• 제목/요약/키워드: Field dependence

검색결과 955건 처리시간 0.037초

분극전계가 모포트로픽 상경계 부근의 PZT 세라믹스의 공진주파수의 온도의존성에 미치는 영향 (The Effect of Poling Strength on Temperature Dependence of Resonance Frequency of PZT Ceramics Near the Morphotropic Phase Boundary)

  • 양정보;양완석;이개명
    • 전기학회논문지
    • /
    • 제57권7호
    • /
    • pp.1213-1217
    • /
    • 2008
  • Poling is an important process in fabricating PZT ceramic devices such as filters and resonators and activates piezoelectricity to sintered PZT ceramics. Tolerance of the operating frequency of these devices is tightly required in applications. And a factor to attribute the tolerance is the temperature dependence of the resonance frequency of PZT ceramics. In this paper the relationship of poling strength and temperature dependence of resonance frequency of PZT specimens was studied. The $Pb(Zr_{0.53}Ti_{0.47})O_3$ ceramics were fabricated and the poling strengths were chosen to be 0.5, 1.5, 2.5 and 3.5 [kV/mm]. The dielectric constant of the specimen poled in poling strength 0.5 [kV/mm] was less than that of unpoled specimen and the specimen poled in higher electric field had the higher dielectric constant. (002) peak in X-ray diffraction patterns of the specimens increased as poling strength increased. And the change of resonance frequency of the specimens according to the variation of temperature was measured. Resonance frequency of all specimens increased as the temperature increased. The specimen poled in higher electric field had the smaller positive temperature coefficient of resonance frequency. The effect that temperature coefficient of resonance frequency becomes smaller is obtained when Zr mole in PZT composition equation increase. Controlling the poling strength is believed to be a method to adjust the temperature stability of resonance frequency of the PZT ceramic devices.

Angular dependence of critical current of SmBCO coated conductor fabricated by co-evaporation method

  • Kim, Ho-Sup;Ha, Hong-Soo;Oh, Sang-Soo;Song, Kyu-Jeong;Ko, Rock-Kil;Ha, Dong-Woo;Kim, Tae-Hyung;Youm, Do-Jun;Lee, Nam-Jin;Moon, Seung-Hyun;Yoo, Sang-Im;Park, Chan
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제10권2호
    • /
    • pp.16-19
    • /
    • 2008
  • Angular dependence of critical current density of SmBCO coated conductor fabricated by co-evaporation method was investigated. For comparison, three samples were fabricated by a co-evaporation method and one sample was fabricated by a pulsed laser deposition process. The deposition system, named EDDC (Evaporation using Drum in Dual Chambers), is a batch type co-evaporation system, which is composed of reaction chamber and evaporation chamber. The normalized critical current density ratio ($I_c/I_c$(H//ab-plane)) of EDDC-SmBCO samples was found to be higher than that of PLD-YBCO sample in the whole range of angle. While the EDDC-SmBCO samples evidently had a peak at the angle of H//c-axis in the plot of the angular dependence of critical current, the normalized critical current of PLD-YBCO sample decreased monotonically without any peak as angle increased. The field dependence of critical current under the magnetic field parallel to the normal direction of those samples showed similar aspect in the range of $0\;G{\sim}5000\;G$.

Measurements of the Diamagnetic Susceptibility of NaCl Aqueous Solution

  • Lee, Seung-Hwan
    • 한국항해항만학회지
    • /
    • 제27권6호
    • /
    • pp.669-675
    • /
    • 2003
  • Using a SQUID magnetometer, the diamagnetic susceptibility of NaCl aqueous solution was measured with high accuracy in a magnetic field of up to 6 Tat 25$\pm0.05^{\circ}C$. The NaCl concentrations adopted in this experiment were 0 (water), 7.5, 15, 23, 26.2, 26.6 and 100% (crystal) with the concentration error of $\pm$0.04%. Experimental data was compared with the calculated value of susceptibility derived from dependence of the vapor pressure on NaCl concentration As a result, our measured value was almost in accordance with the calculated value. It was found that the diamagnetic susceptibility shows a decrease of approximately 10% within the saturated concentration (26.2%) and that the susceptibility is one of the effective cause for the concentration dependence in the gas-liquid interface deformation of the NaCl solution.

PARAMETER DEPENDENCE OF SMOOTH STABLE MANIFOLDS

  • Barreira, Luis;Valls, Claudia
    • 대한수학회지
    • /
    • 제56권3호
    • /
    • pp.825-855
    • /
    • 2019
  • We establish the existence of $C^1$ stable invariant manifolds for differential equations $u^{\prime}=A(t)u+f(t,u,{\lambda})$ obtained from sufficiently small $C^1$ perturbations of a nonuniform exponential dichotomy. Since any linear equation with nonzero Lyapunov exponents has a nonuniform exponential dichotomy, this is a very general assumption. We also establish the $C^1$ dependence of the stable manifolds on the parameter ${\lambda}$. We emphasize that our results are optimal, in the sense that the invariant manifolds are as regular as the vector field. We use the fiber contraction principle to establish the smoothness of the invariant manifolds. In addition, we can also consider linear perturbations, and thus our results can be readily applied to the robustness problem of nonuniform exponential dichotomies.

Examination of Frequency Dependence of Iron Loss in Magnetic Field Analysis

  • Masato Enokizono;Yuji Fujita
    • KIEE International Transaction on Electrical Machinery and Energy Conversion Systems
    • /
    • 제11B권3호
    • /
    • pp.59-63
    • /
    • 2001
  • This paper presents a new modeling of the two dimensional magnetic property in soft magnetic materials for the magnetic field computations. In this modeling an approximate treatment is introduced to expand the applicable exciting frequency range. The result shows that the new modeling presented here is very useful in simplicity of magnetic field analysis.

Rheology of Hollow Polyaniline Gutarate Suspension Under DC Electric Field

  • Choi, Ung-Su
    • KSTLE International Journal
    • /
    • 제9권1_2호
    • /
    • pp.36-38
    • /
    • 2008
  • The electrical and rheological behavior of the hollow polyaniline glutarate suspension in silicone oil was investigated. Hollow polyaniline glutarate suspension showed a typical ER response (Bingham flow behavior) under a DC electric field. The shear stress for the suspension exhibited the dependence with a factor equals to 0.95 power on the electric field. The experimental results for the hollow polyaniline glutarate suspension behaved as an ER fluid.

External Magnetic Field Influence on Exchange Coupling Oscillations in Ultrathin Fe/Au/Tb Film Structures

  • Pogoryelov, Ye.
    • Journal of Magnetics
    • /
    • 제9권4호
    • /
    • pp.97-100
    • /
    • 2004
  • In the present work exchange coupling between ultrathin Fe ($8{\AA}$) and Tb ($12{\AA}$) layers separated by Au spacer of varied thickness ($3-20{\AA}$) was studied. Anomalous Hall effect measurements showed weakly damped oscillating dependence of the Hall conductivity as a function of Au spacer thickness. Disagreement of the observed damping with the RKKY model of interlayer exchange coupling was explained by the influence of external magnetic field on the behaviour of exchange coupling oscillations. It was confirmed by Hall-like effect measurements at zero applied magnetic field and also illustrated by corresponding estimations.

Wedge Factor의 임상적 응용 (Clinical Application of Wedge Factor)

  • 최동락;안용찬;허승재
    • Radiation Oncology Journal
    • /
    • 제13권3호
    • /
    • pp.291-296
    • /
    • 1995
  • 목적 : 환자에 투여될 선량계산시 사용되는 wedge factor는 조사면과 깊이에 대한 의존성은 무시되고 에너지 및 wedge angle에 따라 측정하는 것이 일반적이다. 본 연구에서는 wedge factor의 조사면과 깊이에 따른 의존성을 체계적으로 조사함으로써 보다 합리적인 선량계산을 도모하고자 한다. 방법 : 4-, 6-, 그리고 10-MV X 선을 이용하여 각각의 wedge angle에 따라서 $5{\times}5\;cm^2$부터 $20{\times}20\;cm^2$ 까지의 조사면에 대해서 여러 깊이에서 측정하였으며 측정된 값을 열린 조사면에서의 측정값으로 나누어 줌으로써 wedge factor가 결정되었다. 이 때 사용된 가속기는 본원이 보유하고 있는 CLINAC 600C 와 2100C 이며 사용된 에너지는 6- 그리고 10-MV X 선을 사용하였다. 측정기가 빔의 중심에 정확히 놓여졌는지를 확인하기 위하여 여러 콜리메이터 각도에서 측정하였다. 결과 : 각 측정값의 재연성에 관한 표준편차는 $0.3\;%$ 이내였으며 각각의 에너지에 대해 깊이에 따라 측정된 wedge factor의 의존성은 저에너지로 갈수록 커지는 경향을 보였다. 특히 4-, 6- X 선의 경우 wedge angle이 $45^{\circ}$ 이상일 때 깊이에 따른 wedge factor의 변화량은 $5\%$ 이상 차이가 남을 알 수 있었다. 반면에 wedge factor의 조사면에 대한 의존성은 거의 나타나지 않았다. 결론 : 측정을 통하여 wedge factor는 조사면에 대해서는 거의 무관하나 깊이에 따른 의존성이 비교적 크게 나타남을 알 수 있었다. 따라서 선량계산시 wedge factor를 합리적으로 평가하기 위해서는 평균값을 나타내는 깊이에서 측정된 값을 사용하거나 깊이에 따라서 wedge factor를 달리 적용시켜야 한다. 본 실험의 결과, 각 wedge filter에 대해 단일 wedge factor를 사용하고자 하면 조사면 $10cm{\times}10cm$, 깊이 10cm에서 측정된 값을 쓰는 것이 가장 합리적임을 알 수 있었다.

  • PDF