• Title/Summary/Keyword: Filtration Tests

Search Result 108, Processing Time 0.023 seconds

Drain Capacity of PVD Filter Considering the Field Condition (현장 토질특성을 고려한 연직배수재 필터의 성능평가)

  • Han, Sung-Su;Jeong, Kyeong-Han
    • Journal of the Korean Geosynthetics Society
    • /
    • v.6 no.1
    • /
    • pp.33-38
    • /
    • 2007
  • PVD (Prefabricated Vertical drain) consists of filter and core. An effective PVD has two basic filtration functions ; first to retain soil particle ; and second, to allow water to pass from the soil into the PVD core without clogging or blinding. Clogging which reduces the permeability of the geotextile filter jacket is caused by fine particles penetrating into the geotextile filter jacket in relatively low permeability soil conditions. As clogging performance increases gradually, excess pore water flow from soil is resisted and finally consolidation delays. Current soil-geotextile filter system criteria are generally based on relationships between a representative pore size of the geotextile and particle size of the soil. In Korea, PVD geotextile filter system criteria have been applied by only testing AOS (Apparent Opening Size) of filters without evaluating the filtration and clogging performance on soil-geotexile filter systems. Therefore, the filtration tests on soil-geotexile filter systems were conducted in order to evaluate the filtration and clogging performance with 3 kinds of geotextile filters. On these tests, we have applied geotextile filter system criteria on PVD in ${\bigcirc}{\bigcirc}$ sites.

  • PDF

THE EFFECT OF AIR BUBBLES FROM DISSOLVED GASES ON THE MEMBRANE FOULING IN THE HOLLOW FIBER SUBMERGED MEMBRANE BIO-REACTOR (SMBR)

  • Jang, Nam-Jung;Yeo, Young-Hyun;Hwang, Moon-Hyun;Vigneswaran, Saravanamuthu;Cho, Jae-Weon;Kim, In S.
    • Environmental Engineering Research
    • /
    • v.11 no.2
    • /
    • pp.91-98
    • /
    • 2006
  • There is a possibility of the production of the air bubbles in membrane pores due to the reduction in pressure during membrane filtration. The effect of fine air bubbles from dissolved gases on microfiltration was investigated in the submerged membrane bio-reactor (SMBR). The $R_{air}$ (air bubble resistance) was defined as the filtration resistance due to the air bubbles formed from the gasification of dissolved gases. From the results of filtration tests using pure water with changes in the dissolved oxygen concentration, the air bubbles from dissolved gases were confirmed to act as a foulant and; thus, increase the filtration resistance. The standard pore blocking and cake filtration models, SPBM and CFM, respectively, were applied to investigate the mechanism of air bubble fouling on a hollow fiber membrane. However, the application of the SPBM and CFM were limited in explaining the mechanism due to the properties of air bubble. With a simple comparison of the different filtration resistances, the $R_{air}$ portion was below 1% of the total filtration resistance during sludge filtration. Therefore, the air bubbles from dissolved gases would only be a minor foulant in the SMBR. However, under the conditions of a high gasification rate from dissolved gases, the effect of air bubble fouling should be considered in microfiltration.

Experimental Evaluation of Filter Performance of Depth Filter Media Cartridge with Varying the Pleat Count and the Cartridge Assembly Arrangement

  • Hasolli, Naim;Park, Young-Ok;Rhee, Young-Woo
    • Particle and aerosol research
    • /
    • v.8 no.4
    • /
    • pp.133-141
    • /
    • 2012
  • A new depth filter media was designed and samples of flat sheet as well as cartridge assembly were prepared and tested to evaluate the filtration performance and compare with the commercial product. The arrangement of the depth filter media layers is important to reach the optimal filtration parameters like filter pressure drop, particle collection efficiency and dust holding capacity. Initially, both flat sheet samples of new media and commercial product have been tested using standard test units. Tests with new depth filter media cartridges of various pleat count were conducted in order to find the optimal pleat count which would represent the lowest pressure drop. These tests give an insight on how the pleat count and the assembly configuration affect the performance of the depth filter media cartridge. By comparing the samples with a commercial product we could confirm relatively high filtration performance of the sample cartridge with pleat count 150 made of new depth filter media. The cartridge with the same pleat count exhibits better performance without the outer mesh.

Industrial dairy wastewater purification by shear-enhanced membrane filtration: The effects of vibration

  • Kertesz, Szabolcs
    • Membrane and Water Treatment
    • /
    • v.5 no.2
    • /
    • pp.73-86
    • /
    • 2014
  • Membrane fouling is a major challenge limiting the use of membrane applications. In this study high induced shear rates were utilized at the membrane surface in order to reduce the organic and inorganic scaling by using the torsional vibration of flat sheet membranes. The performances of a vibratory shear-enhanced processing (VSEP) system for the ultrafiltration (UF), nanofiltration (NF) and reverse osmosis (RO) membrane filtration of industrial dairy wastewater were investigated. The vibration and non-vibration methods were compared with the same membrane and operational parameters during the purification of real dairy industrial process wastewater. In the initial experiments, short-term tests were carried out in which the effects of vibration amplitude, recirculation flow rate and transmembrane pressure were measured and compared. The permeate flux, turbidity, conductivity and chemical oxygen demand (COD) reduction of dairy wastewater were investigated by using UF, NF and RO membranes with vibration and non-vibration methods. In the subsequent experiments, concentration tests were also carried out. Finally, scanning electron microscopy (SEM) revealed that the vibration method gave a better performance, which can be attributed to the higher membrane shear rate, which reduces the concentration of solids at the membrane, and the transmission.

Experimental determination of design parameters for filtration trench using phosphorus removal granular materials (인 제거 입상소재를 적용한 여과수로 설계인자의 실험적 결정)

  • Jang, Yeoju;Lim, Hyunman;Jung, Jinhong;Ahn, Kwangho;Chang, Hyangyoun;Park, Nari;Kim, Weonjae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.33 no.1
    • /
    • pp.9-16
    • /
    • 2019
  • The algal blooms in stagnant streams and lakes have caused many problems. Excessive algae leads to disturbance of ecosystem and overload of water treatment processes. Therefore, phosphorus(P), source of algal blooms, should be controlled. In this study, a filtration trench has been developed to convert dissolved phosphorus into hydroxyapatite(HAP) so that it could be crystallized on the surface of 'phosphorus removal granular material'; and residual particulate phosphorus could be removed by additional precipitation and filtration. The front and rear parts of filtration trench consisted of 'phosphorus removal granular material contact bed' and 'limestone filtration bed', respectively. As a result of the column test using phosphorus removal granular material and limestone serially, $PO_4-P$ was removed more than 90% when EBCT(empty bed contact time) of the contact bed was over 20 minutes; and T-P represented 60% of removal efficiency when total EBCT was over 1.5 hours. The results of column tests to figure out the sedimentation characteristics showed that more than 90% of particulate phosphorus could be removed within 24 hours. It was necessary to optimize the filtration part in order to increase removal efficiency of T-P additionally. Also, it was confirmed through the simulation of Visual MINTEQ that most of particulate phosphorus in the column tests is the form of HAP. Based on the results of the study, it could be suggested that the design parameters are over 0.5 hour of EBCT for phosphorus removal granular material contact bed and over 1.5 hours of EBCT for limestone filtration bed.

Performance of the Exhaust Filtration System of Hot Cell at PIEF (조사후시험시설에서의 핫셀 배기포집시스템의 성능평가)

  • Hwang, Yong-Hwa
    • Korean Journal of Air-Conditioning and Refrigeration Engineering
    • /
    • v.23 no.12
    • /
    • pp.799-804
    • /
    • 2011
  • Radioactivity of high concentrations have existed in the handling nuclear materials in hot cell of PIEF(Post Irradiation Examination Facility). The exhaust filtration system was enabled to process cylindrical filters by using a manipulator in the hot cell. By establishing a double filtration system with two filters, backup protection against leakage or failure of the first is provided by the second filter. Additionally, this a arrangement is arrange intended to increase the total filtration efficiency. The result of the pressure drop changing in the air flow of the cylindrical and HEPA filters is observed by a curved line. A filtering efficiency of more than 99.99% to $0.3{\mu}m$ particle appears in the upstream and downstream during the efficiency test on the HEPA filters. The V-pleats type had a lower pressure drop than the separator type. There was no damage during usage and was found to be suitable with high capacity of air volume. Therefore, by carrying out performance tests of the exhaust filtration system, efficiency and safety can be achieved.

Study on the Particulate Matter Filtration Characteristics of the Metal Foam Particulate Filter (메탈 폼 입자 필터의 GDI 엔진 입자상 물질 정화 특성에 대한 연구)

  • Jang, Wonwook;Myung, Cha-Lee;Lee, Jeongmion;Park, Simsoo
    • 한국연소학회:학술대회논문집
    • /
    • 2014.11a
    • /
    • pp.347-348
    • /
    • 2014
  • After-treatment system for gasoline direct injection engines should be considered due to the regulation standard for particle number emitted from spark ignition engine vehicles. A metal foam particulate filter, which is thought to be more proper for gasoline engines for its unique filtration and heat resistance characteristics, has been evaluated via engine dynamometer tests.

  • PDF

Effects of Mixing Condition and Filtration Velocity on Turbidity Removal in a Contact Roughing Filter (접촉여과방식 거친여과지에서 혼화조건과 여과속도가 고탁도 제거에 미치는 영향)

  • Park, Noh-Back;Park, Sang-Min;Hong, Jin-Ah;Jun, Hang-Bae
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.21 no.3
    • /
    • pp.359-366
    • /
    • 2007
  • Slow sand filtrations have been widely used for water treatment in small communities, however their capacity is often limited by high turbidity in the raw water. For this reason, several pre-treatment facilities were required for a slow sand filter. Turbidity removal from the highly turbid raw water was investigated in roughing filters as a pre-treatment process. The roughing filters followed by rapid mixing tank were operated in the form of a contact filtration. In several jar tests, the predetermined optimum aluminium sulfate (alum) doses for turbid water of 30 and 120NTU were 30 and 50mg/L, respectively. At the optimum alum dose, physically optimum parameters including G value of $220sec^{-1}$ and rapid mixing time of 3 minutes were applied to the contact filtration system. Without addition of alum, the filtrate turbidity from the roughing filters, packed respectively with different media such as sand, porous diatomite ball and gravel, was in the range of 5~30NTU at filtration velocities of 30 and 50m/day. However, the application of a contact filtration to roughing filters showed stably lower filtrate turbidity below 1.0NTU at filtration velocity of 30 m/day. Although the filtration velocity increased to 50m/day, filtrate turbidity was still below 1.0NTU in both single and double layer roughing filters. At influent turbidity of 120NTU, the filtrate turbidity was over 5 NTU in the triple layer roughing filter, which shortened the filter run time. The flocs larger than $10{\mu}m$, formed in the rapid mixing tank, were almost captured through the roughing filter bed, while the almost flocs smaller than $10{\mu}m$ remained in filtrate.

Reduction of Suspended Solids in First Flush from a Building Rooftop using Various Media (여과재를 활용한 건물옥상유출 초기빗물의 부유물질 저감)

  • Kim, Seongbeom;Lee, Wontae
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.214-219
    • /
    • 2017
  • We analyzed the water quality of first flush and rainfall runoff from a building rooftop, and investigated the removal of suspended solids (SS) in first flush using various media to develop a first flush filtration system. Particle size distribution exhibited most of particles in first flush from the rooftop ranged from 10 to 30 ${\mu}m$. SS concentrations maxed in 10~20 min and decreased afterwards. Dissolved organics and inorganic materials in runoff also showed highest levels in first flush (10 min). Filtration tests using anthracite (AC), polyurethane (PU), polypropylene (PP) showed about 50% of SS removal during the first 10 min operation, but the removal rates dramatically decreased after 20 min of filtration. Based upon the results from rinse and run cycle tests, only AC could achieve nice cycles without distinct decease of SS removal. SS removal rates increased with higher depth of media bed and lower flowrate. The system achieved over 50% of SS removal with a media depth of 30 cm and flowrate < 12 L/min.

An Internet Survey and Comparative Wearing Test of Commercial Health Masks (시판 보건용 마스크의 인터넷 조사 및 비교 착용 실험)

  • Kyong-Hwa Yi;Hayoung Song
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.48 no.3
    • /
    • pp.417-432
    • /
    • 2024
  • This study aimed to enhance the comfort of health masks by conducting in-depth interviews, online surveys, and wearing tests on commercial health masks. The findings are summarized below. In-depth interviews revealed that the most comfortable mask styles were ranked as follows: Beak-1 (B-1) & Beak-2 (B-2) style > Flat style > 3-Horizontal foldable (3H) style. Men generally preferred flat style masks, while women favored beak-shaped masks. The internet survey results showed that 77.8% of surveyed brands offered a variety of mask styles, with 3H and B-2 masks being the most common. Different brands provided masks with different filtration levels, ranging from KF-AD to KF94. Size consistency also varied among brands, with flat masks having relatively consistent dimensions and B-2 masks showing significant size differences. Wearing tests indicated that 3H and B-1 masks were highly satisfying for categories like "itchiness," "unpleasant odor," and "mask slipping." Conversely, flat masks scored the highest satisfaction in classifications such as "stiff," "heavy," "thick," "hot while wearing it," "moisture accumulation," "breathing discomfort," "short ear straps," and "itchiness". Overall, the flat style, B-1, and B-2 yielded higher satisfaction levels, while 4-Horizontal foldable (4H) and 3H garnered lower satisfaction scores on wearing tests.