• 제목/요약/키워드: Field Compensation

검색결과 406건 처리시간 0.026초

교류자기장 차폐를 위한 자기장 상쇄장치 모델의 설계 (Design of Magnetic Field Compensation System Model for AC Magnetic Field Shielding)

  • 최학윤
    • 조명전기설비학회논문지
    • /
    • 제25권7호
    • /
    • pp.78-82
    • /
    • 2011
  • In this paper, magnetic field compensation system with an open architecture and can be installed indoors is designed and measured by fabricated. To verify the shielding effectiveness, two rectangular helmholtz coils with 3-axis are fabricated to generate magnetic field and measured magnetic field inside compensation coil for 1~60[Hz], According to measurements, AC shielding effectiveness of compensation system is 96[%] of 1[Hz], 95[%] of 30[Hz] and 90[%] of 60[Hz]. The performance of system therefore can be used as the magnetically shielded room for medical and industrial field.

현장 적용성을 고려한 기둥축소량의 최적보정시스템 개발 (Development of Field-friendly Optimal Compensation System for Differential Column Shortening)

  • 김영민
    • 한국전산구조공학회논문집
    • /
    • 제23권2호
    • /
    • pp.139-152
    • /
    • 2010
  • 본 연구에서는 현장 적용성을 고려한 기둥축소량의 최적보정시스템을 그래픽-사용자 인터페이스의 컴퓨터 프로그램으로 개발하였다. 구현된 시스템은 성능 및 시공상의 다양한 제약조건을 만족하면서 상대보정과 혼합보정이 모두 가능하다. 제안된 시스템에서는 기둥축소량 보정전과 보정후의 구조물 형상을 그래픽으로 확인가능하며, 각 층의 보정결과는 기둥축소량 보고서로 바로 활용 가능한 도면으로 출력된다. 제안된 시스템을 실제 축소량 보정이 수행된 61, 42, 49, 53층의 네 건물에 적용한 결과, 제약조건을 쉽게 변경하면서 축소량 보정을 수행할 수 있고, 기존의 방법으로는 해를 구하지 못하는 경우에도 손쉽게 해를 구할 수 있어 현장 적용성이 뛰어남을 확인하였다.

소방공무원 행정종합배상공제 사례 및 문제점 - 구급사례 중심으로 - (Cases and problems of comprehensive administrative compensation deduction for firefighters: focused on emergency medical service case)

  • 김준호;홍영표;김경용
    • 한국응급구조학회지
    • /
    • 제26권1호
    • /
    • pp.119-127
    • /
    • 2022
  • Purpose: This study aimed to examine the necessity of administrative compensation insurance and claims cases during the emergency medical service process among administrative compensation insurance cases and suggests problems and improvement measures. Methods: We compared the details of administrative compensation insurance claims of 15 cities and provinces, excluding Seoul and Kwangju, from 2017 to 2020 by requesting details disclosure of the comprehensive deduction for administrative compensation in 17 cities and provinces across the country. Results: A total of 69 cases were compensated through the administrative comprehensive compensation deductions. There were 53 cases of damage that occurred at the field stage, 14 cases at the transfer and hospital stage, and two other cases. Conclusion: The 119 paramedics, which are the perpetrators, should be active in field activities and free from the psychological pressure caused by increased workload and litigation. Active compensation administration is required for damage cases occurring in the firefighting activities context.

Compensation of Cross Talk Error for Optical Voltage Sensors

  • Cho, Jae-Kyong
    • Journal of the Optical Society of Korea
    • /
    • 제11권4호
    • /
    • pp.177-182
    • /
    • 2007
  • This paper discusses the errors associated with electric field cross talk for optical voltage sensors in a three-phase electric system and provides a solution to compensate the errors. For many practical conductor configurations, the electric field cross talk may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the cross talk and built an electronic circuits based on it. The mechanism of the compensation and the corresponding error reduction were discussed.

Nonlinearity-Compensation Extended Kalman Filter for Handling Unexpected Measurement Uncertainty in Process Tomography

  • Kim, Jeong-Hoon;Ijaz, Umer Zeeshan;Kim, Bong-Seok;Kim, Min-Chan;Kim, Sin;Kim, Kyung-Youn
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2005년도 ICCAS
    • /
    • pp.1897-1902
    • /
    • 2005
  • The objective of this paper is to estimate the concentration distribution in flow field inside the pipeline based on electrical impedance tomography. Special emphasis is given to the development of dynamic imaging technique for two-phase field undergoing a rapid transient change. Nonlinearity-compensation extended Kalman filter is employed to cope with unexpected measurement uncertainty. The nonlinearity-compensation extended Kalman filter compensates for the influence of measurement uncertainty and solves the instability of extended Kalman filter. Extensive computer simulations are carried out to show that nonlinearity-compensation extended Kalman filter has enhanced estimation performance especially in the unexpected measurement environment.

  • PDF

수축 보상 모르타르의 현장 적용 연구 (An Application of Shrinkage Compensation Mortar in Construction Field)

  • 김기동;정성철;송명신;이경희
    • 콘크리트학회논문집
    • /
    • 제12권3호
    • /
    • pp.3-10
    • /
    • 2000
  • In this study, we compared a plain mortar with the CAS-system shrinkage compensation mortar for Ondol that is Korean traditional heating system. The Ondol mortar is necessary to have properties as non-crack, fine flatness and stability for thermal changes. especially, mortar'crack prevention is to be most important property in Ondol mortar. To develope the stable material on the crack-prevention, we used to calcium-sulfo-aluminate(CSA)system in shrinkage compensation mortar. And so, we confirmed the effects of calcium-sulfo-aluminate(CSA) system for mortar's physical properties such as setting time, compressive strength and expansion ratio for crack prevention. The initial and final setting time of the CSA mortar is faster than plain mortar about 2hours. And, Compressive strength increased about 20% that plain mortar. The crack length per unit area, plain mortar is 0.426∼0.481m/m2. The Results of apartment construction field test, the shrinkage compensation mortar is excellent about the crack-reduce effect.

Compensation of Electric Field Interference for Fiber-optic Voltage Measurement System

  • Cho, Jae-Kyong
    • Transactions on Electrical and Electronic Materials
    • /
    • 제9권2호
    • /
    • pp.84-88
    • /
    • 2008
  • In this paper, we analyze the errors associated with electric field interference for fiber-optic voltage sensors working in a three-phase electric system. For many practical conductor arrangements, the electric filed interference may cause errors unacceptable for the accuracy requirements of the sensors. We devised a real time compensation method for the interference by introducing geometric and weight factors. We realized the method using simple electronic circuits and obtained the real time compensated outputs with errors of 1 %.

37층 초고층주상복합건물 SRC기둥의 기둥축소량 현장계측 및 보정법 (Field Measurement and Compensation Method of Column Shortening for SRC Columns in 37-story Residential Building)

  • 송화철;도근영;조훈희
    • 한국건축시공학회지
    • /
    • 제5권4호
    • /
    • pp.145-152
    • /
    • 2005
  • Long-term axial shortening of the vertical elements of tail buildings results in differential movements between two elements and may lead to the additional moments of connection beam and slab elements, and other secondary effects, such as cracks of partitions or curtain walls. Accurate prediction of time-dependent column shortening is essential for tall buildings from both strength and serviceability aspects. The compensation method is different from reinforced concrete and SRC(Steel Reinforced Concrete) members. The SRC columns are usually compensated according to total differential shortening between two vertical elements. In this study, column shortenings of 37-story W building under construction are predicted and compensated. The SRC column shortenings are compared with the actual column shortening by field measurement and the column shortenings are reanalysed and recompensated.

수축보상을 위한 자기충전 콘크리트의 현장적용 (A Field Application of the Self-Compaction Concrete for Shrinkage Compensation)

  • 이상수;원철;박상준;김동석
    • 한국건축시공학회:학술대회논문집
    • /
    • 한국건축시공학회 2002년도 학술논문발표회
    • /
    • pp.7-12
    • /
    • 2002
  • The purpose of this study is to design and to apply the self-compaction concrete mixture to field, having not only high strength but also compensation for shrinkage without thermal crack under 4 sides outer restraint of the member. In the experimental mix, replacement ratio of limestone Powder, CSA expansive additives, and unit water were selected as parameters, using portland blast-furnace slag cement. And, bleeding test, expansibility test, hydration heat analysis were performed. As a results, when Cement is replaced with 35% limestone Powder, 6% CSA expansive additives at unit water 175kg/$m^3$, demanded performances of fresh and hardened self-compaction concrete are accomplished in the field application.

  • PDF

Analysis of Induced Voltage in Superconducting Magnet System for Background magnetic Field Generation in SSTF

  • Qiuliang wang;Yoon, Cheon-Seog;Sungkeun Baang;Kim, sangbo;Park, Hyunki;Kim, Keeman
    • 한국초전도저온공학회:학술대회논문집
    • /
    • 한국초전도저온공학회 2000년도 KIASC Conference 2000 / 2000년도 학술대회 논문집
    • /
    • pp.185-188
    • /
    • 2000
  • The voltage induced in the superconducting background magnet system is analyzed according to the calculation of self inductance and mutual inductance. The voltage induced by blip and compensation coils of the background magnet system is about 6.4V. In order to charge the main background magnet, the power supply must provide the minimum voltage of 1.1 kV. the compensation coils have an influence on the field distribution. The compensation coils result in the decreasing center field about 2.67%. It can remarkably decrease the ac losses and the voltage on the current leads of the background magnet.

  • PDF