• 제목/요약/키워드: Field test

검색결과 9,419건 처리시간 0.045초

촉진열화 및 장기폭로시험에 의한 고성능 PC패널의 내구성능 및 열화특성 (Characterization of Durability of PC panel by Accelerating Test in Deterioration Chamber and Long-Term Field Exposure Test)

  • 마상준;장필성;최재석;주정민
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2008년도 추계 학술발표회
    • /
    • pp.1549-1554
    • /
    • 2008
  • In this paper, The evaluation of durability of the PC Panel lining for tunnel structure was examined through the rapid test by carbonation and freezing and thawing. Also for the purpose of improvement of durability. Namely, the durable characteristics of PC Panel lining by carbonation and freezing and thawing, was evaluated by rapid test and long-term field exposure test and main influence factors were derived. As a result of test, Correlation of accelerating test in deterioration chamber and long-term field exposure test, it will be expected that the proposed correlation well to the prediction of life expectancy of structure and is contributed greatly in the future.

  • PDF

현장밀도시험을 이용한 암성토 체적환산계수 산정에 관한 연구 (The Estimation of Volume Conversion Factor of Rock Fill using Field Density Test)

  • 박종범;마명수
    • 한국지반신소재학회논문집
    • /
    • 제16권1호
    • /
    • pp.9-17
    • /
    • 2017
  • 본 연구에서는 암성토의 토공량 설계에 대한 대책방안으로 현장밀도시험을 수행하였으며, 현장밀도시험결과 암성토부의 발파암 평균 체적환산계수는 1.001로서 풍화암의 체적환산계수 1.1보다 작은 값이 나타났다. 이와 같이 암성토의 경우 여러 가지 현상에 의해 토공량의 증감 원인을 제공하고 있으나, 이에 대한 조사 및 시험방법 등 구체적인 기술 등이 부족한 실정이므로 본 연구결과에서와 같이 체적환산계수를 검토하기 위한 조사방법으로 현장밀도시험방법이 매우 유용한 방법임을 확인하였다.

XLPE 케이블의 PD 검출 필터 시험 (Filter Test for Detecting Partial Discharge in XLPE Cable)

  • 조재철;최용성
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 추계학술대회 논문집 전기설비전문위원
    • /
    • pp.218-221
    • /
    • 2008
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under- ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektro- nix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

현장시험에 의한 소수력발전용 튜블러수차시스템 성능계측 (Performance Measurement of a Tubular Type Turbine System for Small Hydropower by Field Test)

  • 황영호;이영호;최영도
    • 한국유체기계학회 논문집
    • /
    • 제14권6호
    • /
    • pp.5-10
    • /
    • 2011
  • Recently, small hydropower attracts attention because of its renewable, clean and abundant energy resources to develop. Therefore, a tubular type hydro turbine is proposed for small hydropower in this study because the turbine has relatively simple structure and high possibility of applying to small hydropower. The purpose of this study is to investigate the performance characteristics of the turbine by field test. Field test iss conducted using one tubular turbine system as well as serial arrangement system by two tubular turbines taking into consideration of actual operation conditions. The results show that efficiency of test turbine changes considerably by the runner vane angle. Best efficiency of one turbine arrangement is higher than that of two turbine serial arrangement.

XLPE 케이블의 PD 검출 필터 시험 (Filter Test for Detecting Partial Discharge in XLPE Cable)

  • 김대열;윤주호;최용성;박대희;이경섭
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2007년도 춘계학술대회 논문집 전기설비전문위원
    • /
    • pp.72-74
    • /
    • 2007
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as underground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

22.9kV XLPE 케이블 PD 검출용 필터 시험 (Filter Test for Detecting Partial Discharge in 22.9kV XLPE Cable)

  • 이용성;김정윤;김석종;이경용;최용성;박대희
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 C
    • /
    • pp.2277-2279
    • /
    • 2005
  • Due to a variable noises in the field underground lines, clear technology of noises is very important in the diagnosis technology of partial discharge. Therefore we progressed filter test to improve the measuring test of partial discharge in a field. We applied to field test after making W-LC filter for partial discharge measurement, and then designed experimental environment such as under-ground distribution lines of field. Measuring sensor for test was UHF sensor. And we analysed those using the Lemke Probe and oscilloscope (TDS-3054, Tektronix). Finally, we obtained excellent data of noise decrement in the joint box of 22.9[kV] distribution lines from above experiment.

  • PDF

The influence of model surface roughness on wind loads of the RC chimney by comparing the full-scale measurements and wind tunnel simulations

  • Chen, Chern-Hwa;Chang, Cheng-Hsin;Lin, Yuh-Yi
    • Wind and Structures
    • /
    • 제16권2호
    • /
    • pp.137-156
    • /
    • 2013
  • A wind tunnel test of a scaled-down model and field measurement were effective methods for elucidating the aerodynamic behavior of a chimney under a wind load. Therefore, the relationship between the results of the wind tunnel test and the field measurement had to be determined. Accordingly, the set-up and testing method in the wind tunnel had to be modified from the field measurement to simulate the real behavior of a chimney under the wind flow with a larger Reynolds number. It enabled the results of the wind tunnel tests to be correlated with the field measurement. The model surface roughness and different turbulence intensity flows were added to the test. The simulated results of the wind tunnel test agreed with the full-scale measurements in the mean surface pressure distribution behavior.

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • 제8권1호
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

RC 슬래브 교량의 현장재하시험을 통한 안전성 평가 (Safety Evaluation through Field Load Test of RC Slab Bridge)

  • 조한민
    • 도시과학
    • /
    • 제11권1호
    • /
    • pp.9-13
    • /
    • 2022
  • Currently, RC slab bridges in use in Korea account for most of the total bridges, and bridges with a service life of 20 years or more account for about 75%. However, most of these RC slab bridges have a span of less than 20m and are not included in the first and second types of facilities, so maintenance is very neglected. Therefore, in this study, field load test is performed on an aged RC slab bridge, and the performance evaluation is performed based on the structural response results (deflection, impact coefficient, natural frequency, etc.) of the bridge obtained through field load test. In addition, the performance evaluation results obtained through the load test are intended to be used as basic data for the damage evaluation process of the bridge currently under development.

Calculation method for settlement of micropile installed in rock layers through field tests

  • Hwang, TaeHyun;Cho, JungMin;Lee, YeongSaeng
    • Geomechanics and Engineering
    • /
    • 제31권2호
    • /
    • pp.197-208
    • /
    • 2022
  • Micropiles consisting of steel bars and grouts are commonly used in underpinning methods to reinforce supports or to suppress the subsidence of existing structures. Recently, applications in the field of geotechnical engineering have expanded. Despite the increasing use of micropiles are used, the PHC or steel pile formula is still applied for the settlement amount of micropiles. Compared with field test results, the amount of micropile subsidence obtained from the existing method may result in a very large error in the displacement of the micropile. Therefore, it is difficult to utilize micropiles effectively. Hence, to solve this problem, this study evaluated the behaviors and support characteristics of micropiles through field compression and tensile tests, and proposed a method for predicting the amounts of their subsidence. To confirm the appropriateness of the proposed method, field test results and the results obtained using the proposed method were compared. It was found that the settlement amounts of the micropiles as predicted through the existing method were significantly overestimated (error ≈ 50-80%) relative to the field test results, whereas the settlement errors of the piles predicted through the proposed method decreased (error ≈6-32%). Thus, it is possible to reduce the previously overestimated amount of settlement, and the modified method of this study allows more efficient design than the conventional method.