• Title/Summary/Keyword: Field Reduction Factor

Search Result 229, Processing Time 0.031 seconds

A Study on the Realization of Protocol Stack for I/O Elements Control for Multi-devices and Field Level

  • Kwak, Chang-Yong;Kim, Tae-Hwa;Kwon, Soon-Jae;Son, Jeong-Ki
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 2001.10a
    • /
    • pp.52.1-52
    • /
    • 2001
  • System establishment using a network may be a decisive factor both for creating a flexible production system and increasing reliability and serve as a basis for setting up of a management system that will make the designing, maintenance, and repair easier. It is therefore imperative to develop a protocol which is simple to use for communications and connections among different devices. The objectives of this study is to establish communications protocol stack that will enable to conduct an effective monitoring of production facilities and to secure flexibility of reduction control system, and to improve the working ratio of the production facilities by centralization of communications system through effective collecting and storing of the diversified data of multi-type and multi-device production facilities.

  • PDF

On the Behavior of Liquid Droplets Depending upon ALR in Two-phase Internal Mixing Nozzle Jet (2상 내부 혼합형 노즐분사에서 ALR 변화에 따른 액적의 거동)

  • Kim Kyu Chul;Namkung Jung Hwan;Lee Sang Jin;Rho Byung Joon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.385-388
    • /
    • 2002
  • The researches of a two-phase atomizers have been carried out in the field of automotive and aerospace industries in order to improve the atomization performance of the liquid droplets ejecting from these nozzles. The smaller droplets have the advantages of the reduction of environmental pollution matter and effective use of energy through the improvement of heat and mass transfer efficiency. Thus, to propose the basic information of two-phase flow, an internal mixing atomizer was designed, its shape factor was 0.6 and the liquid feeding hole was positioned at the center of the mixing tube which was used to mix the air and liquid. The experimental work was performed in the field after the nozzle exit orifice. The measurement of the liquid droplets was made by PDPA system. This system can measure the velocity and size of the droplets simultaneously. The number of the droplets used in this calculation was set to 10,000. The flow patterns were regulated by ALR (Air to Liquid mass Ratio). ALR was varied from 0.1024 to 0.3238 depending on the mass flow rate of the air. The analysis of sampling data was mainly focused on the spray characteristics such as flow characteristics distributions, half-width of spray, RMS, and turbulent kinetic energy with ALR.

  • PDF

Estimation of Drag Factors Between Roadway Surface and Human Body (인체와 노면간의 마찰계수 추정에 관한 연구)

  • Kim, Min-Tae;Lee, Sang-Soo;Lee, Chul-Ki
    • The Journal of The Korea Institute of Intelligent Transport Systems
    • /
    • v.9 no.6
    • /
    • pp.54-62
    • /
    • 2010
  • The scientific analysis of car-pedestrian accidents is not an easy task because of the characteristic of the accidents itself. Since the analysis involved human being, there were few experimental data that could be used for the analysis. The coefficient of friction of human body was the one of crucial data for accident analysis, but no field experiment report was available for various roadway conditions. This study intends to measure the coefficient of friction of human body through field studies. Results showed that the coefficient of friction of human body for dry asphalt pavement conditions was 0.59~0.62, and for dry concrete pavement conditions was 0.59~0.61. In addition, the coefficients for wet asphalt pavement and for wet concrete pavement conditions were 0.56~0.59 and 0.51~0.54 respectively, indicating 5.0% and 8.3% reduction compared to the dry conditions. The deduced coefficients were validated using the simulation program. It has been confirmed that the experiment values were close to the simulation results.

Application of Pay Adjustment Regulation for Highway Flexible Pavements (도로 포장의 초기상태에 따른 공사비 차등지급규정의 시험적용)

  • Seo, Young-Guk
    • International Journal of Highway Engineering
    • /
    • v.11 no.3
    • /
    • pp.111-120
    • /
    • 2009
  • Recently, pay adjustment regulation (PAR) has been developed to induce better performing road pavements around the country. This regulation was successfully applied during rehabilitation of highway flexible pavements for the first time, and their results are the focus of this paper. For highway pavements, a lot has been defined by typical amount of works a day. This lot was further divided into several sublots depending on field conditions. According to AASHTO Quality Assurance Guide Specification, pay factors for each lot were statistically determined with field measurements of five performance indicators. And composite pay factors were calculated by accounting for the impact of individual performance indicators on a long-term performance of pavement. In 2008, the PAR was tested with asphalt overlays conducted at all six local headquarters of Korea Expressway Corporation. Also, concerns raised during implementation are discussed in this paper. Limited data used in this study showed that if all performance indicators fall within the construction limits with less variances final construction costs may increase by 50%, whereas 10% reduction in construction costs could be necessary if key performance indicators such as density do not meet the construction quality requirements.

  • PDF

A Study on the Effective Utilization Plan through Field Investigation and Analysis with Power Transformers in Domestic Areas

  • Shin, Heung-Sik;Lee, Jae-Cheon;Bai, Seok-Myung;Kim, Seon-Gu;Kim, Jin-Tae;Kim, Gi-Hyeon;Jeong, Jong-Wook;Bang, Seon-Bae
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.21 no.4
    • /
    • pp.88-95
    • /
    • 2007
  • Korea is highly dependent on foreign countries for energy while at the same time having a high energy-consumption industrial structure. Therefore, logical improvements in energy use efficiency and nationwide energy saving are becoming more and more important in coping with the worldwidehigh oil prices and environmental issues such as listed in the Kyoto Protocol to the United Nations Framework Convention on Climate Change. Consequently, a study was conducted on the average annual load factor in domestic areas to set a reasonable and reliable technology standard plan for high-efficiency transformers. The average annual load factor in Korea was discovered to be 18.4[%] classified by industry. This factor is expected to be used in arranging a domestic standard for a minimum efficiency system for transformers, and in reviewing and supplementing the standard transformers plan for the High Energy-Efficiency Appliance Certification. The expected effect from the establishment of the technology standards plan for highly efficient transformers is the expansion of the manufacturing and distribution of highly efficient transformers that are suitable for domestic use. These will lead to electricity cost savings for users, strengthening the related industries' market competitive powers and the effective reduction of greenhouse gases on a national level by drastically reducing loss from transformers, which accounts for a large portion of the total electric supply losses.

Study on Reduction Factors of Residual Pesticides in Processing of Ginseng(I) (인삼 가공 중 잔류농약의 감소계수연구 ( I ))

  • In, Moo-Hyeog;Kwon, Kwang-Il;Park, Kun-Sang;Choi, Dong-Mi;Chang, Moon-Ik;Jeong, Ji-Yoon;Lee, Kyung-Jin;Yun, Won-Kap;Hong, Moo-Ki;Woo, Gun-Jo
    • The Korean Journal of Pesticide Science
    • /
    • v.10 no.1
    • /
    • pp.22-27
    • /
    • 2006
  • The aim of this study was to establish the maximum residue limits(MRLs) of fenhexamid, azoxystrobin and cyprodinil pesticides in ginseng products. The pesticides were applied to the cultivation field of ginseng, and they were harvested and processed to make dried ginseng and ginseng extract. The reduction factors of residual pesticides were calculated by determination of the pesticides in each processing stage of ginseng. Reduction factor (dry basis) of pesticides (azoxystrobin, fenhexamid, cyprodinil) were 0.73, 0.96 and 0.24 for dried ginseng and 3.23, 5.74 and 1.20 for ginseng extract. All the residual pesticides were reduced by drying or processing of ginseng, however, fenhexamid did not.

Estimation for Primary Tunnel Lining Loads

  • Kim, Hak-Joon
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1998.05a
    • /
    • pp.153-204
    • /
    • 1998
  • Prediction of lining loads due to tunnelling is one of the major issues to be addressed in the design of a tunnel. The objective of this study is to investigate rational and realistic design loads on tunnel linings. factors influencing the lining load are summarized and discussed. The instruments for measuring the lining loads are reviewed and discussed because field measurements are often necessary to verify the design methods. Tunnel construction in the City of Edmonton has been very active for storm and sanitary purposes. Since the early 1970's, the city has also been developing an underground Light Rail Transit system. The load measurements obtained from these tunnels are compared with the results from the existing design methods. However, none of the existing methods are totally satisfactory, Therefore, there is some room for improvement in the prediction of lining loads. The convergence-confinement method is reviewed and applied to a case history of a tunnel in Edmonton. The convergence curves are obtained from 2-D finite element analyses using three different material models and theoretical equations. The limitation of the convergence-confinement method is discussed by comparing these curves with the field measurements. Three-dimensional finite element analyses are performed to gain a better understanding of stress and displacement behaviour near the tunnel face. An improved design method is proposed based on the review of existing design methods and the performance of numerical analyses. A specific method or combination of two different methods is suggested for the estimation of lining loads for different conditions of tunnelling. A method to determine the stress reduction factor is described. Typical values of dimensionless load factors nD/H for tunnels in Edmonton are obtained from parametric analyses. Finally, the loads calculated using the proposed method are compared with field measurements collected from various tunnels in terms of soil types and construction methods to verify the method. The proposed method gives a reasonable approximation of the lining loads. The proposed method is recommended as an approximate guideline for the design of tunnels, but the results should be confirmed by field measurements due to the uncertainties of the ground and lining properties and the construction procedures, This is the reason that in-situ monitoring should be an integral part of the design procedure.

  • PDF

Evaluation for Noise Reduction of the HVAC by Modification of CAM Curve (CAM 곡선 개선에 의한 차량용 공조기의 소음 저감 평가)

  • Jeong, J.E.;Jung, C.Y.;Seo, B.J.;Jeong, U.C.;Oh, J.E.
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.21 no.9
    • /
    • pp.787-797
    • /
    • 2011
  • The noise in a vehicle is an important factor for customers purchasing a car. Particularly, reduction of the noise that is generated from HVAC(heating, ventilation and air conditioning) is very important since it has considerable effects on interior noise. In general, identification of noise source is crucial to reduce noise level. The complex acoustic intensity method is widely used to obtain the accurate measurement and identification of noise source. Therefore, in the previous study, noise source of HVAC was identified through experimental approach using the complex acoustic intensity method. In this study, we are intended to confirm reduced level of noise by comparing the result between before and after modification of cam curve that is based on identified noise source of HVAC. It is found out that noise source of HVAC are motor and cam area using the complex acoustic intensity method in the previous study. We performed experiments to compare noise level between before and after modification of cam curve. Especially, it can be seen that complex acoustic intensity method using both active and reactive intensity is vital in devising a strategy for comparison to noise level. Also, the vector flow of acoustic intensity was investigated to identify sound intensity distributions and energy flow in the near field of HVAC.

A numerical study on the influence of small underground cavities for estimation of slope safety factor (소규모 지하공동이 사면안전율 산정에 미치는 영향에 관한 수치해석 연구)

  • An, Joon-Sang;Kang, Kyung-Nam;Song, Ki-Il;Kim, Byung-Chan
    • Journal of Korean Tunnelling and Underground Space Association
    • /
    • v.21 no.5
    • /
    • pp.621-640
    • /
    • 2019
  • Quantitative stability assessment of underground cavities can be presented as a factor of safety based on the Shear Strength Reduction Method (SSRM). Also, SSRM is one of the stability evaluation methods commonly used in slope stability analysis. However, there is a lack of research that considers the relationship between the probability of occurrence of cavities in the ground and the potential failure surface of the slope at the same time. In this study, the effect of small underground cavities on the failure behavior of the slope was analyzed by using SSRM. Considering some of the glaciology studies, there is a case that suggests that there is a cavity effect inside the glacier in the condition that the glacier slides. In this study, the stability evaluation of underground cavities and slope stability analysis, where SSRM is used in geotechnical engineering field, was carried out considering simultaneous conditions. The slope stability analysis according to the shape and position change of underground cavities which are likely to occur in the lower part of a mountain road was analyzed by using SSRM in FLAC3D software and the influence of underground cavities on the slope factor of safety was confirmed. If there are underground cavities near slope potential failure surface, it will affect the calculation of a factor of safety. The results of this study are expected to be basic data on slope stability analysis with small underground cavities.

Proposed Reduction Factor of Cyclic p-y Curves for Drilled Shafts in Weathered Soil (풍화토 지반에 근입된 현장타설말뚝의 Cyclic p-y 곡선의 감소계수 제안)

  • Kim, Byung-Chul;Jeong, Sang-Seom;Ko, Jun-Young
    • Journal of the Korean Geotechnical Society
    • /
    • v.31 no.2
    • /
    • pp.47-63
    • /
    • 2015
  • A fundamental study of drilled shafts subjected to lateral cyclic loading in weathered soil was carried out based on field tests and numerical analysis. The emphasis was given on quantifying the cyclic p-y curve function from lateral cyclic loading tests and three-dimensional finite element analysis. Lateral cyclic loading tests and three-dimensional finite element analysis were carried out to investigate the behavior of drilled shafts according to the direction of cyclic loading. Based on the field tests and numerical analysis, a modified lateral load transfer relationship and design chart with degradation factors were proposed by considering the characteristics of cyclic loading. It was found that the prediction by the proposed p-y curve function is in good agreement with the general trends observed by in-situ measurements, and it represents a practical improvement in the prediction of lateral displacement and bending moment distribution of drilled shafts subjected to cyclic loading.