• Title/Summary/Keyword: Field Installation

Search Result 1,199, Processing Time 0.03 seconds

Error-Preventing Monitoring System using RFID in the Mixed-Model Automotive Parts Assembly Line (혼합형 모델 자동차부품 조립라인에서의 RFID를 이용한 오류방지 모니터링시스템)

  • Koo, Ja-Rok
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.10 no.12
    • /
    • pp.3863-3869
    • /
    • 2009
  • In recent years, globalization of markets and increased consumer sophistication in automotive industry have led to an increase in the variety of products and a consequent increase in the number of variants of any given product line that a manufacturer must supply. Also, the modularity trend of automotive production systems greatly affects on the production systems of automotive parts suppliers. These typically requires the implementation of cost efficient, flexible production systems, so called mixed-model assembly lines. We studied the problems of mixed-model assembly and assembly error-preventing techniques, and developed the error-preventing monitoring system using RFID in the mixed-model automotive parts assembly line. Especially, this study aimed to solve the problems and supplement the existing systems for preventing assembly errors, by developing a monitoring system using RFID to minimize the issues currently occurring in the field of automotive parts assembly, such as losses from incorrect installation and omission.

New Train Detection Method using DC Magnetic Field Variation (직류 자기장 변화를 이용한 새로운 열차검지기법 연구)

  • Shin, Seung-Kwon;Jung, Ho-Sung;Lee, Hyung-Chul;Park, Young;Cho, Yong-Hyeon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.9
    • /
    • pp.1324-1328
    • /
    • 2013
  • The reason of train location detection is generally the train interval control between the railway stations and the train path control in the railway station yard in order to avoid train collision. It is very important to know the train location for shortening the train headway, and improving the efficiency of railway maintenance as well as the safe operation of trains. Therefore, the accurate detection of train location is the prerequisite technology in railway signalling system. The track circuit and the wheel sensor of rolling stock have been used to detect the train location widely in urban railway as well as high speed train. The track circuit is continuously monitored by electrical equipment to detect the absence of the train and the tachometer and encoder is used for the wheel sensor to measure the train speed. But speed sensor failures are frequent due to the extremely harsh operating conditions encountered in rail vehicle. The CBTC(Communication based Train Control) system has been used in urban railway system recently. But the installation of CBTC system is very high and the modification of design is difficult. This paper deals with the feasibility of new train location detection method using magnetic sensors.

Development of EIS Evaluation Method about PEMFC 1kW STACK (가정용 연료전지 스택의 EIS 평가 기법 개발)

  • Park, Chaneom;Han, Woonki;Jung, Jinsu;Ko, Wonsik
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2011.05a
    • /
    • pp.100.1-100.1
    • /
    • 2011
  • Electrochemical impedance spectroscopy(EIS) are using widely as a useful technique mainly in the field of electrochemical for the analysis of electrode reactions or characteristics of the composites. The response analysis of the systems technique provides comprehensive informations about the characteristic and structure of complex and internal reaction. The EIS is the method to measure impedance of the measurement target classified by the frequency, it select the equivalent impedance model to give same response from the result and it calculate the parameter. Therefore, the chemical reaction inside the fuel cell is to modeling to electrical impedance. And as repeating the same experiment in each of the operating point, we can get each different parameter. As a result, we can establish the equivalent impedance model in each operating point. Therefore, if we use these models, we can evaluate the fuel cell without the internal design parameter of the fuel cell as required in existing modeling. The EIS is used typically technique for distinguish status of fuel cell called SOH(State Of Health). When the fuel cell is degradation, Efficiency and health of the fuel cell is reduced because internal impedance is increase. As usage of these principles, we can evaluate state of fuel cell through the impedance analysis of fuel cells. In this study, we are presents EIS distinction system and algorithm for residential fuel cell systems. At the time of the fuel cell installation in the fields, the EIS system and proposed algorithm will be able to apply as technique for efficiency and performance evaluation about fuel cell system.

  • PDF

A Study on Construction and Applicability on of Smart Pole Measuring System for Monitoring Steep Slope Sites (급경사지 모니터링을 위한 스마트폴 계측시스템 구축 및 적용성 연구)

  • Lee, Jin-Duk;Chang, Ki-Tae;Bhang, Kon-Joon
    • Journal of Korean Society of Disaster and Security
    • /
    • v.7 no.2
    • /
    • pp.1-8
    • /
    • 2014
  • Smart Pole Measurement System was constructed with not only the core sensors of a GNSS receiver, a TRS sensor and a soil moisture sensor but supplementary installation of power supply and radio communication for monitoring steep slope sites. Also a data processing software for displacement extraction and visualization was developed. Smart Pole Measurement sensor is composed of a GNSS antenna at the top of the pole, a TRS sensor and a gyro sensor vertical below right of the antenna and a soil moisture sensor at the bottom of the pole. The sensor combination extracts not only ground combination in real time but transltion, slide, settlement and soil moisture content. This measuring/monitoring system which cosists of data receiving part, data collection/transfer part and data processing part was built to exercise their functions and then test measuring/monitoring was conducted by introducing artificial displacement and the results were analyzed to evaluate field applicability.

An Empirical Study on Critical Success Factors in Implementing ERP System (ERP시스템 구축단계 별 주요성공요인에 관한 실증적 연구)

  • 김상훈;최광돈
    • Journal of the Korean Operations Research and Management Science Society
    • /
    • v.26 no.4
    • /
    • pp.1-21
    • /
    • 2001
  • The purpose of this stuffy is to derive critical success factors for ERP system implementation by integrating managerial, technical. human resource and organizational culture factors welch have been proposed as influencing factors for the performance of ERP system implementation in previous studios. Especially, this stuffy divides ERP system implementation process into preparation stave, implement stage and settle-down and stabilization stave, and then derives critical success factors in each stage. The data for empirical analysis of the research model are collected from 64 companies and the respondents for questionnaire consist of ERP system implementation project managers and user department managers in companies which have already operated it after ERP system installation. The main results of this study are as follows. First, it derives 27 success factors through comprehensive review of various factors which may affect ERP system implementation performance, and categorizes them into one of three stapes preparation stave, implement stage, and settle-down and stabilization stage. Second, the relationship between many success factors at each stave (preparation stave, implement stage, and settle-down and stabilization stave) and performance variables is tested. As a result, the significant correlations between many success factors at each stage and ERP system implementation performance are found, and the difference among success factors in the degree of influencing the system performance is significantly shown. finally, the relationship between process-oriented performance variables and result-oriented performance ones is tested. As a result, it is found that there is significant correlation between process-oriented performance variables except for one variable-project resource management appropriateness - and result-oriented performance ones. The theoretical contribution of this study is to derive a comprehensive model of critical success factors for implementing ERP system project from the system deve1opment life cycle perspective, and empirically test it through field survey with a wide range of data collection. And, the practical implication of this study is to present the desirable guidelines for performing ERP system implementation project successfully.

  • PDF

A Study on the Development of Educational Programs for LNG Bunkering in Consideration of the Safety System

  • Han, Se-Hyun;Yun, Yong-Sup;Kim, Jong-Su;Lee, Young-Chan
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.22 no.3
    • /
    • pp.268-277
    • /
    • 2016
  • This paper aims at presenting bunkering educational programs for LNG fueled ship taking into consideration existing similar education programs and safety systems at the international level in order to enhance both seafarers' and vessels' safety. Heavy fuel oil has typically been used as fuel of ship propulsion. The competitiveness of the fuel oil is recently getting weak in terms of cost and environmental aspects. Liquefied natural gas is introduced for ship propulsion in the maritime field as a new energy source replacing heavy fuel oil. In order to prepare for installation and operation of LNG fueled propulsion ship on board, International Maritime Organization has discussed this subject for about 10 years. As a result of the discussion on such ships in IMO, the International Code of Safety for Ships Using Gases or Other Low-Flash-Point Fuels entered into force on the year 2015. International organizations and several countries therefore drives actively entire researches and other businesses with a view to providing equipment and system of LNG bunkering. The systems are divided into ship-to-ship transfer, terminal / pipeline-to-ship transfer and truck-to-ship transfer. By adopting transfer system of LNG bunkering, many human resources will be needed in these areas on scene as well as on managing, operating, trading, finance, design of LNG bunkering industries. LNG bunkering is just in the beginning stage. Hence, this paper reviews and proposes professional educational programs of LNG bunkering in consideration of technical aspects of the safety system of LNG bunkering based on the types of bunkering systems.

A Study on Realization of System in Wireless Location Awareness Technology Using Ubiquitous Active RFID (Active RFID를 이용한 실내 무선 위치 인식 기반 스마트 센서 빌딩 구현에 관한 연구)

  • Jung, Chang Duk
    • Journal of Intelligence and Information Systems
    • /
    • v.12 no.3
    • /
    • pp.83-93
    • /
    • 2006
  • This paper is wireless location awareness technology using RFID. We investigates the Location of the received Signal strength reported by RF Analyses of the data are performed to understand the underlying features of location fingerprints. The system is performed factors the extreme environmental Emit signal, which consists of a unique 5000 Terminals. The Location Service have become very popular in many service industries, purchasing and distribution logistics, industry, manufacturing companies and a parking place. The Technically optimal Solution would be the storage of Intelligence information in the most common form of electronic data-carrying device in use in everyday life is the smart card based upon a contact field (telephone smart card, bank cards). The method of an indoor positioning experiment system is compared using measured Location data and a charge of service. The result of research showed the following: first, to check out the mechanism between benefit of system installation and operation of Active RFID. Second, it contributed on indoor wireless location intelligence system efficiency.

  • PDF

Development of outage-free installation method and equipments for underground power distribution system (지중배전선로 무정전 공법의 최적화를 위한 장비 개발)

  • Yu, K.Y.;Joo, J.M.;Lee, Y.S.;Kim, Y.M.;Kang, N.K.
    • Proceedings of the KIEE Conference
    • /
    • 2005.11b
    • /
    • pp.122-124
    • /
    • 2005
  • Underground distribution system is a trend due to the successive development of metropolitan area and satellite cities and the environment of the commercial and residential areas. The high quality of electricity, which is related with the minimal outage duration time due to the maintenance work for the underground distribution line, is mandatory. Hence, the construction method and tools for the outage-free maintenance construction have been required for underground distribution system. So far, all the efforts for outage-free maintenance for the underground distribution have been limited only to the survey for foreign countries situation and the theoretical provision; thus, It is required to develop the various construction method and the application tools. Differently from the aerial line, the construction of the underground cable is complicated and the insulation distance between conductor and shield should be maintained in loadmaking/breaking operation, though the apparatus connected with cable is a deadfront type. Also since the apparatus is installed above ground, by-pass of faulted area at busy area needs a variety of high technologies. Therefore, in this these, the authors introduce the development status of the loadbreak connectors, connection facilities, outage-free maintenance system for secondary side, a secondary auxiliary bushing and additional tools so that there can be more progress on this field.

  • PDF

An Experimental Study to Evaluate the Subsidence Stability of Riprap Protection without Filters (필터 없는 사석보호공의 유사이탈로 인한 침하 안정성 평가를 위한 실험 연구)

  • Ji, Un;Yeo, Woon-Kwang;Lee, Won-Min
    • Journal of Korea Water Resources Association
    • /
    • v.41 no.4
    • /
    • pp.445-454
    • /
    • 2008
  • Many countermeasures for local scour at bridge piers constructed on the river and sea have been developed and researched to protect piers against local scour. The most commonly employed method is riprap protection, which is sometimes required the filter installation between riprap and base layers. However, the construction of stone filters are really hard to perform in the field, require the high cost, or sometimes are impossible. The experimental modeling is conducted to analyze the riprap failure modes and the stability of riprap protection without filters based on the different approach velocity and riprap layer thickness conditions. Also, the stability index to evaluate the performance of riprap protection is developed using the experimental results. The cover and thickness of the riprap layer play a very important role in the stability and thicker riprap layers can prevent a total disintegration of the riprap layer effectively, especially due to winnowing failure.

A Development of Wireless Monitoring System for Temperature Monitoring by using IR Sensor (적외선 센서를 이용한 열화상태 무선감시 시스템 개발)

  • Kim, Jihee;Kim, Sinwoo;Kang, Yongsoo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.1
    • /
    • pp.239-245
    • /
    • 2013
  • The temperature monitoring of power cable and cable junction point is the necessary link of the safe and reliable operation of the power system. Many kinds of cables and high voltage junction points are easy to exposed continuous vibrations and momentary impulse in industry field especially power plant industries. This system can predict the overheating of the electric cable interface and the possibility of all kinds of accident, and it helps for eliminating the hazards of electric cable interface and provides the effective guarantee for the safety operation. In order to avoid the faults of the inconvenience of installation and maintenance and the high cost of application, this system used small and contactless IR sensor module. The low power consumption is used in the system. The goal of this study is the low cost and on-line reliable monitoring of power cable and junction point temperature.