• Title/Summary/Keyword: Files

Search Result 2,036, Processing Time 0.027 seconds

EFFECT OF VARIOUS CANAL PREPARATION TECHNIQUES USING ROTARY NICKEL-TITANIUM FILES ON THE MAINTENANCE OF CANAL CURVATURE (수종의 엔진구동형 Nickel-Titanium file을 이용한 근관형성 방법이 근관만곡도 유지능력에 미치는 영향)

  • Lee, Cheol-Hwan;Cho, Kyung-Mo;Hong, Chan-Ui
    • Restorative Dentistry and Endodontics
    • /
    • v.28 no.1
    • /
    • pp.41-49
    • /
    • 2003
  • There are increasing usage of Nickel-Titanium rotary files in modern clinical endodontic treatment because it is effective and faster than hand filing due to reduced step. This study was conducted to evaluate the effect of canal preparations using 3 different rotary Nickel-Titanium files that has different cross sectional shape and taper on the maintenance of canal curvature. Simulated resin block were instrumented with Profile(Dentsply, USA), GT rotary files(Dentsply, USA), Hero 642(Micro-Mega France), and Pro-Taper(Dentsply, USA). The image of Pre-instrumentation and Post-instrumentation were acquired using digital camera and overspreaded in the computer. Then the total differences of canal diameter, deviation at the outer portion of curvature, deviation at the inner portion of curvature, movement of center of the canal and the centering ratio at the pre-determined level from the apex were measured. Results were statistically analyzed by means of ANOVA, followed by Scheffe test at a significance level of 0.05. The results were as follows; 1. Deviation at the outer portion of curvature, deviation at the inner portion of curvature were showed largest in Pro-Taper so also did in the total differences of canal diameter(p<0.05). 2. All the groups showed movements of center Profile combined with GT rotary files and Hero 642 has no difference but Pro-Taper showed the most deviation(p<0.05). 3. At the 1, 2, 3mm level from the apex movements of center directed toward the outer portion of curvature, but in 4, 5 mm level directed toward the inner portion of curvature(p<0.05). As a results of this study, it could be concluded that combined use of other Nickel-Titanium rotary files is strongly recommended when use Pro-Taper file because it could be remove too much canal structure and also made more deviation of canal curvature than others.

A comparison of dimensional standard of several nickel-titanium rotary files

  • Kim, Ki-Won;Cho, Kyung-Mo;Park, Se-Hee;Choi, Ki-Yeol;Karabucak, Bekir;Kim, Jin-Woo
    • Restorative Dentistry and Endodontics
    • /
    • v.39 no.1
    • /
    • pp.7-11
    • /
    • 2014
  • Objectives: The aim of this study was to compare the dimensional standard of several nickel-titanium (Ni-Ti) rotary files and verify the size conformity. Materials and Methods: ProFile (Dentsply Maillefer), RaCe (FKG Dentaire), and TF file (SybronEndo) #25 with a 0.04 and 0.06 taper were investigated, with 10 in each group for a total of 60 files. Digital images of Ni-Ti files were captured under light microscope (SZX16, Olympus) at $32{\times}$. Taper and diameter at $D_1$ to $D_{16}$ of each files were calculated digitally with AnalySIS TS Materials (OLYMPUS Soft Imaging Solutions). Differences in taper, the diameter of each level ($D_1$ to $D_{16}$) at 1 mm interval from (ANSI/ADA) specification No. 101 were statistically analyzed using one-way ANOVA and Scheffe's post-hoc test at 95% confidence level. Results: TF was the only group not conform to the nominal taper in both tapers (p < 0.05). All groups except 0.06 taper ProFile showed significant difference from the nominal diameter (p < 0.05). Conclusions: Actual size of Ni-Ti file, especially TF, was different from the manufacturer's statements.

A Method of Recovery for Damaged ZIP Files (손상된 ZIP 파일 복구 기법)

  • Jung, Byungjoon;Han, Jaehyeok;Lee, Sang-jin
    • Journal of the Korea Institute of Information Security & Cryptology
    • /
    • v.27 no.5
    • /
    • pp.1107-1115
    • /
    • 2017
  • The most commonly used PKZIP format is a ZIP file, as well as a file format used in MS Office files and application files for Android smartphones. PKZIP format files, which are widely used in various areas, require structural analysis from the viewpoint of digital forensics and should be able to recover when files are damaged. However, previous studies have focused only on recovering data or extracting meaningful data using the Deflate compression algorithm used in ZIP files. Although most of the data resides in compressed data in the ZIP file, there is also forensically meaningful data in the rest of the ZIP file, so you need to restore it to a normal ZIP file format. Therefore, this paper presents a technique to recover a damaged ZIP file to a normal ZIP file when given.

Effect of surface treatment on the mechanical properties of nickel-titanium files with a similar cross-section

  • Kwak, Sang Won;Lee, Joo Yeong;Goo, Hye-Jin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.42 no.3
    • /
    • pp.216-223
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical properties of various nickel-titanium (NiTi) files with similar tapers and cross-sectional areas depending on whether they were surface-treated. Materials and Methods: Three NiTi file systems with a similar convex triangular cross-section and the same ISO #25 tip size were selected for this study: G6 (G6), ProTaper Universal (PTU), and Dia-PT (DPT). To test torsional resistance, 5 mm of the straightened file's tip was fixed between polycarbonate blocks (n = 15/group) and continuous clockwise rotation until fracture was conducted using a customized device. To evaluate cyclic fatigue resistance, files were rotated in an artificial curved canal until fracture in a dynamic mode (n = 15/group). The torsional data were analyzed using 1-way analysis of variance and the Tukey post-hoc comparison test, while the cyclic fatigue data were analyzed using the Mann-Whitney U test at a significance level of 95%. Results: PTU showed significantly greater toughness, followed by DPT and G6 (p < 0.05). G6 showed the lowest resistance in ultimate torsional strength, while it showed a higher fracture angle than the other files (p < 0.05). In the cyclic fatigue test, DPT showed a significantly higher number of cycles to failure than PTU or G6 (p < 0.05). Conclusions: Within the limitations of this study, it can be concluded that the torsional resistance of NiTi files was affected by the cross-sectional area, while the cyclic fatigue resistance of NiTi files was influenced by the surface treatment.

A Technique to Detect Change-Coupled Files Using the Similarity of Change Types and Commit Time (변경 유형의 유사도 및 커밋 시간을 이용한 파일 변경 결합도)

  • Kim, Jung Il;Lee, Eun Joo
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.3 no.2
    • /
    • pp.65-72
    • /
    • 2014
  • Change coupling is a measure to show how strongly change-related two entities are. When two source files have been frequently changed together, they are regarded as change-coupled files and they will probably be changed together in the near future. In the previous studies, the change coupling between two files is defined with the number of common changed time, that is, common commit time of the files. However, the frequency-based technique has limitations because of 'tangled changes', which frequently happens in the development environments with version control systems. The tangled change means that several code hunks have been changed at the same time, though they have no relation with each other. In this paper, the change types of the code hunks are also used to define change coupling, in addition to the common commit time of target files. First, the frequency vector based on change types are defined with the extracted change types, and then, the similarity of change patterns are calculated using the cosine similarity measure. We conducted experiments on open source project Eclipse JDT and CDT for case studies. The result shows that the applicability of the proposed method, compared to the previous studies.

Optical Character Recognition based Security Document Image File Management System (광학문자인식 기반 보안문서 이미지 파일 관리 시스템)

  • Jeong, Pil-Seong;Cho, Yang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.10 no.3
    • /
    • pp.7-14
    • /
    • 2019
  • With the development of information and communication technology, we have been able to access and manage documents containing corporate information anytime and anywhere using smart devices. As the work environment changes to smart work, the scope of information distribution is expanded, and more efforts are needed to manage security. This paper proposes a file sharing system that enables users who have smart devices to manage and share files through mutual cooperation. Proposed file sharing system, the user can add a partner to share files with each other when uploading files kept by spliting the part of the file and the other uses an algorithm to store on the server. After converting the file to be uploaded to base64, it splits it into encrypted files among users, and then transmits it to the server when it wants to share. It is easy to manage and control files using dedicated application to view files and has high security. Using the system developed with proposed algorithm, it is possible to build a system with high efficiency even for SMEs(small and medium-sized enterprises) that can not pay much money for security.

File Sharing Algorithm based Mutual Cooperation using Smart Device (스마트 기기를 이용한 상호 협력 기반 파일 공유 시스템)

  • Jeong, Pil-Seong;Cho, Yang-Hyun
    • Journal of the Korea Convergence Society
    • /
    • v.9 no.12
    • /
    • pp.53-60
    • /
    • 2018
  • With the development of information and communication technology, we have been able to access and manage documents containing corporate information anytime and anywhere using smart devices. As the work environment changes to smart work, the scope of information distribution is expanded, and more efforts are needed to manage security. This paper proposes a file sharing system that enables users who have smart devices to manage and share files through mutual cooperation. Proposed file sharing system, the user can add a partner to share files with each other when uploading files kept by spliting the part of the file and the other uses an algorithm to store on the server. After converting the file to be uploaded to base64, it splits it into encrypted files among users, and then transmits it to the server when it wants to share. It is easy to manage and control files using dedicated application to view files and has high security. Using the system developed with proposed algorithm, it is possible to build a system with high efficiency even for SMEs(small and medium-sized enterprises) that can not pay much money for security.

Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study

  • Pawar, Ajinkya M;Thakur, Bhagyashree;Kfir, Anda;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • v.44 no.3
    • /
    • pp.31.1-31.9
    • /
    • 2019
  • Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. "No defect" was defined as root dentin that presented with no visible microcracks or fractures. "Defect" was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.

Hash Based Equality Analysis of Video Files with Steganography of Identifier Information

  • Lee, Wan Yeon;Choi, Yun-Seok
    • Journal of the Korea Society of Computer and Information
    • /
    • v.27 no.7
    • /
    • pp.17-25
    • /
    • 2022
  • Hash functions are widely used for fast equality analysis of video files because of their fixed small output sizes regardless of their input sizes. However, the hash function has the possibility of a hash collision in which different inputs derive the same output value, so there is a problem that different video files may be mistaken for the same file. In this paper, we propose an equality analysis scheme in which different video files always derive different output values using identifier information and double hash. The scheme first extracts the identifier information of an original video file, and attaches it into the end of the original file with a steganography method. Next the scheme calculates two hash output values of the original file and the extended file with attached identifier information. Finally the scheme utilizes the identifier information, the hash output value of the original file, and the hash output value of the extended file for the equality analysis of video files. For evaluation, we implement the proposed scheme into a practical software tool and show that the proposed scheme performs well the equality analysis of video files without hash collision problem and increases the resistance against the malicious hash collision attack.

A Study on analysis tools in the SWF file URL (SWF 파일의 URL정보 분석도구)

  • Jang, Dong-Hwan;Song, Yu-Jin;Lee, Jae-Yong
    • Journal of Korea Society of Industrial Information Systems
    • /
    • v.15 no.5
    • /
    • pp.105-111
    • /
    • 2010
  • SWF(Shock Wave Flash) file is a format file for vector graphics produced by Adobe. It is widely used for a variety of contents such as advertising at websites, widgets, games, education, and videos and it contains various types of data such as sound sources, script, API and images. Many SWF files contain URL information on action script for communication in the network and they can be used as important research data as well as PC users' Web Browser history in terms of forensic investigation. And a decompiler for analyzing SWF files exists by which SWF files can be analysed and URL information can be verified. However, it takes a long time to verify the URL information on action scripts of multiple SWF files by the decompiler. In this paper, analysis of URL information on action scripts and extraction of URL information from multiple SWF files by designing analysis tools for URL information in SWF files is studied.