• Title/Summary/Keyword: Filter-aids

Search Result 38, Processing Time 0.029 seconds

The Radar Data Correction of the onto the Application of a Complementary Filter for the Handicapped Aids (상보필터 적용을 통한 장애인보조기구용 레이더 데이터 보정연구)

  • Park, Dong-Jin;Ryu, In-Hwan;Lee, Sang-Min;Kwon, Jang-Woo
    • Journal of rehabilitation welfare engineering & assistive technology
    • /
    • v.10 no.1
    • /
    • pp.29-35
    • /
    • 2016
  • This paper presents an analysis of the short-range radar noise adjusting the angle of the radar reflector for the handicapped aids and suggests a complementary filter that combines a moving average filter with a heuristic algorithm to remove the radar noise. It also shows the effectiveness of the suggested filter by comparing the experiments results between the Kalman filter and the suggested filter.

Characteristics of Filtration Treatment Using Diatomite Filter Aids for Sewage Water Reuse (하수처리수 재이용을 위한 가압식 규조토 여과의 처리성능평가)

  • Lim, Byung Ran;Kim, Hee Seo;Go, Yeon Sil;Kim, Hyun Kab;Kim, Jong Hak;Lee, Tae Jin
    • Journal of Korean Society on Water Environment
    • /
    • v.35 no.2
    • /
    • pp.145-151
    • /
    • 2019
  • The purpose of this study was to investigate treatment characteristics of diatomite filtration, that would allow water recovery from biologically-treated effluent for reuse. Diatomite, Celpure 100, and acid clay were used as filter-aids, with a support filter manufactured from polyethylene (PE), and polypropylene (PP). This pre-coating process using diatomite filter-aids, is used in the filtration range of pressure filters, and has consistently provided high-quality separation. The results showed that variations in average removal efficiency of SS, and T-P from biologically treated effluent by the diatomite-coated PE filter, were approximately 82.2 ~ 88.9 % and 4.8 ~ 21.1 %, respectively. T-P treatment efficiency of the PP filter pre-coated with diatomite and $Celpure^{(R)}100$ at $57.64g/m^2$, was approximately $24{\pm}10%$ and $40{\pm}15%$ on average, respectively. Particle size distribution of secondary effluent varied from 0.05 to $200{\mu}m$, and $d_{50}$ value was $20.76{\mu}m$. The size distribution of particles in the diatomite filtrate ranged from 1.26 to $101.1{\mu}m$ when pre-coated with diatomite filter-aid, at a content of $57.64g/m^2$. Diatomite filter aids, i.e., the particles that form the pre-coating layer, capture very fine particles as well as macromolecules, owing to their complex structure with numerous fine microscopic pores, and surface properties. The filtration process using diatomite and $Celpure^{(R)}100$ as filter aids, has been successfully applied, to recover water from sewage for reuse. The disadvantage of the process, is that the particle size of the filter-aid is spent, because of pressurization.

Characteristics of High-Rate Filtration with Filtration Aids (급속여과공정에서의 여과보조제 사용에 따른 여과특성)

  • Ahn, Jong-Ho;Yoon, Jae-Heung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.14 no.3
    • /
    • pp.260-270
    • /
    • 2000
  • The objective of this study is to evaluate the effect of filter aids in the dual-media rapid filtration. Paper-filter tests were conducted to determine the proper dosages of coagulant and filter aid, and pilot plant tests using two dual-media filter columns were performed for a variety of filtration rates. Using a filter aid (non-ionic polymer), the maximum feasible filtration rate is 480m/day, while turbidity is less than 0.3 NTU and filter run-time is about 70 hours. It is possible to increase the filtration rate up to 360 m/day for keeping the turbidity less than 0.1 NTU. Turbidity increases for the filtration rate greater than 360m/day. In general, the quality of filtered water with a filter aid is stable, while the filter maintains a sufficient filter run-time for a maximum allowable head loss. Particularly, the initial breakthrough can be effectively controlled. The use of a filter aid may be one of the methods applicable if the turbidity of filtered water is required to be improved or if the filter breakthrough limits filter run-time.

  • PDF

Design of an Adaptive Filter for GPS/GLONASS Aided Inertial Navigation System (GPS/GLONASS 보정 관성항법시스템의 적응필터 설계)

  • 박흥원;제창해;정태호;박찬빈
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.1 no.1
    • /
    • pp.201-210
    • /
    • 1998
  • Inertial Navigation System(INS) can provide the vehicle position and velocity information using inertial sensor outputs without the use of external aids. Unfortunately INS navigation error increases with time due to inertial sensor errors, and therefore it is desirable to combine INS with external aids such as GPS, TACAN, OMEGA, and etc.. In this paper we propose an integration algorithm of commercial GPS/GLONASS and INS where an adaptive filter for signal processing of GPS/GLONASS receiver and the 12th order Kalman filter for aided strapdown INS(SDINS) we employed. Simulation results show that the proposed adaptive filter can effectively remove a randomly occurring abrupt jump due to sudden corruption of the received satellite signal and that the Kalman filter performs satisfactorily.

  • PDF

The Improvement of Water Quality by Using Filter-aids in Rapid Sand Filters (급속모래여과 공정에서의 여과보조제에 의한 수질개선효과 연구)

  • 김형선;이규성;백영매;조춘구
    • Journal of Environmental Health Sciences
    • /
    • v.27 no.4
    • /
    • pp.15-24
    • /
    • 2001
  • The objective of this study it to evaluate the microbial safety in rapid sand filters adapted in most drinking water treatment plants. The potential pathogens to cause water quality problems Are presumed to be Giardia and Gryptosporidium. They look like particles in view of their size. It has been reported that if the number of particles (larger than 2 ${\mu}{\textrm}{m}$ in water) is less than 100 per mL and its turbidity is below 0.1 NTU, it is considered as a safe water in terms of pathogens. In order to achieve such a good water quality. filter-aids (chemicals) were added to the inlet-channel of filter and their effectiveness was evaluated on the basis of water quality factors such as turbidity and particle counting. This study was conducted in she three steps of experiment: jar test. pilot plant test and real water treatment plant test (P plant in seoul). The experiment reult of the P water treatment showed that cationic polyamine was the most effective in the removal of particles and turbidity at the does of 0.25 mg/L. The turbidity without filer-aids showed in the range of 0.12 ~0.17 NTU during filtration and 0.14 NTU on the average. However. with addition of polyamine, the turbidity represented below(or less than) 0.1 NTU after 20 min in the start of filtration and kept 0.08 NTU on the average. On the other hand, as for number of particles, while no filter-aids led to the range of 111 ~270 per mL and 190 on the average, addition of polydmine led to 113 per mL on talc average, and kept below100 per mL after 20 min in the start of filtration.

  • PDF

Optimization of Extraction and Clarification Condition for Preparation of Liquid Extract Tea from Artificially Cultivated Phellinus linteus (인공재배 상황버섯 액상추출차 제조를 위한 최적추출 및 청징화 조건)

  • Song, Hyo-Nam;Oh, Se-Wook
    • Journal of the Korean Society of Food Science and Nutrition
    • /
    • v.31 no.4
    • /
    • pp.636-641
    • /
    • 2002
  • Optimum extraction condition and clarification process were investigated to manufacture liquid extract tea using Phellinus linteus. Carbohydrates content in the raw Phellinus linteus was 80.9%. Major minerals were K, Ca, Fe and Na, but vitamin B$_1$, B$_2$, and C were not detected. The best extraction condition was 5% raw material at 10$0^{\circ}C$ within 3 hr. To clarify the extract, three methods of filtration with depth filter pad, centrifugation and addition of several filter aids were studied. Filtration with depth filter pad and centrifugation were highly effective on the clarification and the changes in the turbidity for 7 weeks at 4$0^{\circ}C$ were not occurred. The optimum clarification condition was centrifugation above 6,000 rpm or filtration with 8 ${\mu}{\textrm}{m}$ depth filter pad.

Design and performance analysis of a zero-velocity update Kalman filter for SDINS (SDINS의 영속도 보정 칼만필터 설계)

  • 박흥원;정태호;박찬빈;이장규
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1988.10a
    • /
    • pp.633-638
    • /
    • 1988
  • In this paper, a zero-velocity update technique to improve navigation accuracy of a SDINS(Strapdown Inertial Navigation System) has been studied. An indirect feedback Kalman filter which includes SDINS error equations based on a quaternion between body-fixed frame and local level navigation frame is employed for processing zero-velocity updates in an on-board navigation filter. Simulation results for land-mobile vehicle show that the zerovelocity update technique make a significant contribution to improving SDINS performance without any external aids.

  • PDF

Improvement for Hearing Aids System Using Adaptive Beam-forming Algorithm (적응 빔포밍 기법을 적용한 보청기 시스템의 성능 향상에 관한 연구)

  • 이채욱;오신범
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.29 no.5C
    • /
    • pp.673-682
    • /
    • 2004
  • The adaptive beam-forming is promising approach for noise reduction in hearing aids. This approach has come in the focus of interest only recently, because of the availability of new and powerful digital signal processors. The adaptation U using usually a Least Mean Squares algorithm, updates the weight vector. In this Paper, we propose a fast wavelet based adaptive algorithm using variable step size algorithm which varies adaptive constant by the change of signal environment. We compared the performance of the proposed algorithm with the known adaptive algorithm using computer simulation of multi channel adaptive bemformer in hearing aids. As the result the proposed algorithm is suitable for adaptive signal processing area using hearing aids and has advantages reducing computational complexity. And we show the beam-forming system using proposed algorithm converges stably in a sudden change of system environment.

An Adaptive Feedback Canceller for Fully Implantable Hearing Device Using Tympanic Membrane Installed Microphone (고막이식형 마이크로폰을 위한 이식형 인공중이 적응 피드백 제거기 구현)

  • Kim, Tae Yun;Kim, Myoung Nam;Cho, Jin-Ho
    • Journal of Korea Multimedia Society
    • /
    • v.19 no.2
    • /
    • pp.189-199
    • /
    • 2016
  • Many implantable hearing aids are being developed as alternatives to conventional hearing aids which has inconveniences for use and social stigma that make hearing-impaired people avoid to wear it. Particularly, the fully-implantable middle ear hearing devices (F-IMEHD) are being actively studied for mixed or sensorineural hearing impaired people. In development of F-IMEHD, the most difficult problem is improving the performance of implantable microphone. Recently, Cho et al. have studied the tympanic membrane installed microphone which has better sensitivity and is easier to operate on patient than the microphone implanted under the skin. But, it may cause howling problem due to the feedback signal via oval window and ossicle chain from the transducer on round window in the middle ear cavity, therefore, a feedback canceller is necessary. In this paper, we designed NLMS (normalized least mean square) adaptive feedback canceller for F-IMEHD with tympanic membrane installed microphone and a transducer implemented at round window, and computer simulation was performed to verify its operation. The designed adaptive feedback canceller has a delay filter, a 64 point FIR fixed filter and a 8-tap adaptive FIR filter. Computer simulation of the feedback path is modeled by using the data obtained through human cadaver experiment.

Development of Adaptive Feedback Cancellation Algorithm for Multi-channel Digital Hearing Aids (다채널 디지털 보청기를 위한 적응 궤환 제거 알고리즘 개발)

  • 이상민;김상완;권세윤;박영철;김인영;김선일
    • Journal of Biomedical Engineering Research
    • /
    • v.25 no.4
    • /
    • pp.315-321
    • /
    • 2004
  • In this study, we proposed an adaptive feedback cancellation algorithm for multi-band digital healing aids. The adaptive feedback canceller (AFC) is composed of an adaptive notch filter (ANF) for feedback detection and an NLMS (normalized least mean square) adaptive filter for feedback cancellation. The proposed feedback cancellation algorithm is combined with a multi-band hearing aid algorithm which employs the MDCT (modified discrete cosine transform) filter bank for the frequency-dependent compensation of hearing losses. The proposed algorithm together with the MDCT-based multi-channel hearing aid algorithm has been evaluated via computer simulations and it has also been implemented on a commercialized DSP board for real-time verifications.