• Title/Summary/Keyword: Film holder

Search Result 43, Processing Time 0.034 seconds

Influence of Flame Holder on Film Cooling Effectiveness of Ramjet Combustor (화염안정기 형상이 램제트 연소실에서의 슬롯 막냉각 특성에 미치는 영향)

  • Lee, Keon-Woo;Song, J.;Cho, Hyung-Hee;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.315-320
    • /
    • 2008
  • This experimental study has been conducted to investigate the effect of the flame holder on the multi-slot film cooling in the ramjet combustor. The turbulent wake which is generated by the flame holder on the entrance of the coolant flow path affects on the slot. Adiabatic film cooling effectiveness on the downstream wall of the slot exit are measured. The results show that the film cooling performance is rapidly decreased after the slot exit by shear layer and high turbulence intensity between separated flows and coolant flows.

  • PDF

Influence of the Vertical Flame holder on Heat Transfer Characteristics of Ramjet Combustor (세로축 화염안정기 형상이 램제트 연소실에서의 열전달 특성에 미치는 영향)

  • Yang, Kang-Mo;Lee, Keon-Woo;Song, Ji-Woon;Cho, Hyung-Hee;Hwang, Ki-Young
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.11a
    • /
    • pp.305-309
    • /
    • 2008
  • This experimental study has been conducted to investigate the installation of the vertical flame holder shape in ramjet combustor, which affects on the film cooling effectiveness. All slot position, the film cooling effectiveness decreases because of the shear layer and high turbulence intensity between separated flows and coolant flows. When the flame holder is installed, film cooling effectiveness decreases abruptly on the beginning of the slot exit region due to the mixing effect. As the blowing rate increases, the film cooling effectiveness is increased for all cases due to the augmented momentum of injected coolant from the slot.

  • PDF

Arm-up holder의 보조기구 제작에 따른 유용성 평가

  • 이현직;최병기;심재구;김종식;오동균;박영환
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.14 no.1
    • /
    • pp.85-88
    • /
    • 2002
  • I. 목적 : arm-up holder는 흉부 및 복부 질환 치료의 환자고정에 유용하게 사용하고 있으나 손잡이 부분과 어깨가 닿는 부분까지 거리 때문에 동일한 자세를 유지하는데 불편함이 있다. 특히 긴장을 많이 하거나 기력이 없는 환자는 방사선 치료 시 자세의 불안정으로 인하여 치료의 정확성이 떨어질 수 있다. 이에 본원에서는 현재 사용하고 있는 arm-up holder에 팔의 지지를 위한 보조기구를 제작하여 유용성을 평가하였다. II. 대상 및 방법 : 기존의 arm-up holder에 어깨받침대를 부착하여 개선된 arm-up holder를 제작하였다. 실험을 위하여 기존의 arm-up holder를 사용하는 환자그룹과 개선된 arm-up holder를 사용하는 그룹으로 구분하여 자세 변화를 평가하였다. 두 그룹의 환자를 대상으로 모의 치료를 실시한 후 치료실에서 L-gram 을 2회 씩 촬영하여 치료하고자 하는 portal film과 isocenter의 변화를 측정했다. 각 그룹 당 10명씩의 환자를 선정하여 반복 조사하였다. III. 결과 : 개선된 arm-up holder를 사용한 그룹의 isocenter 의 변화는 최대 2mm, 최소 0.5mm 평균 1.2mm 이다. 기존의 arm-up folder를 사용한 그룹과 비교하여 평균변화는 약 2배로 나라났고, 최대 변화는 2.5배의 오차범위가 측정되었다. IV. 결론 : 현재 사용하고 있는 arm-up holder는 흉부 및 복부의 사방향 방사선 치료 시 팔에 의한 방사선 감약을 예방할 수 있는 유용한 고정용구이다. 하지만 팔을 올리고 있는 자세는 환자에게 불편함을 야기 시키며 이로 인한 치료의 정확성을 감소시킬 수 있다. 따라서, 기존의 arm-up holder에 보조기구를 제작하여 사용함으로써 환자의 불편함을 개선하고, set-up 의 안정성과 재현성을 향상시킬 수 있었다.

  • PDF

A STUDY OF THE SUTURAL FACIAL BONE GROWTH OF RABBIT : SERIAL ROENTGENOGRAPHIC STUDY BY MEANS OF MEANS OF IMPLANTS (금속매식법(金屬埋植法)에 의(依)한 가토(家兎)의 봉합성(縫合性) 안면골성장(顔面骨成長)에 관(關)한 X-선학적(線學的) 연구(硏究))

  • Lee, Won Chul
    • The korean journal of orthodontics
    • /
    • v.9 no.1
    • /
    • pp.23-35
    • /
    • 1979
  • The present study has the purpose of investigating various growth and developmental aspects of rabbit snout with the aid of metallic implantation and of improving on the indirect method of growth and developmental studies of its skull. Sixty-eight growing albino rabbits were used. A head holder, film holder, cephalometer, metallic implanting device and implant materials were designed and constructed by the author. Eight metallic pins were implanted with a metallic implanting device in the rabbit snout under general anesthesia. Two metallic pins were implanted on each side of the interfrontal suture and another two were put on each side of the internasal suture near the frontonasal suture. Serial cephalograms were taken with a two-week interval, using the head holder, film holder and cephalometer. Eight items of linear measurement were obtained from the film. On the base of the results of the study, the following conclusions are obtained: 1. The metallic implant method is better than the other indirect methods for growth and developmental studies of the rabbit skull. 2. Most of the vertical growth of the rabbit snout is due to sutural growth at the frontonasal suture and the horizontal growth is at the interfrontal and the internasal suture. 3. The vertical growth of the rabbit snout is greater than the horizontal growth. 4. The horizontal growth of the rabbit snout is greater at the nasal bone than at the frontal bone. 5. The amount of vertical growth of the rabbit snout is almost same at inner and outer side of the interfrontal and internasal suture line, 6. Growth rate of the sutural growth of the rabbit snout tends to decrease by the growth of the rabbit. 7. Implant materials do not disturb growth and development of the rabbit snout, except a slight trauma effect during the first week of metallic implantation.

  • PDF

Fabrication of a 18cm long YBCO coated conductor using a cylindrical tape holder in a double chamber co-evaporation system (이중 챔버를 가진 동시증발 시스템 내에서 실린더 홀더를 이용한 18cm 길이의 YBCO coated conductor의 제작)

  • Oh, Sang-Hyun;Jung, Kook-Chae;Youm, Do-Jun
    • 한국초전도학회:학술대회논문집
    • /
    • v.9
    • /
    • pp.322-325
    • /
    • 1999
  • We fabricated 18cm YBCO coated conductor comprising a YBCO superconducting film and CeO$_2$/YSZ/CeO$_2$ buffer films deposited on a biaxially textured Ni tape. For those film fabrications, we developed a new method, the cylindrical holder in a double chamber. This is alternative to the reel-to-reef method which is commonly tried to fabricate a long YBCO coated tape. We will discuss about the superconducting properties of the 18cm long YBCO coated tapes.

  • PDF

저 염소 TiN필름 제조를 위한 CVD 반응기 내의 유동해석

  • 임익태;전기영
    • Proceedings of the Korean Society Of Semiconductor Equipment Technology
    • /
    • 2003.12a
    • /
    • pp.1-6
    • /
    • 2003
  • Flow modulation chemical vapor deposition process has been reported as an alternative way to obtain low resistivity, low residual chlorine content and good step-coverage titanium nitride film. Flow and concentration characteristics in a vertical FMCVD reactor are analyzed by using computational fluid dynamics method. The results show that 1.0 second as Cl reduction period is too short and there is still $TiCl_4$ gas above the holder at the end of the period. Time variation of $TiCl_4$ gas concentration on the holder shows that at least 3.0 second is necessary as Cl reduction time for the sake of film characteristics.

  • PDF

Contrast and geometric correction of non-standardized radiographs in digital subtraction radiography (디지털 공제술에서 비표준화 방사선사진의 대조도 및 기하학적 보정에 관한 연구)

  • Kim, Eun-Kyung
    • Journal of Periodontal and Implant Science
    • /
    • v.28 no.4
    • /
    • pp.797-809
    • /
    • 1998
  • The purposes of this study were to develop the computer program for the contrast and geometric correction in digital subtration radiography with the IDL (Interactive Data Language) and compare the results with this program for the correction of the non-standardized radiographs to those of standardized radiographs and those with "Emago" software, the commercial program for the correction. The procedures were written for the contrast correction and subtraction with the geometric correction, using IDL. 32 pairs of periapical radiographs of premolar and molar portion of two dry human mandibles were taken at two different occasions with XCP film holder(nonstandardized films) and another 32 pairs with customized XCP film holder(standardized films). Subtraction of standardized film pairs was performed. Subtraction after the contrast and geometric correction of non-standardized films was performed using the newly developed program and Emago software. Standard deviations of grey levels of the subtracted images by the newly developed program were compared with those of the standardized group and Emago-corrected group. Standard deviations of grey levels of new program-corrected group were much smaller than those of the Emago-corrected group (p<0.001) and slightly larger than those of standardized group (p<0.05). However, the difference was very minute. This study indicates that the newly developed program written with IDL may substitute the mechanical standardization for digital subtraction radiography.

  • PDF

New Fiduciary Plate and Orientation Marker for High Energy Radiation Therapy (고에너지 방사선치료의 정도관리를 위한 Fiduciary Plate 및 Orientation Marker의 개발)

  • Wu Hong-Gyun;Huh Sun Nyung;Kim Hak Jae
    • Radiation Oncology Journal
    • /
    • v.22 no.1
    • /
    • pp.69-75
    • /
    • 2004
  • Purpose : A new fiduciary plate and orientation marker have been devised to assist the quality assurance (QA) procedures for port films in radiation therapy department. The plate is used in conjunction with the film/cassette combination during weekly QA procedures, at Seoul National University Hospital (SNUH), in order to verify treatment fields in high radiation therapy. Materials and Methods : A new fiduciary plate was fabricated using an acrylic plate, cerrobend, standard blocking tray and mercury. The acrylic plate had the dimension of $1{\times}25{\times}25$ cm, with two fiduciary markers. The plate was rigidly attached onto the standard blocking tray, thus making it easier to set the fiduciary plate to the center on the radiation field on the linear accelerator. The plate had two 2-mm vertical and horizontal lines, with the minor scales in 2-cm steps. The orientation marker was a small mercury filled disk, which was inserted into the plate. Results : The geometrical structure of the lines in the plate makes it easier to correlate two different images between the simulation and port films. The marker clearly indicated the orientation of the film, for example, the anterior, posterior, left, right and various oblique orientations, without the placement of a conventional orientation marker. Also, the new orientation marker could easily be applied to the simulator by placing the small orientation marker onto the image intensifier or in front of the film/cassette holder. Conclusions : The new fiduciary plate appears to be useful in verifying the treatment fields, and the new orientation marker makes the film orientation simple, which is expected to lower the block fabrication errors.

Development of High Aspect Ratio Spacer Process using Anodic Bonding for FED (정전접합을 이용한 고종횡비의 FED용 스페이서 공정 개발)

  • Kim, Min-Su;Kim, Gwan-Su;Mun, Gwon-Jin;U, Gwang-Je;Lee, Nam-Yang;Park, Se-Gwang
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.49 no.1
    • /
    • pp.70-72
    • /
    • 2000
  • In this paper, a spacer process for FED(Field Emission Display) was developed with the glass to glass anodic bonding technology using Al film as an interlayer and a 3.5 inch monochromatic type FED was fabricated. Holder to dislocate spacers vertically was designed with (110) Si wafer by bulk etching. Spacers, $100\mum\; width\; and\; 1000\mum$ height, were formed on anode panel by spacer to glass anodic bonding and the fabricated FED was operated for emission at 1㎸ anode voltage.

  • PDF