• 제목/요약/키워드: Field measurement

검색결과 5,060건 처리시간 0.036초

비자기차폐환경에서 미세 자기장 측정을 위한 고온초전도 gradiometer 시스템의 개발 (Development of a HTS SQUID gradiometer system for the measurement of very weak magnetic field in an unshielded environment)

  • 김인선;김진목;박용기
    • 한국초전도학회:학술대회논문집
    • /
    • 한국초전도학회 2000년도 High Temperature Superconductivity Vol.X
    • /
    • pp.151-154
    • /
    • 2000
  • We have developed a YBCO SQUID gradiometer system for the measurement of a very weak magnetic field in an unshielded environment. The system consists of a SQUID gradiometer sensor, low noise pre-amp, and FLL(fluxlocked loop) control electronics. The gradiometer sensors have been fabricated on STO bicrystal substrates, and exhibit a magnetic noise of 300 fT/${\surd}$ Hz/cm at 100 Hz. The overall magnetic field noise of the SQUID gradiometer system was about 10 pT/${\surd}$ Hz/cm at 10 Hz without any magnetic shield. The system demonstrated a high stability for a long time, and real-time measurement resolution ${\le}$ 100 pT/cm in the unshielded environments.

  • PDF

광대역 교류 자기센서 특성 시험장치 설계에 관한 연구 (A Study on the System Design for Measuring the Property of Broadband AC Magnetic Sensors)

  • 정현주;양창섭;정우진
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2015년도 제46회 하계학술대회
    • /
    • pp.685-686
    • /
    • 2015
  • This paper describes design results of the measurement system to test the properties of broadband AC magnetic field sensors used in weapon system. This measurement system consists of 3-axis helmholtz coil, signal generator, signal amplifier, sensor data acquisition unit and measurement & analysis controller including the operating software. This system is able to measure various properties of AC magnetic field sensor such as sensitivity, linearity and dynamic response in the frequency of 1 Hz to 10 kHz. The performance of this system was verified by measuring and analyzing the property of a MAG 639, standard magnetic field sensor of bartington instruments, with this developed system.

  • PDF

인광입자(Sr,Mg)2SiO4:Eu2+를 이용한 액체의 온도장 측정에 관한 연구 (Study on Temperature Field Measurement of Fluid using Phophor Particle (Sr,Mg)2SiO4:Eu2+)

  • 송동진;이현창
    • 한국가시화정보학회지
    • /
    • 제17권3호
    • /
    • pp.59-65
    • /
    • 2019
  • Phosphor particles ((Sr,Mg)2 SiO4:Eu2+ were suspended in deionized water in quartz cuvette and used for measuring liquid temperature field by using two-color-ratio method. In the temperature range of 23~77℃, it showed the relative error from 2.4% to 4% and the temperature sensitivity of 0.65 %/℃ at 30℃ and 0.95 %/℃ at 77 ℃. This performance is comparable to measurement techniques using thermographic liquid crystal or laser induced fluorescence or other thermographic phosphor particle. Among investigated potential error sources, the particle number density affected the intensity ratio and the temperature, but the effect of laser fluence was not evident.

배치 플랜트를 위한 통합 제어 시스템 개발 (Development of the Integrated Control System for the Batch Plant in Field)

  • 김정숙
    • 한국전자통신학회논문지
    • /
    • 제12권6호
    • /
    • pp.1081-1086
    • /
    • 2017
  • 배치 플랜트 현장에서 사용되는 최상의 품질 콘크리트 제작을 위해 모래, 자갈, 시멘트, 물 및 강섬유 등의 주배합 비율을 최적으로 조절하기 위한 다양한 측정과 제어 장치가 필요하다. 현재는 저울, 인디게이터 및 PLC 등의 부품으로 구성되어 있다. 따라서 작업 초보자가 사용하기에는 어려움이 있다. 이에 본 논문에서는 모든 기능이 하나로 통합되게 PCB 기판을 사용한 하드웨어와 이를 제어하는 소프트웨어를 탑재한 비전문가도 사용하기 편리한 통합 제어 시스템을 개발하였다.

경년 열화에 따른 변압기 절연물의 회복전압 특성 (The Characteristics of RVM by Accelerated Aging in Insulating Materials of the Transformer)

  • 강석영;한상옥;김재훈;김주한;이세현
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 전기설비
    • /
    • pp.73-75
    • /
    • 2005
  • In present measurement of moisture contents is used as one of method for estimating degradation of transformer. Most of people use Karl-Fischer titration method for detection moisture contents but this measurement is inconvenient method because we must analyze transformer oil-paper after dismounting transformer and sampling in field. Therefore we don't directly investigate them in field. In this paper we will introduce Recovery Voltage Method(RVM) that is new method for estimating measurement in field though dismounting facility. For measure of moisture contents using RVM in accordance with accelerated thermal aging we have made experimental test cell and aged at a temperature up to 140$^{\circ}C$ for 300 hours. And we have been measured at intervals of 100 hours using RVM 5462 made in fetter company.

  • PDF

Establishment of strain measurement system for evaluation of strain effect in HTS tapes under magnetic field

  • Dedicatoria, Marlon J.;Shin, Hyung-Seop
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제13권4호
    • /
    • pp.14-17
    • /
    • 2011
  • The evaluation of the electromechanical properties of HTS CC tapes is one of the foremost procedures to be done to ensure the applicability of superconducting wires to electric devices. A precise measurement of the stress and strain is important in deriving the mechanical properties under operating environment. Up to now, there is no standard test method yet for the electromechanical property evaluation of HTS tapes under self field and external magnetic field although there are already reports on the different devices used to evaluate these properties. Strain can be measured by adopting a strain gauge or a high resolution double extensometer. In this study, strain effect on $I_c$ in HTS CC tapes under magnetic fields was evaluated. Comparison of advantages and setback of strain measuring devices were discussed. In addition, a dual strain measurement system using both the SG and extensometer may be practical to lessen the burden in case one of the measuring devices does not work well.

페블 베드 타입 고온 가스 냉각 원자로 내부 유동장 측정 (Measurement of Flow Field in the Pebble Bed Type High Temperature Gas-cooled Reactor)

  • 이사야;이재영
    • 대한기계학회:학술대회논문집
    • /
    • 대한기계학회 2008년도 추계학술대회B
    • /
    • pp.2088-2093
    • /
    • 2008
  • In this study, flow field measurement of the Pebble Bed Reactor(PBR) for the High Temperature Gas-cooled Reactor(HTGR) was performed. Large number of pebbles in the core of PBR provides complicated flow channel. Due to the complicated geometries, numerical analysis has been intensively made rather than experimental observation. However, the justification of computational simulation by the experimental study is crucial to develop solid analysis of design method. In the present study, a wind tunnel installed with pebbles stacked was constructed and equipped with the Particle Image Velocimetry(PIV). We designed the system scaled up to realize the room temperature condition according to the similarity. The PIV observation gave us stagnation points, low speed region so that the suspected high temperature region can be identified. With the further supplementary experimental works, the present system may produce valuable data to justify the Computational Fluid Dynamics(CFD) simulation method.

  • PDF

입주전 신축공동주택의 봄철 TVOC, HCHO농도 실태조사에 관한 연구 (A study on the field measurement of the TVOC and HCHO concentration in the newly constructed apartment houses in spring seasons)

  • 최승혁;김건우;이종식;박진철;김신도
    • 대한설비공학회:학술대회논문집
    • /
    • 대한설비공학회 2007년도 동계학술발표대회 논문집
    • /
    • pp.126-131
    • /
    • 2007
  • This study aims to present the fundamental strategies for improving the Indoor Air Quality(IAQ) in newly-constructed apartment buildings. To investigate the concentration of indoor air pollutants such as HCHO and VOCs and the field measurement were conducted. According to the field measurement of 60 new houses in spring season, the concentration of HCHO in about 20% were higher the IAQ standards.

  • PDF

PIV/LIF에 의한 교반혼합기 유동의 난류 속도/농도장 측정 및 POD해석 (Simultaneous Measurement of Velocity and Concentration Field in a Stirred Mixer Using PIV/LIF Techniqueut and POD Analysis)

  • 정은호;윤상열;김경천
    • 한국가시화정보학회:학술대회논문집
    • /
    • 한국가시화정보학회 2002년도 추계학술대회 논문집
    • /
    • pp.101-104
    • /
    • 2002
  • Simultaneous measurement of turbulent velocity and concentration field in a stirred mixer tank is carried out by using PIV/LIF technique. Instantaneous velocity fields are measured by a $1K\times1K$ CCD camera adopting the frame straddle method while the concentration fields are obtained by measuring the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. It is found that the general features of the mixing pattern are quite dependent on the local flow characteristics during the rapid decay of mean concentration. However, the small scale mixing seems to be independent on the local turbulent velocity fluctuation.

  • PDF

Investigation of Typhoon Wind Speed Records on Top of a Group of Buildings

  • Liu, Min;Hui, Yi;Li, Zhengnong;Yuan, Ding
    • 국제초고층학회논문집
    • /
    • 제8권4호
    • /
    • pp.313-324
    • /
    • 2019
  • This paper presents the analysis of wind speeds data measured on top of three neighboring high-rise buildings close to a beach in Xiamen city, China, during Typhoon "Usagi" 2013. Wind tunnel simulation was carried out to validate the field measurement results. Turbulence intensity, turbulence integral scale, power spectrum and cross correlation of recorded wind speed were studied in details. The low frequency trend component of the typhoon speed was also discussed. The field measurement results show turbulence intensity has strong dependence to the wind speed, upwind terrain and even the relative location to the Typhoon center. The low frequency fluctuation could severely affect the characteristics of wind. Cross correlation of the measured wind speeds on different buildings also showed some dependence on the upwind terrain roughness. After typhoon made landfall, the spatial correlation of wind speeds became weak with the coherence attenuating quickly in frequency domain.