• Title/Summary/Keyword: Filament Power Supply

Search Result 18, Processing Time 0.022 seconds

The Design and Implementation of Arc Power supply for Neutral Beam Injection (중성입자빔 가열을 위한 아크 전원 공급장치 설계 및 구현)

  • Lee, Hee-Jun;Shin, Soo-Cheol;Lee, Seung-Gyo;Jung, Yong-Chae;Won, Chung-Yuen
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.27 no.6
    • /
    • pp.50-58
    • /
    • 2013
  • The Neutral Beam Injection(NBI) generates ultra-high temperature energy in the tokamak of nuclear fusion. The NBI consists of filament power supply acceleration and deceleration power supply and arc power supply(APS). The APS has characteristics of low voltage and high current. APS generate arc through constant output of voltage and current. So this paper proposed suitable buck converter for low voltage and high current. The case of proposed buck converter used parallel switch because it can increase capacity and decrease conduction loss. When an arc is generated, the NBI chamber occur high voltage. And it will break output capacitor of buck converter. Therefore the output capacitor was removed in the proposed converter. Thus buck converter with constant output is the most important design of the output inductor. In this paper, designed APS verified operation of system and stability through simulation and prototype.

Start-up Control of LLC Resonant Inverter for Microwave Oven Application (전자레인지용 LLC 공진형 인버터의 기동 제어)

  • Kang, Kyelyong;Kim, Heung-Geun;Cha, Honnyong
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.22 no.5
    • /
    • pp.463-468
    • /
    • 2017
  • One of the most critical part for magnetron driving in microwave oven is start-up control. For this, switching frequency of resonant inverter should be carefully controlled in order to supply sufficient power to the filament of the magnetron and to prevent rectifier diode from destruction caused by the excessive voltage across them. This paper proposes a novel start-up control strategy for LLC resonant inverter for microwave oven considering the non-oscillation mode time and the magnetron voltage during the start-up process. The validity of the proposed method is verified through the experiment with 1,200W microwave oven using LLC resonant inverter.

Quasi-monochromatic Parallel Radiography Achieved with a Polycapillary Plate

  • Sato, Eiichi;Komatsu, Makoto;Hayasi, Yasuomi;Tanaka, Etsuro;Mori, Hidezo;Kawai, Toshiaki;Ichimaru, Toshio;Takayama, Kazuyoshi;Ido, Hideaki
    • Proceedings of the Korean Society of Medical Physics Conference
    • /
    • 2002.09a
    • /
    • pp.418-421
    • /
    • 2002
  • Fundamental study on quasi-monochromatic parallel radiography using a polycapillary plate and a plane-focus x-ray tube is described. The x-ray generator consists of a negative high-voltage power supply, a filament (hot cathode) power supply, and an x-ray tube. The negative high-voltage is applied to the cathode electrode, and the transmission type target (anode) is connected to the ground potential. The maximum voltage and current of the power supply were -100 kV (peak value) and 3.0 mA, respectively. In this experiment, the tube voltage was regulated from 20 to 25 kV, and the tube current was regulated by the filament temperature and ranged from 1.0 to 3.0 mA. The exposure time is controlled in order to obtain optimum film density, and the focal spot diameter was about 10 mm. The polycapillary plate is J5022-21 made by Hamamatsu Photonics Inc., and the outside and effective diameters are 87 and 77 mm, respectively. The thickness and the hole diameter of the polycapillary are 1.0 mm and 25 ${\mu}$m, respectively. The x-rays from the tube are formed into parallel beam by the polycapillary, and the radiogram is taken using an industrial x-ray film of Fuji IX 100 without using a screen. In the measurement of image resolution, we employed three brass spacers of 2, 30, and 60 mm in height. By the test chart, the resolution fell according to increases in the spacer height without using a polycapillary. In contrast, the resolution slightly fell with corresponding increases in the height by the polycapillary. In angiography, fine blood vessels of about 100 ${\mu}$m are clearly visible.

  • PDF

Improved Uniformity in Resistive Switching Characteristics of GeSe Thin Film by Ag Nanocrystals

  • Park, Ye-Na;Shin, Tae-Jun;Lee, Hyun-Jin;Lee, Ji-Soo;Jeong, Yong-Ki;Ahn, So-Hyun;Lee, On-You;Kim, Jang-Han;Nam, Ki-Hyun;Chung, Hong-Bay
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2013.08a
    • /
    • pp.237.2-237.2
    • /
    • 2013
  • ReRAM cell, also known as conductive bridging RAM (CBRAM), is a resistive switching memory based on non-volatile formation and dissolution of conductive filament in a solid electrolyte [1,2]. Especially, Chalcogenide-based ReRAM have become a promising candidate due to the simple structure, high density and low power operation than other types of ReRAM but the uniformity of switching parameter is undesirable. It is because diffusion of ions from anode to cathode in solid electrolyte layer is random [3]. That is to say, the formation of conductive filament is not go through the same paths in each switching cycle which is one of the major obstacles for performance improvement of ReRAM devices. Therefore, to control of nonuniform conductive filament formation is a key point to achieve a high performance ReRAM. In this paper, we demonstrated the enhanced repeatable bipolar resistive switching memory characteristics by spreading the Ag nanocrystals (Ag NCs) on amorphous GeSe layer compared to the conventional Ag/GeSe/Pt structure without Ag NCs. The Ag NCs and Ag top electrode act as a metal supply source of our devices. Excellent resistive switching memory characteristics were obtained and improvement of voltage distribution was achieved from the Al/Ag NCs/GeSe/Pt structure. At the same time, a stable DC endurance (>100 cycles) and an excellent data retention (>104 sec) properties was found from the Al/Ag NCs/GeSe/ Pt structured ReRAMs.

  • PDF

Development of a low energy ion irradiation system for erosion test of first mirror in fusion devices

  • Kihyun Lee;YoungHwa An;Bongki Jung;Boseong Kim;Yoo kwan Kim
    • Nuclear Engineering and Technology
    • /
    • v.56 no.1
    • /
    • pp.70-77
    • /
    • 2024
  • A low energy ion irradiation system based on the deuterium arc ion source with a high perveance of 1 µP for a single extraction aperture has been successfully developed for the investigation of ion irradiation on plasma-facing components including the first mirror of plasma optical diagnostics system. Under the optimum operating condition for mirror testing, the ion source has a beam energy of 200 eV and a current density of 3.7 mA/cm2. The ion source comprises a magnetic cusp-type plasma source, an extraction system, a target system with a Faraday cup, and a power supply control system to ensure stable long time operation. Operation parameters of plasma source such as pressure, filament current, and arc power with D2 discharge gas were optimized for beam extraction by measuring plasma parameters with a Langmuir probe. The diode electrode extraction system was designed by IGUN simulation to optimize for 1 µP perveance. It was successfully demonstrated that the ion beam current of ~4 mA can be extracted through the 10 mm aperture from the developed ion source. The target system with the Faraday cup is also developed to measure the beam current. With the assistance of the power control system, ion beams are extracted while maintaining a consistent arc power for more than 10 min of continuous operation.

High Voltage Resonant DC-DC Converter Design for X-Ray Imaging (X-Ray 진찰용 고전압 공진형 DC-DC 컨버터 설계)

  • Baek, Jong-Mu;Joo, Hae-Jong;Cho, Moon-Taek;Lee, Chung-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.4 no.4
    • /
    • pp.11-16
    • /
    • 2010
  • In this paper, including the X-ray high voltage resonant inverter generators and high frequency high voltage transformer operating systems is proposed. X-ray generator removes the noise and was smaller, 50[kHz] to work more with the driving frequencies, and that occurred when the normal power supply available due to noise, survey the conditions and solve the problems of the poor was a problem. In addition, X-ray tube voltage, frequency controllers and tube current controller filament heating voltage transformer for high frequency transformer design and manufacture of doing X-ray devices were to become more efficient operation.

Effects of Argon-plasma Jet on the Cytoskeleton of Fibroblasts: Implications of a New Approach for Cancer Therapy (Fibroblasts 세포주의 세포골격에서 아르곤 플라즈마의 효과: Cancer Therapy의 새로운 접근방법)

  • Han, Ji-Hye;Nam, Min-Kyung;Kim, Yong-Hee;Park, Dae-Wook;Choi, Eun Ha;Rhim, Hyangshuk
    • KSBB Journal
    • /
    • v.27 no.5
    • /
    • pp.308-312
    • /
    • 2012
  • Argon-plasma jet (Ar-PJ) is generated by ionizing Ar gas, and the resulting Ar-PJ consists of a mixture of neutral particles, positive ions, negative electrons, and various reactive species. Although Ar-PJ has been used in various biomedical applications, little is known about the biological effects on cells located near the plasma-exposed region. Here, we investigated the effects of the Ar-PJ on actin cytoskeleton of mouse embryonic fibroblasts (MEFs) in response to indirect as well as direct exposure to Ar-PJ. This Ar-PJ was generated at 500 mL/min of flow rate and 100 V electric power by our device mainly consisting of electrodes, dielectrics, and a high-voltage power supply. Because actin cytoskeleton is the key cellular machinery involved in cellular movement and is implicated in regulation of cancer metastasis and thus resulting in a highly desirable cancer therapeutic target, we examined the actin filament architectures in Ar-PJ-treated MEFs by staining with an actin-specific phalloidin labeled with fluorescent dye. Interestingly, the Ar-PJ treatment causes destabilization of actin filament architectures in the regions indirectly exposed to Ar-PJ, but no differences in MEFs treated with Ar gas alone and in untreated cell control, indicating that this phenomenon is a specific cellular response against Ar-PJ in the live cells, which are indirectly exposed to Ar-PJ. Collectively, our study raises the possibility that Ar-PJ may have potential as anti-cancer drug effect through direct destabilization of the actin cytoskeleton.

A Study on the Stability of the Accelerating Voltages in Scanning Electron Microscopy (주사전자현미경에서 가속전압의 안정성 연구)

  • Bae, Moon-Seob;Oh, Sang-Ho;Cho, Yang-Koo;Lee, Hwack-Joo
    • Applied Microscopy
    • /
    • v.34 no.1
    • /
    • pp.51-59
    • /
    • 2004
  • The high acceleration voltage system used in scanning electron microscope were designed and manufactured to test its stability. The Cockcroft-Walton circuits are used both in the cathode voltage up to -30 kV and in the Wehnelt cylinder of -2 kV. The operating voltage of 6 V was applied to the heating of the filament. The wave forms which are formed in the second leg of the high voltage transformer were observed in the oscilloscope with 2 V of DC input. When the high voltages were in the range between 5 kV and 12 kV, the highest value of the stabilities of the generated voltages was obtained as 0.002%.