• 제목/요약/키워드: Field wall

검색결과 1,608건 처리시간 0.026초

Direct Numerical Simulation of Turbulent Scalar Transport in a Channel with Wall Injection

  • Na, Yang
    • Journal of Mechanical Science and Technology
    • /
    • 제18권4호
    • /
    • pp.597-605
    • /
    • 2004
  • Turbulent temperature field in a channel subject to strong wall injection has been investigated via direct numerical simulation technique. These flows are pertinent to internal flows inside hybrid rocket motors. A simplified model problem where a regression process at the propellant surface is idealized by wall injection has been investigated to understand how the temperature field is modified. The effect of strong wall injection displaces thermal boundary layer away from the wall and this causes a sharp drop of friction temperature. Turbulent diffusivity and dissipation time scale for temperature field are found to show large variations in the streamwise direction under application of wall blowing. It is, thus, expected that more sophisticated turbulence models would be required to predict the disturbed temperature field accurately.

Concepts for Domain Wall Motion in Nanoscale Ferromagnetic Elements due to Spin Torque and in Particular Oersted Fields

  • Klaui, Mathias;Ilgaz, Dennis;Heyne, Lutz;Kim, June-Seo;Boulle, Olivier;Schieback, Christine;Zinser, Fabian;Krzyk, Stephen;Fonin, Mikhail;Rudiger, Ulrich;Backes, Dirk;Heyderman, Laura J.;Mentes, T.O.;Locatelli, A.
    • Journal of Magnetics
    • /
    • 제14권2호
    • /
    • pp.53-61
    • /
    • 2009
  • Herein, different concepts for domain wall propagation based on currents and fields that could potentially be used in magnetic data storage devices based on domains and domain walls are reviewed. By direct imaging, we show that vortex and transverse walls can be displaced using currents due to the spin transfer torque effect. For the case of field-induced wall motion, particular attention is paid to the influence of localized fields and local heating on the depinning and propagation of domain walls. Using an Au nanowire adjacent to a permalloy structure with a domain wall, the depinning field of the wall, when current pulses are injected into the Au nanowire, was studied. The current pulse drastically modified the depinning field, which depended on the interplay between the externally applied field direction and polarity of the current, leading subsequently to an Oersted field and heating of the permalloy at the interface with the Au wire. Placing the domain wall at various distances from the Au wire and studying different wall propagation directions, the range of Joule heating and Oersted field was determined; both effects could be separated. Approaches beyond conventional field- and current-induced wall displacement are briefly discussed.

Navier-Stokes Analysis of Pitching Delta Wings in a Wind Tunnel

  • Lee, Yung-Gyo
    • International Journal of Aeronautical and Space Sciences
    • /
    • 제2권2호
    • /
    • pp.28-38
    • /
    • 2001
  • A numerical method for the assessment and correction of tunnel wall interference effects on forced-oscillation testing is presented. The method is based on the wall pressure signature method using computed wall pressure distributions. The wall pressure field is computed using unsteady three-dimensional full Navier-Stokes solver for a 70-degree pitching delta wing in a wind tunnel. Approximately-factorized alternate direction implicit (AF-ADI) scheme is advanced in time by solving block tri-diagonal matrices. The algebraic Baldwin-Lomax turbulence, model is included to simulate the turbulent flow effect. Also, dual time sub-iteration with, local, time stepping is implemented to improve the convergence. The computed wall pressure field is then imposed as boundary conditions for Euler re-simulation to obtain the interference flow field. The static computation shows good agreement with experiments. The dynamic computation demonstrates reasonable physical phenomena with a good convergence history. The effects of the tunnel wall in upwash and blockage are analyzed using the computed interference flow field for several reduced frequencies and amplitudes. The corrected results by pressure signature method agree well with the results of free air conditions.

  • PDF

상시하중상태에서 박벽의 보강효과에 대한 연구 (Reinforcing Effect of Thin-wall at Serviceability Condition)

  • 김두환;윤성수;박진선
    • 한국농공학회논문집
    • /
    • 제52권2호
    • /
    • pp.11-17
    • /
    • 2010
  • For the reasonable analysis of design problems for agricultural facilities, considered the reinforcing effect of thin-wall. The most of agricultural structure is constructed small scale and have many purposes. Thus it has been designed temporary rather than permanent structure, and has relatively large slenderness ratio, small section and semi-rigid condition. Therefore many agricultural facilities are consist of relatively strong frame with weak wall at the viewpoint of stiffness and have not been reflected in the design. But the tension field influences to collapse of structure have already known. Therefore, we need quantification the effect of tension field at structural analysis. In this study, present the method of quantification the effect of tension field that came out thin-plate surrounded by high stiffness frame. The numerical results show that the effect of tension field effect for thin-wall is about 5% of the sectional area of frame in study agricultural facilities.

차음성능이 향상된 경량벽체 개발 및 성능평가 연구 (A Study on the Development of Lightweight Wall for Sound Transmission Loss and Field Test Results of the Dry-Wall System)

  • 이병권;배상환;홍천화
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2004년도 춘계학술대회논문집
    • /
    • pp.699-704
    • /
    • 2004
  • As being inconvenient to apply reinforced concrete structure to high-rise buildings, it is applied steel structured system. Therefore light-weight wall systems are applied as partition wall to reduce the self-load of the building. But, the required performances of a light-weight wall are not evaluated systematically. As a field survey result, partition walls of house-to-house were not showed their respected performances, so the dwellers are feel so worse the quality of the whole building. In steel-structured high-rise buildings especially, occupant's dissatisfaction concerned indoor noise was high because curtain wall systems having a high air-tight performance isolate the outdoor noise making masking effect. Therefore wall systems which have high performances of sound insulation and air-tightness are required in high-rise buildings. As a result, a new drywall system was presented and the performance was verified with field test.

  • PDF

광자기 기억장치에서의 자화반전 특성 모델링 (A Modelling of magnetization reversal characteristics in magneto-optic memory system)

  • 한은실;이광형;조순철
    • 한국통신학회논문지
    • /
    • 제19권10호
    • /
    • pp.1849-1860
    • /
    • 1994
  • 본 논문은 비정질 회토류 천이 급속 박막내에서의 자벽 역학(Magnetic domain wall dynamics)을 란다우 리프쉬츠 길버트 (Landau Lifshitz Gilbert) 방정식을 이용한 수치적 해석을 수행하여 연구하였다. 박막을 이차원 정방형 격자($30\times30$)로 나누고, 각 격자 셀(Cell)에 쌍극자간 존재한다고 상정하여, 이들 쌍극자간의 상호 교환 작용과 자기 이방성, 외부 인가 자계, 그리고 감자계의 영향이 고려되었다. 단축 자기 이방성이 존재하고 역방향의 자화가 존재한다고 가정된 상태에서 자벽이 형성되는 시간과 자벽의 두께를 알아보았다. 또한 외부 자계의 인가에 따른 자벽 이동을 연구하였다. 시뮬레이션 결과, 감자계를 고려했을 때 자벽 형성 시간이 상당히 빨라졌고, 평균 자벽의 이동도(Mobility)는 약간 증가되었다.

  • PDF

FORMULATION OF NEAR AND FAR ACOUSTIC FIELD FROM AN INCOMPRESSIBLE FLOW FLRCTUATION AROUND THE RIGID WALL

  • Ryu, Ki-Wahn;Lee, Duck-Joo
    • 한국음향학회:학술대회논문집
    • /
    • 한국음향학회 1996년도 제11회 수중음향학 학술발표회 논문집 11th Underwater Acoustics Symposium Proceedings
    • /
    • pp.59-62
    • /
    • 1996
  • A numerical study of a two-dimensional acoustic field is carride ort for a spinning vortex pair located neat a wall to investigate the effect of the wall from the spinning quadrupole source in unsteady vortical flows. Based on the known incompressible flow field, the perturbed compressible acoustic terms derived from the Euler equations are calculated. Non-reflecting boundary conditions on the free field and the solid boundary conditions are developed for a generalized curvilinear coordinates system to investigate the effect of a curced wall. It is concluded that the sound generated by the quadrupole sources of unsteady vortical flows in the presence of a flat wall or a circular cylinder can be calculated by using the source terms of hydrodynamic flow fluctuations in both near and far acoustic fields simultaneously.

  • PDF

현장계측을 통한 블럭식 보강토 옹벽의 거동분석 (Analysis of the Segmental Reinforced Retaining Wall Behavior by Field Monitoring)

  • 신은철;이창섭
    • 한국지반신소재학회논문집
    • /
    • 제3권1호
    • /
    • pp.3-15
    • /
    • 2004
  • 1990년대 후반부터는 시공의 간편성과 유연한 벽면 형상이 가능한 블럭식 보강토 옹벽의 시공사례가 급격히 증가하고 있는 추세이다. 그러나, 기존의 연구자료와 비교해 볼 때 블럭의 형태, 보강재, 보강재와 블록의 연결형태, 뒤채움재에 따라 상이한 거동을 할 개연성이 있다. 따라서, 이 연구는 블럭식 보강토 옹벽의 거동을 수평 수직 토압계, 경사계, 침하판, 스트레인 게이지, 변형핀 등의 계측기를 설치하여 시공중과 시공후의 보강토 옹벽의 거동을 평가하였다. 또한, 현장에 적용된 보강토 옹벽의 설계 프로그램인 SRWall에 의해 산정된 안전율과 이론에 의해 도출된 안전율을 상호 비교함으로써 현장 계측결과와 설계프로그램에 의한 안전성을 검증하였다. 9개월 동안의 현장계측을 통한 연구 결과를 종합해보면, 블럭식 보강토 옹벽은 양호한 다짐관리와 시공기간의 장기화로 인한 변위는 매우 미미한 것으로 판명되었다. SRWall을 활용하여 도출한 안전율과 보강토 옹벽의 안전율을 평가한 결과 이론에 의해 도출한 안전율과 유사한 것으로 판명되었다.

  • PDF

정수지 내 유동 특성과 유공벽을 이용한 소독능 변화에 대한 수치 해석적 연구 (Numerical Analysis for Characteristics of Flow Fields and Disinfection Performances in the Clearwell with a Porous media Wall)

  • 이석원;리광훈;구자용
    • 상하수도학회지
    • /
    • 제21권6호
    • /
    • pp.755-761
    • /
    • 2007
  • Disinfection performance in clearwell is generally measured by CT, which is expressed by $C{\times}T$. C is represented by disinfection concentration, and T is represented by $T_{10}$ which means 90% contact time in clearwell. In order to improve Disinfection performance, augmentation of $T_{10}$ is required. Guide wall has been generally used to improve $T_{10}$ because $T_{10}$ changes according to flow field. In this study, porous media is proposed instead of guide wall, and disinfection performance between guide wall and porous media wall are compared. Flow field and $T_{10}$ in each clearwell are investigated as well. Improved Disinfection performance appear in case of porous media wall compare to guide wall, and best performance occur in porosity factor ${\beta}$ 1e+4.

Simulation of the Effect of Soft Underlayer Domain Wall Structure on Output Signal in Perpendicular Magnetic Recording

  • Kim, Eun-Sik;Lim, Chee-Kheng;Kim, Yong-Su;Lee, Ju
    • Journal of Magnetics
    • /
    • 제11권2호
    • /
    • pp.83-86
    • /
    • 2006
  • Controlling magnetic domains in soft underlayer (SUL) of perpendicular magnetic recording (PMR) is an important issue for the application of PMR in HDD. We studied the magnetic domain structures in SUL using the finite element based micromagnetic simulation (FEMM) for the SUL models with different thicknesses. The purpose is to simulate the magnetic domain wall noise when the SUL thickness and saturation magnetization are changed. The simulation results show that a 15 nm SUL forms simpler Neel wall domain wall pattern and 40 nm SUL forms complex Bloch wall. To visualize the effect of these domain walls stray field at a read sensor position, the magnetic stray field of the domain walls at air bearing surface (ABS) which is 50 nm above the SUL was simulated and the results imply that Bloch walls have stronger stray field with more complicated field patterns than Neel walls and this becomes a significant noise source. Therefore, the thickness of the SUL should be controlled to avoid the formation of Bloch walls.