• 제목/요약/키워드: File fracture

검색결과 47건 처리시간 0.02초

치과용 Ni-Ti파일의 표면특성에 미치는 ta-C코팅효과 (Effects of ta-C Coatings on Surface Characteristics of Dental Ni-Ti Files)

  • 박순균;최한철
    • Corrosion Science and Technology
    • /
    • 제22권5호
    • /
    • pp.368-376
    • /
    • 2023
  • Dental Ni-Ti files must ensure stability and resistance to fatigue fracture. DLC and ta-C were coated to remove defects on the surface and ensure stability, and the surface characteristics were investigated. When coated with DLC, it was black, and in case of ta-C coating, it was blue-black. Scratches, which are defects caused by mechanical processing, were formed on the surface of the un-coated Ni-Ti file from the end of the file along the direction of processing, with the Pro-file appearing in the vertical direction and the K-file appearing in the file direction. Scratches were reduced on the coated surface, and the surface roughness was greatly reduced after coating compared to before coating. The un-coated Ni-Ti file had the lowest hardness, the DLC-coated file had the highest hardness, and ta-C showed relatively high hardness. The elastic modulus of the DLC coating film was high, and the ta-C elastic modulus was low. The adhesion of the DLC coating film tended to be higher than that of ta-C, and the wear loss amount of DLC coating of taC was lower. The corrosion potential of the ta-C coating increased significantly, and the corrosion current density decreased.

반복 굽힘 스트레스 하에서 전동식 니켈-티타늄 파일의 단면적의 크기가 피로파절에 미치는 영향 : 파절역학 분석 (EFFECT OF CROSS-SECTIONAL AREA OF 6 NICKEL-TITANIUM ROTARY INSTRUMENTS ON THE FATIGUE FRACTURE UNDER CYCLIC FLEXURAL STRESS: A FRACTOGRAPHIC ANALYSIS)

  • 황수연;오소람;이윤;임상민;금기연
    • Restorative Dentistry and Endodontics
    • /
    • 제34권5호
    • /
    • pp.424-429
    • /
    • 2009
  • 본 연구의 목적은 니켈 티타늄 전동파일의 피로 파절에 파일의 단면 형태가 미치는 영향을 평가하고자 하였다. 6 종의 ProFile (Dentsply), Mtwo (VDW), K3 (SybronEndo), Heroshaper (MicroMega), NRT (Mani), Alpha system (KOMET) 니켈-티타늄 전동 파일(ISO 30 size/.04 taper)을 각 10개씩 실험군으로 배정하고 실험을 진행하였다. 니켈 티타늄 전동파일에 반복적인 장력과 압축력을 재현시킬 수 있는 피로파절 실험기(Denbotix)와 연결된 토크 조절 전동모터(Aseptico)에 각 군의 파일을 연결하여 300rpm 속도로 만곡도가 60도이고 5mm의 반경을 가진 인공 금속 근관 내를 6 mm pecking depth로 작동시켰다. 각 파일의 파절시간을 측정하고 통계 분석하여 유의성을 분석하였으며, 각 군의 파절된 모든 파일의 파절면을 주사전자현미경을 이용한 fractographic analysis를 통해 파절 역학을 규명하였다. 또한 각 군에서 3개의 사용하지 않은 새 파일을 clear resin에 매몰하고tip에서부터 3mm 지점을 횡절단하여 Image-Pro Plus (Imagej 1.34n, NIH) 소프트웨어로 절단면의 단면적을 측정하고 단면적의 크기와 피로 파절과의 상관성도 평가하였다. 실험 결과 NRT와 ProFile이 다른 실험군에 비해서 유의성 있게 높은 피로 파절 저항성을 보였다(P < .05). 또한 파일의 단면적은 피로파절 저항성과 통계학적인 유의성은 보이지 않았다. Fractographic analysis 결과 모든 시편에서 파절면은 ductile fracture와 brittle fracture가 혼재된 양상으로 나타났다. 결론적으로 니켈 티타늄 전동 파일의 단면적의 크기는 피로파절 저항과는 상관성이 적었다.

Effect of surface treatment on the mechanical properties of nickel-titanium files with a similar cross-section

  • Kwak, Sang Won;Lee, Joo Yeong;Goo, Hye-Jin;Kim, Hyeon-Cheol
    • Restorative Dentistry and Endodontics
    • /
    • 제42권3호
    • /
    • pp.216-223
    • /
    • 2017
  • Objectives: The aim of this study was to compare the mechanical properties of various nickel-titanium (NiTi) files with similar tapers and cross-sectional areas depending on whether they were surface-treated. Materials and Methods: Three NiTi file systems with a similar convex triangular cross-section and the same ISO #25 tip size were selected for this study: G6 (G6), ProTaper Universal (PTU), and Dia-PT (DPT). To test torsional resistance, 5 mm of the straightened file's tip was fixed between polycarbonate blocks (n = 15/group) and continuous clockwise rotation until fracture was conducted using a customized device. To evaluate cyclic fatigue resistance, files were rotated in an artificial curved canal until fracture in a dynamic mode (n = 15/group). The torsional data were analyzed using 1-way analysis of variance and the Tukey post-hoc comparison test, while the cyclic fatigue data were analyzed using the Mann-Whitney U test at a significance level of 95%. Results: PTU showed significantly greater toughness, followed by DPT and G6 (p < 0.05). G6 showed the lowest resistance in ultimate torsional strength, while it showed a higher fracture angle than the other files (p < 0.05). In the cyclic fatigue test, DPT showed a significantly higher number of cycles to failure than PTU or G6 (p < 0.05). Conclusions: Within the limitations of this study, it can be concluded that the torsional resistance of NiTi files was affected by the cross-sectional area, while the cyclic fatigue resistance of NiTi files was influenced by the surface treatment.

고무의 피로수명 평가를 위한 찢김에너지 정식화 (Formulation of Tearing Energy for Fatigue Life Evaluation of Rubber Material)

  • 김헌영;김호
    • 대한기계학회논문집A
    • /
    • 제29권8호
    • /
    • pp.1132-1138
    • /
    • 2005
  • Fatigue life of metal material can be predicted by the use of fracture theory and experimental database. Although prediction of fatigue life of rubber material uses the same way as metal, there are many reasons to make it almost impossible. One of the reasons is that there is not currently used fracture criteria for rubber material beacuse of non-standardization, various way of composition process of rubber and so on. Tearing energy is one of the fracture criteria which can be applied to a rubber. Even if tearing energy relaxes the restriction of rubber composition, it is also not currently used because of complication to apply in. Research material about failure process of rubber and tearing energy was reviewed to define the process of fatigue failure and the applicability of tearing energy in estimation of fatigue life for rubber. Also, 1file element formulation of tearing energy which can be used in FE analysis was developed.

보급형 3D 프린터로 제작한 쇄골 골절 모델을 이용한 정형외과 수술에 대한 유용성과 활용가능성 평가 (Evaluation of Usefulness and Availability for Orthopedic Surgery using Clavicle Fracture Model Manufactured by Desktop 3D Printer)

  • 오왕균
    • 대한방사선기술학회지:방사선기술과학
    • /
    • 제37권3호
    • /
    • pp.203-209
    • /
    • 2014
  • 쇄골 CT 영상을 이용하여 보급형 3D 프린터로 제작된 모델로 사전 수술계획을 실시하여 수술효율에 대한 유용성과 임상적 활용가능성을 평가하였다. CT 영상을 Open Source DICOM Viewer Osirix에서 STL 파일로 변환하여 FDM 와이어 척층가공방식의 보급형 3D 프린터로 환자 맞춤형 쇄골 골절 모델을 제작하였다. 또한, 인체의 좌우 대칭 특성을 이용하여 골절되지 않은 반대편 쇄골의 STL 파일을 Mirror 기법으로 손상되기 전 원형의 모델을 복원, 제작하였다. 모델은 골절의 위치와 크기, 정도가 동일하게 출력되었다. 영상의학과에서 적은 비용과 시간으로 직접 제작한 쇄골 모델을 활용하면 수술시 2차 손상을 줄이고, 최소 침습적 피하금속판 골유합술(MIPO)로 수술효율을 높일 수 있어 임상적으로 유용할 것으로 생각된다.

니켈티타늄 전동 파일의 기계적 특성 비교: Aurum Blue vs. Aurum Pro (Comparison of mechanical properties of nickel-titanium rotary files: Aurum Blue vs. Aurum Pro)

  • 곽상원;하정홍;안상미;김현철
    • 대한치과의사협회지
    • /
    • 제57권11호
    • /
    • pp.672-678
    • /
    • 2019
  • AIM: The purpose of this study was to evaluate and compare the torsional fracture resistances, cyclic fatigue resistance, and bending stiffness of two nickel-titanium (NiTi) rotary instruments made of different heat-treated alloy: Aurum Blue (heat-treated) and Aurum Pro (conventional). Methods: Forty-five Aurum Blue and Aurum Pro NiTi files were selected for the three mechanical tests (n=15). For the torsional resistance test, 3 mm file tip was fixed and the shaft was driven clockwise at 2 rpm until fracture occurred by using a customized device. Cyclic fatigue resistance was evaluated by rotating instruments in artificial canal with dynamic mode. Bending stiffness was tested by observation of the bending moment on attaining a 45° bend. The results were analyzed by student-t tests at a significance level of 95%. The fractured surface of each groups were examined under a scanning electron microscope (SEM). Results: Aurum Blue showed significantly higher toughness, ultimate strength, distortion angle, and number of cycles to failure than those of Aurum Pro (p < 0.05). However, Aurum Blue and Aurum Pro did not differ significantly in terms of bending stiffness. SEM showed typical topographic appearances of the cyclic fatigue and torsional fracture. Conclusions: Under the limitations of this study, heat-treated instruments showed higher flexibility and fracture resistances than conventional NiTi instruments.

  • PDF

ProFile, ProTaperTM K-Flexofile 근관 성형시 근관의 만곡도에 따른 근관 형태 변화 비교연구 (A COMPARATIVE STUDY ON THE CANAL CONFIGURATION AFTER SHAPING BY PROFILE, PROTAPERTM AND K-FLEXOFILE IN SIMULATED CANALS WITH DIFFERENT ANGLES OF CURVATURE)

  • 이보금;김동준;황윤찬;황인남;오원만
    • Restorative Dentistry and Endodontics
    • /
    • 제30권4호
    • /
    • pp.294-302
    • /
    • 2005
  • 본 연구는 ProFile, ProTaper 및 K-Flexofile로 근관 성형시 근관의 만곡도에 따라 근관의 형태가 어떻게 변화하는지를 비교 분석하고자 시행되었다. ISO #15 finger spreader를 15도, 30도 및 45도로 만곡시키고 에폭시 레진으로 각각도의 근관을 갖는 30개의 근관 모형을 제작하였다. 근관의 길이는 18mm로 하였고 근관의 만곡은 근관의 입구로부터 10mm 부위에서 시작하도록 제작하였다. 근관 성형에는 엔진 구동형 니켈-타이타늄 파일인 ProFile과 ProTaper, 수동형 stainless steel 파일인 K-Flexofile을 사용하였다. ProFile과 ProTaper는 제조자의 지시에 따라 크라운다운법으로 근관 성형하였고, K-Flexofile은 스텝백법으로 근관 성형하였다. 근첨부 성형은 #25파일 크기까지 시행하였다. 근관 성형 전 후 이미지를 스캐너를 이용하여 얻고 Photoshop 7.0프로그램을 이용하여 중첩하였다. 이미지 분석 프로그램을 이용하여 치근단 쪽에서부터 1, 2, 3, 4, 5, 6, 7, 8, 9및 10mm부위의 내 외측 폭경 변화와 총폭경 및 근관의 중심축에 대한 근관 변위을 측정하였다. 각 부위에서 내 외측 폭경과 총폭경 및 근관 변위의 유의성 검정을 위해 one-way ANOVA분석을 시행하였으며 각 기구간의 유의성 검정은 Scheffe's test로 사후 분석하였다. 또한 기구의 변형과 파절 여부를 평가한 결과 엔진 구동형 니켈-타이타늄 파일인 ProFile과 ProTaper를 사용하여 근관성형시 수동형 스테인레스 스틸 파일인 K-Flexofile에 비해 근관의 변위를 적게 유발하고 특히 ProFile이 근관 성형시 바람직한 기구임을 시사하였다.

만곡 근관에서 삼각 혹은 장방형 단면 구조의 니켈-티타늄 파일 응력 분포에 관한 3차원 유한요소 연구 (STRESS DISTRIBUTION FOR NITI FILES OF TRIANGULAR BASED AND RECTANGULAR BASED CROSS-SECTIONS USING 3-DIMENSIONAL FINITE ELEMENT ANALYSIS)

  • 김현주;이찬주;김병민;박정길;허복;김현철
    • Restorative Dentistry and Endodontics
    • /
    • 제34권1호
    • /
    • pp.1-7
    • /
    • 2009
  • 이 연구의 목적은 3차원 유한요소 모형 분석을 이용하여 삼각 대칭형과 5형태의 단면 및 변형된 사각 형태인 장방형 단면으로 분류되는 네 종류의 니켈티타늄 파일이 만곡 근관 적용 시의 응력 분포를 비교하는 것이다. 삼각 대칭형 단면 구조의 ProFile #30 / .06과 Heroshaper #30 / .06, 장방형 단면구조의 Mtwo #30 / .05와 NRT #30/ .06 파일을 마이크로컴퓨터 단층촬영을 하고 reverse engineering을 통하여 파일의 구조를 얻고 삼차원 유한요소모형을 제작하였다. 모형 근관 내에서 파일이 근관장끝까지 진입하여 회전할 때 발생하는von Mises 응력 분포 및 파일의 제거후의 잔류 음력의 분포양상을 ABAQUS 프로그램을 이용하여 비교하였다. 근관 내 회전 시에 발생하는 응력을 관찰하였을 때 NRT 파일에서 가장 큰 응력을 나타냈으며, 각 파일에서의 최고 응력과 최저 응력을 비교하였을 때 Mtwo파일에서 가장 큰 차이가 나타났다. 응력의 내부 분포 경향을 보았을 때 장방형 구조의 단면을 가진 Mtwo 및 NRT 파일에서 불연속적인 응력의 집중 부위가 관찰되었으며, 근관 외부로 파일을 제거하여 탄성 회복이 일어난 후의 잔류 응력도 NRT 파일에서 가장 높게 나타났다. 이상의 결과로 유추할 때, 삼각대칭 단면 구조를 가진 파일보다 S-형태의 단면과 변형된 사각 형태의 단면 등의 장방형 단면 구조의 파일이 파절의 위험성이 더 클 것으로 사료된다.

Influence of pre-existing surface defects on NiTi rotary instrument failure: A SEM study

  • Shin, Yu-Mi;Kim, Wu-Sung;Kum, Kee-Yeon
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.594-594
    • /
    • 2003
  • I. Objectives The purpose of this study is to determine if propagation of pre-existing manufacturing defects results in brittle fracture of NiTi rotary files by examining the fracture surface of the instrument by SEM, and to compare the fracture time of NiTi rotary files with different flute designs under cyclic loading. II. Materials and Methods This study examined three groups of rotary NiTi instruments (K3, ProFile, Hero). Of each group, 04 taper, size 30 and 06 taper, size 25 were selected.:120 in total. Surface defects were created by simulating the machining process of NiTi rotaries.(omitted)

  • PDF

The influence of different access cavity designs on fracture strength in endodontically treated teeth

  • Lee, Young-Gyun;Cho, Kyung-Mo;Kim, Jin-Woo
    • 대한치과보존학회:학술대회논문집
    • /
    • 대한치과보존학회 2003년도 제120회 추계학술대회 제 5차 한ㆍ일 치과보존학회 공동학술대회
    • /
    • pp.556-556
    • /
    • 2003
  • It is generally agreed that endodontic success often depends on canal debridement, disinfection and canal obturation. Access opening to a canal is one of the key to canal debridement. Advantages of straight line access opening are allowed a greater proportion of the root canal walls to be prepared than conventional lingual access cavities, minimized the loss of the tooth structure, reduced incidence of file fracture in curved canals. The purpose of this study is determine the influence of different access opening methods on fracture strength in endodontically treated teeth.(omitted)

  • PDF