A Convenient System for Film Dosimetry Using NIH-image Software

  • Kurooka, Masahiko;Koyama, Syuji;Obata, Yasunori;Homma, Mitsuhiko;Imai, Kuniharu;Tabushi, Katsuyoshi
    • 한국의학물리학회:학술대회논문집
    • /
    • 한국의학물리학회 2002년도 Proceedings
    • /
    • pp.260-262
    • /
    • 2002
  • An accurate measurement of dose distribution is indispensable to perform radiation therapy planning. A measurement technique using a radiographic film, which is called a film dosimetry, is widely used because it is easy to obtain a dose distribution with a good special resolution. In this study, we tried to develop an analyzing system for the film dosimetry using usual office automation equipments such as a personal computer and an image scanner. A film was sandwiched between two solid water phantom blocks (30 ${\times}$ 30 ${\times}$ 15cm). The film was exposed with Cobalt-60 ${\gamma}$-ray whose beam axis was parallel to the film surface. The density distribution on the exposed film was stored in a personal computer through an image scanner (8bits) and the film density was shown as the digital value with NIH-image software. Isodose curves were obtained from the relationship between the digital value and the absorbed dose calculated from percentage depth dose and absorbed dose at the reference point. The isodose curves were also obtained using an Isodose plotter, for reference. The measurements were carried out for 31cGy (exposure time: 120seconds) and 80cGy (exposure time: 300seconds) at the reference point. While the isodose curves obtained with our system were drawn up to 60% dose range for the case of 80cGy, the isodose curves could be drawn up to 80% dose range for the case of 31cGy. Furthermore, the isodose curves almost agreed with that obtained with the isodose plotter in low dose range. However, further improvement of our system is necessary in high dose range.

  • PDF

The Assessment of the Postural Control Ability of the Volleyball Players With Functional Ankle Instability Using Balance Master System

  • Kim, Ho-Sung;Ahn, Chang-Sik;Choi, Jong-Duk
    • 한국전문물리치료학회지
    • /
    • 제15권4호
    • /
    • pp.18-26
    • /
    • 2008
  • The present study was aimed at investigating the postural control ability of volleyball players with functional ankle instability. The subjects were 26 male volleyball players were divided into 2 groups (13 subjects with functional ankle instability and 13 subjects with ankle stability) who could evaluate Questionnaire. All the male participants were tested by a Balance Master System. This study were to measure of static balance ability, dynamic balance ability, motor function the difference between functional ankle instability group and control group. Ankle instability group and stable group in postural sway ($^{\circ}/sec$) on film surface with eye closed in modified clinical test sensory interaction on balance, and left unilateral stance with eye opened and closed were significantly different (p<.05). The ankle instability group and stable group in limit of stability were significantly different (p<.05). The ankle instability group and stable group in left/right rhythmic weight shirt were significantly different (p<.05). The ankle instability group and stable group in turn time (sec) & turn sway ($^{\circ}$) during step/quick turn and end sway ($^{\circ}/sec$) in tandem walk were significantly different (p<.05). This study showed that volleyball players with functional ankle in stability were effected postural control ability by static balance & dynamic balance ability. Further study is needed to measure various athletic with functional ankle instability for clinical application.

  • PDF

Convenient Therapy with Specially Designed Radionuclide, 166Ho Skin Patch for Skin Cancer

  • Ryu, Jei-Man;Seong, Seung-Kyoo;Kim, You-Eun;Shin, Dong-Hyuk;Jung, Yong-Ho;Shin, Byong-Chul;Park, Kyong-Bae;Lee, Jong-Du
    • 대한약학회:학술대회논문집
    • /
    • 대한약학회 2003년도 Proceedings of the Convention of the Pharmaceutical Society of Korea Vol.1
    • /
    • pp.156.1-156.1
    • /
    • 2003
  • 166Ho, a $\beta$-emitting radionuclide, was incorporated within polyurethane film for possible application for the therapy of skin cancers. The aim of this study was to investigate skin irritant after radiation with 166Ho patch in rabbits and to estimate the efficacy of this therapy for skin cancer patients. Six NZW rabbits were used for skin irritant in this study. The dorsal hair of rabbits was removed with an electric clipper and blade. (omitted)

  • PDF

호흡 동조 체적 세기조절 회전 방사선치료의 유용성 평가와 진폭모드를 이용한 환자적용 (Usefulness of Gated RapidArc Radiation Therapy Patient evaluation and applied with the Amplitude mode)

  • 김성기;임현실;김완선
    • 대한방사선치료학회지
    • /
    • 제26권1호
    • /
    • pp.29-35
    • /
    • 2014
  • 목 적 : 본 연구는 이미 상용화가 시작된 호흡 동조 체적 세기조절 회전 방사선 치료(Gated RapidArc) 이전의 자동화가 되지 않는 장비들에서 호흡 동조 방사선 치료(Gated radiation therapy)와 체적 세기조절 회전 방사선 치료(VMAT)를 동시에 시행할 수 있게 Gated RapidArc의 정확성을 분석하여 유용성을 평가하고, 진폭모드(Amplitude mode)를 이용하여 Gated RapidArc가 자동으로 되지 않는 장비에 환자를 적용하여 보고자 하였다. 대상 및 방법 : 방사선량 분포의 분석은 물 등가물질 고체 팬톰과 GafChromic 필름(EBT2 QD+, USA)을 이용하였으며, Film QA (ver. 2.2, USA) 필름 분석 프로그램을 이용하여 Gamma 인자(3%, 3 mm)를 분석하였다. 또한, 삼차원 선량 분포의 정확도를 확인하기 위해서 Matrixx(IBA Dosimery, Germany) 선량 측정 장비와 Compass(IBA Dosimetry, Germany) 선량 분석 프로그램을 이용하였다. 고체 팬톰을 이용한 호흡 동조 주기 신호는 4D 팬톰(Dynamic Thorax Phantom, CIRS, USA)과 Varian RPM(Real-Time Position Monitor) 호흡 동조 시스템을 이용하여 만들었으며, 자유호흡(free breathing)과 호흡정지(breath holding) 시에 따른 방사선량 분포를 각각에 대하여 분석 평가하였다. 환자에게 적용하기 위하여 2013년 2월부터 2013년 8월까지 간암환자 4명을 대상으로 4DCT의 영상을 얻기 위하여 충분한 호흡주기 연습후에 환자의 호흡주기에 맞게 위상모드(Phase mode)를 이용하여 환자가 고글의 호흡주기 패턴을 눈으로 보고 정확하게 따라할 수 있도록 하면서 4DCT의 영상을 획득하였다. Gated RapidArc 치료를 위하여 진폭모드(Amplitude mode)의 호흡주기를 만들어 3회 호흡을 시행한 후 40%~60%의 구간에서 5~6초 호흡을 참을 수 있도록 연습을 하고, 치료 시 40%~60%의 구간에서 환자가 숨을 참을 때 Beam On 버튼을 눌러주는 방식의 반자동으로 치료를 시행하였다. 결 과 : 비 호흡 및 호흡 동조 체적 세기조절 회전 방사선 치료기법 간의 절대선량은 전산화 치료 계획을 이용한 계산값과 1% 이내의 차이를 보였으며, 치료 기법 간의 차이 또한 1% 이내의 차이를 보였다. Gamma 인자(3%, 3 mm)는 99% 이상의 일치함을 보였으며, 각 장기별 선량 차이는 대체로 95% 이상의 일치함을 보였다. 또한 호흡 동조 체적 세기조절 회전 방사선 치료를 위하여 만든 진폭모드(Amplitude mode)의 호흡주기와 실제 환자의 호흡주기가 잘 일치하는 것을 볼 수 있었다. 결 론 : 비 호흡 동조와 호흡 동조 시 체적 세기조절 회전 방사선 치료간의 절대 선량 및 방사선량의 분포가 매우 잘 일치함을 보였다. 이는 호흡 동조 체적 세기조절 회전 방사선 치료 기법을 이용하여 호흡에 따라 움직이는 흉부나 복부의 종양 치료에 적용이 가능한 것으로 사료된다. 또한 실제 치료환자를 대상으로 고글을 통하여 진폭모드(Amplitude mode)의 호흡주기를 만들어 Gated RapidArc가 자동으로 되지 않는 장비에 치료를 적용한 결과, 5~6초정도 정지된 호흡에서 호흡 동조 체적 세기조절 회전 방사선 치료가 원활히 이루어짐을 알 수 있었다.

폐농양 환자 1례 (Clinical Study of a Lung Abscess Patient Combined with Stroke)

  • 한영주;이정은;임도희;황지호;배한호;박양춘;조철준
    • 동의생리병리학회지
    • /
    • 제19권4호
    • /
    • pp.1078-1081
    • /
    • 2005
  • Lung abscess is often ocuured by aspiration of infectious secretion in stroke patients that has symptom of dysphagia. So we studied the effects of combined eastern and western treatment in lung abscess patient combined with stroke. We performed both antibiotic therapy and herbal medication in a lung abscess patient. We compared a chest x-ray film of early stage of disease with a film of after stage of disease, also compared change of symptom-cough, sputum, flank pain, blood phlem. After dispending antibiotic therapy and herbal medication, a lung abscess patient improved symptoms and in result of chest x-ray. The above results suggest that combined eastern and western trearment can have good effects on improving symptoms of a lung abscess patient.

전자포탈영상장치(EPID)와 GafChromic EBT3 film을 이용한 다엽콜리메이터 정도관리 시 갠트리 각도 변화에 따른 엽의 위치 정확성 비교 평가 (Comparative evaluation for leaf position accuracy according to gantry angle variation in MLC quality assurance using electronic portal imaging device(EPID) and GafChromic EBT3 film)

  • 양명식;박주경;이승훈;이선영;김정수;권형철;김양수
    • 대한방사선치료학회지
    • /
    • 제29권2호
    • /
    • pp.83-91
    • /
    • 2017
  • 목 적: 본 연구에서는 EPID와 GafChromic EBT3 film을 이용하여 picket fence test를 시행하여 갠트리 각도에 따른 중력 효과로 인한 다엽콜리메이터의 엽의 위치 오차를 분석하여 정확성을 평가하고자 하였다. 대상 및 방법: 테이블에 5 cm의 고체 팬텀을 놓고 SAD를 100 cm이 되도록 설정하였다. EBT3 film을 고체 팬텀 위에 정확하게 놓이게 한 후 1.5 cm의 고체 팬텀을 놓고 picket fence test를 시행하였다. EPID는 선원 검출기간 거리 100 cm에서 EBT3 film과 같은 조건으로 측정했다. 갠트리 각도에 따른 다엽콜리메이터 이동 위치를 알아보기 위해 갠트리 각도 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$에서 각각 측정하였다. 다엽콜리메이터의 기하학적 평가를 위해 분석 프로그램을 이용하여 다엽콜리메이터의 엽의 위치 정확성을 분석하였다. 결 과: EPID의 경우 갠트리 각도 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$로 갠트리 각도를 변경했을 때 엽의 위치 오차는 각각 평균 0.18 mm, 0.31 mm, 0.20 mm, 0.26 mm였고, 오차의 최댓값은 각각 0.44 mm, 0.54 mm, 0.34 mm, 0.44 mm였다. EBT3 film은 갠트리 각도 $0^{\circ}$, $90^{\circ}$, $180^{\circ}$, $270^{\circ}$로 갠트리 각도를 변경했을 때 엽의 위치 오차는 각각 평균 0.19 mm, 0.21 mm, 0.19 mm, 0.31 mm였고, 오차의 최댓값은 각각 0.35 mm, 0.45 mm, 0.36 mm, 0.48 mm였다. 결 론: 본 연구는 갠트리 각도에 따른 다엽콜리메이터의 엽의 위치 오류를 분석해본 결과 중력효과에 의한 엽의 위치 오류를 확인하였고, EPID와 EBT3 film을 이용하여 갠트리 각도 변화에 따른 엽의 정확성을 비교한 결과 EPID을 이용한 오차 분석방법에서 EBT3 film보다 더 큰 오차가 발생했다. 따라서 다엽콜리메이터를 기반으로 하는 세기조절방사선치료의 경우 정확한 선량 조사에 대한 검증뿐만 아니라 다엽콜리메이터의 정확하고 정밀한 작동에 대한 정도관리와 분석방법에 대한 비교 및 검증이 필요할 것으로 사료된다.

  • PDF

CORVUS Planning System을 사용한 세기조절방사선치료의 정도관리에 관한 연구 (Quality Assurance of CORVUS Planning System for Intensity Modulated Radiation Therapy)

  • 김성규
    • 한국의학물리학회지:의학물리
    • /
    • 제15권1호
    • /
    • pp.9-16
    • /
    • 2004
  • 세기조절 방사선 치료는 방사선 치료의 목적인 암 조직에는 더 많은 선량을 조사하면서, 주위 정상조직과 중요 장기에는 가능한 적은 선량이 조사되도록 하는 가장 우수한 치료 방법의 하니로 알려져 있어서 이의 임상 적용이 늘어나고 있다. 세기조절 방사선 치료의 특성상, 치료 전 과정에서 고도의 정확 정밀성을 요구하고 있다. 따라서 방사선이 치료계획된 대로 정확하게 조사되는지 검증하는 정도관리 과정이 무엇보다도 중요하며 필수적이다. 따라서 세기조절방사선 치료에는 검증과정이 필수적이다. 본 연구에서는 치료 계획 장치인 Corvus system의 정도 관리를 위한 선량 검증 방법을 고안하였으며 이의 유용성을 확인하기 위하여 두경부 부위의 세기조절 방사선치료를 설계하고 이에 관한 정도 관리를 수행하였다. 아크릴 팬톰을 이용하여 필름과 전리함, TLD를 이용한 측정 및 평가를 시행하였다. 필름 측정은 90% 선량분포에서 가로 0.03 cm, 세로 0.28 cm의 차이를 보였고, 전리함 및 TLD를 이용한 측정에서는 치료 계획과 측정치와의 차이가 각각 1%, 1.2%를 보여 이 시스템을 임상에 사용할 수 있음을 확인할 수 있었다.

  • PDF

다이오드를 이용한 치료방사선 검출기의 특성에 관한 연구 (A Study on the Characteristics of Therapy Radiation Detector with Diode)

  • 이동훈;지영훈
    • 대한의용생체공학회:의공학회지
    • /
    • 제16권2호
    • /
    • pp.129-138
    • /
    • 1995
  • 최근 방사선 치료에서 가속기를 이용한 고에너지, 고선량율 X-선과 전자선을 암환자 치료에 이용하고 있다. 치료시 방사선 조사선량의 5% 증감은 방사선 치료성적의 성패를 직접적으로 간여하고 있다고 국제 방사선 규정협회는 규정하고 있다. 본 논문에서는 방사선 치료에 영향을 미치는 빔 파라메터의 변동여부를 빠르고 간편하게 검출해 낼 수 있는 장치를 범용 실리콘 다이오드를 이용하여 제작한후 그 특성에 관해 고찰해 보았다. 13개 다이오드를 X-축 및 Y-축에 각각 7개씩 배열한 후 조사영역의 빔의 대칭도, 편평도, 안정성 등을 검출하여 보았고 방사선 손상에 대한 고찰, 일정기간 후의 변화량, 에너지 의존성 및 심부량 백분률등을 기존의 측정방법인 기체전리함을 이용한방법, 필름을 이용한 방법, 반도체 소자를 이용한 방법과의 값과 비교 분석하였다.

  • PDF

6 MV 선형가속기를 사용한 유방암 치료 (A Trial of 6 MV Linear Accelerator Radiation Therapy (RT) for Breast Cancer)

  • 이귀원;박주선;김걸;윤세철
    • 대한방사선치료학회지
    • /
    • 제1권1호
    • /
    • pp.37-42
    • /
    • 1985
  • Radiation Therapy(RT) has been used in the treatment of breast cancer for over 80 years. Technically, it should include a part or all of such areas as chest wall or breast, axilla, internal mammary nodes(IM) and supraclavicular nodes (SCL). Authors tried three-field technique for the treatment of breast cancer using 6 MV linear accelerator, exclusively the department of Radiology, Kang-Nam St. Mary's Hospital, at Catholic Medical College. The field junction was checked by a phantom study and radiation doses measured by film densitometry and TLD. The 3 fields we used in this study were two isocentric opposing tangential fields encompassing the breast, chest wall and occasionally IM and one single anterior field encompassing the axilla and SCL. Using appropriate beam blocks and blouses, we were able to avoid unwanted intrinsic divergency of photon beam. Blocking also enabled us to set-up precise radiation field with ease.

  • PDF

Digital Fluoroscopy System을 이용한 견갑면에서 일어나는 견갑상완 리듬 분석 (Analysis of Scapulohumeral Rhythm in Scapular Plane by Digital Fluoroscopy System)

  • 김재헌;배성수
    • The Journal of Korean Physical Therapy
    • /
    • 제14권3호
    • /
    • pp.92-105
    • /
    • 2002
  • This research described dynamic scapulohumeral rhythm though the measurement of inter relationship between humorous and scapular movement during elevation of the arm in the scapular plane. In the previous studies static plane film X-ray has usually been used, but the limitation of such method was that it did not show the real· movement. In this study, we investigated real movement of humorous and scapular bones by Digital fluoroscopy system. 1. In resting position, humorous was taken to lie at the average $5.97^{\circ}$ in abduction, and scapular at the average $3.66^{\circ}$ in internal rotation. 2. At the maximal abduction, humorous was abducted to the average of 181.25", and scapular was rotated externally to $51.43^{\circ}$. 3. This research has shown that there is a variety of scapulohumeral rhythm from resting position to $60^{\circ}$ abduction in elevation of humorous. This case study demonstrated that the ratio n of scapulohumeral rhythm is 3.46 to 1, but there was individual difference.

  • PDF