• Title/Summary/Keyword: Field Measurement

Search Result 5,067, Processing Time 0.036 seconds

Evaluation on bridge dynamic properties and VIV performance based on wind tunnel test and field measurement

  • Yang, Yongxin;Ma, Tingting;Ge, Yaojun
    • Wind and Structures
    • /
    • v.20 no.6
    • /
    • pp.719-737
    • /
    • 2015
  • Full scale measurement on the structural dynamic characteristics and Vortex-induced Vibrations (VIV) of a long-span suspension bridge with a central span of 1650 m were conducted. Different Finite Element (FE) modeling principles for the separated twin-box girder were compared and evaluated with the field vibration test results, and the double-spine model was determined to be the best simulation model, but certain modification still needs to be made which will affect the basic modeling parameters and the dynamic response prediction values of corresponding wind tunnel tests. Based on the FE modal analysis results, small-scaled and large-scaled sectional model tests were both carried out to investigate the VIV responses, and probable Reynolds Number effects or scale effect on VIV responses were presented. Based on the observed VIV modes in the field measurement, the VIV results obtained from sectional model tests were converted into those of the three-dimensional (3D) full-scale bridge and subsequently compared with field measurement results. It is indicated that the large-scaled sectional model test can probably provide a reasonable and effective prediction on VIV response.

Study on the Tx/Rx Beam Performance of Planar Active Phased Array Antenna for Airborne as using the Near-field Measurement (근접전계 시험을 이용한 항공기용 평면형 능동 위상 배열 안테나 송수신 빔 성능 검증에 관한 연구)

  • Kim, Young-Wan;Lee, Jaemin;Lee, Yuri;Kim, JongPhil;Park, Jong-Kuk;Park, Kyuchul;Kim, Sunju
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.1
    • /
    • pp.61-68
    • /
    • 2018
  • In this paper, we described about methods and results to verify the Tx/Rx beam characteristics of a planar active phased array antenna as using a near-field measurement. The near-field system can effectively measure multiple beams and predict the performance degradation due to the partial failure of individual elements. Also, it can accurately predict the EIRP relating to detection performance of the active phased array radar. We briefly described the near-field measurement method to verify the Tx/Rx beam characteristics, and then verified the effectiveness of measurement method by analyzing the measured results.

The Conceptual Design of High-Tc superconducting Magnet for a Superconducting Property Measurement System (초전도 특성평가장치용 고온 초전도 마그네트의 개념 설계)

  • Choi, S.J.;Lee, S.Y.;Bae, J.H.;Sohn, M.H.;Kim, W.S.;Park, C.;Lee, J.K.;Lee, S.J.;Choi, K.
    • Progress in Superconductivity and Cryogenics
    • /
    • v.11 no.1
    • /
    • pp.20-24
    • /
    • 2009
  • The superconducting property measurement system is used to acquire electrical and thermal properties on short HTS tape samples and the system is composed of specimen holder for mounting HTS tape and a magnet for applying magnetic fields externally. The magnet consists of two split racetrack windings and is designed to produce maximum 3T of center field. The temperature of specimen holder can be varied in range from 10K to 77K. The field homogeneity is required less than 300 gauss stray field contour within 20cm axially and 3cm radially from origin. We have worked on the conceptual designs of the conduction-cooled magnet for the superconducting characteristic measurement system. The measurement system will be fabricated in near future based on the design parameters presented in this paper.

NEAR=FIELD DIFFRACTION PATTERN BY A SPHERICAL AIR CAVITY IN A DIELECTRIC MEDIUM (유전체 매질내에 있는 구형공동에 의한 근거리 회절패턴)

  • 강진섭;라정웅
    • Journal of the Korean Institute of Telematics and Electronics A
    • /
    • v.32A no.2
    • /
    • pp.19-30
    • /
    • 1995
  • Diffraction patterns of the copolarized and the crosspolarized total electric fields by a spherical air cavity in a dielectric medium are analyzed in the forward near-field region when the wavelength of the incident plane wave is comparable to one half of the cavity radius. It is shown that double nulls and dips of the copolarized and the crosspolarized total electric fields exist in the measurement plane tansverse to the propagating direction of the incident field, and their dependences on the frequency, the distance of the measurement plane, and the measurement angle are analyzed.

  • PDF

Field Measurement of Hydration Heat and Field Aaaplication of Pipe Cooling System (수화열 계측 및 파이프쿨링 시공 사례)

  • 최계식;양주경;최영돈;최고일
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1994.10a
    • /
    • pp.381-386
    • /
    • 1994
  • Recently, the design and construction of massive concrete structures are increased. But, the temperature rise within a large concrete mass make the construction of massive concrete structures be very difficult. Therefore, in Seohae Grand Bridge Project, the field measurement of hydration heat for the massive concrete footings(11$\times$22$\times$4m) was carried out. It was shown to be possible to construct the massive concrete footing successfully by application of pipe cooling system. And the measurement results showed that standard code for concrete practice was very conservative.

  • PDF

Industrial Applications of PIV/PTV Velocity Field Measurement Techniques

  • Lee Sang Joon
    • 한국가시화정보학회:학술대회논문집
    • /
    • 2001.12a
    • /
    • pp.23-35
    • /
    • 2001
  • Due to advances in digital image processing, computer and optical hardware, it is possible to extract full flow information from visualized flow images. Recently, the PIV/PTV methods have been accepted as a reliable velocity field measurement technique. In my laboratory, several velocity field measurement techniques have been developed and they were applied to various thermo-fluid flow problems. In this paper, some of the industrial applications will be discussed. As a result, the PIV/PTV technique was proved to be a powerful tool for industrial fluid flow diagnosis.

  • PDF

Review of SQUID Sensors for Measuring Magnetocardiography (심자도 측정을 위한 SQUID 센서 기술의 개발 현황)

  • Lee, Y.H.;Kim, J.M.;Yu, K.K.;Kim, K.;Kwon, H.
    • Progress in Superconductivity
    • /
    • v.13 no.1
    • /
    • pp.1-6
    • /
    • 2011
  • Measurement of magnetic signals generated from electric activity of myocardium provides useful information for the functional diagnosis of heart diseases. Key technical component of the magnetocardiography (MCG) technology is SQUID. To measure MCG signals with high signal-to-noise ratio, sensitive SQUID magnetic field sensors are needed. Present magnetic field sensors based on Nb SQUIDs have field sensitivity good enough to measure most of MCG signals. However, for accurate measurement of fine signal pattern or detection of local atrial fibrillation signals, we may need higher field sensitivity. In addition to field sensitivity, economic aspect of the SQUID system is also important. To simplify the SQUID readout electronics, the output voltage or flux-to-voltage transfer of SQUID should be large enough so that direct measurement of SQUID output can be done using room-temperature preamplifiers. Double relaxation oscillation SQUID (DROS), having about 10 times larger flux-to-voltage transfers than those of DC-SQUIDs, was shown to be a good choice to make the electronics compact. For effective cancellation of external noise inside a thin economic shielded room, first-order axial gradiometer with high balance, simple structure and long-baseline is needed. We developed a technology to make the axial gradiometer compact using direct bonding of superconductive wires between pickup coil and input coil. Conventional insert has mechanical support to hold the gradiometer array, and the dewar neck has equal diameter with the dewar bottom. Boiling of the liquid He can generate mechanical vibrations in the gradiometer array due to mechanical connection structure. Elimination of the mechanical support, and direct mounting of the gradiometer array into the dewar bottom can reduce the dewar neck diameter, resulting in the reduction of liquid He consumption.

Construction of the Measuring System for Magnetic Field Waveform Associated with Lightning Return Strokes. (낙뢰에 의하여 발생되는 자계파형측정 시스템의 구성)

  • Lee, B.H.;Ha, B.C.;Kil, G.S.;Paek, Y.H.;Lee, Y.K.
    • Proceedings of the KIEE Conference
    • /
    • 1994.07b
    • /
    • pp.1658-1660
    • /
    • 1994
  • This paper describes the measurement system of the magnetic field waveforms generated by lightning return strokes. The frequency bandwidth of magnetic field measurement system is from 270[Hz] to about 2.3 [MHz]. As the application experiment, the magnetic field generated by simple impulse and oscillating impulse currents, which are measured by a current transformer (Tek. AM503), is observed by the trial magnetic field measurement system. The obtained results are agreement with each other. A typical magnetic field waveform associated with lightning return strokes was recorded and presented.

  • PDF

Evaluation of Field Calibration Test on Rail for Train Wheel Force Measurement

  • Sim, Hyoung-Bo;Yeo, Inho
    • International Journal of Railway
    • /
    • v.8 no.1
    • /
    • pp.1-4
    • /
    • 2015
  • An accurate measurement of the train-track interaction forces is important for track performance evaluation. In the field calibration test as a wheel load measurement process, the calibration system creates a different boundary condition in comparison with that in the train wheel passage. This study aims to evaluate a reliability of the field calibration test in the process of wheel load measurement. Finite element models were developed to compare the deformed shapes, bending moment and shear force profiles on the rail section. The analysis results revealed that the deformed shapes and their associated bending moment profiles on the rail are significantly different in two numerical simulations of the calibration test and the train wheel load passage. However, the shear stress profile on the rail section of the strain gauge installation in the field was almost identical, which may imply that the current calibration test is sufficiently reliable.

Development of an Integrated Measurement and Analysis System for DTV Field Test (DTV 필드테스트를 위한 통합 측정 및 분석 시스템 개발)

  • Kim Young-Min;Suh Young-Woo;Mok Ha-Kyun;Kwon Tae-Hoon;Lee Sang-Gil
    • Journal of Broadcast Engineering
    • /
    • v.10 no.4 s.29
    • /
    • pp.599-609
    • /
    • 2005
  • There are many test parameters in the DTV measurement, which uses several test measuring instruments and miscellaneous devices. To operate all of those devices and analyse test results is a tedious and time-consuming process with a high error rate committed by inexperienced test crews. In this paper, we propose an integrated DTV measurement and analysis system(IMAS) that remotely controls and manages any instruments with standard network interface. This system can take, organize, store the field data into an integrated database and easily produce systematic output according to user-defined form. It can also measure several types of digital broadcasting signals such as DTV, DMB, DAB with generalized measurement procedures. Proposed measurement system was applied in the DTV field test by KBS and proved that it could enhance the accuracy and efficiency of entire test sequences and also dramatically reduce measurement time compared to conventional measurement systems.