Seok-Won;Lim, Han-Sang;Kim, Jae-Sam;Lee, Chang-Ho
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.16 no.1
    • /
    • pp.96-101
    • /
    • 2012
  • Purpose: Glomerular filtration rate is an important index for assessment of renal function, early discovery of renal disease, and progress observation of chronic renal disease patients. In the present study, the objective is to conduct a comparative analysis of differences between Gates and Modified Gates method in dynamic renal scintigraphy based on MDRD (Modification of Diet Renal Disease) formula using blood collection. Materials and Methods: Renal scintigraphy was performed for 45 patients who visited our hospital between November 2010 and August 2011. For 20 patients of those tested, glomerular filtration rates from Gates method and MDRD formula using AGUS equipment, were compared. For the other 20 patients, glomerular filtration rates from Modified Gates method and MDRD formula using INFINIA equipment. Finally, Gates and Modified Gates method were compared for 5 patients who indicated no change in glomerular filtration rates from MDRD formula during progress observation. Results: Glomerular filtration rates from both Gates and Modified Gates method showed a high correlation with those from MDRD formula ($p$<0.01, r=0.903, r=0.867), with a paired difference mean for Gates method of $2.05{\pm}2.54mL/min/1.73m$, and that for Modified Gates method of $25.2{\pm}3.71mL/min/1.73m$. Finally, the values for Gates method and those for Modified Gates method showed a high correlation for the five patients ($p$<0.05, r=0.949), with a paired difference mean of $20.4{\pm}8.84mL/min/1.73m$. Conclusion: Glomerular filtration rates from Gates method, Modified Gates method and MDRD formula showed mutually high correlations. If the tests are performed with recognition for the correlations between Gates and Modified Gates method used in a dynamic renal scintigraphy, then an accurate assessment of renal function is considered possible with an improved diagnostic ability.

  • PDF

Water treatment sludge for removal of heavy metals from electroplating wastewater

  • Ghorpade, Anujkumar;Ahammed, M. Mansoor
    • Environmental Engineering Research
    • /
    • v.23 no.1
    • /
    • pp.92-98
    • /
    • 2018
  • Suitability of aluminium-based water treatment sludge (WTS), a waste product from water treatment facilities, was assessed for removal of heavy metals from an electroplating wastewater which had high concentrations of copper and chromium along with other heavy metals. Batch tests with simulated wastewater in single- and multi-metal solutions indicated the influence of initial pH and WTS dose on removal of six metals namely Cu(II), Co(II), Cr(VI), Hg(II), Pb(II) and Zn(II). In general, removal of cationic metals such as Pb(II), Cu(II) and Zn(II) increased with increase in pH while that of anionic Cr(VI) showed a reduction with increased pH values. Tests with multi-metal solution showed that the influence of competition was more pronounced at lower WTS dosages. Column test with diluted (100 times) real electroplating wastewater showed complete removal of copper up to 100 bed volumes while chromium removal ranged between 78-92%. Other metals which were present in lower concentrations were also effectively removed. Mass balance for copper and chromium showed that the WTS media had Cu(II) and Cr(VI) sorption capacities of about 1.7 and 3.5 mg/g of dried sludge, respectively. The study thus indicates that WTS has the potential to be used as a filtration/adsorption medium for removal of metals from metal-bearing wastewaters.

Conditioning and Dewatering Properties of Digested and Thickened Sludge with Inorganic Conditioner (무기개량제를 이용한 소화 및 농축슬러지의 개량 및 탈수 특성)

  • Kim, Jeong-Ho;Nam, Se-Yong
    • Journal of Environmental Health Sciences
    • /
    • v.37 no.6
    • /
    • pp.467-473
    • /
    • 2011
  • Objectives: Wastewater treatment plants typically produce a large volume of waste sludge. In this study, the conditioning and dewatering properties of a digested and thickened sludge from an industrial wastewater treatment plant were investigated in order to improve the dewaterbility of the sludge. Methods: Jar-tests and Buchner funnel tests were carried out to assess the conditioning and dewatering properties of a waste sludge. TTF (Time to Filter Test) and SRF (Specific Resistance to Filtration) were adopted as the indices of sludge dewaterbility. Results: The valuation indices influencing the dewaterbility of the waste sludge, including TTF, SRF, water contents, VS/TS ratio and turbidity, were measured. The TTF and SRF of the digested and thickened sludge were decreased to 40 sec, $3.43{\times}10^{12}$ m/kg, and 39 sec, $1.09{\times}10^{12}$ m/kg, respectively. Conclusions: The conditioner composed of natural inorganic materials turned out to be effective in the reduction of sludge water contents.

A Study on the Application of Spectrometric Methods for the Analysis of Lubricant Contaminants and Wear Debris (분광분석법을 이용한 윤활유 오염물 및 마모입자 분석에 있어서의 문제점 고찰)

  • 공호성;한흥구;권오관
    • Tribology and Lubricants
    • /
    • v.15 no.2
    • /
    • pp.131-140
    • /
    • 1999
  • This study dealt with some problems occurred in spectrometric oil analysis that has been popularly used for a machine condition monitoring in various fields of industry. One of the problems is that spectrometric technique could not analyze contaminants of large particle (larger than 10 $\mu\textrm{m}$) in lubricating oils. This limitation caused a serious problem in analyzing lubricated machine conditions since wear debris of large size represents better critical machine conditions. In this work, this problem was found to be solved by using a filtration method prior to spectrometric analysis. Another problem could be that spectrometric analysis is incapable of identifying contaminants. This nay mislead the result seriously in practice. This problem was surveyed by analyzing both various types of industrial lubricants and laboratory simulation tests, and the solutions to the problem were suggested in this work.