• Title/Summary/Keyword: Field Reduction Factor

Search Result 231, Processing Time 0.026 seconds

Fabrication of the 7$\times$7 mm Planar Inductor for 1W DC-DC Converter (1W DC-DC 컨버터를 위한 7$\times$7 mm 평면 인덕터의 제조)

  • Bae, Seok;Ryu, Sung-Ryong;Kim, Choong-Sik;Nam, Seoung-Eui;Kim, Hyoung-June;Min, Bok-Ki;Song, Jae-Sung
    • Journal of the Korean Magnetics Society
    • /
    • v.11 no.5
    • /
    • pp.222-225
    • /
    • 2001
  • The planar type inductors have a good potential for the application of miniaturized low power DC-DC converters. For those high quality application, the reduction of coil loss and also magnetic films which have good high frequency properties are required. Fabricated inductor was consisted of FeTaN/Ti magnetic film and electroplated Cu coil thickness of 100$\mu\textrm{m}$ and $SiO_2$ as a insulating layer. The inductor was designed double rectangular spiral shape for magnetic field highly confining within the device. The measured value of inductance and resistance were 980 nH and 1.7 $\Omega$ at 1 MHz as operating frequency of device. The Q factor is 3.55 at 1 MHz.

  • PDF

Sound Design to Improve the Quality of Noise from Home Appliances (가전 제품의 음질 향상을 위한 음설계 연구)

  • 주재만;이제원;오상경;이나경
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.1122-1127
    • /
    • 2003
  • For many years, engineers in the field of acoustics have used the A-weighted sound pressure level (SPL). Since they were interested just in a reduction of noise, the A-weighted SPL was considered good enough to quantify noise problems. This is reasonable because loudness is usually the most important parameter for most noise problems and A-weighted SPL is often reasonably well correlated with loudness. As the overall noise levels drop, however, other parameters become more important and must be considered, Advent of sound quality came from an understanding that A-weighted SPL only reflects the loudness of a sound. It is obviously impossible to characterize a complex sound with a single number. Although product mostly has revealed physical quantities created by the standpoint of engineers, consumers perceive and evaluate products on the non-physical characteristics, such as feelings, emotions, and experiences in different social and cultural situations. Especially, for the household appliances for instance air-conditioner or refrigerator, the sound is heavily related to the satisfaction of a customer who is a real user of the product and is very important factor to decide purchasing as well as visual design. Therefore, in this research, the general tendency of consumer's psychology was investigated for the appliances. And also, in order to obtain clear guidelines fur sound manipulation, the characteristics of the sound of air-conditioning systems and refrigerators were compared with competitors'. since it is important to overcome the discrepancy between engineering and marketing, the relevance of sound manipulation must be documented from the consumer's perspective. That is the reason why we conducted a consumer and marketing oriented study.

  • PDF

Influence of Inadequate Rebar Lap Position on Crack of Underground Box Slab (철근 겹침이음 위치 부적정이 지하박스 슬래브 균열 발생에 미치는 영향)

  • Choi, Jung-Youl;Jang, In-Soo;Chung, Jee-Seung
    • The Journal of the Convergence on Culture Technology
    • /
    • v.6 no.4
    • /
    • pp.685-692
    • /
    • 2020
  • In this study, the experimental and analytical study were performed on the location of longitudinal cracks in the middle of underground box structures. The location where the longitudinal cracking occurred was investigated that the overlapping joint of the rebar and the section of maximum tensile stress generated. Using the finite element analysis, the strength reduction ratio of the rebar was estimated by lack of overlap joint length. As the result of adequacy investigation for the length of the overlap joint presented in the design criteria, it was analytically proved that the lack of the overlap joint length could be cause the decreasing cross-sectional force and concrete cracking. As the result of this study, the adequacy of the overlapping criterion in the current design criteria was confirmed based on the finite element analysis and actual field case. In the case of overlapping joints installed in inappropriate position, it was considered that a long term crack control would be need to ensure the sufficient safety factor for the designed cross-sectional force.

Development of bias correction scheme for high resolution precipitation forecast (고해상도 강수량 수치예보에 대한 편의 보정 기법 개발)

  • Uranchimeg, Sumiya;Kim, Ji-Sung;Kim, Kyu-Ho;Kwon, Hyun-Han
    • Journal of Korea Water Resources Association
    • /
    • v.51 no.7
    • /
    • pp.575-584
    • /
    • 2018
  • An increase in heavy rainfall and floods have been observed over South Korea due to recent abnormal weather. In this perspective, the high-resolution weather forecasts have been widely used to facilitate flood management. However, these models are known to be biased due to initial conditions and topographical conditions in the process of model building. Theretofore, a bias correction scheme is largely applied for the practical use of the prediction to flood management. This study introduces a new mean field bias correction (MFBC) approach for the high-resolution numerical rainfall products, which is based on a Bayesian Kriging model to combine an interpolation technique and MFBC approach for spatial representation of the error. The results showed that the proposed method can reliably estimate the bias correction factor over ungauged area with an improvement in the reduction of errors. Moreover, it can be seen that the bias corrected rainfall forecasts could be used up to 72 hours ahead with a relatively high accuracy.

Modified p-y curves to characterize the lateral behavior of helical piles

  • Hyeong-Joo, Kim;James Vincent, Reyes;Peter Rey, Dinoy;Tae-Woong, Park;Hyeong-Soo, Kim;Jun-Young, Kim
    • Geomechanics and Engineering
    • /
    • v.31 no.5
    • /
    • pp.505-518
    • /
    • 2022
  • This study introduces soil resistance multipliers at locations encompassed by the zone of influence of the helix plate to consider the added lateral resistance provided to the helical pile. The zone of influence of a helix plate is a function of its diameter and serves as a boundary condition for the modified soil resistance springs. The concept is based on implementing p-multipliers as a reduction factor for piles in group action. The application of modified p-y springs in the analysis of helical piles allows for better characterization and understanding of the lateral behavior of helical piles, which will help further the development of design methods. To execute the proposed method, a finite difference program, HPCap (Helical Pile Capacity), was developed by the authors using Matlab. The program computes the deflection, shear force, bending moment, and soil resistance of the helical pile and allows the user to freely input the value of the zone of influence and Ω (a coefficient that affects the value of the p-multiplier). Results from ten full-scale lateral load tests on helical piles embedded at depths of 3.0 m with varying shaft diameters, shaft thicknesses, and helix configurations were analyzed to determine the zone of influence and the magnitude of the p-multipliers. The analysis determined that the value of the p-multipliers is influenced by the ratio between the pile embedment length and the shaft diameter (Dp), the effective helix diameter (Dh-Dp), and the zone of influence. Furthermore, the zone of influence is recommended to be 1.75 times the helix diameter (Dh). Using the numerical analysis method presented in this study, the predicted deflections of the various helical pile cases showed good agreement with the observed field test results.

Application of data-driven model reduction techniques in reactor neutron field calculations

  • Zhaocai Xiang;Qiafeng Chen;Pengcheng Zhao
    • Nuclear Engineering and Technology
    • /
    • v.56 no.8
    • /
    • pp.2948-2957
    • /
    • 2024
  • High-order harmonic techniques can be used to recreate neutron flux distributions in reactor cores using the neutron diffusion equation. However, traditional source iteration and source correction iteration techniques have sluggish convergence rates and protracted calculation periods. The correctness of the implicitly restarted Arnoldi method (IRAM) in resolving the eigenvalue problems of the one-dimensional and two-dimensional neutron diffusion equations was confirmed by computing the benchmark problems SLAB_1D_1G and two-dimensional steady-state TWIGL using IRAM. By integrating Galerkin projection with Proper Orthogonal Decomposition (POD) techniques, a POD-Galerkin reduced-order model was developed and the IRAM model was used as the full-order model. For 14 macroscopic cross-section values, the TWIGL benchmark problem was perturbed within a 20% range. We extracted 100 sample points using the Latin hypercube sampling method, and 70% of the samples were used as the testing set to assess the performance of the reduced-order model The remaining 30% were utilized as the training set to develop the reduced-order model, which was employed to rebuild the TWIGL benchmark problem. The reduced-order model demonstrates good flexibility and can efficiently and accurately forecast the effective multiplication factor and neutron flux distribution in the core. The reduced-order model predicts keff and neutron flux distribution with a high degree of agreement compared to the full-order model. Additionally, the reduced-order model's computation time is only 10.18% of that required by the full-order model.The neutron flux distribution of the steady-state TWIGL benchmark was recreated using the reduced-order model. The obtained results indicate that the reduced-order model can accurately predict the keff and neutron flux distribution of the steady-state TWIGL benchmark.Overall, the proposed technique not only has the potential to accurately project neutron flux distributions in transient settings, but is also relevant for reconstructing neutron flux distributions in steady-state conditions; thus, its applicability is bound to increase in the future.

Experimental Study on Vibration Reduction Characteristics of Polymer Concrete (폴리머 콘크리트의 진동저감 특성에 대한 실험적 연구)

  • Kim, Jeong-Jin;Shim, Hak-Bo
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.23 no.7
    • /
    • pp.58-65
    • /
    • 2019
  • Polymer concrete is expected to be widely used as a building material because it has a shorter hardening time and excellent compression, tensile, bending, bond strength, frictional resistance and abrasion loss compared to general concrete. The polymer concrete has excellent vibration damping performance and research on the use of various reinforcing materials is being conducted. However, in order to completely replace the general concrete and the general anti-vibration reinforcement, such polymer concrete requires an overall review of vibration reduction performance considering physical properties, dynamic properties, productivity and field applicability. In this study, the physical and dynamic properties of polymer concrete by epoxy mixing ratio were compared with those of general concrete. It was appeared that compression, tensile, bending and bond strengths of polymer concrete by epoxy mixing were significantly higher than those of general concrete. Especially, the tensile strength was more than 4 ~ 6.5 times. Based on the basic physical properties of polymer concrete, the damping ratio, which is a dynamic characteristic according to the epoxy mixing ratio, was derived through analytical models and experiments. As a result, the dynamic stiffness of polymer concrete was 20% higher than that of general concrete and the loss rate was about 3 times higher.

Application of QUAL-2E Model for Water Quality Management in the Keum River -Waste loads Allocation Analysis by Considering Autochthonous BOD- (금강수계의 수질관리를 위한 QUAL-2E 모델의 적용(II) -자생BOD를 고려한 허용오염부하량 산정-)

  • 김종구;이지연
    • Journal of Environmental Science International
    • /
    • v.10 no.1
    • /
    • pp.21-25
    • /
    • 2001
  • The Keum river has been utilized for drinking water supply of several city including Kunsan city and is deepening pollution state due to numerous municipal and industrial discharges. The concentration BOD in river is affected by the organic loading from a tributary and the algae biomass that largely happen to under eutrophication state. In the eutrophic water mass such as the Keum river, the autochthonous BOD was very important part for making a decision of water quality management, because it was accounted for majority of the total BOD. The predict of water quality has important meaning for management of water quality pollution of the Keum river. The purpose of this study will manage and predict water quality of the Keum river using QUAL-2E model considering the autochthonous BOD. The estimation of autochthonous BOD represented that the relationship between BOD and chlorophyll a. The regression equation was shown to be autochthonous BOD=$\beta$(sub)5$\times$chlorophyll a. The results of this study may be summarized as followed; The QUAL-2E model was calibrated with the data surveyed in the field of the study area in June, 1998. The calculated value by QUAL-2E model are in good agree to measured value within relative error of 7.80~20.33%. Especially, in the case of the considering autochthonous BOD, the calculated value of BOD were fairly good coincided with the observed values within relative error of 15%. But the case of not considering autochthonous BOD, relative error of BOD was shown to be 43.2%. In order to attain II grade of water quality standard in Puyo station which has a intake facility of water supply, we reduced to the pollutants loading of tributaries. In the case of removed 100% BOD of tributaries, the BOD of Puyo station was 4.07mg/$\ell$, belong to III grade of water quality standard. But in the case of removed 88% nutrient of tributaries, it was satisfied to II grade of water quality standard as below 3mg/$\ell$ of BOD. For estimation of autochthonous BOD in Keum river, we are performed simulating in accordance with reduction of nutrient load(50~100%) under conditions removal 90% organic load. Occupancy of autochthonous BOD according to nutrient loading reductions were varied from 25.97~79.51%. Occupancy of autochthonous BOD was shown to be a tendency to increasing in accordance with reduction of nutrient loading. Showing the above results, the nutrient that one of the growing factor of algae was important role in decision of BOD in the Keum river. For the water quality management of the Keum river, therefore, it is necessary to considering autochthonous BOD and to construction of advanced sewage treatment plant for nutrient removal.

  • PDF

Bandwidth Enhanced Miniaturization Method of Parallel Coupled-Line Filter (대역폭 특성이 개선된 평행 결합 선로 필터의 소형화 기법)

  • Myoung, Seong-Sik;Yook, Jong-Gwan
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.18 no.2 s.117
    • /
    • pp.126-135
    • /
    • 2007
  • This paper proposes a new miniaturization method for a parallel coupled line filter with enhanced bandwidth characteristics. A previous method incorporated several advantages, such as size reduction through the use of only a small number of capacitors, in addition to grounding, suppression of harmonic characteristics, and improved skirt characteristics for the parallel coupled line filter, which is conventional in the field of RE filters due to its design and fabrication simplicity. However, the previous method also has disadvantages related to the bandwidth shrinkage of the miniaturized filters. In this paper, the amount of bandwidth shrinkage is analyzed in terms of the relationship between the loaded Q(quality factor) and the group delay of a resonator. Moreover, the reduction in the bandwidth is solved by a design with new design equations. To show the validity of the proposed method, a hairpin filter with a center frequency of 5.2 GHz and an fractional bandwidth(FBW) of 10% was scaled down to half its original dimension by the proposed method with the enhanced bandwidth characteristics. The measured result shows a high level of agreement with theoretical results.

Optimum Mix of Extrusion panel Using Low Energy Curing Admixture (LA) based on Ground Granulated Blast-Furnace Slag and Ladle Furnace Slag (고로슬래그와 환원슬래그를 기반으로 한 저에너지양생용 결합재를 사용한 압출성형패널의 최적배합)

  • Kim, Ha-Seog;Baek, Dae-Hyun;Lee, Sea-Hyun
    • Resources Recycling
    • /
    • v.24 no.2
    • /
    • pp.13-22
    • /
    • 2015
  • $CO_2$ emitted from building materials and construction materials industry reaches about 67 million tons, which occupy about 30 % of $CO_2$ emitted from the construction field. Controls on the use of consumed fossil fuels and reduction of emission gases are essential for the reduction of $CO_2$ in the construction area as we reduce the second and third curing to emit $CO_2$ in the construction materials industry. Accordingly, this study applied the low energy curing admixture (hereinafter "LA") to the extruded panels to observe the physical properties, depending on the mixing amount of fiber, type of fiber and mixing ratio of fiber. The type of fiber did not appear to be a main factor to affect strength, while the LA mixing ratio and mixing amount of fiber appeared to be major factors to affect strength. Especially, the highest strength was developed when the LA mixing ratio was 40%, whereas the test object with the mixing ratio of 50% resulted in the decrease of strength. In addition, it appeared that the mixing ratio of fiber greatly affected flexural strength and strength increased as the mixing ratio increased.