• Title/Summary/Keyword: Filling Machine

Search Result 115, Processing Time 0.026 seconds

The Efficacy of New Hyaluronic Acid Filler (HyaFilia) (새롭게 개발된 히알루론산 필러(히아필리아)의 유용성)

  • Jang, Joon-Chul;Shin, Soo-Hye;Han, Seung-Kyu;Kim, Woo-Kyung
    • Archives of Plastic Surgery
    • /
    • v.38 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Purpose: Currently, soft tissue filler products based on hyaluronic acid are widely used. They are safe, effective, and convenient to use compared with bovine collagens. However, all commercially available hyaluronic acid based fillers in Korea are imported ones. The purpose of this study is to evaluate efficacy of a new hyaluronic acid filler (HyaFilia; CHA bio&Diostech Co., Seoul), which has been recently developed in Korea. Methods: Three kinds of soft tissue fillers, including Restylane (Q-Med, Uppsala, Sweden), HyaFilia (CHA bio & Diostech Co., Seoul), Juvederm (Allergan, CA, USA), were injected subdermally into the back of hairless mice at six sites. The 2 cephalic sites composed Restylane groups, the 2 middle sites HyaFilia groups, and the 2 caudal sites Juvederm groups. Six hairless mice were included in the study, therefore, a total of 12 injections per group were performed. After 16 weeks after injection, the nodular swellings that resulted from the injections were excised wide enough to include skin beyond the swelling points down to the panniculus carnosus layer using 8mm punches. Volumes and weights were measured using a stereoimage optical topometer system and a weighting machine. Histologic comparisons were also carried out. Results: The mean volumes of the Restylane, HyaFilia and Juvederm groups were $3698{\times}103$, $4820{\times}103$, and $1435{\times}103$ PI, respectively. The mean weights of the Restylane, HyaFilia and Juvederm groups were 36.08, 37.83, and 24.66 mg, respectively. Histologic examination between the 3 groups showed no significant difference in tissue compositions and inflammatory reactions. Conclusion: The results of this study shows that HyaFilia is superior to Restylane and Juvederm in longavity of filling effect. Therefore, HyaFilia may be an effective replacement for the imported materials including Restylane and Juvederm.

A RADIOGRAPHIC STUDY ON THE EXPERIMENTAL LESIONS OF THE MAXILLARY SINUS (상악동 실험병소에 관한 방사선학적 연구)

  • Kim Young-Il;Kim Jae-Duk
    • Journal of Korean Academy of Oral and Maxillofacial Radiology
    • /
    • v.25 no.1
    • /
    • pp.39-49
    • /
    • 1995
  • This study was performed to determine the each location of lesions in the maxillary sinus and to evaluate the relationship between the floor of the antrum and the apical regions of teeth by the comparison of the panoramic view and panoramic sinus view. For this study, experimentally with two dry skulls, jelly balls of 8mm and 15mm in diameter containing a short wire for the radiopacity similar to the cyst and clinically 5 patients having mucosal cyst in the antrum and 10 patients having periapical lesion of molar were used. The experimental cystic lesions were simulated with jelly ball being attached in turn to each wall of the antrum. The radiolucent periapical lesions of upper molars were formed by using round bur and the radiopaque periapical lesions were simulated by filling the former lesions with lead foil. Each panoramic view and each panoramic sinus view of the experimental lesions and patients were obtained by using panoramic machine and analyzed. The obtained results were as follows : 1. On the panoramic sinus view, the innominate line was approximately coincided with the most lateral portion of the antrum and the posterior wall appeared as the narrow area at the mesial side of the innominate line. The anterior wall occupied totally the mesial side of the innominate line, and the medial wall occupied the mesial half of the antrum. 2. In all cases of experimental cystic lesion attached to each wall of the antrum, the location of each lesion was able to be determined by applying Tube shift technic. 3. The palatal root and mesiobuccal root of the molar appeared as being transposed each other mesiolaterally on the panoramic and panoramic sinus views. 4. The panoramic sinus view was superior to the panoramic view in revealing the relationship between the floor of the antrum and the periapical lesion.

  • PDF

A STUDY OF THE SHEAR BOND STRENGTH OF COMPOSITE RESIN TO LIGHT-CURING GLASS IONOMER CEMENTS (광중합형 글라스아이오노머 시멘트와 복합레진과의 전단결합강도에 관한 연구)

  • Kim, Deok;Min, Byung-Soon
    • Restorative Dentistry and Endodontics
    • /
    • v.19 no.2
    • /
    • pp.447-459
    • /
    • 1994
  • The purpose of this study is to evaluate of shear bond strength of light-curing composite resin to light-curing glass ionomer cement. Composite resin and glass ionomer cement have been widely used as an esthetic filling materials in dental clinics. To achieve better clinical results, sandwich technic was developed with conpensating for disadvantages of these two materials. Especially, light-curing glass ionomer cement provided greately improved bonding strength of teeth or composite resin, and then excellent clinical results can be acquired. In this study, 6 commercial light-curing glass ionomer cements(3 commercial restorative materials : Fuji II LC, Variglass VLC, Vitremer, and 3 commercial lining materials : Fuji Lining LC, Baseline VLC, Vitrebond) were devided two groups. According to manufacturer's appointment, no surface treatment was referred to N groups. Supposing. of clinical practice, surface grinding with water spray at 320 grit sand paper, 40 seconds etching with 37% phosphoric acid, 20 seconds washing, 20 seconds air drying was referred to N groups. Totally 12 experimental groups were devided, and all 120 specimens from 10 specimens of each groups were made. After light-curing composite resin was bonded to light-curing glass ionomer cement, shear bond strength was tested by Instron universal testing machine between glass ionomer cement and composit resin. The data were analyzed statistically by Student's t-test and ANOVA. The obtained results were as follows; 1. In light-curing glass ionomer cement, restorative materials showed higher shear bond strength to composite resin than lining materials(p<0.05). 2. Variglass VLC of restorative material group and Baseline VLC of lining material group have highest shear bond strength to composite resin(p<0.001). 3. In light-curing glass ionomer cement, surface grinding and acid etching reduced shear bond strength to composite resin(p<0.001)}. 4. VGN group 1s highest shear bond strength to composite resin, VBE group is lowest shear bond strength to composite resin(p<0.001).

  • PDF

Hermeneutic Phenomenological Study on Caring Experience of Spouses of Elderly People with Dementia at Home (재가 치매노인 배우자의 돌봄 체험에 관한 해석학적 현상학 연구)

  • Jang, Hye-Young;Yi, Myungsun
    • Journal of Korean Academy of Nursing
    • /
    • v.47 no.3
    • /
    • pp.367-379
    • /
    • 2017
  • Purpose: This study aimed to understand and describe the caring experiences of spouses of elderly people with dementia. Methods: The hermeneutic phenomenological method was used and participants were 12 spouses aged 65 and over who were taking care of their husbands or wives with dementia at home. Data were collected from individual in-depth interviews on participants' actual caring experiences. Additionally, novels, movies, and memoirs on elderly couples with partner who had dementia were included as data for the analysis. The qualitative data analysis software program was used to manage and process the collected qualitative data. Data were analyzed using hermeneutic phenomenological analysis based on four fundamental existentials including lived body, lived space, lived time, and lived others. Results: Five essential themes emerged from the analysis: 1) body moving like an old machine, 2) swamp of despair filling with hope, 3) sweet time after bitterness, 4) disappointed elderly couple in the empty nest, and 5) unappreciation vs. empathetic feelings. These essential themes were comprehensively summarized as "the road leading to the maturation of life with dedication and hope while bearing the weight of caring based on the couple's relationship." Conclusion: The findings indicate that the nature of the caring experience of spouses of elderly individuals with dementia is filled with many dynamic and paradoxical dimensions. Thus, results of the study would help with developing interventions tailored specifically for elderly spouse caregivers to support their role adaptation and ultimately improving their quality of life.

Data BILuring Method for Solving Sparseness Problem in Collaborative Filtering (협동적 여과에서의 희소성 문제 해결을 위한 데이타 블러링 기법)

  • Kim, Hyung-Il;Kim, Jun-Tae
    • Journal of KIISE:Software and Applications
    • /
    • v.32 no.6
    • /
    • pp.542-553
    • /
    • 2005
  • Recommendation systems analyze user preferences and recommend items to a user by predicting the user's preference for those items. Among various kinds of recommendation methods, collaborative filtering(CF) has been widely used and successfully applied to practical applications. However, collaborative filtering has two inherent problems: data sparseness and the cold-start problems. If there are few known preferences for a user, it is difficult to find many similar users, and therefore the performance of recommendation is degraded. This problem is more serious when a new user is first using the system. In this paper we propose a method of integrating additional feature information of users and items into CF to overcome the difficulties caused by sparseness and improve the accuracy of recommendation. In our method, we first fill in unknown preference values by using the probability distribution of feature values, then generate the top-N recommendations by applying collaborative filtering on the modified data. We call this method of filling unknown preference values as data blurring. Several experimental results that show the effectiveness of the proposed method are also presented.

Injection Molding Analysis of Map Pocket with a Speaker Grill Using Shell Element (박막 요소를 이용한 스피커 그릴 일체형 맵 포켓의 사출 성형 해석)

  • Kim, Hong-Seok;Jo, Myeong-Sang;Son, Jung-Sik;Seo, Tae-Su;Kim, Tae-Ung
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.25 no.8
    • /
    • pp.1294-1301
    • /
    • 2001
  • In order to reduce the time and cost for assembly, automobile speaker grills have been injection molded with door trims or map pockets in one piece recently. However, several defects such as short shots or air traps can easily occur due to the decreased fluidity of the melting polymer according to the excessive heat transfer to the mold. Therefore, it is necessary to optimize the resin feed system and predict possible defects by CAE analysis. However it is not possible to obtain exact analysis results for the speaker grill by using general shell elements since the heat transfer in the thickness direction which is the dominant factor of the filling stage can not be considered. Therefore, there have been several efforts to simulate the injection molding nature of the speaker grill by using shell elements with an effective thickness which is smaller than the actual thickness of the part. Two empirical values have been recommended for the effective thickness in real practice. One is 50∼70% of the thickness of the speaker grill and another is the gap distance between the adjacent holes. In this paper, CAE analyses of a map pocket with a speaker grill were conducted using shell elements with both of these recommended effective thicknesses, and the predicted flow fronts were compared with the findings from injection molding experiments. The commercial code MOLDFLOW was used for injection molding analysis and an 850 ton injection molding machine was used for experiments.

Suggestion of Model Change Work Improvement by REBA and Therblig

  • Lee, Sung-Koon;Park, Peom
    • Journal of the Ergonomics Society of Korea
    • /
    • v.30 no.6
    • /
    • pp.757-764
    • /
    • 2011
  • Objective: The aim of this study was to provide a method to improve the compliance and reduce the time by reducing the workload during the model change work. Background: The enterprises are constructing the small quantity batch production system by increasing the number of model change and reducing model-changing. However, the compliance is low because the work is strenuous and high skills are needed, so the system management is facing with many difficulties. Method: After classifying the model change work according to the purposes(preparation, change and adjustment) with the target of mascara filling machine, element tasks time were measured and the motion analysis(therblig symbol) and REBA analysis were performed. The study incorporated 3 independent variables as the number of motion, REBA score and the element time. The dependent variable is the type of element work as preparation, change and adjustment. The statistical test was performed by one-way ANOVA(${\alpha}$ < 0.05). Results: For the preparation, the number of motions appeared in the order of Use(U), Transport Loaded(TL), and Position(P). The order appeared in change is Use(U), Release Load(RL), and Grasp (G). The adjustment appeared in the order of Position(P) and Use(U). The results of average motion time as the element work times divided by the number of motion appeared in the order of adjustment(1.85sec/motion), preparation(1.11sec/motion), and change(0.62sec/motion). The results of REBA showed that the average risk level of change and adjustment were medium, but 53.1% of change and 42.9% of adjustment were evaluated as high. Conclusion: Reducing the avoidance and improving the compliance of work could be expected if the job autonomy were improved by improving the working postures with high risk level. Application: It is expected to solve the problem of reducing the time of model change work in the small quantity batch production system. The future work is to carry out the improvement directions found in the results and compare the results after improvement.

A STUDY ON THE TENSILE BOND STRENGTH OF COMPOSITE RESIN INLAYS ACCORDING TO THEIR INTERNAL SURFACE TREATMENT AND TYPES OF LUTING CEMENT (복합레진 인레이의 내면처리와 합착용 시멘트의 종류에 따른 인장접합강도에 관한 연구)

  • Kim, Jin-Cheol;Cho, Young-Gon;Hwang, Ho-Keel
    • Restorative Dentistry and Endodontics
    • /
    • v.18 no.1
    • /
    • pp.103-113
    • /
    • 1993
  • The purpose of this study was to evaluate the tensile bond strength of composite resin inlays according to the their internal surface treatment and types of luting cement and compared them with the conventional direct resin filling thchnique. Class II cavities were prepared in 50 extracted human molar teeth, and then equally divided into five groups. Group 1 : Cavities of control group were directly filled with P-50. Group 2 : Cavities of resin inlay group were luted with resin cement. Group 3 : Cavities of resin inlay group were luted with luting G-I cement. Group 4 : Cavities of resin inlay group were luted with resin cement after sandblasting. Group 5 : Cavities of resin inlay group were luted with luting G-I cement after sandblasting. All specimens were polished with same method and stored in normal saline for 24 hours before testing. An Universal Testing machine(Model No. AGS-100A, Shimadzu, Japan) was used to apply tensile loads in the vertical direction, and the force required for separation was recorded with a cross-head speed of 5mm/min and 100kg in full scale. The results were as follows : 1. The mean tensile bond strength was lowest in group luted with luting G-I cement, with measurements of $14.45{\pm}0.78(kg/cm^2)$ and highest in group luted with resin cement after sandblasting, with measurements of $49.6{\pm}2.74(kg/cm^2)$. 2. The tensile bond strength was greater in resin inlay groups luted with resin cement than in control group and resin inlay groups luted with luting G-I cement(P<0.05). 3. The tensile bond strength was lower in resin inlay groups luted with luting G-I cement than in control group(P<0.05). 4. The tensile bond strength was greater in resin inlay groups luted with resin cement or luting G-I cement after sandblasting than without that(P<0.05).

  • PDF

Effect of ultrasonic tip designs on intraradicular post removal

  • Aguiar, Anny Carine Barros;de Meireles, Daniely Amorim;Marques, Andre Augusto Franco;Sponchiado, Emilio Carlos Junior;Garrido, Angela Delfina Bitencourt;Garcia, Lucas Da Fonseca Roberti
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.4
    • /
    • pp.265-269
    • /
    • 2014
  • Objectives: To evaluate the effect of different ultrasonic tip designs on intraradicular post removal. Materials and Methods: The crowns of forty human canine teeth were removed, and after biomechanical preparation and filling, the roots were embedded in acrylic resin blocks. The post spaces were made, and root canal molding was performed with self-cured acrylic resin. After casting (Cu-Al), the posts were cemented with zinc phosphate cement. The specimens were randomly separated into 4 groups (n = 10), as follows: G1 - no ultrasonic vibration (control); G2 - ultrasonic vibration using an elongated cylindrical-shaped and active rounded tip; G3 - ultrasonic vibration with a flattened convex and linear active tip; G4 - ultrasonic vibration with active semicircular tapered tip. Ultrasonic vibration was applied for 15 seconds on each post surface and tensile test was performed in a Universal Testing Machine (Instron 4444 - 1 mm/min). Results: G4 presented the highest mean values, however, with no statistically significant difference in comparison to G3 (p > 0.05). G2 presented the lowest mean values with statistically significant difference to G3 and G4 (p < 0.05). Conclusions: Ultrasonic vibration with elongated cylindrical-shaped and active rounded tip was most effective in reducing force required for intraradicular post removal.

Bulge Characteristics of 1,000 mL Carton Pak according to the Different Storage Conditions (저장유통 조건에 따른 1,000 mL 카톤팩의 벌지현상)

  • 박종대;정관섭
    • Food Science and Preservation
    • /
    • v.10 no.3
    • /
    • pp.293-296
    • /
    • 2003
  • This study was carried out to obtain physical characteristics of paper board and to measure bulge of 1,000 mL carton pak by different storage conditions. Water holding capacity of paper boards were mean of 5.6~7.0%, stiffness of machine direction(MD) was 243.3~266.7 g/cm and cross direction(CD) was 99.2~109.2 g/cm, respectively. The weight of 1,000 mL carton pak were in the range of 29.17~31.26 g. The bulge of carton paks were 6.33~6.93 mm after 7 days at 6$^{\circ}C$ storage, 7.26~8.56 mm after 7 days at 10$^{\circ}C$ and was 8.66 mm after 7 days at 10$^{\circ}C$ treated with 1 hour heat shock per day, respectively. According to this result, the bulge length of 1,000 mL carton pak was showed increased pattern upon increasing the storage temperature and the order was 6$^{\circ}C$ < l0$^{\circ}C$ < 10$^{\circ}C$+ heat shock. To prevent bulge occurence, it was thought to control storage temperature and humidity of paper board or carton pak and to minimize their shock on cold chain system after filling process.