• 제목/요약/키워드: Field simulation

검색결과 5,641건 처리시간 0.042초

PROBE FEEDING SIMULATION USING OVERLAPPING-GRID TECHNIQUE FOR FDTD

  • Min, Kyeong-Sik;Vu, Manh-Dat
    • 한국마린엔지니어링학회:학술대회논문집
    • /
    • 한국마린엔지니어링학회 2005년도 전기학술대회논문집
    • /
    • pp.442-447
    • /
    • 2005
  • This paper presents an application of overlapping-grid technique for probe feeding simulation. The overlapping grid technique is used to solve contour path problem. In this technique, field interpolation is very important to make communication between two coordinates. By applying overlapping-grid technique, error of contour path in probe feeding simulation is reduced.

  • PDF

EMC Simulation을 이용한 GaAs/AlGaAs 양자 우물 내 전자의 충돌 이온화율 (Impact Ionization Rates of Electron in GaAs/AlGaAs Qunantum Well Using EMC Simulation)

  • 윤기정;홍창희
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1994년도 추계학술대회 논문집
    • /
    • pp.221-225
    • /
    • 1994
  • We described the impact ionization rates of electron in GaAs/AlGaAs MQH(multi- quantum well) using EMC(ensenble Monte Carlo) simulation. Hot electron energy of injected into quantum well is increasing nearly liearly due to the applied electric field to the barrier of MQM inspite of various Al mole fraction in AlGaAs or barrier width. Impact ionization rates are decreasing exponentially by increasing Al mole fraction, and they have peak vague due to the barrier width.

Global MHD Simulation of the Earth's Magnetosphere Event on October, 1999

  • PARK KYUNG SUN;OGINO TATSUKI
    • 천문학회지
    • /
    • 제34권4호
    • /
    • pp.317-319
    • /
    • 2001
  • The response of the earth's magnetosphere to the variation of the solar wind parameters and Interplanetary magnetic field (IMF) has been stud}ed by using a high-resolution, three-dimension magnetohydrodynamic (MHD) simulation when the WIND data of velocity Vx, plasma density, dynamic pressure, By and Bz every 1 minute were used as input. Large electrojet and magnetic storm which occurred on October 21 and 22 are reproduced in the simulation (fig. 1). We have studied the energy transfer and tail reconnect ion in association with geomagnetic storms.

  • PDF

고출력 마이크로파 발생장치인 링형태의 세 개의 캐소드를 가전 버카터의 시뮤레이션 연구 (Simulation Study for the Vircator with three cathodes ring)

  • 이봉균
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1998년도 하계학술대회 논문집 E
    • /
    • pp.1850-1851
    • /
    • 1998
  • Using the "MAGIC" code, computer simulation is performed to design a cathode structure which provides a radial distribution of electron beam density matching the field distribution of the $TM_{05}$ mode. Thus, very narrow band $TM_{05}$ mode microwave radiation can be generated in an open end waveguide. The simulation results show that the vircator can indeed be operated at the selected frequency 10.2GHz with a very narrow bandwidth(${\Delta}{\omega}/{\omega}$ < 1%).

  • PDF

실내음향 예측을 위한 컴퓨터 프로그램 이용에 관한 연구 (A Study on the Utilization of Computer Program for the Prediction of Rom Acoustics)

  • 김선우;최형욱;한명호
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 1997년도 추계학술대회논문집; 한국과학기술회관; 6 Nov. 1997
    • /
    • pp.250-255
    • /
    • 1997
  • The computer simulation and mock-up test are recently applied to the practical design for the room acoustics to predict and evaluate its characteristics. In this paper, the sound field properties predicted and evaluated by the computer simulation were compared to the measured data. Comparison and analysis between simulation data and measured data were performed for the Reverberation Time, Sound Pressure Level at the various measuring positions and frequencies and Definition, Early Decay Time, Speech Transmission Index.

  • PDF

Intrusion of a Magnetic Field through the Overlying Field in the Solar Atmosphere Induced by Ballooning Instability

  • 전홍달;최광선
    • 천문학회보
    • /
    • 제35권1호
    • /
    • pp.26.2-26.2
    • /
    • 2010
  • It has been a puzzle in solar physics how a low-lying magnetic structure such as a solar prominence surrounded by a strongly line-tied overlying field sometimes intrudes through the latter and goes into eruption. A numerical simulation study of the solar coronal plasma reveals that a ballooning instability can explain this type of eruptive process. We consider an idealized situation with two flux ropes merging. When magnetic field lines from different flux ropes reconnect, a new field line connecting farther footpoints is generated. Since the field line length abruptly increases, the field line expands outward. If the plasma beta is low, this expansion takes place more or less evenly over the whole field line. If, on the other hand, the plasma beta is high enough somewhere in this field line, the outward expansion is not even, but is localized as in a bulging balloon. This ballooning section of the magnetic field penetrates out of the overlying field, and eventually the originally underlying field and the overlying field come to interchange their apex positions. This process may explain how a field structure that has stably been confined by an overlying field can occasionally show a localized eruptive behavior.

  • PDF

200kW 타워형 태양열발전시스템의 헬리오스타트 필드 운영 알고리즘 개발 (Development of Heliostat Field Operational Algorithm for 200kW Tower Type Solar Thermal Power Plant)

  • 박영칠
    • 한국태양에너지학회 논문집
    • /
    • 제34권5호
    • /
    • pp.33-41
    • /
    • 2014
  • Heliostat field in a tower type solar thermal power plant is the sun tracking mirror system which affects the overall efficiency of solar thermal power plant most significantly while consumes a large amount of energy to operate it. Thus optimal operation of it is very crucial for maximizing the energy collection and, at the same time, for minimizing the operating cost. Heliostat field operational algorithm is the logics to control the heliostat field efficiently so as to optimize the heliostat field optical efficiency and to protect the system from damage as well as to reduce the energy consumption required to operate the field. This work presents the heliostat field operational algorithm developed for the heliostat field of 200kW solar thermal power plant built in Daegu, Korea. We first review the structure of heliostat field control system proposed in the previous work to provide the conceptual framework of how the algorithm developed in this work could be implemented. Then the methodologies to operate the heliostat field properly and efficiently, by defining and explaining the various operation modes, are discussed. A simulation, showing the heat flux distribution collected by the heliostat field at the receiver, is used to show the usefulness of proposed heliostat field operational algorithm.

광전계 센서를 이용한 구형 Loop Antenna의 근접전계 특성 (Characteristic for the Near Field of Rectangle Loop Antenna using Optical Electric-Field Sensor)

  • 이주현;도쿠다마사미추;하덕호
    • 한국전자파학회논문지
    • /
    • 제14권3호
    • /
    • pp.217-225
    • /
    • 2003
  • 본 논문에서는 전파암실(8.5 m x 7 m x 7 m)에서 광전계센서를 이용한 Loop Antenna의 근접전계 분포특성을 파악하기 위해 시간 및 주파수 영역에 대하여 측정한 후 시뮬레이션 결과와 비교 분석하였다. 시뮬레이션은 MoM와 FDTD을 이용하여 각각 주파수 및 시간영역에 대하여 시뮬레이션 하였다. 그 결과 측정 과 시뮬레이션이 상당히 일치하였으며, 측정에 이용한 광전계 센서의 유효성을 확인하였다. 또한, 주파수 영역에 있어서 Loop Antenna의 수직 엘리멘트 근접에 광전계 센서를 각각 수직 과 수평편파로 한 경우 약 15 ㏈ 정도의 차이를 보였고 Loop Antenna의 수평 엘리멘트 보다 높은 곳에서는 신호레 벨의 별다른 차이가 없었다. 그리고, 시간영역에 있어서는 Loop Antenna의 수평 엘리멘트 보다 높은 곳에서 광전계센서를 수직편파로 한 경우의 수신펄스 모양은 부(-)의 방향으로 됨을 알 수 있었다.

터널굴착 시뮬레이션을 위한 터널굴착장비의 개발에 대한 연구 (A study of tunnelling equipment development in a model test)

  • 김상환
    • 한국터널지하공간학회 논문집
    • /
    • 제5권2호
    • /
    • pp.199-207
    • /
    • 2003
  • 지반공학적인 측면에서의 터널에 대한 모델링작업은 실질적인 터널공사시 야기되는 상세거동을 재현할수 있는 터널장비의 개발로 터널굴진과정을 실질적으로 묘사하는데 있다고 볼수 있다. 최신기계정보활용기술은 즉 시공과정 및 기계제어기술등을 실험실에서 재현할 수 있도록 하였다. 그러나, 이러한 기술 등은 중력장상태에서 사용되도록 개발되어지고, 1g 또는 원심장 (Centrifuge Field) 상태의 실험에서 주로 활용되고 있다. 이에 따라 본 논문은 터널링과정에 대한 씨뮬레이션기법과 실험실에서 활용되는 쉴드터널장비의 설계기법 및 개발에 대한 연구 결과를 수록하였다. 또한 개발된 장비의 정밀성과 신뢰성을 반복적인 실험을 통하여 검증하고, 개발된 장비를 이용하여 얻은 결과와 실질적인 현장자료와 비교분석하였다.

  • PDF

진공인터럽터 내부 End Shield형상과 갭거리에 따른 연면방전거동 (Behavior of Surface Flashover Depending on Shape and Gap Distance of End Shield in Vacuum Interrupter)

  • 윤재훈;임기조
    • 한국전기전자재료학회논문지
    • /
    • 제23권2호
    • /
    • pp.169-173
    • /
    • 2010
  • Because of power consumption increase, global warming, and limitation of installation, not only high reliability and interruption capability but also compact and light power apparatuses are needed. In this paper, E field calculation and experiment were processed to identify the influence of the shape of end shield and gap distance. It is expected that the results of FEM simulation and experiments could be the basic data to develop VI. the results of FEM simulation and experiments are as following. Firstly, maximum E fields were compared by means of finite element method as a function of the shape of end shield. 3 types of models were used to analyze maximum E field of each model and the influence of shape of shield could be identified. As a result, proposed L type shield could reduce the maximum E field by 20%. Secondly, the influence of the gap distance between end shields on E field was analyzed. As the gap distance become short the gap distance between inner walls of ceramic also become short. And the maximum E field concentrated on inner wall of ceramic finally increased. Thirdly, the experiment was conducted by fabricating each prototype. As a result, no creepage occurred in shieldless model. In other words, creepage occurred in the shield-installed models. And creepage inception voltages were different from each other because of the difference of maximum E field. Fourthly, The equation that shows relation between calculated E field and measured creepage inception voltage was proposed as a result of FEM analysis and experiment. It is concluded that when designing VI this equation could be important data to reduce time and cost by identifying indirectly the optimal gap distance and the shape of shield required to prevent creepage.