• Title/Summary/Keyword: Field clinical practice

Search Result 299, Processing Time 0.032 seconds

Evaluation of the Usefulness of Virtual Reality Equipment for Relieving Patients' Anxiety during Whole-Body Bone Scan (전신 뼈 검사 환자의 불안감 해소를 위한 가상현실 장비의 유용성 평가)

  • Kim, Hae-Rin;Kim, Jung-Yul;Lee, Seung-Jae;Baek, Song-Ee;Kim, Jin-Gu;Kim, Ga-Yoon;Nam-Koong, Hyuk;Kang, Chun-Goo;Kim, Jae-Sam
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.26 no.1
    • /
    • pp.27-32
    • /
    • 2022
  • Purpose When performing a whole-body bone scan, many patients are experiencing psychological difficulties due to the close distance to the detector. Recently, in the medical field, there is a report that using virtual reality (VR) equipment can give pain relief to pediatric patients with weak concentration or patients receiving severe treatment through a distraction method. Therefore, in this paper, VR equipment was used to provide psychological stability to patients during nuclear medicine tests, and it is intended to evaluate whether it can be used in clinical practice. Materials and Methods As VR equipment, ALLIP Z6 VR (ALLIP, Korea) was used and the experiment was conducted after connecting to a mobile phone. The subjects were 30 patients who underwent whole-body bone examination from September 1, 2021 to September 30, 2021. After intravenous injection of 99mTc-HDP, 3 to 6 hours later, VR equipment was put on and whole body images were obtained. After the test, a survey was conducted, and a Likert scale of 5 points was used for psychological anxiety and satisfaction with VR equipment. Hypothesis verification and reliability of the survey were analyzed using SPSS Statistics 25 (IBM, Corp., Armonk, NY, USA). Results Anxiety about the existing whole-body bone test was 3.03±1.53, whereas that of anxiety after wearing VR equipment was 2.0±1.21, indicating that anxiety decreased to 34%. When regression analysis of the effect of the patient's concentration on VR equipment on anxiety about the test, the B value was 0.750 (P<0.01) and the t value was 6.181 (P<0.01). decreased and showed an influence of 75%. In addition, overall satisfaction with VR equipment was 3.76±1.28, and the intention to reuse was 66%. The Cronbach α value of the reliability coefficient of the questionnaire was 0.901. Conclusion When using VR equipment, patients' attention was dispersed, anxiety was reduced, and psychological stability was found. In the future, as VR equipment technology develops, it is thought that if the equipment can be miniaturized and the resolution of VR content images is increased, it can be used in various clinical settings if it provides more realistic stability to the patient.

Effects of the Massage Therapy on Weight, Stress Hormone and Mother - Infant Interaction (마사지요법이 저체중아의 성장, 생리적 변화 및 모.영아 상호작용에 미치는 효과)

  • Kim, Mi-Ye;Kim, Sun-Hee
    • Korean Parent-Child Health Journal
    • /
    • v.3 no.1
    • /
    • pp.1-14
    • /
    • 2000
  • The Low Birth Weight infant birth rate in this country is a little more than 15 percent and is being increased. The survival rate of Low Birth Weight infant is over 90 percent and recently the rate runs is getting. However, because of the high risk of Low Birth Weight infant for handicap in growth, a preventive nursing intervention program for Low Birth Weight infant and their mother is considered to be necessary. Touch and massage, thus sensory stimulation has been considered to be important ensuring a normal growth of Low Birth Weight infant During the past decades sensory stimulation program has been used for premature and Low Birth Weight infants. Recently a study on the sensory stimulation for Low Birth Weight infants has bee n done in this country. Mother and infant relationship has a great influence on child's development. Especially, mother and infant interaction during one year after birth plays important role in child's social. affective and cognitive developments. But in the study of Low Birth Weight infants, the mother and infant interaction has been rare yet. However, there was no study effectiveness of the sensory stimulation on mother and infant interaction. In this respect, this study based on the importance of the nursing intervention, is intended to measure the effectiveness of the massage therapy in the aspects of weight, daily feeding amount, cortisolurine stress hormone and mother and infant interactions. This study has been conducted on the nonequivalent control group pretestposttest design in quasi experimental basis and Low Birth Weight infants from NICU of two Medical University Hospitals located in Taegu Metropolitan were selected in experimental group of 21 infants and control group of 20 infants. Data has been collected from May 1, 1999 to September 5, 2000. For the experimental group Field's sensory stimulation(tactile and kinesthetic stimulation) was applied 2 times a day for 10 days(10:00 - 11:00 hours in the morning and 19:00 - 20:00 in the afternoon) by nurse and mother. The electronic indicator scale (Cas Co. Korea) was used to measure infant's body weight. To determine urine cortisol concentration level under stress, rad immuno assay method was used. And to determine mother and infant interactions during feeding, tools developed by Kim Mi-Ye (1999) were used. Collected data were analyzed with SAS program using x-test, t-test, paired t-test and repeated measures ANOVA. Findings were as follows : 1. For the daily mean weight gain, the experimental group showed little higher than the control group, even though, there was no Statistically significant differences between two groups. 2. For the amount of daily mean feeding, the experimental group showed little higher than the control group, while there was no Statistically significant differences between two groups. 3. The level of wine cortisol concentration was increased in both groups, while no Statistical significance was shown between the two groups. 4. Mothers in experimental group were more likely to have higher mean scores in mother and infant interaction during feeding than mothers in the control group. Statistical significance was shown between the two groups(t= 5.78, P=.001). In conclusion, the massage therapy in this study showed with regard to even though through there was no statistically significance in the weight gain and urine stress hormone concentration. there was Statistical significantly higher in the mother and infant interaction during feeding. Based on the result of this study, it is considered that the massage therapy should be applied clinical practice and home to help a developmental growth and interaction of Low Birth Weight infants and mothers during the period of recovery.

  • PDF

Association between Sleep Quality and Psychologic Factors among University Students in Korea (한국인 대학생에서 수면의 질과 정서적 요인에 관한 상관관계)

  • Kang, Jin-Kyu;Lim, Hyun-Dae;Lee, You-Mee
    • Journal of Oral Medicine and Pain
    • /
    • v.33 no.3
    • /
    • pp.257-267
    • /
    • 2008
  • The mentophysical disease causes diseases in digestive, respiratory, circulating systems, including chronic pain, through combined reactions from different individual characteristics, mental stress and temperamental factors. The most common symptom related to orofacial area is pain and the contributive factors include biological, behavioral, environmental, social, emotional, recognitive factors. These factors affect the course of the symptom according to individual's character and human nature. In pain, sleep acts as a contributive factor, and pain could bring about sleep disturbance and vice versa. Deterioration of sleep quality would act as a factor that aggravates mental stress. Therefore, relatively accurate and simple mental examinations and sleep quality test should be carried out for the patients with symptoms related to orofacial area. This study evaluated the mental state in relation to the sleep quality which could affect orofacial pain. The number of poor sleeper was 18 in male subjects, and 1 in female subjects and PSQI global index was higher in male($6.11{\pm}2.38$) than female($4.67{\pm}2.18$). SCL-90-R index showed no sex difference. Poor sleeper showed significantly high value in SOM, O-C, I-S, ANX, PHOB, PSY, GSI, PST. When SCL-90-R T scores were compared according to sleep quality, higher the subjective sleep quality score, O-C and I-S showed significant increase. As sleep disturbances score increased, PAR, PSY, PST showed statistically significant increase. In comparison of SCL-90-R T score according to daytime dysfunction, statistically significant increase in DEP, ANX, HOS, PHOB, PAR, GSI was observed. Therefore, the quality of sleep and psychological status have a high correlation. This is likely to influence chronic pain in the orofacial field. As a result, clinicians treating orofacial pain should evaluate the sleep quality and psychological status of the patient. Further studies of larger sample sizes including various age, occupation, and pain groups are necessary in order to apply the results to clinical practice.

Evaluation of Attenuation Rate Error on Skin Dosimeter using Monte Carlo Simulation in Photon and Electron Beam Therapy (광자선 및 전자선 치료에서 피부선량계의 측정과 시뮬레이션을 이용한 감약률 오차 평가)

  • Han, Moo-Jae;Yang, Seung-Woo;Heo, Seung-Uk;Bae, Sang-Il;Moon, Young-Min;Park, Sung-Kwang;Kim, Jin-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.841-848
    • /
    • 2020
  • In the field of radiation therapy using photon beams and electron beams, since each patient has a different sensitivity to radiation, skin side effects may occur even at the same dose. Therefore, if there is a risk of excessive dose to the skin, a dosimeter is attached to verify whether the correct dose is being investigated. However, since the skin dosimeter checks the attachment site visually by measuring a point dose, it is difficult to confirm an accurate dose distribution. As a result, the measurement and simulation errors of the material HgI2 in the 6 MV photon beam were 3.73% and 5.24%, respectively, at the minimum thickness of 25 ㎛, and the material PbI2 was 4.73% and 5.65%, respectively. On the other hand, as a result of the 6 MeV electron beam, the measurement and simulation errors of the material HgI2 were 1.35% and 1.12%, respectively, at a minimum thickness of 25 ㎛, and the material PbI2 showed relatively low attenuation error, 1.67% and 1.20%, respectively. Therefore, it was evaluated that the thickness of the photon beam within 25 ㎛ and the electron beam within 100 ㎛ is suitable to have a reduction rate error within 5%. This study presents a new research direction for a flexible dosimeter attached to the human body that is required in clinical practice and the construction conditions of a future skin dosimeter.

An analysis of one-year experience of pediatric observation unit: The first report in Korea (소아 관찰병실 운영에 대한 분석)

  • Lee, Jee Young;Choi, Ui-Yoon;Lee, Soo Young;Lee, Ji-Young;Lee, Byong Chan;Hwang, Hui Sung;Mok, Hye Rin;Jeong, Dae Chul;Chung, Seung Yun;Kang, Jin Han
    • Clinical and Experimental Pediatrics
    • /
    • v.50 no.7
    • /
    • pp.622-628
    • /
    • 2007
  • Purpose : While pediatric observation units (POU) have become a common practice in hospitals throughout developed countries, there has been no report about POUs in Korea so far. The aims of this study were to analyze our one-year's experience of the POU and to decide which disease entities are suitable for the POU. Methods : All children admitted from March 2006 to February 2007 to the POU at the Department of Pediatrics in Our Lady of Mercy Hospital were included in this study. Data were collected from retrospective reviews of their medical records. Results : There were a total of 1,076 POU admissions. Median age of patients was 2.4 years and median length of hospital stay 14.0 hours. The most common diagnoses were gastroenteritis (42.7%), pharyngotonsillitis (19.1%), bronchiolitis (7.8%), pneumonia (5.5%) and febrile seizure (5.2%). Overall, 7.5% of the POU patients required subsequent inpatient admissions due to hospital stays of longer than 48 hours. The disease entities that were most likely to require inpatient admission were pneumonia (17.0%), febrile seizure (12.5%) and asthma (11.5%). Diseases that allowed successful discharge from the POU were gastroenteritis (4.6%), upper respiratory tract infection (5.8%), such as otitis media and pharygnotonsillitis and seizure disorder (6.4%). Compared with the previous year when the POU was not in operation, there was a statistically significant reduction in the average length of hospital stays (from 4.69 to 3.75 days), as well as a rise in the bed turnover rate (from 78.8 to 98.2 patients/bed). Conclusion : Our study shows that the POU is efficient for the management of children with certain acute illnesses. Based on this study, we suggest that the POU be used as a new modality which links between the outpatient, inpatient, and emergency departments in the field of pediatrics in Korea.

A Statistical Analysis of the Fereign Bodies in the Food and air Passages (식도 및 기도이물의 임상통계학적 고찰)

  • 정해영;권평중;박성준;민양기;김중환
    • Proceedings of the KOR-BRONCHOESO Conference
    • /
    • 1978.06a
    • /
    • pp.4.1-4
    • /
    • 1978
  • The foreign bodies in the food and air passages are frequently observed in the field of otolaryngology, and the foreign bodies in the air passages have much significance in clinical practice because they may cause sudden death. A statistical study was done on 95 cases of foreign bodies in the food and air passages who had visited department of otolaryngology, Chung-Ang university from June, 1968 to April, 1978. The results were as follows; 1. The total cases of foreign bodies in the food and air passages was 95; 89 cases (93.7%) were in the food passage and the remaining (6.3%) were in the air passage. The ratio between the food passage and air passage was about 14. 8 to 1.0. 2. In distribution by sex, 64 cases (67.4%) were in male patients and the remaining 31 cases (32.6%) were in female patients. The ratio between male and female was 2.1 to 1.0. 3. The kinds of foreign bodies in the food in the order of their frequency, were coin, gogame stone and pebble. In the air passages, the peanut and bean were most frequently found. 4. In distribution by age, 64 cases (67.4%) of all foreign bodies were found in children under 5 year old, and coin was the most common kind of foreign body. Except for meat, almost all of foreign bodies were found in children under 10 year old. 5. There was chronologically no significant tendency in incidence; the incidence, however, had decreased during recent 2 years. 6. In the location of foreign bodies in the food passage, 70 cases (78.7%) were found at the first esophageal narrowing. Meat was more frequently found at second esophageal narrowing associated with cicatrical stenosis. Almost all of foreign bodies in the air passage was found in bronchi; 3 cases were in the right side of bronchi, and 2 cases were in the left side of bronchi and 1 case was in glottic region. 7. In duration of lodgement, 50 cases (52.6%) visited our hospital within 24 hours, and 3 cases after 30 days. 8. Under topical anesthesia, 83 cases (93.3%) of the foreign bodies in the food passage were removed by esophagoscopy, by 6 cases (6.7%) failed to be removed. All of the foreign bodies of the air passages (6 cases) were removed by bronchoscopy. Among them, 5 cases under 5 years old were removed by inferior bronchoscopy through tracheostomy site.

  • PDF

Development of $14"{\times}8.5"$ active matrix flat-panel digital x-ray detector system and Imaging performance (평판 디지털 X-ray 검출기의 개발과 성능 평가에 관한 연구)

  • Park, Ji-Koon;Choi, Jang-Yong;Kang, Sang-Sik;Lee, Dong-Gil;Seok, Dae-Woo;Nam, Sang Hee
    • Journal of radiological science and technology
    • /
    • v.26 no.4
    • /
    • pp.39-46
    • /
    • 2003
  • Digital radiographic systems based on solid-state detectors, commonly referred to as flat-panel detectors, are gaining popularity in clinical practice. Large area, flat panel solid state detectors are being investigated for digital radiography. The purpose of this work was to evaluate the active matrix flat panel digital x-ray detectors in terms of their modulation transfer function (MTF), noise power spectrum (NPS), and detective quantum efficiency (DQE). In this paper, development and evaluation of a selenium-based flat-panel digital x-ray detector are described. The prototype detector has a pixel pitch of $139\;{\mu}m$ and a total active imaging area of $14{\times}8.5\;inch^2$, giving a total 3.9 million pixels. This detector include a x-ray imaging layer of amorphous selenium as a photoconductor which is evaporated in vacuum state on a TFT flat panel, to make signals in proportion to incident x-ray. The film thickness was about $500\;{\mu}m$. To evaluate the imaging performance of the digital radiography(DR) system developed in our group, sensitivity, linearity, the modulation transfer function(MTF), noise power spectrum (NPS) and detective quantum efficiency(DQE) of detector was measured. The measured sensitivity was $4.16{\times}10^6\;ehp/pixel{\cdot}mR$ at the bias field of $10\;V/{\mu}m$ : The beam condition was 41.9\;KeV. Measured MTF at 2.5\;lp/mm was 52%, and the DQE at 1.5\;lp/mm was 75%. And the excellent linearity was showed where the coefficient of determination ($r^2$) is 0.9693.

  • PDF

Development of Dynamic Kidney Phantom System and its Evaluation of Usability of Application in Nuclear Medicine (핵의학 동적 신장팬텀시스템 개발 적용의 유용성 평가)

  • Park, Hoon-Hee;Lee, Juyoung;Kim, Sang-Wook;Lyu, Kwang Yeul;Jin, Gye Hwan
    • Journal of radiological science and technology
    • /
    • v.36 no.1
    • /
    • pp.49-55
    • /
    • 2013
  • Currently, commercially available phantom can reproduce and evaluate only a static situation, the study is incomplete research on phantom and system which is can confirmed functional situation in the kidney by time through dynamic phantom and blood flow velocity, various difference according to the amount of radioactive. Therefore, through this study, it has produced the dynamic kidney phantom to reproduce images through the dynamic flow of the kidney, it desires to evaluate the usefulness of nuclear medicine imaging. The production of the kidney phantom was fabricated based on the normal adult kidney, in order to reproduce the dynamic situation based on the fabricated kidney phantom, in this study, it was applied the volume pump that can adjust the speed of blood flow, so it can be integrated continuously radioactive isotopes in the kidney by using $^{99m}Tc$-pertechnate. Used the radioactive isotope was supplied through the two pump. It was confirmed the changes according to the infusion rate, radioactive isotopes and the different injection speeds on the left and right, analysis of the acquired images was done by drawn five times ROI in order to check the reproducibility of each on the front and rear of the kidney and bladder. Depending on the speed of injection, radioisotope was a lot of integrated and emissions up when adjusting the pressure of the pump as 30 stroke, it was the least integrated and emissions up when adjusting as 40 stroke. The integration of the left & right kidney was not reached in the amount of the highest when adjusting as 10 stroke. In the changes according to the amount of the radioactive isotope, 0.6 mCi(22.2 MBq), 0.8 mCi (29.6 MBq)was showed up similar tendency but, in the result of the different injection 0.8 mCi, it was showed up counts close to double of 0.6 mCi. In the result of the differently injection speed of the left & right kidney, as a result of different conditions that injection speed was 20 stroke through left kidney phantom, the injection speed was 30 stroke through right kidney phantom, it was enough difference in the resulting image can be easily distinguished with the naked eye. Through this study, the results showed that the dynamic kidney phantom system is able to similarly reproduce renogram in the actual clinical practice. Especially, the depicted over time for the flow to be excreted through the kidney into the bladder was adequately reproduce, it is expected to be utilized as basic data to check the quality of the dynamic images. In addition, it is considered to help in the field of functional imaging and quality control.

Hybrid Natural Orifice Transluminal Endoscopic Cholecystectomy in Dogs: Transgastric, Transcolonic and Transvaginal Approaches (개에서 자연개구부를 통한 하이브리드 내시경적 담낭절제술: 경위장관, 경결장 및 경질 접근법)

  • Kim, Soo-Hyun;Jeong, Seong-Mok;Shin, Sa-Kyeng;Kim, Seong-Su;Shin, Beom-Jun;Lee, Jae-Yeon;Park, Ji-Yeong;Kim, Myung-Cheol;Kim, Young-Il;Lee, Sang-Il;Kim, Ji-Yeon
    • Journal of Veterinary Clinics
    • /
    • v.28 no.5
    • /
    • pp.497-505
    • /
    • 2011
  • Natural orifice transluminal endoscopic surgery is a newly emerging technique recently, with its many potential advantages in clinical practice. Cholecystectomy by Hybrid NOTES in this work, performed with single working channel endoscope in conjunction with a laparoscopic grasping forceps in dogs, is a "bridge" between laparoscopic procedure and pure NOTES. Three different approaches for cholecystectomy were carried out; transgastric, transcolonic and transvaginal. In all three approaches, abdominal opening was made by a 5 mm trocar, followed by making pneumoperitoneum of 4 mmHg with $CO_2$ insufflator. Transgastric cholecystectomy, single working channel endoscope was advanced to the peritoneal cavity through gastric incision in antral region made by endoscopic needle knife. Endoscope was retroflexed to visualize the gall bladder. Transcolonic access, incision for endoscopic entry was done at right ventral wall of descending colon, 15 cm inside from the anus. Incision in transvaginal access was made at right-ventral region, just caudal to the caudal tubercle. With the simple traction by the laparoscopic grasping forceps, good visualization of surgical field was obtained in all three groups. Cystic duct and artery were ligated with endoclips; for complete gall bladder dissection from liver, L-knife was used. Closure of incision sites were done in transgastric and transcolonic cholecystectomy by endoclips, not in transvaginal approach.