• 제목/요약/키워드: Field performance test

검색결과 2,048건 처리시간 0.025초

채널별 음장분포 분석을 통한 진단용 초음파 어레이 프로브의 평가방법에 관한 연구 (A Study of Testing Method for Diagnostic Ultrasonic Array Probe through Pattern Analysis of Acoustic-Fields with Probe Channel Division)

  • 유병철;최흥호;노시철;민해기;권장우
    • 대한의용생체공학회:의공학회지
    • /
    • 제27권5호
    • /
    • pp.229-236
    • /
    • 2006
  • The acoustic field analysis method is the superior calibration method for rectifying the ultrasonic probe sensitivity. This method also can be applied to evaluate the probe performance in clinical fields without numerical analysis and precise measurements. In this paper, we propose the method of acoustic field pattern analysis with probe channel division for the evaluation of diagnostic ultrasound probe characterization. In order to verify our purpose, we performed a set of experiments. We measured the acoustic-field pattern of the three inferiority probes by channel division to evaluate an acoustic field distribution and impulse response characteristics. By comparing the results of acoustic field measurement method with that of conventional method such as impulse response and live image test for linear array probes, it is demonstrated that the ultrasound field measurement method is more effective then conventional method in detection of defective elements.

5상 농형 유도전동기의 정수 추정 (Parameters Estimation of Five-phase Squirrel-Cage Induction Motor)

  • 김민회
    • 전기학회논문지P
    • /
    • 제61권4호
    • /
    • pp.199-205
    • /
    • 2012
  • This paper propose a improved parameter estimations of five-phase squirrel-cage induction motor(IM) for speed control system on field oriented control(FOC). In order to high performance control of ac the motors using a FOC and DTC(direct torque control) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, rotor position and speed estimation, and so on. We are suggest a estimation method of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental. There are results of stator winding test, no-load test, locked rotor test, and obtained equivalent circuits using manufactured experimental apparatus. For presenting the superior performance of the speed control system in adapted the parameters, experimental results are presented using a 32-bit fixed point TMS320F2812 DSP with 1.5[KW] IM.

자기유변탄성체의 마찰제어적용 연구 (Application Study of Magneto-Rheological Elastomer to Friction Control)

  • 연성룡;이득원;이광희;이철희;김철현;조원오
    • Tribology and Lubricants
    • /
    • 제28권3호
    • /
    • pp.107-111
    • /
    • 2012
  • In this study, application feasibility of Magneto-rheological elastomer to friction control is investigated to identify the reciprocating friction and wear performance in applied magnetic field. Friction and wear of MR elastomerare measured by reciprocating tester by controlling the magnetic field. In the case of applied magnetic field, the coefficient of friction increases as both load and velocity increase. For the case of no magnetic field, the value of coefficient of friction hardly changes during the test. The amount of destruction is measured through cross section images of MR elastomer after tests. The depths of destruction are compared for MR elastomer with or without magnetic field. The results show that the depth of destruction of MR elastomer with magnetic field is deeper than without magnetic field. Based on the obtained results, optimal braking and driving performance can be achieved by controlling the coefficient of friction of MR elastomer, which can be applied to various industrial applications such as driving systems of automobiles and robots.

재생혼합토(Tire Shred-Sandy Soil Mixture)로 조성된 도로성토구조물의 장기성능 (Long-term Performance of Highway Embankment Using Tire Shred-Sandy Soil Mixture)

  • 고태훈;황선근;윤성민;박희문;이성진
    • 한국지반환경공학회 논문집
    • /
    • 제10권5호
    • /
    • pp.41-47
    • /
    • 2009
  • 본 논문에서는 폐타이어 활용 재생혼합토(Tire Shred-Sandy Soil Mixture)로 조성된 도로성토구조물의 장기성능을 평가하고자 현장계측 및 현장시험을 수행하였다. 최대 크기 76mm의 폐타이어와 사질토를 50 : 50의 체적비로 혼합한 재생혼합토 성토구조물은 도로개통 후 침하, 변형, 온도측면에서 장기적으로 안정된 모습을 보였으며, 특히 FWD 시험결과, 기존 성토재료로 조성된 성토구간의 지지성능과 동등한 수준으로 설계수명을 만족하였다.

  • PDF

현장성능시험에 의한 터보냉동기의 정상상태모델 개발 (Steady-state Modelling of Centrigugal Chiller through On-Site Test)

  • 장영수;신영기;백영진;김영일
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2001년도 추계학술대회논문집B
    • /
    • pp.83-88
    • /
    • 2001
  • This paper presents modelling and analyzing method of centrifugal chiller which has a rated capacity of 200 RT(703 kW) through on-site performance test. Field data of chiller installed in the clean-room building of KIST have been collected, Simple models were developed for predicting the heat exchangers and system performances by regression of chiller operation data during 5 days in August. The models proposed here account for the effect of variations of cooling capacity, temperatures and flow rates of secondary fluids. The models are consistent with real performance data from June to September within ${\pm}5%$ error. The COP of centrifugal chiller are estimated under the standard rating conditions and reduced mass flow rate of chilled and cooling water.

  • PDF

낙하 충격 실험을 통한 자기유변탄성체의 충격 흡수 성능 평가 (The Evaluation of Shock Absorption Performance of Magneto-Rheological Elastomer Through the Drop Impact Test)

  • 정경식;이철희
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2013년도 추계학술대회 논문집
    • /
    • pp.92-93
    • /
    • 2013
  • In this study, Shock Absorption performance of Magneto-rheological elastomer(MRE) is identified through the drop impact test. Magneto-rheological materials are divided into two groups by MR fluid in fluid state and MR elastomer in solid state like rubber. The stiffness characteristics of Magneto-rheological material can be changed as magnetic field is applied. The impact loads in MR elastomer were measured under weight of impactor. Experiment results are shown through the experiments to confirm the effect of shock absorption of MR elastomer. Thus, the MR elastomer can be applied to shock absorber used in area that shock occurs.

  • PDF

다공 포트 연소기 후기 챔버의 유동 및 성능 특성 연구 (Post-chamber Flow and Performance of the Multi-port Combustor)

  • 소정수;김소라;송재천;이동훈;윤창진;문희장
    • 한국항공운항학회지
    • /
    • 제15권4호
    • /
    • pp.17-23
    • /
    • 2007
  • This paper describes the flow and performance characteristics inside the post-chamber of the multi-port hybrid rocket motor. Using the computational fluid dynamics (CFD) technique, the non reactive compressible flow fields in the downstream of the fuel grain was numerically calculated. The motor performance obtained from computational results were in agreement with that conducted by the ground motor firing test. Besides, the flow field characteristics inside the post-chamber were discussed under different port numbers (1 port and 3 ports) of the fuel grain. The flow pattern showed that the performance of multi-port hybrid rocket motor having three grain ports is higher than that of the single-port one due mainly to the difference of incoming mass flow rate irrespective to the pressure field.

  • PDF

소면적 PEM연료전지 성능개선 연구 (A Study on Performance Improvement in PEMFC)

  • 천광우;박창권;이호열;오병수
    • 한국수소및신에너지학회논문집
    • /
    • 제15권4호
    • /
    • pp.291-300
    • /
    • 2004
  • Performance of PEMFC is affected by many factors such as that of MEA, configuration of flow field, operating conditions, humidification, cooling and so on. In this study, in order to improve the performance of fuel cell, a small area fuel cell stack was made and its performance was tested under various operating conditions. Stack consists of 3 single PEM fuel cells. Channel is serpentine type and the active area of the electrode is $50cm^2$. The test results show that the peak power is 60W at $70^\circ{C}$ of stack temperature with humidification condition.

$SF_6$ 가스차단기의 소전류 차단성능 해석 (Analysis of Small Current Interruption Performance for $SF_6$ Gas Circuit Breaker)

  • 김홍규;송기동;정진교;오연호;박경엽
    • 대한전기학회논문지:전기기기및에너지변환시스템부문B
    • /
    • 제55권10호
    • /
    • pp.528-533
    • /
    • 2006
  • To analyze the small current interruption performance for the gas circuit breakers, the gas density and electric field intensity should be calculated. In this paper, the FVFLIC method is used for the gas flow analysis and the FEM for the electric field analysis. Then, the dielectric withstanding voltage is evaluated by the empirical formulation or Streamer theory. By comparing the calculated dielectric strength with the test result, it is found that both methods show good prediction capability for the small current interruption performance. Especially, when both methods predict the same interrupting performance, the prediction is in accordance with the experimental result.

고속철도 궤도의 곡선부 주행안전성 평가 (Study for Safety on the Curve in the High-speed Railway Track)

  • 서사범;이동호;구봉근
    • 한국철도학회논문집
    • /
    • 제8권4호
    • /
    • pp.354-360
    • /
    • 2005
  • The railway track and the substructures constructed in the field test section of Kyongbu High Speed Line are the structures for HSL, for the first time designed and constructed by domestic technical group. It is very important to verify the local design criteria and specifications for these structures and also to assure the recordings for vibration or deflection produced on the essential parts of the structures. The study to verify the high-speed railway track performance and to ensure the run in safety on the track in curved section during the KTX run. Finally, the conclusion are drawn as follows. The measuring values of the deflection effort of the rail and displacement for verifying the track performance in the field test section of Kyoungbu HSL satisfy the criteria of the foreign countries (Japan and Germany). The measured value for the wheel load and the presumed value show the consistent tendency. The wheel loads of the exterior and interior of the rails at the speed superior to 300km/h are measured same. Finally, the comparison between the theoretical value presented during the verification of the derailment to evaluate the safety of the train run at the time of the detailed design of the track and the measured value in the field shows that the correct design of track structure was applied.