• Title/Summary/Keyword: Fiberglass-Resin-Putty

Search Result 1, Processing Time 0.015 seconds

A Study on the Mechanical Characteristic Change Accordance with Surface Damaged Submarine GFRP Repairing (잠수함용 GFRP 표면결함 수리에 따른 기계적 특성변화 연구)

  • Jung, Young In;Koo, Ja Gil;Lee, Yoon Suk
    • Journal of Korean Society for Quality Management
    • /
    • v.48 no.2
    • /
    • pp.257-267
    • /
    • 2020
  • Purpose: The purpose of this study is to define guideline for fiber-glass-resin-putty repairing method for submarine GFRP by comparing structural strength between normal GFRP and putty repaired GFRP. Methods: GFRP specimen tensile and flexural tests are conducted in accordance with ASTM D3039/3039M-17 and ASTM D790 Procedure A. The collected data was analysed whether satisfies its structural strength criteria. Furthermore, It is analysed to find dominant reason of structural strength changes. Results: The result of the study is as follows; flexural strength of GFRP is satisfied strength criteria for all test cases, but tensile strength is not satisfied its criteria for some cases which over 2 mm depth of surface damage. Conclusion: The fiberglass-resin-putty repairing method should be applied to under 2 mm depth of damage which is not affecting to roving fiber layer destruction in GREP laminate.