• 제목/요약/키워드: Field Measurement

검색결과 5,055건 처리시간 0.037초

평행판 전극과 전기장 센서를 이용한 교류 고전압 발생원의 측정범위 확장기술 개발 (Development for Measurement Range Extension Technique of AC High Voltage Source using Parallel Plates Electrode and Electric Field Sensor)

  • 강전홍;류제천;이상화;김규태;김명수;한상옥;정재갑
    • 대한전기학회논문지:전기물성ㆍ응용부문C
    • /
    • 제55권9호
    • /
    • pp.446-451
    • /
    • 2006
  • The output voltage value of AC high voltage source has been usually measured by employing the high voltage divider of inductive or capacitive type. In the study, we have developed a new method for measuring the output voltage up to 60kV using parallel plates electrode and electric field sensor, which are constructed by home-made. Unlikely the conventional method using a high voltage divider, this developed method makes it possible to extend the range of output voltage from known low voltage measurement to high voltage measurement. From the linearity measured between electric field and applied voltage in the output voltage range of 1kV-30kV, the output voltage value up to 60kV can be obtained by the electric field measurement using the electric field sensor. The output voltage value obtained using the method is consistent with that obtained using high voltage divider within corresponding uncertainties.

음장의 공간적 변환기법을 이용한 타이어 구조 진동 소음 측정 (Measurement of Tire Structural Vibration Noise Using Spatial Transformation of Sound Field Technique)

  • 김병삼
    • 한국음향학회지
    • /
    • 제14권5호
    • /
    • pp.11-19
    • /
    • 1995
  • 본 논문에서는 불규칙한 노면이 설치된 섀시 동력계(chassis dynamometer)로 부터 가진된 타이어의 구조 진동 소음을 음장의 공간적 변환기법을 이용하여 측정하였다. 음장의 공간적 변환기법은 소음원으로 부터 원거리까지의 전파를 계산하는 기법이다. 즉, 한평면의 음향 측정으로 부터 측정 평면에서 멀리 떨어지거나 더 가까운 평면에서의 음장을 표현하는 변수들인 음압, 음향 인텐시티, 입자속도 등을 계산한다. 측정 평면에서 음원쪽으로 가까운 평면의 계산은 관접음장 홀로그래피를 적용하여 계산하고 먼 쪽은 헬름흘쓰 적분식을 적용한다 측정결과로 부터 타이어 구조 진동 소음의 방사형태와 소음원의 위치를 예측하였다.

  • PDF

2차원 구조물의 진동 인텐시티 계측에 대한 연구 (A Study on Structural Intensity Measurement of 2-dimensional Structure)

  • 이덕영;박성태
    • 소음진동
    • /
    • 제7권3호
    • /
    • pp.477-488
    • /
    • 1997
  • In order to control vibration in structures, it is desirable to be able to identify dominant paths of vibration transmission from sources through the structure to some points of interest. Structural intensity vector(power flow per width of cross section) using cross spectra is able to measure the vibration power flow at a point in a structure. This paper describes the structural intensity measurement of 2-dimensional structure. Structural intensity of 2-dimensional structure can be obtained from eight point cross spectral measurement per axis, or two point measurement per axis on the assumption of far field. Approximate formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained on an infinite plate at the near and far field in flexural vibration. The measurement error of two point measurement is rather bigger than eight point measurement on account of the assumption that Poisson's ratio is 1. The structural intensity vectors on the plate are checked the ability to identify the path of vibration power flow in random excitation and 200Hz sine excitation, the result of two point measurememt is almost the same as the result of eight point measurement in 200Hz sine excitation.

  • PDF

현장실측에 의한 메시(Mesh)접지저항 출정기법 연구 (A Study on the Measurement Technique of the Grounding Mesh Resistance by Field Measurements)

  • 한기붕;김삼수;정세중;이상익
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 1999년도 춘계학술대회 논문집
    • /
    • pp.426-429
    • /
    • 1999
  • In this paper, we have provided the measurement technique of the grounding mesh resistance by field measurements. The standard of measurement is specified in the IEEE Std 81.2-1991 and JEAC 5001-1988, which is the the fall-of-potential method by test-current injection, but this method is difficult to apply at field, where is small around a electric power substation of domestic. For the convenient measurement method, space of assistant probe and quantity of test-current injection are changed step for step. As the result, ' the proposed measurement technique of grounding mesh resistance is that the space of current and potential probes must be fixed at 150rn from a grounding mesh, the test-current injection has to keep 5A or more.

  • PDF

Realization of High Precision Position Measurement System Using M-sequence Encoded Laser Beam Scanning

  • Takayama, Jun-ya;Shinji Ohyama;Akira Kobayashi
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.107.5-107
    • /
    • 2001
  • In this report, as the active position measurement system, a new method for two-dimensional position measurement system using a concept of semi-open type signal field has proposed. The feature of this system is realizing a position measurement only by scanning the encoded laser beams from scanning points to a measurement field, and observed it. First, both system configuration and encoding method are considered concretely, and M-sequence signal is selected for encoding. Next system design is performed to realize the theoretical measurement accuracy, and applied to a position measurement experiments. Experimental results show that measurement precision is larger than theoretical values. Furthermore, method for improving the measurement ...

  • PDF

Stereo-PIV/LIF의 속도장과 농도장 동시측정 기법을 이용한 러쉬톤 교반기내 난류특성에 관한 연구 (A Study on the Turbulent Characteristics of Rushton Turbine Mixer by Simultaneous Measurement of Velocity and Concentration field with Stereo-PIV/PLIF Technique)

  • 민영욱;김윤기;김경천
    • 대한기계학회논문집B
    • /
    • 제28권3호
    • /
    • pp.365-370
    • /
    • 2004
  • Simultaneous measurement with PLIF(Planar Laser-Induced Fluorescence) and Stereo-PIV(Stereo Particle Image Velocimetry) was performed to investigate the structural characteristics of flow field in Rushton Turbine Mixer. Instantaneous 3D velocity fields are measured by two 2K${\times}$2K CCD cameras focused on an object plane with the angular displacement methods while the concentration fields are obtained through the measurement of the fluorescence intensity of Rhodamine B tracer excited by the second pulse of Nd:Yag laser light. Image distortion due to the camera view-angle is compensated by a mapping function. Finally, the spatial structures of turbulent flow around Rushton turbine were identified by the calculation of synchronized data of the velocity field and concentration field.

CDMA 필드 엔지니어링 시스템 개발 (Development of a CDMA Field Engineering System)

  • 이찬수;임희경;홍성철;임재봉;성영락;오하령
    • 한국정보처리학회논문지
    • /
    • 제7권5호
    • /
    • pp.1500-1510
    • /
    • 2000
  • In this paper, a CDMA (Code Division Multiple Access) field engineering system is designed and implemented for managing cellular telecommunication base stations. For high quality of CDMA service, optimized cell planning is crucial. For such cell planning, base stations must be managed based on analysis of CDMA field dta. The proposed system consists of two modules: a measurement module and au analysis of CDMA field dta. eh proposed system consists of tow modules; a measurement module and an analysis module. The measurement module collects various CDMA field dta and displays them on a vector map in a real-time manner. The analysis module associates measured data with various related information, e.g. base station information, and process them statistically. The proposed system can drastically reduce base station management cost.

  • PDF

초고층건물의 기둥축소량 예측, 계측 및 보정 (Prediction, Field Measurement and Compensation of Column Shortening in Tall Building)

  • 조석희;김한수;김도균
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2003년도 학술.기술논문발표회
    • /
    • pp.143-146
    • /
    • 2003
  • Tall Buildings have been popular in recent years. Tall buildings require special consideration to design and construction due to their structural features. Column shortening is one of the important technologies to be considered in. The long-term deformations of concrete cause vertical shortening on cores and columns, trigger deformations on cladding, partitions and finishes, and damage their serviceability. This also affects structural stability by inducing unexpected stress to the structural members such as outrigger. The main objective of this paper is to re-evaluate column shortening according to revised field information and to compare the analysis results with the actual field measurement. Mok-Dong Hyperion, a 69-story apartment building which is currently under construction, was chosen for the case study.

  • PDF

위상도플러 유속계를 이용한 계측에 있어서의 화염에 기인한 오차의 평가 (The evaluation of error due to flame in the measurement using phase doppler anemometry)

  • 양영준
    • 센서학회지
    • /
    • 제14권5호
    • /
    • pp.313-321
    • /
    • 2005
  • Spray combustion has been used in many industrial fields, for instance, such as diesel engines, gas turbines and industrial furnaces, and furthermore various measurement techniques have been applied to elucidate the phenomenon of spray combustion. In order to measure simultaneously the droplet velocity and the droplet size of spray, phase doppler anemometry (PDA) was frequently used in spray combustion. However, the measurement error is occurred due to existence of flame, which is considered as influencing the precision of measurement. Therefore, the purpose of this study is experimentally to conduct the systematic evaluation on the measurement error when PDA measurement is applied to combustion field.

열감지인광온도계를 이용한 물에 잠긴 물체 표면 온도장의 비접촉식 측정에 관한 연구 (A Study on Non-contact Surface Temperature Field Measurement of a Body Immerged in Water Using Thermographic Phosphor Thermometry)

  • 박윤성;차이타오;김경천
    • 한국가시화정보학회지
    • /
    • 제18권3호
    • /
    • pp.61-68
    • /
    • 2020
  • Thermographic phosphor (TP) thermometry is a noncontact optical measurement method and has been applied in many fields such as combustion and heat transfer. However, due to the limitation of bonding technology and measurement method, most TP thermometry studies were conducted only on the air environment with water-soluble binders. In this paper, a temperature measurement technology in water using TP is proposed by coatings of manganese activated magnesium fluorogermanate (Mg4FGeO6:Mn4+, MFG) with Polydimethylsiloxane (PDMS). Four MFG-PDMS coatings with different thicknesses were prepared. The lifetime of MFG was not affected by the thickness of the coating as a result of the experiment and analysis of phosphor intensity using a photomultiplier tube. To measure the surface temperature field of an immerged body in water, a cylinder-type cartridge heater was coated with MFG doped PDMS. Transient surface temperature field was successfully measured even the initial temperature is higher than the boiling point of water.