• 제목/요약/키워드: Film Winding Core

검색결과 10건 처리시간 0.03초

Current Limiting Characteristics of a Flux-Lock Type SFCL for a Single-Line-to-Ground Fault

  • Oh, Geum-Kon;Jun, Hyung-Seok;Lee, Na-Young;Choi, Hyo-Sang;Nam, Gueng-Hyun
    • 조명전기설비학회논문지
    • /
    • 제20권9호
    • /
    • pp.70-77
    • /
    • 2006
  • We have fabricated an integrated three-phase flux-lock type SFCL, which consists of an YBCO($YB_a2Cu_3O_7$) thin film and a flux-lock reactor wound around an iron core of each phase. In order to apply the SFCL in a real power system, fault analyses for the three-phase system are essential. The short-circuit currents were effectively limited by adjusting the numbers of winding of each secondary coil and their winding directions. The flux flow generated in the iron core cancelled out under the normal operation due to the parallel connection between primary and secondary windings. However, the flux-lock type SFCL with same iron core was operated just after the fault due to the flux generating in the iron core. To analyze the current limiting characteristics, the additive polarity winding was compared with the subtractive one in the flux lock reactor. Whenever a single line-to-ground fault occurred in any phase, the peak value of the line current of the fault phase in the additive polarity winding increased up to about 12.87 times during the first-half cycle. On the other hand, the peak value in the subtractive polarity winding increased up to about 34.07 times under the same conditions. This is because the current flow between the primary and the secondary windings changed to additive or subtractive status according to the winding direction. We confirmed that the current limiting behavior in the additive polarity winding was more effective for a single-line-to-ground fault

미 군사규격을 적용한 권취 코어 자동공급장치의 진동해석 (Vibration Analysis of Film Winding Core Automatic Supply System Using US Military Standards)

  • 고정일;박수현;허장욱
    • 한국기계가공학회지
    • /
    • 제21권4호
    • /
    • pp.91-99
    • /
    • 2022
  • By applying METHOD 514.8 of the US military standard MIL-STD-810H, vibration analysis of the winding core automatic feeding device was performed during vehicle transportation. The contact point between the LM guide and main support frame was weak in the vertical axis, transverse axis, and longitudinal axis during the transportation of the automatic winding core feeder vehicle, and the maximum equivalent stress was 236.31 MPa in the longitudinal axis. When random vibration was applied, the safety margin in the longitudinal direction was 0.26, indicating low safety. The safety margin was changed by increasing the damage factor to 0.1. Finally, the safety margin was improved to 3.48 to secure safety. Resonance occurred with a Q factor of 9.34 in the harmonic response to which the RMS value of the ASD data was input, and the vertical axis safety margin was derived as 0.16. When the damping factor was 0.15, the Q factor was 3.37, and resonance was avoided with a safety margin of 6.62.

자속구속형 전류제한기의 초기 사고전류 제한시점 변화 (Variance of Initial Fault Current Limiting Instant in Flux-lock Type SFCL)

  • 박충렬;임성훈;박형민;최효상;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권3호
    • /
    • pp.269-275
    • /
    • 2005
  • A flux lock-type SFCL consists of two coils which are wound in parallel each other through an iron core, and a HTSC thin film connects in series with coil 2. The operation of the flux-lock type SFCL can be divided into the subtractive polarity winding and the additive polarity winding operations according to the winding directions between coil 1, coil 2. When a fault occurs, the fault current in the HTS thin film exceeds the critical current so that resistance is generated in the HTS film, and thereby the fault current is limited by an instant rise in the impedance of the flux-lock type SFCL. We investigated he variances of initial fault current limiting instant according to the ratio of inductance of coil 1 and coil 2 in the flux-lock type SFCL. It was confirmed from experiments that the initial fault current limiting instant in the subtractive polarity and additive polarity windings were faster as the ratio of coil 2' inductance for coil 1's inductance increased. The 1st peak of fault current in case of the subtractive polarity winding was higher as the ratio of coil 2's inductance for coil 1's inductance increased. On the other hand, in case of the additive polarity winding, the 1st peak of fault current was lower.

개루프 철심을 이용한 자속구속형 초전도한류기의 전압별 전류제한 특성분석 (Fault Current limiting Characteristics of Flux-Lock type Superconducting Fault Current Limiter with Open-loop Iron Core according to the Voltage Level)

  • 남긍현;최효상;박형민;조용선;이나영;임성훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 추계학술대회 논문집 전력기술부문
    • /
    • pp.368-370
    • /
    • 2005
  • Superconducting fault current limiter (SFCL) provides the effect such as enhancement in power system reliability due to limiting fault current in a few miliseconds. The flux-lock type SFCL among various type SFCLs consists of two coils wound on the same iron core and a component using the YBCO thin film. In the SFCL, operation characteristics can be controlled by adjusting the inductances and the winding directions of the coils. In this paper, we investigated the various fault current limiting characteristics according to the voltage level. To analyze the current limiting performance, we compared operational characteristics on the subtractive polarity winding direction on in case of open-loop iron core.

  • PDF

자속구속리액터의 철심조건에 따른 특성 (Characteristics under the Iron Core Conditions of the Flux-lock Reactor)

  • 이나영;최효상;박형민;조용선;남긍현;한태희;임성훈
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2006년도 제37회 하계학술대회 논문집 B
    • /
    • pp.875-876
    • /
    • 2006
  • Superconducting fault currents(SFCLs) are expected to improve not only reliability but also stability of power systems. The analysis on current limiting operations of the flux-lock type SFCL, which consists of a flux-lock reactor wound an iron core and a YBCO thin film, was compared the open-loop with the closed-loop iron core of the subtractive polarity winding. In the SFCL, operation characteristics could be controlled by adjusting the inductances and the winding directions of the coils, then magnetic field induced in the iron core. The current limiting characteristics under the same experimental conditions were generated regardless of the iron core conditions. We confirmed that capacity of the SFCL was increased effectively by the closed-loop iron core. However, the power burden of the system could be lowered by the open-loop iron core.

  • PDF

필름코일을 이용한 슬롯리스형 BLDC 모터의 설계 (Design of slotless BLDC motor using film coil)

  • 김만중;제환영;김학원;성병호
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2001년도 추계학술대회 논문집 전기기기 및 에너지변환시스템부문
    • /
    • pp.104-106
    • /
    • 2001
  • In this paper, it is object of design of high efficiency slotless BLDC motor using film coil. Slotless BLDC motor is able to have high efficiency property and low cogging torque, due to magnetization of stator core have constant contribution by slotless core. But it is difficult to make coil winding of slotless BLDC motor. So we make amateur of slotless BLDC motor using film coil. Film coil is fabricated by drilling, electro-plating and etching of copper/insulator/copper plate. In this paper, after design of slotless BLDC motor for moving axial blower, it is fabricated by NdFeB permanent magnet type rotor and film coil.

  • PDF

사고각에 따른 자속구속형 전류제한기의 전류제한특성 (Current Limiting Characteristics of flux-lock Type High-lc Superconducting Fault Current Limiter According to fault Angles)

  • 박형민;최효상;조용선;임성훈;박충렬;한병성
    • 한국전기전자재료학회논문지
    • /
    • 제18권8호
    • /
    • pp.747-753
    • /
    • 2005
  • We Investigated the current limiting characteristics of the flux-lock type superconducting fault current limiter(SFCL) by fault angles. The flux-lock type SFCL consists of the primary and the secondary copper coils wound in parallel through the iron core and YBCO thin film. In this paper, the current limiting characteristics of the flux-lock type SFCL by fault angles in case of the subtractive and the additive polarity windings were compared and analyzed. The flux-lock type SFCL limited fault current more quickly as the fault angles increased. On the other hand, the initial power burden of the superconducting element during the fault increased as the fault angles increased. In addition, we found that the resistance of the flux-lock type SFCL in case of the subtractive polarity winding was more increased than that of the additive polarity winding. The peak current of the fault current in case of the subtractive polarity winding was larger than that of the additive polarity winding.

개루프 철심을 이용한 자속구속형 초전도한류기의 퀜치특성 (Quench Characteristics of Flux-lock type Superconducting Fault Current Limiter using Open-loop Iron Core)

  • 남긍현;최효상;박형민;조용선;이나영;임성훈;박충렬
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2005년도 추계학술대회 논문집 Vol.18
    • /
    • pp.159-160
    • /
    • 2005
  • The superconducting fault current limiter(SFCLs) provides the effect such as enhancement in the power system reliability due to limiting fault current in a few miliseconds. The Flux-lock type SFCL using the YBCO film among various type SFCLs consists of the primary and the secondary copper coils that are wound in parallel each other through the iron core. The operation can be controlled by adjusting the inductances and the winging directions of each the coil. We compared the current limiting performance on the additive and the subtractive polarity winding directions in case of an open-loop iron core. To analyze quench characteristics, we experimented various phase angle.

  • PDF

자속 구속형 고온초전도 전류제한기의 동작특성 분석 (The Analysis of Operation Characteristics of Flux-Lock Type High-Tc Superconducting Fault Currents Limiter)

  • 박충렬;임성훈;박형민;이종화;고석철;최효상;한병성;현옥배;정동철
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2004년도 하계학술대회 논문집 B
    • /
    • pp.1130-1132
    • /
    • 2004
  • In this paper, we investigated the operational characteristics of the fault current limiting in the The flux-lock type high-Tc superconducting fault current limiter. The flux-lock type high-Tc superconducting fault current limiter was consisted of primary and secondary copper coils that flux was locked on iron core and YBCO thin film. The operational characteristic of a flux-lock type SFCL dependent on winding direction of coil 1 and coil 2, and the number of turns of coil 1 and coil 2, inductances of the coils, saturation in iron core, the properties of superconducting element etc. In this cases, we investigated the fault currents limiting characteristics of the flux-lock type SFCL when winding direction of coil 1 and coil 2 was subtractive polarity winding.

  • PDF

자속구속형 초전도 전류제한기의 철심조건에 따른 특성 (Characteristics of the Flux-lock Type Superconducting Fault Current Limiter According to the Iron Core Conditions)

  • 남긍현;이나영;최효상;조금배
    • 조명전기설비학회논문지
    • /
    • 제20권7호
    • /
    • pp.38-45
    • /
    • 2006
  • 초전도전류제한기(SFCL)는 전력계통내 적용시 계통보호를 보다 향상시킬 수 있는 방안으로써 수초이내에 신속하게 사고전류를 제한한다. 이러한 SFCL중 자속구속형 전류제한기의 설계구조는 자속구속리액터인 하나의 철심에 1차측과 2차측 코일이 병렬로 결선되어 있다. 또한 전류제한소자인 YBCO박막과 2차측 코일을 직렬로 결선하여 설치장소의 조건에 따라 인덕턴스와 2차측 코일의 극성방향으로 과도전류 크기를 조절할 수 있다. 이러한 동작특성은 철심을 자속매개체로 적용되기 때문에 철심조건에 따른 성능평가실험은 필수적이다. 가극결선에서 전원전압을 200[Vrms] 인가시 피크전류는 폐루프가 30.71[A], 개루프가 32.01[A]까지 상승됨에 따라 초기과도 응답특성은 폐루프가 유리하였다. 하지만, 소자에 발생되는 전압이 폐루프가 220.14[V], 개루프가 142.73[V]까지 상승함에 따라, 폐루프 철심구조시 전류제한소자의 부담이 가중됨을 알 수 있었다. 결과적으로 자속구속형 SFCL의 전력계통내 적용 시 각각의 철심구조에 따른 다양한 운전특성을 적절히 설계시 장점을 극대화 할 수 있을 것이다.