• Title/Summary/Keyword: Field Installation

Search Result 1,199, Processing Time 0.027 seconds

Analysis of Ground Disturbance Characteristics by Field Smear Zones Test (현장스미어존 시험에 의한 지반교란특성 분석)

  • 진규남;이재식;박영목;정하익;진현식
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2000.03b
    • /
    • pp.583-590
    • /
    • 2000
  • The installation of vertical drains by using a mandrel causes significant disturbance of the subsoil. Thus a smear zone may be developed with reduced permeability and increased compressibility. In this paper the extent of smear zone developing ground disturbance with the installation of mandrels are analysed by field smear zone test. The extent and the consolidation characteristics of smear zones around the mandrels is compared with the shape, the size of mandrel and penetration speed and is evaluated from the field smear test results. (circular, sqare, rectangle and oval type)

  • PDF

Study on Carbon Nano Fiber Emitter for Field Emission Lamp (전계방출광원용 카본나노파이버 에미터 연구)

  • Kim, Kwang-Bok;Lee, Sun-Hee;Yu, Seung-Ho;Kim, Dae-Jun;Kim, Yong-Won
    • Proceedings of the Korean Institute of IIIuminating and Electrical Installation Engineers Conference
    • /
    • 2008.05a
    • /
    • pp.21-24
    • /
    • 2008
  • Properties of carbon nano fiber (CNF) as field emitters were described. Carbon nano fiber (CNF) of herringbone was prepared by thermal chemical vapor deposition(CVD). Field emitters mixed with organic binders, conductive materials and were prepared by screen-printing process. In order to increase field emissions, the surface treatment of rubbing & peel-off was applied to the printed CNF emitters on cathode electrode. The measurements of field emission properties were carried out by using a diode structure inline vacuum chamber. CNF of herringbone type showed good emission properties that a turn on field was as low as 2.1 $V/{\mu}m$ and current density was as large as 0.15 $mA/cm^2$ of 4.2 $V/{\mu}m$ with electric field. Through the results. we propose that CNFs are suitable for application of electron emitters in Field Emission Devices.

  • PDF

Determination of Smear Zone by Field CPT Test (현장CPT시험에 의한 스미어존의 범위 산정)

  • 진규남;김경호;정길수;정하익
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1999.10a
    • /
    • pp.81-86
    • /
    • 1999
  • The installation of vertical drains by means of a mandrel causes significant remolding of the subsoil, especially in the immediate vicinity of the mandrel. Thus, a zone of smear will be developed with reduced permeability and increased compressibility. This paper is mainly concerned with a field study to investigate the effect of smear due to vertical drain installation. In the present study, a field smear test was conducted to assess the extent of the smear zone around the vertical drain. The extent of the smear zone around a vertical drain was evaluated from the CPT results. CPT test was carried out to some distance around the mandrel installation. The test results revealed that a smear zone was estimated to be 3.6~5.3 times of the mandrel diameter.

  • PDF

STRENGTH CHANGES OF SURROUNDING CLAY DUE TO SOIL-CEMENT COLUMN INSTALLATION

  • Miura, Norihiko
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 1997.10a
    • /
    • pp.19-36
    • /
    • 1997
  • This paper discusses the reduction and subsequent recovery and increase of shear strength of clay in the vicinity of soil-cement column. Laboratory and field tests were conducted to investigate the effects on surrounding clay during and after soil-cement column installation in soft Ariake clay. Discussions were made on the mechanism of strength changes of clay by considering the thixotropic recovery, reconsolidation effect, penetration of cement slurry and diffusion of exchangeable cations. On the basis of field and laboratory observations, 10 days after column installation, the decreased shear strength of surrounding clay during mixing was recovered and 30 days later, shear strength of surrounding clay increased 30% by average. Therefore, it is recommended that the increase of shear strength of clay can be taken into consideration in the bearing capacity and stability analysis of the composite ground.

  • PDF

Field Demonstration of the Distribution STATCON-Installation & Evaluation (배전용 STATCON 설치 사례-설치 및 평가)

  • Cha, J.D.;Kim, J.M.;Hong, S.W.;Lee, H.S.;Lee, K.S.;Oh, K.I.
    • Proceedings of the KIEE Conference
    • /
    • 1999.07f
    • /
    • pp.2641-2643
    • /
    • 1999
  • This paper describes the first field demonstration of the distribution STATCON in Korea including installation and its evaluation for improving power quality in distribution system. The purpose of installation is to verify functionally the voltage source inverter based equipment for voltage regulation and harmonic mitigation in distribution line. The operational data resulting from field test and the site figure are included.

  • PDF

A Study on the Analysis of Field Condition for Ground Fault Protection Installation among Electrical Installations in the Entertainment Area (공연장의 전기설비중 지락보호설비에 대한 현장실태분석 연구)

  • Bae, S.M.;Kim, H.S.;Gil, H.J.;Lee, G.H.
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1721-1723
    • /
    • 2002
  • This paper deals with the analysis of field condition for earth leakage current alarming system in the stage lighting, stage sound stage machinery installation. These analyses of field condition were carried out in accordance with investigating an installation of earth leakage current alarming system with respect to a main line of power source, dimmer, sound equipment, machinery mobile unit equipment and so on. As a result of analyses. The earth leakage current alarming system has been installed only a part of the main line of power source and the probability of places which were installed was less than 50(%). Therefore, it is desirable that the earth leakage current alarming system is installed at places which are suitable, for example, dimmer, each kind machinery etc. in order to prevent electrical hazard.

  • PDF

Development of New Micropiling Technique and Field Installation (신개념 마이크로파일 개발 및 현장시험시공)

  • Choi, Chang-Ho;Goo, Jeong-Min;Lee, Jung-Hoon;Cho, Sam-Deok;Jeong, Jae-Hyeong
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.571-578
    • /
    • 2009
  • Recently, micropiling techniques are increasingly applied in foundation rehabilitation/underpinning and seismic retrofitting projects where working space provides the limited access for conventional piling methods. Micropiling techniques provide environmental-friendly methods for minimizing disturbance to adjacent structures, ground, and the environment. Its installation is possible in restrictive area and general ground conditions. The cardinal features that the installation procedures cause minimal vibration and noise and require very low ceiling height make the micropiling methods to be commonly used for underpin existing structures. In the design point of view, the current practice obligates the bearing capacity of micropile to be obtained from skin friction of only rock-socketing area, in which it implies the frictional resistance of upper soil layer is ignored in the design process. In this paper, a new micropiling method and its verification studies via field installation are presented. The new method provides a specific way to grout bore-hole to increase frictional resistance between surrounding soil and pile-structure and it allows to consider the skin friction of micropiles for upper soil layer during design process.

  • PDF

Optimum Design of Glass Net in 2[MVA] Mold Transformer (2[MVA] 배전용 몰드변압기의 글라스넷 형상 최적설계)

  • Jeon, Mun-Ho;Kim, Chang-Eob
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.1
    • /
    • pp.107-112
    • /
    • 2011
  • In this paper, the optimum design of the glass net shape was studied to minimize the electric field of mold transformer. The glass net is used for reinforcement in structure between coils and epoxy, but it can cause to increase the electric field and the partial discharge. Therefore, the optimum design of glass net is required to minimize the electric field. In this paper, the objective function was approximated by using response surface method and then Zoom-in method was used for optimal design to minimize the electric field. The electric field was analysed using finite element method for each shape of glass nets.

Design of Magnetic Field Compensation System Model for AC Magnetic Field Shielding (교류자기장 차폐를 위한 자기장 상쇄장치 모델의 설계)

  • Choi, Hak-Yun
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.25 no.7
    • /
    • pp.78-82
    • /
    • 2011
  • In this paper, magnetic field compensation system with an open architecture and can be installed indoors is designed and measured by fabricated. To verify the shielding effectiveness, two rectangular helmholtz coils with 3-axis are fabricated to generate magnetic field and measured magnetic field inside compensation coil for 1~60[Hz], According to measurements, AC shielding effectiveness of compensation system is 96[%] of 1[Hz], 95[%] of 30[Hz] and 90[%] of 60[Hz]. The performance of system therefore can be used as the magnetically shielded room for medical and industrial field.