• Title/Summary/Keyword: Field performance test

검색결과 2,048건 처리시간 0.03초

Fabrication and field performance test of a tractor-mounted 6-row cabbage collector

  • Han, Kwang-Min;Ali, Mohammod;Swe, Khine Myat;Islam, Sumaiya;Chung, Sun-Ok;Kim, Dae-Geon
    • 농업과학연구
    • /
    • 제48권1호
    • /
    • pp.141-149
    • /
    • 2021
  • The cultivation area for domestic cabbage increased by 26.3% from 10,968 ha in 2019 to 13,854 ha in 2020, and among leafy vegetables, the cabbage cultivation area was 62%, and production was 78.9%. Demand for field crop production of cabbage, which has a relatively high-income level compared to rice farming, is increasing, and mechanization of the field operation is urgently needed due to the insufficient development of related farming machinery. In this study, a prototype fabrication and performance test of a tractor-attached cabbage collector was carried out. The transport section was divided into two parts, one for the feeding and transportation and the other for the screening and packaging to selectively collect cabbages in bulk bags or boxes. The length of the primary collecting conveyor was designed to meet the field conditions of the Korean cabbage cultivation standards so that six cultivation rows could be worked simultaneously. Power was controlled by a hydraulic transmission line of the tractor and was easily mounted onto the 3-point hitch links behind the tractor. When the performance was evaluated, the transfer rate, loss rate, damage rate, and work performance were 100, 0, 1.2%, and 1.9 h·10 a-1. Final improvement and commercialization of the prototype would considerably contribute to the mechanization of harvesting cabbage, the main ingredient of Kimchi.

상사성을 이용한 model 사류펌프의 성능 예측 (Performance Prediction of Model Mixed Flow Pump Using Similarity)

  • 이덕형
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 2005년도 연구개발 발표회 논문집
    • /
    • pp.393-400
    • /
    • 2005
  • As one of the useful and powerful methods for designing the optimum pump is using model pump, it is based on the similarity characteristics of turbomachinery. With this theory, we can predict the performance of various pumps. In fact we have performed huge pumps using this, the experimental results were to be sufficient to prove the similarity characteristics. In this study, we predicted the performance of the huge proto-type pump that cannot be installed and made a test. First of all, we had calculated the model ratio between proto-type and model. There were two ways to estimate the performance. One was the application of CFD code, and the other way was model field test. So We selected both of them to guarantee the dependable data and evaluated each other.

  • PDF

자동요금징수 시스템(ETCS)의 통신방식별 성능평가 결과 분석 (Field Test Analysis of Electronic Toll Collection System, Hi-Pass)

  • 조용성;배명환;오원일;이승환
    • 한국ITS학회 논문지
    • /
    • 제3권2호
    • /
    • pp.41-53
    • /
    • 2004
  • 본 연구는 국내 유료도로에 적용될 ETCS의 방식을 결정하기 위해 ETCS 현장성능평가에 참여한 6개 업체의 현장성능 평가 과정을 소개하고 이에 대한 평가결과를 분석한 것이다 현장성능평가에 참여한 업체의 주요 통신방식은 능동형 RF(전파)방식과 IR(광파)방식의 ETC 시스템이다. 본 연구에서는 업체별 통신방식과 시스템을 비교$\cdot$분석하고 시스템 구성과 기본성능을 확인한 후, 최종적으로 현장성능시험의 시험항목별 시험내용과 평가결과를 분석하였다. 현장성능평가 분석결과, 현장성능시험에 참여한 6개 업체 가운데 IR방식 1개 업체와 RF방식 2개 업체는 평가기준을 만족하고 나머지 3개 업체는 평가기준을 통과하지 못했지만, 전반적으로 볼 때, 그동안의 많은 시험과 개발과정을 거쳐 안정화가 되어 가고 있는 것으로 여겨진다. 본 현장시험에 사용한 성능평가방법은 현재 고속도로를 이용하는 또는, 하이패스에 이용되는 패턴을 충분히 고려하였지만, 발생될 수 있는 여러 경우에 대해 한국도로공사 자체기준으로 시험방법과 시험횟수를 정하였기 때문에 이에 대한논란의 여지는 있을 수 있다 따라서, 실제 고속도로상에서 발생될 수 있는 운전자의 행태나 도로 운영 방법 등 차량운행실태 등을 고려한 현장성능 시험 표준방법론의 개발이 필요한 것으로 판단된다.

  • PDF

묵밭에서 교란처리구배에 따른 중간교란가설의 검증 (Test of Intermediate Disturbance Hypothesis by Experimental disturbance Gradient in Old-Field Plant Community)

  • 이규송;김준호
    • The Korean Journal of Ecology
    • /
    • 제21권3호
    • /
    • pp.233-241
    • /
    • 1998
  • In order to test of intermediate disturbance hypothesis that an intermediate level of disturbance maximize biodiversity and to elucidate the effect of disturbance during the early old-field succession, the response of plant community along an experimental disturbance gradient was investigated in a five-year old-field. Response of plant community along an experimental disturbance gradient was connected with light condition because artificial disturbance gradient had been treat by clipping of plants and removing of litter. Artificial disturbance in five-year old-field plant community retarded rate of succession by increasing invasion and performance of the earlier successional species in the initial and middle stage of disturbance treatment. The species richness in the blocks of intermediate disturbance level showed the peak in early and mid-summer. This result did correspond with the prediction of intermediate disturbance hypothesis.

  • PDF

스폴링이 발생한 콘크리트 포장의 내구성 영향인자 조사를 위한 실험적 연구 (Experimental Study to Investigate the Factors Affecting Durability of Spalled Cement Concrete Pavements)

  • 유태석;류성우;김진철
    • 한국도로학회논문집
    • /
    • 제20권2호
    • /
    • pp.27-34
    • /
    • 2018
  • PURPOSES : It is necessary to prevent premature failure of concrete pavements caused by durability problems. The purpose of this study was to find factors affecting the durability of concrete pavements, and suggest improvement methods for existing concrete mix design. METHODS : Factors influencing durability were derived from laboratory test data for common field failure conditions and main properties of concrete cores taken from the field. The improvement of concrete properties was investigated by evaluating the performance of existing and proposed mix proportion designs and curing methods. RESULTS : The compressive strength and the absorbing performance of the low Blaine cement and the high-strength mixture were better than those of the Type I cement. Wet curing showed better compressive strength, elastic modulus, coefficient of thermal expansion, and absorption performance than air curing or compound curing. As a result of comparing concrete cores collected in the field, the sections with good durability showed good performance in terms of resistance to chloride ion penetration, absorption, and initial absorption rate. CONCLUSIONS : The absorption performance was considered as a possible foactor affecting durability of cement concrete pavements as a result of field core tests. In order to improve the durability of the pavement concrete, it is necessary to improve the existing mixtures and curing methods.

Field monitoring of wind effects on a super-tall building during typhoons

  • Zhi, Lunhai;Li, Q.S.;Wu, J.R.;Li, Z.N.
    • Wind and Structures
    • /
    • 제14권3호
    • /
    • pp.253-283
    • /
    • 2011
  • This paper presents the field measurement results of wind effects on a super-tall building (CITIC Plaza, 391 m high) located in Guangzhou. The field data such as wind speed, wind direction and acceleration responses were simultaneously and continuously recorded from the tall building by a wind and vibration monitoring system during two typhoons. The typhoon-generated wind characteristics including turbulence intensity, gust factor, peak factor, turbulence integral length scale and power spectral density of fluctuating wind speed were presented and discussed. The dynamic characteristics of the tall building were determined based on the field measurements and compared with those calculated from a 3D finite element model of the building. The measured natural frequencies of the two fundamental sway modes of the building were found to be larger than those calculated. The damping ratios of the building were evaluated by the random decrement technique, which demonstrated amplitude-dependent characteristics. The field measured acceleration responses were compared with wind tunnel test results, which were found to be consistent with the model test data. Finally, the serviceability performance of the super-tall building was assessed based on the field measurement results.

Pressure equalization of rainscreen facades: Analysis of the field data in the frequency domain

  • Kumar, K. Suresh;Wisse, J.A.
    • Wind and Structures
    • /
    • 제4권2호
    • /
    • pp.101-118
    • /
    • 2001
  • This paper reports the field measurements concerning pressure equalization of rainscreen facades carried out at the Technical University of Eindhoven (TUE) in the Netherlands. The field facility including the details of test panel, meteorological tower, instrumentation, data collection and analysis is presented. Results of investigations into cavity response for various leakage and venting configurations are discussed. Frequency domain techniques have been utilized to show the influence of wind as well as facade characteristics on the pressure equalization performance. Further, this paper presents an early attempt to synthesize the experimental results into existing building codes.

토양 조건에 따른 농업용 트랙터의 견인 성능 분석 (Analysis of Traction Performance for Agricultural Tractor According to Soil Condition)

  • 이남규;김용주;백승민;문석표;박성운;최영수;최창현
    • 드라이브 ㆍ 컨트롤
    • /
    • 제17권4호
    • /
    • pp.133-140
    • /
    • 2020
  • Traction performance of a tractor varies depending on soil conditions. Sinkage and slip of the driving wheel for tractor frequently occur in a reclaimed land. The objective of this study was to develop a tractor suitable for a reclaimed land. Traction performance was evaluated according to soil conditions of reclaimed land and paddy field. Field experiments were conducted at two test sites (Fields A: paddy field; and Field B: reclaimed land). The tractor load measurement system was composed of an axle rotation speed sensor, a torque meter, a six-component load cell, GPS, and a DAQ (Data Acquisition System). Soil properties including soil texture, water content, cone index, and electrical conductivity (EC) were measured. Referring to previous researches, the tractor traveling speed was set to B3 (7.05 km/h), which was frequently used in ridge plow tillage. Soil moisture contents were 33.2% and 48.6% in fields A and B, respectively. Cone index was 2.1 times higher in field A than in field B. When working in the reclaimed land, slip ratios were about 10.5% and 33.1% for fields A and B, respectively. The engine load was used almost 100% of all tractors under the two field conditions. Traction powers were 31.9 kW and 24.2 kW for fields A and B, respectively. Tractive efficiencies were 83.3% and 54.4% for fields A and B, respectively. As soil moisture increased by 16.4%, the tractive efficiency was lowered by about 28.9%. Traction performance of tractor was significantly different according to soil conditions of fields A and B. Therefore, it is necessary to improve the traction performance of tractor for smooth operations in all soil conditions including a reclaimed land by reflecting data of this study.

Influence of Global Competitive Capability on Global Performance of Distribution Industry in South Korea

  • KIM, Boine;KIM, Byoung-Goo
    • 유통과학연구
    • /
    • 제19권12호
    • /
    • pp.83-89
    • /
    • 2021
  • Purpose: Purpose of this study is to empirically analyze influence of global competitive capability on global performance of distribution industry in South Korea. Also based on the empirical results, give managerial implication to distribution industry and contribute to academies of management. Research design, data and methodology: This study focuses on relationship analysis between global competitive capability and global performance. This study measured global competitive capability with three concepts; human capability, network capability and product/service capability. And measured global performance with export performance. To empirically analyze relationship between variables, this study used 2,316 data of GCL Test by KOTRA and Kdata. This study used SPSS26 and analyzed frequency, reliability, correlation and stepwise regression analysis. Results: Result shows that, in control variable, business period and business field give significant positive influence on export performance. Among antecedents, human capability and network capability give significant positive influence on export performance. However, product/goods/service was not significant. Due to significant influence of business field which is categorical variable. This study additionally analyze relationship by business field group to confirm whether relationship differ by group or similar. Conclusions: Based on the results, this study try to give implication to distribution industry management and contribute to academic.

고온 초전도 케이블 시스템 설치 밀 운전을 위한 연구 (Research for Installation and Operation of High Temperature Superconducting Cable System)

  • 최형식;손송호;황시돌
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 A
    • /
    • pp.653-657
    • /
    • 2005
  • The commercial contract was made firstly in the world for one set of high temperature superconducting(HTS) cable system between buyer, Korea Electric Power Research Institute and seller, Sumitomo Electric Industries, Ltd. in August 2004. After fabrication, test and examination, the HTS cable system will be installed at the KEPRI's test field in Gochang, Jeonbuk province from the time of July 2005. KEPRI is preparing measurement and test facilities for field test of the HTS cable system and carrying out researches into the design and construction of superconducting cable test building, evaluation of cooling performance, measurement of AC loss, analysis of the quench phenomena due to excess current and means of linking the HTS cable system to the existing electric power supplying system. The constitution of, the method to install and the plan of test operation of the HTS cable system will be presented in this paper.

  • PDF