• Title/Summary/Keyword: Fiber-reinforced

Search Result 4,416, Processing Time 0.023 seconds

A Study on Compression Molding Process of Long Fiber Reinforced Plastic Composites(Part1, Effect of Geometrical Change of Products on Fiber Orientation) (장섬유강화 플라스틱 복합재의 압축성형 공정에 관한 연구(제1보, 섬유배향에 미치는 성형품의 기하학적인 형상변화))

  • 조선형;오영준;이건상;윤성운
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.10a
    • /
    • pp.33-38
    • /
    • 2001
  • This study aims to systematically research the various phenomena which arise from compression molding of fiber reinforced plastic composites. Long fiber reinforced plastic composites are rib type compression molded in order to measure the orientation in products, and the specimens are photographed with soft X-ray. The intensity of the photograph is applied by an image scanner, and the fiber orientation distribution of products is measured by using an image processing technique.

  • PDF

Unconfined Strength Characteristics of Fiber Reinforced Soil (섬유혼합보강토의 일축강도 특성)

  • 장병욱
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.41 no.1
    • /
    • pp.72-78
    • /
    • 1999
  • The purpose of this study was to evaluate the properties of unconfined strength of dry soil which was reinforced with polypropylene fiber. It is found that unconfined compressive strength and strain of dry soil without fiber were decreased as water content was increased. As mixing ration of fiber was increased , unconfined compressive strength and failure strain of dry soil reinforced with polypropylene fiber were increased. When mixing ration was larger than 0.5 % , unconfined compressive strength was gradually increased. The longer fiber was, the largest post peak strength was obtained and the larger strain was reached. Tensile strength of dried fiber reinforced soil was larger than that of dry soil without fiber.

  • PDF

Characteristics of Fracture Energy on Steel Fiber-Reinforced Lightweight Polymer Concrete

  • Youn, Joon-No;Sung, Chan-Yong
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.7
    • /
    • pp.11-19
    • /
    • 2003
  • In this study, unsaturated polyester resin, artificial lightweight coarse aggregate, artificial lightweight fine aggregate, heavy calcium carbonate and steel fiber were used to produce a steel fiber-reinforced lightweight polymer concrete with which mechanical properties were examined. Results of this experimental study showed that the flexural strength of unnotched steel fiber-reinforced lightweight polymer concrete increased from 8.61 to 13.96 MPa when mixing ratio of fiber content increased from 0 to 1.5%. Stress intensity factors($K_{IC}$) increased with increasing fiber content ratio while it did not increase with increasing notch ratio. Energy release rate ($G_{IC}$) turned out to depend upon the notch size, and it increased with increasing steel fiber content.

A Study on Mechanical Characteristics of Reinforced Concrete Columns Confined with Carbon Fiber Sheet (CFS로 횡보강된 철근콘크리트 기둥의 역학적 특성에 관한 연구)

  • 권영웅;정성철
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.743-749
    • /
    • 1999
  • Recently new rehabilitation techniques have been proposed with advanced composite materials like carbon fiber, aramid, glass fiber sheet and so forth. The purpose of this paper is to investigate the mechanical characteristics of reinforced concrete columns confined with carbon fiber sheet and evaluate the degree of their strengthening effect. For the test, the specimen size of column is 15cm$\times$15cm$\times$90cm reinforced with 4 number of main bars of 10 mm diameter, tied bars of 6 mm diameter and slenderness ratio 20. Columns were wrapped with carbon fiber sheet along the column length. It is necessary to make some assumption regarding the confinement of carbon fiber sheet to apply to reinforced concrete columns under concentric loads. The strength gain effect of columns confined with carbon fiber sheet could be predicted using the proposed equation.

  • PDF

Design Equation for Punching Shear Capacity of SFRC Slabs

  • Higashiyama, Hiroshi;Ota, Akari;Mizukoshi, Mutsumi
    • International Journal of Concrete Structures and Materials
    • /
    • v.5 no.1
    • /
    • pp.35-42
    • /
    • 2011
  • In this paper, a design equation for the punching shear capacity of steel fiber reinforced concrete (SFRC) slabs is proposed based on the Japan Society of Civil Engineers (JSCE) standard specifications. Addition of steel fibers into concrete improves mechanical behavior, ductility, and fatigue strength of concrete. Previous studies have demonstrated the effectiveness of fiber reinforcement in improving the shear behavior of reinforced concrete slabs. In this study, twelve SFRC slabs using hooked-ends type steel fibers are tested with varying fiber dosage, slab thickness, steel reinforcement ratio, and compressive strength. Furthermore, test data conducted by earlier researchers are involved to verify the proposed design equation. The proposed design equation addresses the fiber pull-out strength and the critical shear perimeter changed by the fiber factor. Consequently, it is confirmed that the proposed design equation can predict the punching shear capacity of SFRC slabs with an applicable accuracy.

Dynamic Deformation Characteristics of Fiber Mixed Silty Sand (섬유보강 실트질 모래의 동적 변형특성)

  • Heo, Joon;Chang, Pyoung-Wuck
    • Journal of The Korean Society of Agricultural Engineers
    • /
    • v.47 no.6
    • /
    • pp.59-70
    • /
    • 2005
  • A series of resonant column test was performed to investigate the dynamic deformation characteristics of silty sand soils mixed with polypropylene fibrillated type fiber. Results show that optimum mixing ratios were $0.2\%$ for 19mm of cut fiber for shear modulus and $0.1\%$ for 60mm cut fiber fur damping ratio. As shear strain was increased, normalized values of shear modulus (G(Reinforced)/ G(Unreinforced)) of fiber reinforced soil were increased up to $10^{-3}\%\~10^{-1}\%$ ranges. However, normalized damping ratio (D(Reinforced/D(Unreinforced)) was diminished with an increase in strain beyond $10^{-3}\%\~10^{-1}\%$ for the damping capacity of soils mixed with fiber. Normalized shear modulus $(G/G_{max})$ obtained from the test was plotted in the chart suggested by Seed and Idriss. The shear modulus of silty sand was located between sand and gravel curves.

Mechanical characteristics of Macro-Fiber Reinforced Concrete Pavement (매크로 섬유로 보강된 콘크리트 포장의 역학적 특성)

  • Choi, Sung-Yong;Jung, Woo-Tai;Park, Jong-Sup
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2009.11a
    • /
    • pp.171-174
    • /
    • 2009
  • This study analyzes the change of the basic characteristics of pavement concrete according to the reinforcement of macro-fiber and the results of the study can be summarized as follows. In the case of the compressive strength of the concrete, the fiber reinforced pavement concrete shows a small decreasing level compared to the basic mixing of pavement concrete (hereafter referred as 'Plain') based on the aging of 28 days. In particular, the polypropylene fiber made in Korea represents a decrease in the strength about 12% compared with that of the Plain. In the case of the tensile strength, it shows certain improvements in the tensile performance compared with that of the Plain. In particular, in the case of the polyvinyl alcohol fiber that shows the largest improvement in tensile performance, it shows an increase in its strength about 21%. In the case of the bending strength, there are no improvements in its strength in the fiber reinforced concrete compared to that of the Plain.

  • PDF

Seismic Performance Evaluation of Reinforced Concrete Columns by Applying Steel Fiber-Reinforced Mortar at Plastic Hinge Region (소성힌지부 강섬유 혼입 모르타르 적용 철근콘크리트 기둥의 내진성능평가)

  • Cho, Chang-Geun;Han, Sung-Jin;Kwon, Min-Ho;Lim, Cheong-Kweon
    • Journal of the Korea Concrete Institute
    • /
    • v.24 no.3
    • /
    • pp.241-248
    • /
    • 2012
  • This paper presents a reinforced concrete composite column method in order to improve seismic performance of reinforced concrete column specimens by selectively applying steel fiber-reinforced mortars at the column plastic hinge region. In order to evaluate seismic improvement of the newly developed column method, a series of cyclic load test of column specimens under a constant axial load was investigated by manufacturing three specimens, two reinforced concrete composite columns by applying steel fiber-reinforced mortars at the column plastic hinge region and one conventional reinforced concrete column. Both concrete and steel fiber-reinforced mortar was cast-in placed type. From cyclic load test, it was found that the newly developed steel fiber-reinforced columns showed improved seismic performances than conventional reinforced concrete column in controlling bending and shear cracks as well as improving seismic lateral load-carrying capacities and lateral deformation capacities.

Interfacial bond properties and comparison of various interfacial bond stress calculation methods of steel and steel fiber reinforced concrete

  • Wu, Kai;Zheng, Huiming;Lin, Junfu;Li, Hui;Zhao, Jixiang
    • Computers and Concrete
    • /
    • v.26 no.6
    • /
    • pp.515-531
    • /
    • 2020
  • Due to the construction difficulties of steel reinforced concrete (SRC), a new composite structure of steel and steel fiber reinforced concrete (SSFRC) is proposed for solving construction problems of SRC. This paper aims to investigate the bond properties and composition of interfacial bond stress between steel and steel fiber reinforced concrete. Considering the design parameters of section type, steel fiber ratio, interface embedded length and concrete cover thickness, a total of 36 specimens were fabricated. The bond properties of specimens were studied, and three different methods of calculating interfacial bond stress were analyzed. The results show: relative slip first occurs at the free end; Bearing capacity of specimens increases with the increase of interface embedded length. While the larger interface embedded length is, the smaller the average bond strength is. The average bond strength increases with the increase of concrete cover thickness and steel fiber ratio. And calculation method 3 proposed in this paper can not only reasonably explain the hardening stage after the loading end curve yielding, but also can be applied to steel reinforced high-strength concrete (SRHC) and steel reinforced recycled coarse aggregate concrete (SRRAC).

Strengthening Effects of Slabs by Aramid Fiber Sheet (아라미드섬유 쉬트에 의한 슬래브의 보강효과)

  • Yeon, Kyu-Seok;Kang, Young-Sug;Kim, Hyung-Woo;Lee, Youn-Su;Kim, Nam-Gil
    • Magazine of the Korea Concrete Institute
    • /
    • v.11 no.2
    • /
    • pp.105-113
    • /
    • 1999
  • This study was conducted to evaluate the structural behaviors of Aramid fiber sheet reinforced slabs. Seven concrete slabs with $45{\times}8.5{\times}200cm$ were made for this experiment one slab with out being reinforced completely loaded until failure and the maximum load was obtained from this test. 70% of the maximum load was applied to 3 Aramid fiber sheet reinforced slabs after cracking and to the rest of 3 Aramid fiber sheet reinforced slabs without loading and cracking. Test results shows that maximum loading flexural rigidity and ductility for the Araimid fiber sheet reinforced slabs after initial cracking are similar as those for the Armied fiber sheet reinforced slabs without loading and cracking.