• Title/Summary/Keyword: Field correction

Search Result 739, Processing Time 0.026 seconds

Availability Analysis of SRAM-Based FPGAs under the protection of SEM Controller (SEM Controller에 의해 보호되는 SRAM 기반 FPGA의 가용성 분석)

  • Ryu, Sang-Moon
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.21 no.3
    • /
    • pp.601-606
    • /
    • 2017
  • SRAM-based FPGAs mainly used to develop and implement high-performance circuits have SRAM-type configuration memory. Soft errors in memory devices are the main threat from a reliability point of view. Soft errors occurring in the configuration memory of FPGAs cause FPGAs to malfunction. SEM(Soft Error Mitigation) Controllers offered by Xilinx can mitigate the influence of soft errors in configuration memory. SEM Controllers use ECC(Error Correction Code) and CRC(Cyclic Redundancy Code) which are placed around the configuration memory to detect and correct the errors. The correction is done through a partial reconfiguration process. This paper presents the availability analysis of SRAM-based FPGAs against soft errors under the protection of SEM Controllers. Availability functions were derived and compared according to the correction capability of SEM Controllers of several different families of FPGAs. The result may help select an SRAM-based FPGA part and estimate the availability of FPGAs running in an environment where soft errors occur.

Uncertainty Analysis of Quantitative Radar Rainfall Estimation Using the Maximum Entropy (Maximum Entropy를 이용한 정량적 레이더 강우추정 불확실성 분석)

  • Lee, Jae-Kyoung
    • Atmosphere
    • /
    • v.25 no.3
    • /
    • pp.511-520
    • /
    • 2015
  • Existing studies on radar rainfall uncertainties were performed to reduce the uncertainty for each stage by using bias correction during the quantitative radar rainfall estimation process. However, the studies do not provide quantitative comparison with the uncertainties for all stages. Consequently, this study proposes a suitable approach that can quantify the uncertainties at each stage of the quantitative radar rainfall estimation process. First, the new approach can present initial and final uncertainties, increasing or decreasing the uncertainty, and the uncertainty percentage at each stage. Furthermore, Maximum Entropy (ME) was applied to quantify the uncertainty in the entire process. Second, for the uncertainty quantification of radar rainfall estimation at each stage, this study used two quality control algorithms, two rainfall estimation relations, and two bias correction techniques as post-processing and progressed through all stages of the radar rainfall estimation. For the proposed approach, the final uncertainty (ME = 3.81) from the ME of the bias correction stage was the smallest while the uncertainty of the rainfall estimation stage was higher because of the use of an unsuitable relation. Additionally, the ME of the quality control was at 4.28 (112.34%), while that of the rainfall estimation was at 4.53 (118.90%), and that of the bias correction at 3.81 (100%). However, this study also determined that selecting the appropriate method for each stage would gradually reduce the uncertainty at each stage. Finally, the uncertainty due to natural variability was 93.70% of the final uncertainty. Thus, the results indicate that this new approach can contribute significantly to the field of uncertainty estimation and help with estimating more accurate radar rainfall.

Analytical Correction Method Based on a Comparison of the Column Shortening Measurement-Prediction in Tall Buildings (고층 건축물의 기둥축소량 계측-예측의 비교를 통한 해석보정 방안)

  • Song, Eun-Seok;Kim, Jae-Yo
    • Journal of the Computational Structural Engineering Institute of Korea
    • /
    • v.32 no.6
    • /
    • pp.391-399
    • /
    • 2019
  • In this study, an analytical method was proposed to correct the analysis results and minimize the errors between column shortening predictions and real values in high-rise buildings. In this regard, the construction sequence analysis of 41-story reinforced concrete buildings was performed and the results were compared to four assumed field measurements that were divided into the column and the core. The analysis correction was applied at a stage over the error limit in the column and at all stages in the core. Since the error occurred continuously after the analysis was corrected, additional corrections of the analysis resulted in a smaller error. By applying the proposed analytical correction method, it was confirmed that the long-term shortening value can be accurately predicted.

Effect of Ambient Temperature on Bovine Erythrocyte Sedimentation Rate as Measured by Angled Capillary Method (경사모세관법에 의한 우의 적혈구침강 속도에 미치는 환경온도의 영향)

  • Kim Kyeong-Jin;Lee Bang-Whan
    • Journal of Veterinary Clinics
    • /
    • v.4 no.1
    • /
    • pp.395-401
    • /
    • 1987
  • In this study, the effect of ambient temperature on the 45$^{\circ}$micro ESR/hr of cattle blood were observed, and a correction chart for correcting observed values at any ambient temperature to standard values at 20$^{\circ}C$ was plotted. Besides, the effect of storage temperature of blood on the 45$^{\circ}$micro ESR/hr was surveyed. The results were as follows: 1. The values of the 45$^{\circ}$micro ESR/hr were increased as the ambient temperature were elevated(P<0.01), and lower the value of PCV, higher the effect of temperature on the 45$^{\circ}$micro ESR/hr was observed(P<0.01). 2. Regression of values of 45$^{\circ}$micro ESR to ambient temperature in all the group of different level of blood PCV showed linear regression with the highly significant coefficient of correlation. With the results, correction chart was drawn as in Fig. 1. 3. In the purpose to verify the reliability of correction chart, observed values of 45$^{\circ}$micro ESR/hr in field(out door) were corrected to values at 20$^{\circ}C$ by the correction chart(Fig. 1), comparing with the observed values at 20$^{\circ}C$ of standard temperature. No significant differences were found between two groups mentioned above. 4. In the study on the effect of storage temperature of the blood on the 45$^{\circ}$micro ESR/hr, group of storage temperature at 5$^{\circ}C$ showed statistically no significant differences untill 24 hours in contrast with standard control group.

  • PDF

The Study on Read-write Education Method to Improve the Communication Ability for the Petty officer Majoring Students in Community Colleague (의사소통 능력 향상을 위한 부사관과의 읽기-쓰기 연계 교육방안)

  • Yu, Yong-tae
    • Convergence Security Journal
    • /
    • v.18 no.5_2
    • /
    • pp.73-82
    • /
    • 2018
  • The goal of this study is to look deeper into a read-write education method for improving communication abilities of petty officer majoring students in community colleague level. The read-write education method improves reading and writing abilities at the same time. Therefore, the read-write education method is modified to a 'read-write-correction' education method and the method is planed proper ways to run the course of the education. A writing report class method which is based on 'read-write' education method is the key process of this education. the education method suggests directions of a taking memo and a guideline of summarizing from the reading part, and the directions of a taking memo and a guideline of summarizing are used on report writings class from the writing part of the 'read-write' education method. The correction part of the education method is controlled by instructors under a process of the 'read-write-correction.' The read-write education method by using the report writing helps to improve communication abilities in work fields because the report writing is based on utilizing document formats that can be used future in petty officer work filed. For the last, the study mentions a proposal for further tasks on this field of the study.

  • PDF

THE SPECTRAL SHAPE MATCHING METHOD FOR THE ATMOSPHERIC CORRECTION OF LANDSAT IMAGERY IN SAEMANGEUM COASTAL AREA

  • Min Jee-Eun;Ryu Joo-Hyung;Shanmugam P.;Ahn Yu-Hwan;Lee Kyu-Sung
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.671-674
    • /
    • 2005
  • Atmospheric correction over the ocean part is more important than that over the land because the signal from the ocean is very small about one tenth of that reflected from land. In this study, the Spectral Shape Matching Method (SSMM) developed by Ahn and Shanmugam (2004) is evaluated using Landsat imagery acquired over the highly turbid Saemangeum Coastal Area. The result of SSMM is compared with COST model developed by Chavez (1991 and 1997). In principle, SSMM is simple and easy to implement on any satellite imagery, relying on both field and image properties. To assess the potential use of these methods, several field campaigns were conducted in the Saemangeum coastal area corresponding with Landsat-7 satellite's overpass on 29 May 2005. In-situ data collected from the coastal waters of Saemangeum using optical instruments (ASD field spectroradiometer) consists of ChI, Ap, SS, aooM, F(d). In order to perform SSMM, we use the in-situ water-leaving radiance spectra from clear oceanic waters to estimate the the path radiance from total signal recorded at the top of the atmosphere (TOA), due to the reason that the shape of clear water-leaving radiance spectra is nearly stable than turbid water-leaving radiance spectra. The retrieved water-leaving radiance after subtraction of path signal from TOA signal in this way is compared with that estimated by COST model. The result shows that SSMM enabled retrieval of water-leaving radiance spectra that are consistent with in-situ data obtained from Saemangeum coastal waters. The COST model yielded significantly high errors in these areas.

  • PDF

A Study on EUROFIX Reed Solomon Code Design Using Finite Galois Field Fourier Transformation (유한체 푸리에 변환을 이용한 EUROFIX RS Code 설계에 관한 연구)

  • Kim, Min-Jee;Kim, Min-Jung;Chung, Se-Mo;Cho, Hyung-Rae
    • Journal of Navigation and Port Research
    • /
    • v.28 no.1
    • /
    • pp.23-29
    • /
    • 2004
  • This paper deals with Reed-Solomon Coding for EUROFIX system EUROFIX is an integrated navigation and communication system, which combines Differential GNSS and Loran-C EUROFIX transmits DGNSS(Differential Global Navigation Satellite Systems) (data by pulse position modulation of Loran-C pulses. Loran-C system is regarded as a satellite backup system in recent. And now, it is important to detect and correct much errors in communication systems. Error corrections or correction algorithm is actively studied nowadays because of this. In this paper, we study and design encoder and decoder of Reed Solomon Code using Finite Galois Field Fourier Transformation for error corrections in EUROFIX data transmission. Through extensive simulation, the designed Reed Solomon code is shown to be effective for error correction in EUROFIX data transmission.

Thermal imaging sensor design using 320×240 IRFPA (320×240 적외선 검출기를 이용한 열상센서의 설계)

  • Hong Seok Min;Song In Seob;Kim Chang Woo;Yu Wee Kyung;Kim Hyun Sook
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.423-428
    • /
    • 2004
  • The development of a compact and high performance MWIR thermal imaging sensor based on the SOFRADIR 320${\times}$240 element IRCCD detector is described. The sensor has 20 magnification zoom optics with the maximum 40$^{\circ}$${\times}$30$^{\circ}$ of super wide field of view and 7.6 cycles/mrad of resolving power with the operation of attached micro-scanning system. In order to correct nonuniformities of detector arrays, we have proposed a multi-point correction method using defocusing of the optics and we have acquired the highest quality images. The MRTD of our system shows good results below 0.05K at spatial frequency 1 cycles/mrad at narrow field of view. Experimental data and obtained performances are presented and discussed.

Availability Evaluation of Network DGPS Positioning for Various Facilities Management In Dense Housing Area (주택가 밀집지역에서의 각종 시설물 관리를 위한 네트워크 DGPS 측위의 가용성 평가)

  • Kim, In-Seup
    • Journal of Korean Society for Geospatial Information Science
    • /
    • v.18 no.4
    • /
    • pp.93-99
    • /
    • 2010
  • Since the facility management for various facilities in urban area are conducted by general managers who have poor knowledge for surveying technology, it is not easy to trace the exact location of the facility in a short time with the GIS map only by themselves in the field. In order to improve it, VRS-RTK or SBAS DGPS system integrated with UMPC and PDA which is uploaded GIS field software are being used recently however lot of difficulties are still existed with the GPS positioning in urban area due to the lack of visible satellites, no reception of correction data and multipath error by the interruption of the high buildings and houses etc. Therefore, in this study, we applied with Network DGPS system which allows better reception of satellite signal and correction data even in dense housing areas with the use of GNSS receiver and CDMA mobile phone. Based on the analysis of field data, it was confirmed that standard deviations of the Network DGPS positioning are 0.3 to 0.84m with a very high positioning rate even in dense housing areas. Therefore, it was concluded that the Network DGPS system could be used widely to fast and accurate positioning for various facilities management works in dense housing areas in the future.

Measurement of ECF for $CaSO_4:Dy$ Thermoluminescent Dosimeters ($CaSO_4:Dy$ 열형광선량계의 소자보정인자(ECF) 산출)

  • Lim, Kil-Sung;Kim, Jang-Lyul
    • Journal of Radiation Protection and Research
    • /
    • v.30 no.4
    • /
    • pp.231-236
    • /
    • 2005
  • Dosimeters are manufactured from same process in the manufacturer but the deviation of TL raw counts exists among the dosimeters. TL raw counts are also gradually degrade due to multiple readings and physical abuse. ECF (Element Correction Factor) correct the degradation and deviation of TL raw counts to the average TL raw counts of reference dosimeters. Procedures for producing ECF of thermoluminescent dosimeters were described In detail. ECFs of 319 reference, control and field dosimeters were measured three times and average of three ECF values was calculated. Also, % CV(Coefficient of Variation) of three ECF values was calculated to verify ECF. ECF & % CV distributions for the field and control dosimeters are presented. TL raw counts of field dosimeters, being used about 6 times for the past 3 years, were almost unchanged, but those of control dosimeters being used more frequently, were degraded about 4.7 %.