• Title/Summary/Keyword: Field simulation

Search Result 5,641, Processing Time 0.037 seconds

Monte-Carlo Simulations of Non-ergodic Solute Transport from Line Sources in Isotropic Mildly Heterogeneous Aquifers (불균질 등방 대수층 내 선형오염원으로부터 기원된 비에르고딕 용질 이동에 관한 몬테카를로 시뮬레이션)

  • Seo Byong-min
    • Journal of Soil and Groundwater Environment
    • /
    • v.10 no.6
    • /
    • pp.20-31
    • /
    • 2005
  • Three dimensional Monte-Carlo simulations of non-ergodic transport of a lion-reactive solute plume by steady-state groundwater flow under a uniform mean velocity in isotropic heterogeneous aquifers were conducted. The log-normally distributed hydraulic conductivity, K(x), is modeled as a random field. Significant efforts are made to reduce tile simulation uncertainties. Ensemble averages of the second spatial moments of the plume and plume centroid variances were simulated with 1600 Monte Carlo runs for three variances of log K, ${\sigma}_Y^2=0.09,\;0.23$, and 0.46, and three dimensionless lengths of line plume sources normal to the mean velocity. The simulated second spatial moment and the plume centroid variance in longitudinal direction fit well to the first order theoretical results while the simulated transverse moments are generally larger than the first order results. The first order theoretical results significantly underestimated the simulated dimensionless transverse moments for the aquifers of large ${\sigma}_Y^2$ and large dimensionless time. The ergodic condition for the second spatial moments is far from reaching in all cases simulated, and transport In transverse directions may reach ergodic condition much slower than that in longitudinal direction. The evolution of the contaminant transported in a heterogeneous aquifer is not affected by the shape of the initial plume but affected mainly by the degree of the heterogeneity and the size of the initial plume.

Evaluation of Xerostomia Following 3 Dimensional Conformal Radiotherapy for Nasopharyngeal Cancer Patients (3차원 입체조형 방사선치료를 시행받은 코인두암 환자에서의 구강건조증 분석)

  • Park Young-Je;Park Won;Ju Sang-Gyu;Nam Hee-Rim;Oh Dong-Ryul;Park Hee-Chul;Ahn Yong-Chan
    • Radiation Oncology Journal
    • /
    • v.24 no.2
    • /
    • pp.81-87
    • /
    • 2006
  • Purose: This study is to evaluate the xerostomia following 3-dimensional conformal radiation therapy (3D CRT) in nasopharynx cancer patients using the xerostomia questionnaire score (XQS). Materials and Methods: Questionnaire study was done on 51 patients with nasopharynx cancer who received 3D CRT from Dec. 2000 to Aug. 2005. 3D CRT technique is based on 'serial shrinking field' concept by 3 times of computed tomography (CT) simulation. Total target dose to the primary tumor was 72 Gy with 1.8 Gy daily fractions. Xerostomia was assessed with 4-questions XQS, and the associations between XQS and time elapsed after RT, age, sex, stage, concurrent chemotherapy, and parotid dose were analyzed. Results: Concurrent chemotherapy was given to 40 patients and RT alone was given to 11 patients. The median time elapsed after 3D CRT was 20 ($1{\sim}58$) months and the mean XQS of all 51 patients was $8.4{\pm}1.9\;(6{\sim}14)$. XQS continuously and significantly decreased over time after 3D CRT ($X^2$=-0.484, p<0.05). There was no significant difference in XQS according to sex, age, and stag. However, XQS of concurrent chemotherapy patients was significantly higher than RT alone patients (P=0.001). XQS of patients receiving total mean parotid dose ${\ge}35 Gy$ was significantly higher than <35 Gy (p=0.05). Decreasing tendency of XQS over time after 3D CRT was observed. Concurrent chemotherapy and total mean parotid dose ${\ge}35 Gy$ were suggested to adversely affect radiation-induced xerostomia.

Energy-Efficient Division Protocol for Mobile Sink Groups in Wireless Sensor Network (무선 센서 네트워크에서 이동 싱크 그룹의 분리를 지원하기 위한 라우팅 프로토콜)

  • Jang, Jaeyoung;Lee, Euisin
    • KIPS Transactions on Computer and Communication Systems
    • /
    • v.6 no.1
    • /
    • pp.1-8
    • /
    • 2017
  • Communications for mobile sink groups such as rescue teams or platoons bring about a new challenging issue for handling mobility in wireless sensor networks. To do this, many studies have been proposed to support mobile sink groups. When closely looking at mobile sink groups, they can be divided into (multiple) small groups according to the property of applications. For example, a platoon can be divided into multiple squads to carry out its mission in the battle field. However, the previous studies cannot efficiently support the division of mobile sink groups because they do not address three challenging issues engendered by the mobile sink group division. The first issue is to select a leader sink for a new small mobile sink group. The efficient data delivery from a source to small mobile sink groups is the second issue. Last, the third issue is to share data between leader sinks of small mobile sink groups. Thus, this paper proposes a routing protocol to efficiently support the division of mobile sink groups by solving the three challenging issues. For the first issue, the proposed protocol selects a leader sink of a new small mobile sink group which provide a minimum summation of the distance between the new leader sink and the previous leader sink and the distance from the new leader sink to all of its member sinks. For the efficient data delivery from a source to small mobile sink groups in the second issue, the proposed protocol determines the path to minimize the data dissemination distance from source to small mobile sink group by calculating with the location information of both the source and the leader sinks. With regard to the third issue, the proposed protocol exploits member sinks located among leader sinks to provide efficient data sharing among leaders sinks by considering the location information of member sinks. Simulation results verified that the proposed protocol is superior to the previous protocol in terms of the energy consumption.

Hydro-Mechanical Modelling of Fault Slip Induced by Water Injection: DECOVALEX-2019 TASK B (Step 1) (유체 주입에 의한 단층의 수리역학적 거동 해석: 국제공동연구 DECOVALEX-2019 Task B 연구 현황(Step 1))

  • Park, Jung-Wook;Park, Eui-Seob;Kim, Taehyun;Lee, Changsoo;Lee, Jaewon
    • Tunnel and Underground Space
    • /
    • v.28 no.5
    • /
    • pp.400-425
    • /
    • 2018
  • This study presents the research results and current status of the DECOVALEX-2019 project Task B. Task B named 'Fault slip modelling' is aiming at developing a numerical method to simulate the coupled hydro-mechanical behavior of fault, including slip or reactivation, induced by water injection. The first research step of Task B is a benchmark simulation which is designed for the modelling teams to familiarize themselves with the problem and to set up their own codes to reproduce the hydro-mechanical coupling between the fault hydraulic transmissivity and the mechanically-induced displacement. We reproduced the coupled hydro-mechanical process of fault slip using TOUGH-FLAC simulator. The fluid flow along a fault was modelled with solid elements and governed by Darcy's law with the cubic law in TOUGH2, whereas the mechanical behavior of a single fault was represented by creating interface elements between two separating rock blocks in FLAC3D. A methodology to formulate the hydro-mechanical coupling relations of two different hydraulic aperture models and link the solid element of TOUGH2 and the interface element of FLAC3D was suggested. In addition, we developed a coupling module to update the changes in geometric features (mesh) and hydrological properties of fault caused by water injection at every calculation step for TOUGH-FLAC simulator. Then, the transient responses of the fault, including elastic deformation, reactivation, progressive evolutions of pathway, pressure distribution and water injection rate, to stepwise pressurization were examined during the simulations. The results of the simulations suggest that the developed model can provide a reasonable prediction of the hydro-mechanical behavior related to fault reactivation. The numerical model will be enhanced by continuing collaboration and interaction with other research teams of DECOLVAEX-2019 Task B and validated using the field data from fault activation experiments in a further study.

A Case Study On Digital Education Design In Foreign Countries By Analysis Education Condition (선진학교 교육현황 분석을 통한 디지털 교육매체 디자인 국외 사례 연구)

  • Kim, Jung-Hee
    • Cartoon and Animation Studies
    • /
    • s.30
    • /
    • pp.201-219
    • /
    • 2013
  • Development of digital media in education field at America, UK, Japan etc bring big progress on digital device if education. Japan bring huge progress on digital education by nationally. UK use huge a national budget at digital education development and Sweden which is advanced country of education and a welfare state. Especially UK and Sweden's digital education markets are full now aspect more high quality design. Korea which is advanced country of IT adopted digital text book 2007 with mathematics, through science and English digital text book through the state. Korea's digital text book is in a transition period. that needs case study of advanced country of education for setting design guide and educational effect to digital education media and device plan. All researches are based on LG europe design center at London. Analysis by using KJ method, survey of questionnaire, heuristic method at 4 schools in UK and Sweden. Through analytical researches want to more reality simulation at digital education, and high quality contents with digital socialization. co-work with analog, can get any where, anytime user want without any difficulty. Also interactive GUI design of digital education device to easy to access for user. When plan Digital text book content and design needs methodical design guide for target who students and environment an in-depth study of the appraisal and method. The results of the research are introduce the design plan as a basic research and giving useful design plan to make digital educational media in Korea industrial aspect.

Analyses of the Setup Errors using on Board Imager (OBI) (On Board Imager (OBI)를 이용한 Setup Error 분석에 대한 연구)

  • Kim, Jong-Deok;Lee, Haeng-O;You, Jae-Man;Ji, Dong-Hwa;Song, Ju-Young
    • The Journal of Korean Society for Radiation Therapy
    • /
    • v.19 no.1
    • /
    • pp.1-5
    • /
    • 2007
  • Purpose: The accuracy and advantages of OBI(On Board Imager) against the conventional method like film and EPID for the setup error correction were evaluated with the analysis of the accumulated data which were produced in the process of setup error correction using OBI. Materials and Methods: The results of setup error correction using OBI system were analyzed for the 130 patients who had been planned for 3 dimensional conformal radiation therapy during March 2006 and May 2006. Two kilo voltage images acquired in the orthogonal direction were fused and compared with reference setup images. The setup errors in the direction of vertical, lateral, longitudinal axis were recorded and calculated the distance from the isocenter. The corrected setup error were analyzed according to the lesion and the degree of shift variations. Results: There was no setup error in the 41.5% of total analyzed patients and setup errors between 1mm and 5mm were found in the 52.3%. 6.1% patients showed the more than 5mm shift and this error were verified as a difference of setup position and the movement of patient in a treatment room. Conclusion: The setup error analysis using OBI in this study verified that the conventional setup process in accordance with the laser and field light was not enough to get rid of the setup error. The KV images acquired using OBI provided good image quality for comparing with simulation images and much lower patients' exposure dose compared with conventional method of using EPID. These advantages of OBI system which were confirmed in this study proved the accuracy and priority of OBI system in the process of IGRT(Image Guided Radiation Therapy).

  • PDF

Research of Diffusion Bonding of Tungsten/Copper and Their Properties under High Heat Flux

  • Li, Jun;Yang, Jianfeng
    • Proceedings of the Materials Research Society of Korea Conference
    • /
    • 2011.05a
    • /
    • pp.14-14
    • /
    • 2011
  • W (tungsten)-alloys will be the most promising plasma facing armor materials in highly loaded plasma interactive components of the next step fusion reactors due to its high melting point, high sputtering resistance and low deuterium/tritium retention. The bonding technology of tungsten to Cu alloy was one of the key issues. In this paper, W/CuCrZr diffusion bonding has been performed successfully by inserting pure metal interlay. The joint microstructure, interfacial elements migration and phase composition were analyzed by SEM, EDS, XRD, and the joint shear strength and micro-hardness were investigated. The mock-ups were fabricated successfully with diffusion bonding and the cladding technology respectively, and the high heat flux test and thermal fatigue test were carried out under actively cooling condition. When Ni foil was used for the bonding of tungsten to CuCrZr, two reaction layers, Ni4W and Ni(W) layer, appeared between the tungsten and Ni interlayer with the optimized condition. Even though Ni4W is hard and brittle, and the strength of the joint was oppositely increased (217 MPa) due primarily to extremely small thicknesses (2~3 ${\mu}m$). When Ti foil was selected as the interlayer, the Ti foil diffused quickly with Cu and was transformed into liquid phase at $1,000^{\circ}C$. Almost all of the liquid was extruded out of the interface zone under bonding pressure, and an extremely thin residual layer (1~2 ${\mu}m$) of the liquid phase was retained between the tungsten and CuCrZr, which shear strength exceeded 160 MPa. When Ni/Ti/Ni multiple interlayers were used for bonding of tungsten to CuCrZr, a large number of intermetallic compound ($Ni_4W/NiTi_2/NiTi/Ni_3T$) were formed for the interdiffusion among W, Ni and Ti. Therefore, the shear strength of the joint was low and just about 85 MPa. The residual stresses in the clad samples with flat, arc, rectangle and trapezoid interface were estimated by Finite Element Analysis. The simulation results show that the flat clad sample was subjected maximum residual stress at the edge of the interface, which could be cracked at the edge and propagated along the interface. As for the rectangle and trapezoid interface, the residual stresses of the interface were lower than that of the flat interface, and the interface of the arc clad sample have lowest residual stress and all of the residual stress with arc interface were divided into different grooved zones, so the probabilities of cracking and propagation were lower than other interfaces. The residual stresses of the mock-ups under high heat flux of 10 $MW/m^2$ were estimated by Finite Element Analysis. The tungsten of the flat interfaces was subjected to tensile stresses (positive $S_x$), and the CuCrZr was subjected to compressive stresses (negative $S_x$). If the interface have a little microcrack, the tungsten of joint was more liable to propagate than the CuCrZr due to the brittle of the tungsten. However, when the flat interface was substituted by arc interfaces, the periodical residual stresses in the joining region were either released or formed a stress field prohibiting the growth or nucleation of the interfacial cracks. Thermal fatigue tests were performed on the mock-ups of flat and arc interface under the heat flux of 10 $MW/m^2$ with the cooling water velocity of 10 m/s. After thermal cycle experiments, a large number of microcracks appeared at the tungsten substrate due to large radial tensile stress on the flat mock-up. The defects would largely affect the heat transfer capability and the structure reliability of the mock-up. As for the arc mock-up, even though some microcracks were found at the interface of the regions, all microcracks with arc interface were divided into different arc-grooved zones, so the propagation of microcracks is difficult.

  • PDF

Survey on Radiotherpv Protocols for the Rectal Cancers Among the Korean Radiation Oncologists in 2002 for the Development of the Patterns of Care Study of Radiation Therapy (방사선치료 Patterns of Care Study 개발을 위한 2002년 한국 방사선종양학과 전문의들의 직장암 방사선치료 원칙 조사연구)

  • Kim, Jong-Hoon;Kim, Dae-Yong;Kim, Young-Ho;Kim, Woo-Chul;Kim, Chul-Yong;Sung, Jin-Shil;Son, Seung-Chang;Shin, Hyun-Su;An, Young-Chan;Oh, Do-Hum;Oh, One-Yong;Yu, Mi-Ryung;Yu, Hung-Jun
    • Radiation Oncology Journal
    • /
    • v.21 no.1
    • /
    • pp.44-65
    • /
    • 2003
  • Purpose : To conduct nationwide surgery on the principles In radiotherapy for rectal center, and develop the framework of a database of Korean Patterns of Care Study. Materials and Methods : A consensus committee was established to develop a tool for measuring the Patterns in radiotherapy Protocols for rectal cancer. The Panel was composed of radiation oncologists from 18 hospitals in Seoul Wetropolltan area. The committee developed a survey format to analyze radiation oncologist's treatment principles for rectal cancer. The survey items developed for measuring the treatment principles were composed of 1) 8 eliglblllty criteria, 2) 20 Items for staging work-ups and prognostic factors, 3) 7 Items for principles of combined surgery and chemotherapy, 4) 9 patient set-ups, 5) 19 determining radiation fields, 6) S radiotherapy treatment pians, 7) 4 physicalilaboratory examination to monitor a patient's condition during treatment, and 8) 10 follow-up evaluations. These items were sent to radiation oncoioglsts In charge of gastrolntestlnal malignancies in all hospitals (48 hospitals) In Korea to which 30 replies were received (63$\%$). Results : Most of the surrey Items were replied to without no major between the repliers, but with the fellowing items only 50$\%$ of repliers were in agreement : 1) Indications of preoperative radiation, 2) use of endorectal ultrasound, CT scan, and bone scan for staging work-ups, 3) principles of combining chemotherapy with radiotherapy, 4) use of contrast material for small bowel delineation during simulation, 5) determination of field margins, and 6) use of CEA and colonoscopy for follow-up evaluations. Conclusions : The Items where considerable disaggrement was shown among the radiation oncologists seemed to make no serious difference In the treatment outcome, but a practical and reasonable consensus should be reached by the committee, with logical processes of agreement. These Items can be used for a basic database for the Patterns of Care Study, which will survey the practical radiotherapy Patterns for rectal cancer in Korea.

Clinical Application of in Vivo Dosimetry System in Radiotherapy of Pelvis (골반부 방사선 치료 환자에서 in vivo 선량측정시스템의 임상적용)

  • Kim, Bo-Kyung;Chie, Eui-Kyu;Huh, Soon-Nyung;Lee, Hyoung-Koo;Ha, Sung-Whan
    • Journal of Radiation Protection and Research
    • /
    • v.27 no.1
    • /
    • pp.37-49
    • /
    • 2002
  • The accuracy of radiation dose delivery to target volume is one of the most important factors for good local control and less treatment complication. In vivo dosimetry is an essential QA procedure to confirm the radiation dose delivered to the patients. Transmission dose measurement is a useful method of in vivo dosimetry and it's advantages are non-invasiveness, simplicity and no additional efforts needed for dosimetry. In our department, in vivo dosimetry system using measurement of transmission dose was manufactured and algorithms for estimation of transmission dose were developed and tested with phantom in various conditions successfully. This system was applied in clinic to test stability, reproducibility and applicability to daily treatment and the accuracy of the algorithm. Transmission dose measurement was performed over three weeks. To test the reproducibility of this system, X-tay output was measured before daily treatment and then every hour during treatment time in reference condition(field size; $10 cm{\times} 10 cm$, 100 MU). Data of 11 patients whose pelvis were treated more than three times were analyzed. The reproducibility of the dosimetry system was acceptable with variations of measurement during each day and over 3 week period within ${\pm}2.0%$. On anterior- posterior and posterior fields, mean errors were between -5.20% and +2.20% without bone correction and between -0.62% and +3.32% with bone correction. On right and left lateral fields, mean errors were between -10.80% and +3.46% without bone correction and between -0.55% and +3.50% with bone correction. As the results, we could confirm the reproducibility and stability of our dosimetry system and its applicability in daily radiation treatment. We could also find that inhomogeneity correction for bone is essential and the estimated transmission doses are relatively accurate.

Development of an Aerodynamic Simulation for Studying Microclimate of Plant Canopy in Greenhouse - (2) Development of CFD Model to Study the Effect of Tomato Plants on Internal Climate of Greenhouse - (공기유동해석을 통한 온실내 식물군 미기상 분석기술 개발 - (2)온실내 대기환경에 미치는 작물의 영향 분석을 위한 CFD 모델개발 -)

  • Lee In-Bok;Yun Nam-Kyu;Boulard Thierry;Roy Jean Claude;Lee Sung-Hyoun;Kim Gyoeng-Won;Hong Se-Woon;Sung Si-Heung
    • Journal of Bio-Environment Control
    • /
    • v.15 no.4
    • /
    • pp.296-305
    • /
    • 2006
  • The heterogeneity of crop transpiration is important to clearly understand the microclimate mechanisms and to efficiently handle the water resource in greenhouses. A computational fluid dynamic program (Fluent CFD version 6.2) was developed to study the internal climate and crop transpiration distributions of greenhouses. Additionally, the global solar radiation model and a crop heat exchange model were programmed together. Those models programmed using $C^{++}$ software were connected to the CFD main module using the user define function (UDF) technology. For the developed CFD validity, a field experiment was conducted at a $17{\times}6 m^2$ plastic-covered mechanically ventilated single-span greenhouse located at Pusan in Korea. The CFD internal distributions of air temperature, relative humidity, and air velocity at 1m height were validated against the experimental results. The CFD computed results were in close agreement with the measured distributions of the air temperature, relative humidity, and air velocity along the greenhouse. The averaged errors of their CFD computed results were 2.2%,2.1%, and 7.7%, respectively.