• Title/Summary/Keyword: Field Component

Search Result 1,644, Processing Time 0.029 seconds

Signal Processing for Multiaxial Vibration Fatigue Test on Vehicle Component (자동차 부품에 대한 다축 진동내구 시험용 신호처리 방법)

  • Bae, Chul-Yong;Kim, Chan-Jung;Lee, Dong-Won;Lee, Bong-Hyun;Na, Byung-Chul
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.18 no.3
    • /
    • pp.368-374
    • /
    • 2008
  • Multi-axial simulation table(MAST) is widely used in motor companies as the multi-axial excitor for vibration fatigue of target component, which provides the vibrational condition as close as the vehicle test. However, the vibration fatigue performance of target component can be guaranteed with MAST system only in case the input profile covers the required severity of the target component on field test. In this paper, the signal processing for multi-axial vibration fatigue test on vehicle component is presented, from the data acquisition of the target component to the derivation of input profile. To compare the severity of vibration condition between field and proving ground, the energy principle of a equivalent damage is proposed and then, it is determined the optimal combination of special events on proving ground using a sequential searching optimal algorithm. To explain the vibration methodology clearly, seat and door component of vehicle are selected as a example.

Analysis on Electric Field Based on Three Dimensional Atmospheric Electric Field Apparatus

  • Xing, Hong-yan;He, Gui-xian;Ji, Xin-yuan
    • Journal of Electrical Engineering and Technology
    • /
    • v.13 no.4
    • /
    • pp.1697-1704
    • /
    • 2018
  • As a key component of lighting location system (LLS) for lightning warning, the atmospheric electric field measuring is required to have high accuracy. The Conventional methods of the existent electric field measurement meter can only detect the vertical component of the atmospheric electric field, which cannot acquire the realistic electric field in the thunderstorm. This paper proposed a three dimensional (3D) electric field system for atmospheric electric field measurement, which is capable of three orthogonal directions in X, Y, Z, measuring. By analyzing the relationship between the electric field and the relative permittivity of ground surface, the permittivity is calculated, and an efficiency 3D measurement model is derived. On this basis, a three-dimensional electric field sensor and a permittivity sensor are adopted to detect the spatial electric field. Moreover, the elevation and azimuth of the detected target are calculated, which reveal the location information of the target. Experimental results show that the proposed 3D electric field meter has satisfactory sensitivity to the three components of electric field. Additionally, several observation results in the fair and thunderstorm weather have been presented.

Impact Angle Control Guidance Synthesis for Evasive Maneuver against Intercept Missile

  • Yogaswara, Y.H.;Hong, Seong-Min;Tahk, Min-Jea;Shin, Hyo-Sang
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.18 no.4
    • /
    • pp.719-728
    • /
    • 2017
  • This paper proposes a synthesis of new guidance law to generate an evasive maneuver against enemy's missile interception while considering its impact angle, acceleration, and field-of-view constraints. The first component of the synthesis is a new function of repulsive Artificial Potential Field to generate the evasive maneuver as a real-time dynamic obstacle avoidance. The terminal impact angle and terminal acceleration constraints compliance are based on Time-to-Go Polynomial Guidance as the second component. The last component is the Logarithmic Barrier Function to satisfy the field-of-view limitation constraint by compensating the excessive total acceleration command. These three components are synthesized into a new guidance law, which involves three design parameter gains. Parameter study and numerical simulations are delivered to demonstrate the performance of the proposed repulsive function and guidance law. Finally, the guidance law simulations effectively achieve the zero terminal miss distance, while satisfying an evasive maneuver against intercept missile, considering impact angle, acceleration, and field-of-view limitation constraints simultaneously.

Comparison of Magnetic Field and AC Losses in Solenoid Coil and Pancake Coil with HTS tape

  • Park, Myungjin;Lee, Kwangyoun;Jungwook Sim;Gueesoo Cha;Lee, Jikwang
    • Progress in Superconductivity and Cryogenics
    • /
    • v.5 no.1
    • /
    • pp.97-101
    • /
    • 2003
  • When HTS tapes are used in power application, they are used by winding form, such as, a pancake and a solenoid. When AC current is applied to the coil, Ac magnetic field is generated in winding. This AC magnetic field acts as an external magnetic field and makes loss. In this paper the radial magnetic field component ($B_r$) and the axial magnetic field component ($B_z$) in a pancake and a solenoid were calculated by numerical analysis method and compare with measured value. AC losses of a short sample were calculated by Norris equation and n numerical analysis based on Brandt equation. AC losses of the pancake coil and the solenoid coil were also calculated.

A Study of Development and Product ion Technology for Camcoder Iris Assembly (캠코더용 Iris Assembly의 국산화 및 생산 기술 개발 사례)

  • Ko, Jong-Sun
    • Proceedings of the KIEE Conference
    • /
    • 1996.07a
    • /
    • pp.250-252
    • /
    • 1996
  • In this paper, the principle of operation. the part characteristic, characteristic of component movement, analysis are carried out for camcoder iris assembly which is one of the important element component in Video large projection TV instrument, and some Know-how for development of element component is also included. The magnetic field circuit for the small and simple structure with low power consumption is introduced and new materials of yoke for small motor system is suggested. Especially, the relation with remained magnetic field and operation duration time is analyzed by experimental results. Some problems of nonlinear torque characteristics include to obtain the simple and low cost structure in domestic production of element component is analyzed. Furthermore, development procedure is suggested for iris assembly and some methods to reduce the burr with some check points for small precise accessories are explained.

  • PDF

Module level EMC verification method for replacement items in nuclear power plant

  • Hee-Taek Lim;Moon-Gi Min;Hyun-Ki Kim;Gwang-Hyun Lee;Chae-Hyun Yang
    • Nuclear Engineering and Technology
    • /
    • v.55 no.7
    • /
    • pp.2407-2418
    • /
    • 2023
  • Internal replaceable electronic module substitutions can impact EMC (ElectroMagnetic Compatibility) qualification testing and results if EMC testing is conducted at the cabinet level. The impact of component substitutions on EMC qualification results therefore should be evaluated. If a qualitative evaluation is not adequate to ensure that the modified product will not impact the cabinet level EMC qualification results, a new qualification testing should be conducted. Component level retesting should be conducted under electromagnetically equivalent conditions with the cabinet level test. This paper analyzes the propagation of conducted susceptibility test waveforms in a representative cabinet and evaluates the impact of component substitutions on cabinet level EMC qualification results according to the location of the replacement items. A guideline for a qualitative evaluation of the impact of component substitutions is described based on the propagation of the conducted susceptibility test waveforms. A module level test method is also described based on an analysis of the shielding effectiveness of the cabinet.

A study on the SMES component modeling using PSCAD/EMTDC (PSCAD/EMTDC를 이용한 SMES Component modeling에 관한 연구)

  • Kim, Jin-Gun;Kim, Jae-Ho;Jung, Hee-Yeol;Park, Min-Won;Yu, In-Keun
    • Proceedings of the KIEE Conference
    • /
    • 2007.07a
    • /
    • pp.1998-1999
    • /
    • 2007
  • Before applying the HTS(High Temperature Superconductor) power devices to a real utility network, system analysis should be carried out by some simulation tools. PSCAD/EMTDC simulation tool is one of the most popularized useful analysis tools for electrical power system. Unfortunately the model component for HTS coil is not provided in PSCAD/EMTDC simulation tool. In this paper, EMTDC model component for HTS coil has been developed considering real characteristics of HTS coil like critical current, temperature and magnetic field. The developed model component of HTS coil could be used for power system application. Using the developed model component for HTS coil, we can easily do the simulation of HTS power devices application test in utility with the various inductance, quench current, inner magnetic field, and temperature values, for instances; SMES(Superconducting Magnetic Energy Storage) system, superconducting motor, transformer, and FCL(Fault Current Limiter)

  • PDF

New Higher-Order Fixed-Interface Component Mode Synthesis by Applying a Field-Consistency Concept (장-일치 개념을 적용한 신 고차 구속 모드 합성법)

  • Kang, Jeong-Hoon
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2000.06a
    • /
    • pp.536-542
    • /
    • 2000
  • The present paper introduces a new fixed interface component mode synthesizing technique based on the notion of higher-order field-consistency. The present technique employs higher-order residual constraint modes in addition to lower fixed interface normal modes while consistency in matching field variables at the substructure interface is maintained. The present field-consistency approach does not increase the size of the synthesized system even if higher-order residual constraint modes are included. A new field-consistent higher-order synthesis technique is first presented and a numerical example is given to verify the present method.

  • PDF

Development and Performance Evaluation of a Two-component Thin Spray-on Liner to Guarantee Its Homogeneous Qualities and to Reduce Dust (균질한 품질 확보와 분진 저감을 위한 2성분 박층 뿜칠 라이너의 개발과 성능평가)

  • Chang, Soo-Ho;Choi, Soon-Wook;Lee, Chulho;Kang, Tae-Ho;Hwang, Gwi-Sung;Kim, Jintae;Choi, Myung-Sik
    • Tunnel and Underground Space
    • /
    • v.26 no.5
    • /
    • pp.441-453
    • /
    • 2016
  • This study aimed to develop a two-component TSL suitable for reducing dust and guaranteeing homogeneous qualities during its spraying. Its performance was evaluated by a series of laboratory and field tests. High ductility of two-component TSL prototypes resulted in increasing their elongation at break even though their tensile strengths were slightly lower than those of one-component powder TSLs. One prototype of the two-component TSLs developed in this study was verified to satisfy every criterion specified by EFNARC (2008). Especially, it increased the average compressive strength of mortar specimens by 50% even when it coated them only with the thickness of 3 mm. From a preliminary spraying test, a spraying machine suitable for the developed TSL prototype was derived and modified. After its field application, dust and rebound generated during its spraying works were found to be very minimal. Its spraying rate was recorded to be approximately $60m^2/hr$. In addition, it showed a very rapid hardening characteristic compared with general sprayable waterproofing membranes.

A Study on the Evaluation Method of Field Uniformity(FU) for Radiated Immunity Test of Vehicle Component (차량용 전장품의 복사내성 평가를 위한 균일장 측정방법에 대한 연구)

  • Yoon, Jae Sang;Hong, Hyun Gwi;Kam, Dong Gun
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2017.05a
    • /
    • pp.633-636
    • /
    • 2017
  • This thesis is about the evaluation method of field uniformity for radiated immunity test of vehicle component. Radiated immunity test is to find out whether a EUT has enough immunity or hold normal operation during applied electromagnetic interference. Field Uniformity(FU) measurement is essential for generate uniform field on DUT and Harness. But Standard of Radiated Immunity(RI) test for vehicle component based on ISO 11452-2 has not been specified a Field Uniformity(FU). So compared and analyzed with other standard which is defined by a specified a Field Uniformity. As a result, deviation occurs in the difference test condition and test method. In this thesis, proposal new measurement method of field uniformity that is considered test conditions of ISO 11452-2 and check the validity through actual test.

  • PDF