• 제목/요약/키워드: Field Installation

검색결과 1,203건 처리시간 0.023초

KJ 도로터널시설물의 고조파 실측 및 평가 (Harmonics Measurement of Evaluation of KJ Road Tunnel Installations)

  • 왕용필;김세동;유상봉
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.87-93
    • /
    • 2011
  • Nonlinear loads including lighting fixtures generate harmonic currents and create distortions on the sinusoidal voltage of the power system. Harmonic field measurements have shown that the harmonic contents of a waveform varies with time. A cumulative probabilistic approach is the most commonly used method to solve time varying harmonics. In this paper the time varying harmonics of lighting loads are evaluated by international harmonic standards(IEC 61000-3-6).

분산전원이 연결된 22.9[kV] 배전계통의 양방향 보호기기 실증시험 연구 (The Study on the Actual Examination of the Bidirectional Protection Device in the 22.9[kV] Distribution Power System Interconnected with the DG)

  • 이흥재;최명호
    • 조명전기설비학회논문지
    • /
    • 제25권10호
    • /
    • pp.102-108
    • /
    • 2011
  • The existing power flow has a single direction to the line end but the bidirectional power flow will possibly occur depending on the output capacity in the 22.9[kV] distribution power system connected with the dispersed generation(DG). So these characteristics would influence the power system management. The DG have many advantages such as assistance source, Load share etc. So the utility must apply the bidirectional protection system so as to maximize an advantage of DG. This paper describes the field test case of bidirectional protective device in order to investigate the device performance when applied to bidirectional power system. We have tested in the power system test site of KEPCO and these tests provide the basis for performance verification test of bidirectional protective device in the power system.

Measurement of UV radiation of LED lighting

  • Ku, Seong-Mo;Im, Jong-Min;Yi, Chin-Woo
    • 조명전기설비학회논문지
    • /
    • 제25권3호
    • /
    • pp.7-14
    • /
    • 2011
  • Many countries and researchers in the lighting field have focused on the LED light source as a solution to energy savings and environmental pollution. The LED light source consumes less power, has a long life and is highly economical. It is vibration and shock-resistant, and environment friendly as well. But LED lighting has some problems. In particular, the photobiological safety of LED light sources is emerging as an issue. Ultraviolet radiation from the LED light source emitted directly to the human body over a long period of time is harmful. In this paper, UV radiation from white LED was measured. Finally, the LED light source emits UV radiation, but it is relatively small when compared to others.

An Assessment of the Disability Glare by the Road Lighting System Installed on Guardrails

  • Seok, Dae-Il;Kim, Hoon
    • 조명전기설비학회논문지
    • /
    • 제24권3호
    • /
    • pp.1-7
    • /
    • 2010
  • To find an appropriate illuminance range for the disability glare caused by the road lighting system installed on guardrails, the influence of the disability glare was evaluated in comparison with the road lighting system of a streetlight. To test the disability glare, an indoor laboratory was constructed and a variation of luminance contrast threshold was evaluated. As a result, when the retinal illuminance was increased and glare sources existed within the narrow visual field, the luminance contrast threshold was increased. Although the road lighting luminaire was installed as low as the height of the guardrail on the road, when out of sight, the influence of the disability glare was small in comparison with the conventional road lighting system such as a streetlight.

과전류 부하에서 5상 농형 유도전동기의 정수 특성 (Parameters Estimation Characteristics of Five-Phase Squirrel-Cage Induction Motor within Over Current Load)

  • 김민회
    • 조명전기설비학회논문지
    • /
    • 제29권7호
    • /
    • pp.38-46
    • /
    • 2015
  • This paper propose a variable parameter estimations for variable over current load of five-phase squirrel-cage induction motor(IM) to servo control system. In order to high performance control of AC motor using a field oriented control(FOC) and direct torque control(DTC) algorithm, there are required precise motor parameters for slip calculation, flux observer, controller gain, torque command of current components, rotor position, speed estimation, and so on. We are suggest a analyzed estimation results of the motor parameters that developing five-phase squirrel-cage IM have a stator of concentrated winding for experimental within variable over current load at rated input frequency. There are results of stator winding measurement, no-load test, locked-rotor test, variable over current load test, and estimated parameters of equivalent circuits using manufactured experimental apparatus by IEEE Standard Test Procedure for Polyphase Induction Motors and Generators 112-2004.

시스템 식별법에 의한 복합 부하 모델링 (The Combined Load Modeling based on the System Identification)

  • 심건보;김주락;오임걸
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.260-264
    • /
    • 2007
  • Many load modeling concepts have been proposed in the past. Efforts of load modeling may be summarized into three approaches ; the first one is to find an aggregation of various different load components scattered and distributed in an area. The second one is to find parameters to represent load from field tests, if any. And the third one is how to present the load of motor components could be represented. This paper proposes a system identification of combined load modeling to cover the second approach. In this paper, an improved method of system identification is suggested for the combined load model (dynamic and static load model) in which parameters of the equivalent induction motor. polynomial type load and their compositions.

  • PDF

전계방출광원에서 전도성 입자를 이용한 고효율 형광막 특성 연구 (Study on high efficient phosphor layer using conductive powder particle in field emission light source)

  • 정세정;김광복;이선희;김용원
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.3-6
    • /
    • 2007
  • The Light brightness is to enhance the luminescence efficiency of phosphor including conductive material. In preparing the anode layer, phosphors mixed with conductive material prepared with pastes of polymer resin using by screen printing method. When the prepared anode layer bombarded by cold electron from emitter of cathode, it give rise to form the secondary electron from those of conductive materials such as ITO powder. Furthermore, we are expect to enhance the luminescence efficiency more than without conductive material.

  • PDF

단위역률동작을 위한 동기 발전기 여자 시스템용 2단 3상 PWM AC/DC 컨버터 (2-stage 3-phase PWM AC/DC Converter for Unity Power Factor Drive of Synchronous Generator)

  • 이상훈;김태형;이동희;안진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.187-192
    • /
    • 2007
  • The terminal voltage of a synchronous generator is maintained by the field current control of excitation system Generally AC/DC converter which is component of AVR(Automatic Voltage Regulator) system for excitation current control is connected to diode rectifier and DC/DC converter system In the case of diode rectifier system of phase controlled converter, AC/DC converter has low power factor and some low order harmonics in the line current. In this paper, two-stage three-phase PWM AC/DC converter is studied to solve these problems, The proposed method is verified by the computer simulations and experimental results in prototype generation system.

  • PDF

동기발전기 여자시스템 제어를 위한 직접순시전압제어기법 (Direct Instantaneous Voltage Control Strategy for Synchronous Generator Excitation System)

  • 이상훈;김태형;이동희;안진우
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 춘계학술대회 논문집
    • /
    • pp.218-223
    • /
    • 2007
  • This paper presents a simple, robust excitation control system for synchronous generator using direct instantaneous voltage control(DIVC) method. The proposed DIVC excitation system can operate as high dynamics of power conversion system without any control gains such as Pill controller. And the transient overshoot of generator voltage can be suppressed with a simple time constant. For the continuous control of excitation system, the fast IGBT inverter system is used in this paper for exciter's field control. The proposed control scheme is verified by the computer simulations and experimental results in the prototype generation system.

  • PDF

A Improved Method of Determining Everett Function with Logarithm Function and Least Square Method

  • Hong, Sun-Ki
    • 조명전기설비학회논문지
    • /
    • 제22권7호
    • /
    • pp.16-21
    • /
    • 2008
  • For Preisach model, Everett function from the transient curves is needed to simulate the hysteresis phenomena. However it becomes very difficult to get the function if the it would be made only from experiments. In this paper, a simple and stable procedure using least square method and logarithm function to determine the Everett function which follows the Gauss distribution for interaction field axis is proposed. The characteristics of the parameters used in this procedure are also presented. The proposed method is applied to implement hysteresis loops. The simulation for hysteresis loop is compared with experiments and good agreements could be shown.