• Title/Summary/Keyword: Field Intensity

Search Result 1,925, Processing Time 0.033 seconds

External Magnetic Field of Journal Bearing with Twined Solenoid

  • Zhang, Yanjuan;Wang, Jianmei;Li, Decai
    • Journal of Magnetics
    • /
    • v.22 no.2
    • /
    • pp.291-298
    • /
    • 2017
  • In this paper, the distribution of internal magnetic induction intensity of oil-film bearing twined solenoids was proposed. The magnetic field was generated by solenoids and magnetized bearing. The magnetized bearing was simplified as solenoid model. The mathematical model of magnetic induction intensity at any point of finite solenoid was deduced. Through experiment method, the distribution of the internal magnetic induction intensity of oil-film bearing and the magnetizing current formula of bearing was obtained. Further, the magnetic induction intensity distribution of magnetization bearing was solved successfully. The results showed that the magnetic induction was a second-degree parabola with open upwards along the axial plane and the distribution of magnetic induction intensity was opposite to the rule of magnetic induction intensity generated by solenoids. In addition, the magnetic flux density increased linearly with the increase of current.

Effect of Electric Fields on Flame Speed of Propagating Premixed Flames in Tube (전기장이 튜브내 예혼합화염 전파속도에 미치는 영향에 관한 연구)

  • Ryu, S.K.;Won, S.H.;Cha, M.S.;Chung, S.H.
    • 한국연소학회:학술대회논문집
    • /
    • 2006.04a
    • /
    • pp.137-143
    • /
    • 2006
  • The effect of electric fields on flame speed has been investigated experimentally by observing propagating premixed flames in a tube for methane/air mixtures. The flame speeds were measured in both the normal and micro gravity conditions to substantiate the measurements. The results show that the flame speeds were enhanced by both the AC and DC electric fields, as the flame approached to the high voltage electrode located on the one end of the tube. The enhancement of flame speed was proportional to the square root of the electric field intensity, defined as the voltage applied divided by the distance of flame from the high voltage electrode, when the electric field intensity is sufficiently large. When the electric field intensity was low, there existed critical intensities, below which the electric fields did not influence the flame speed. This critical electric field intensity correlated well with the flame speed.

  • PDF

An Effect of Magnetic Field on VDT Work (VDT 작업시 자기장이 인체에 미치는 영향에 관한 연구)

  • 박재희;김철중;이남식;김진호
    • Proceedings of the ESK Conference
    • /
    • 1992.10a
    • /
    • pp.77-83
    • /
    • 1992
  • The effect of magnetic field on VDT work has not been clarified yet, but many studies repoerted that magnetic field could cause of the cancers. Many developed countries have set the criteria of magnetic field and produce the VDT which has lower magnetic value. The purpose of this study was to measure the intensity of magnectic field from VDT. For this purpose three experiments were performed. The first was designed to measure the intensity of magnetic field by distances(30,60,90 cm) and directions. The second was to compare the intensities between VDT and Color TV. The last was to evaluate the eye protec- tion glasses. The reults showed that the intensity of magnetic field was lowered in proportion to the distance $r^{3}$and both lateral sides of the VDT marked high values compared to the frontal and back sides. On the same distance (30 cm) color TV marked high value to the VDT. But on the normal work distance (TV: 100 cm, VDT: 30 cm) there was little difference, Eye protection glasses could not protect the magnetic field physically.

  • PDF

Terahertz Spectral Characteristics of Electrolyte Solutions under Different Magnetic Fields

  • Shao, Siyu;Huang, Haiyun;Peng, Bo;Wang, Guoyang;Ye, Ping;Wang, Jiahui;Su, Bo;Cui, Hailin;Zhang, Cunlin
    • Current Optics and Photonics
    • /
    • v.6 no.3
    • /
    • pp.337-343
    • /
    • 2022
  • Microfluidic chips are new devices that can manipulate liquids at the micrometer level, and terahertz (THz) time-domain spectroscopy has good applicability in biochemical detection. The combination of these two technologies can shorten the distance between sample and THz wave, reduce THz wave absorption by water, and more effectively analyze the kinetics of biochemical reactions in aqueous solutions. This study investigates the effects of different external magnetic field intensities on the THz transmission characteristics of deionized water, CuSO4, CuCl2, (CH3COO)2Cu, Na2SO4, NaCl, and CH3COONa; the THz spectral intensity of the sample solutions decrease with increasing intensity of the applied magnetic field. Analysis shows that the magnetic field leads to a change in the dipole moment of water molecules in water and electrolyte solutions, which enhances not only the hydrogen-bond networking ability of water but also the hydration around ions in electrolyte solutions, increasing the number of hydrogen bonds. Increasing the intensity of this magnetic field further promotes the hydrogen-bond association between water molecules, weakening the THz transmission intensity of the solution.

Mode I Field Intensity Factors of Infinitely Long Strip in Piezoelectric Media

  • Kwon, Soon-Man;Lee, Kang-Yong
    • Journal of Mechanical Science and Technology
    • /
    • v.14 no.8
    • /
    • pp.845-850
    • /
    • 2000
  • We consider the problem of determining the singular stresses and electric fields in a piezoelectric ceramic strip containing a Griffith crack under in-plane normal loading within the framework of linear piezoelectricity. The potential theory method and Fourier transforms are used to reduce the problem to the solution of dual integral equations, which are then expressed to a Fredholm integral equation of the second kind. Numerical values on the field intensity factors are obtained, and the influences of the electric fields for PZT-6B piezoelectric ceramic are discussed.

  • PDF

A study on the Measurement of Field Transmission Loss through Doors in Buildings Using the Surface Intensity Method. (Surface Intensity 법에 의한 건물내 출입문의 차음성능 현장측정에 관한 연구)

  • 손장열;오재응;김흥식
    • The Journal of the Acoustical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.3-12
    • /
    • 1985
  • The surface intensity method is a relatively new tool which can identify the noise source or path and measure the radiation power. One microphone and one accelerometer are used in this new technique. In this study, this new technique has been used to measure the field transmission loss trough doors. The results of the experiment indicate that the surface intensity method produces reliable data and can be applied to the transmission loss measurement.

  • PDF

A study on the Measurement of Field Transmission Loss through Doors in Buildings Using the Surface Intensity Method. (Surface Intensity 법에 의한 건물내 출입문의 차음성능 현장측정에 관한 연구)

  • Son, Jang Yeol;O, Jae Eung;Kim, Heung Sik
    • The Journal of the Acoustical Society of Korea
    • /
    • v.4 no.2
    • /
    • pp.3.1-3.1
    • /
    • 1985
  • The surface intensity method is a relatively new tool which can identify the noise source or path and measure the radiation power. One microphone and one accelerometer are used in this new technique. In this study, this new technique has been used to measure the field transmission loss trough doors. The results of the experiment indicate that the surface intensity method produces reliable data and can be applied to the transmission loss measurement.

A Study on Structural Intensity Measurement of 2-dimensional Structure (2차원 구조물의 진동 인텐시티 계측에 대한 연구)

  • 이덕영;박성태
    • Journal of KSNVE
    • /
    • v.7 no.3
    • /
    • pp.477-488
    • /
    • 1997
  • In order to control vibration in structures, it is desirable to be able to identify dominant paths of vibration transmission from sources through the structure to some points of interest. Structural intensity vector(power flow per width of cross section) using cross spectra is able to measure the vibration power flow at a point in a structure. This paper describes the structural intensity measurement of 2-dimensional structure. Structural intensity of 2-dimensional structure can be obtained from eight point cross spectral measurement per axis, or two point measurement per axis on the assumption of far field. Approximate formulation of the relation between bending waves in structures and structural intensity makes it possible to separate the wave components by which one can get a state of the vibration field. Experimental results are obtained on an infinite plate at the near and far field in flexural vibration. The measurement error of two point measurement is rather bigger than eight point measurement on account of the assumption that Poisson's ratio is 1. The structural intensity vectors on the plate are checked the ability to identify the path of vibration power flow in random excitation and 200Hz sine excitation, the result of two point measurememt is almost the same as the result of eight point measurement in 200Hz sine excitation.

  • PDF

On the reducing methods of Electromagnetic Field Penetration through Apertures in Cavity (개구를 갖는 공동의 침투 전자계 감소 방법에 관하여)

  • 황보승;김기채
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 1999.11a
    • /
    • pp.106-109
    • /
    • 1999
  • The problem of electromagnetic field through apertures in cavity has been theoretically and experimentally investigated. The electric field intensity has been theoretically evaluated by the method of moments. Experiment results are some different from numerical simulation about the magnitude of electric field intensity, But The form of electric field intensity distributions In cavity is similar to numerical simulation. Reactance-loaded method for reducing electric field penetration In cavity by external sources is used In this paper.

  • PDF

Computer simulation of electric field distribution in FALC process (FALC 공정에서의 전계 분포 전산모사)

  • 정찬엽;최덕균;정용재
    • Journal of the Korean Crystal Growth and Crystal Technology
    • /
    • v.13 no.2
    • /
    • pp.93-97
    • /
    • 2003
  • The crystallization behavior of amorphous silicon is affected by direction and intensity of electric field in FALC(Field-Aided Lateral Crystallization). Electric field was calculated in a simplified model using conductivity data of Mo, a-Si, $SiO_2$and boundary conditions for electric potential at the electrodes. The magnitude of electric field intensity in each corner of cathode was much larger than that in the center of patterns, and the electric field direction was 50~60 degree outside to cathode. And electric field intensity at a relatively small pattern was larger than that of a large pattern.