• Title/Summary/Keyword: Fiber reinforcing materials

Search Result 210, Processing Time 0.025 seconds

Integrity Evaluation of Sleeve Extension Composites Manufactured by Fiber Placement System (FPS) (Fiber Placement System(FPS)에 의해 제조된 복합재료 Sleeve Extension의 성형 건전성 평가)

  • Kong Jin-Woo;Kim Jin-Bong;Kim Tae-Wook;Ju Jin
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2004.04a
    • /
    • pp.254-257
    • /
    • 2004
  • Fiber placement system (FPS) carries out an advanced composites process which orients high strength reinforcing fibers in specific directions. The process includes wet winding, thermoset tape winding, thermoset prepreg placement and thermoplastic prepreg placement. FPS have the advantage of tape laying and filament winding with computer control and software. Using FPS can reduce costs, cycle times, structural weight, and handwork/rework when manufacturing composite parts. The sleeve extension is a part of the helicopter rotator systems. In this study, The sleeve extension composites were manufactured using FPS and tensile properties of this composites were characterized using universal testing machine(UTM).

  • PDF

Studying the effects of CFRP and GFRP sheets on the strengthening of self-compacting RC girders

  • Mazloom, Moosa;Mehrvand, Morteza;Pourhaji, Pardis;Savaripour, Azim
    • Structural Monitoring and Maintenance
    • /
    • v.6 no.1
    • /
    • pp.47-66
    • /
    • 2019
  • One method of retrofitting concrete structures is to use fiber reinforced polymers (FRP). In this research, the shear, torsional and flexural strengthening of self-compacting reinforced concrete (RC) girders are fulfilled with glass fiber reinforced polymer (GFRP) and carbon fiber reinforced polymer (CFRP) materials. At first, for verification, the experimental results were compared with numerical modeling results obtained from ABAQUS software version 6.10. Then the reinforcing sheets were attached to concrete girders in one and two layers. Studying numerical results obtained from ABAQUS software showed that the girders stiffness decreased with the propagations of cracks in them, and then the extra stresses were tolerated by adhesive layers and GFRP and CFRP sheets, which resulted in increasing the bearing capacity of the studied girders. In fact, shear, torsion and bending strengths of the girders increased by reinforcing girders with adding GFRP and CFRP sheets. The samples including two layers of CFRP had the maximum efficiencies that were 90, 76 and 60 percent of improvement in shear, torsion and bending strengths, respectively. It is worth noting that the bearing capacity of concrete girders with adding one layer of CFRP was slightly higher than the ones having two layers of GFRP in all circumstances; therefore, despite the lower initial cost of GFRP, using CFRP can be more economical in some conditions.

Comparison of metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture (상악 총의치 정중 파절 수리 시 금속선 및 유리섬유의 보강효과 비교)

  • Lee, Jung-Ie;Jo, Jae-Young;Yun, Mi-Jung;Jeon, Young-Chan;Jeong, Chang-Mo;Huh, Jung-Bo
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.51 no.4
    • /
    • pp.284-291
    • /
    • 2013
  • Purpose: This study compared fracture strength and fracture modes between metal wire reinforcement and glass fiber reinforcement in repaired maxillary complete denture. Materials and methods: In this study, fracture was reproduced on center of maxillary complete dentures and the denture was repaired with auto-polymerizing resin. The experimental groups (n = 10) were subjected to the following condition: without reinforcing material (control group), reinforcing with metal wire (W group), reinforcing with glass fiber pre-impregnated with light-curing resin (SES MESH, INNO Dental Co., Yeoncheon, Korea, G group). The fracture strength and fracture modes of a maxillary complete denture were tested using Instron test machine (Instron Co., Canton, MA, USA) at a 5.0 mm/min crosshead speed. The flexure load was applied to center of denture with a 20 mm diameter ball attachment. When fracture occurred, the fracture mode was classified based on fracture lines. The Kruskal-wallis test and the Mann-whitney U test were performed to identify statistical differences at ${\alpha}=.05$. Results: W group showed the highest value of fracture strength, there was no significant difference (P>.05) between control group and G group. Control group and W group showed anteroposterior fracture mainly, group W showed adhesive fracture of denture base and reinforcing material. Conclusion: In limitation of this study, the glass fiber did not improve the fracture strength of repaired maxillary complete denture, and adhesive failure was occurred along the lines of glass fiber.

Shear Strength and Permeability Characteristics of Soil Body Reinforced with Linear and Planar Reinforcing Materials (선형보강재와 평면보강재를 적용한 토체의 전단강도 및 투수특성)

  • 차경섭;장병욱;우철웅;박영곤
    • Magazine of the Korean Society of Agricultural Engineers
    • /
    • v.45 no.6
    • /
    • pp.162-171
    • /
    • 2003
  • Traditional methods of earth reinforcement consist of introducing strips, fabrics, or grids into an earth mass. Recently, discrete fibers are simply added and mixed with the soil, much the same as cement, lime or other additives. The advantages of randomly distributed fibers is the maintenance of strength isotropy, low decrease in post-peak shear strength and high stability at failure. In this study, new composite reinforcement structures which consist of geotextile and randomly distributed discrete fibers were examined their engineering properties, such as shear strength of the composite reinforced soil and permeability of short fiber reinforced soil. The increments of shear strength of composite reinforced soils were the sum of increments by fiber and woven geotextile, respectively. The permeability of short fiber reinforced soil was increased with fiber mixing ratio.

Post-heating behavior of concrete beams reinforced with fiber reinforced polymer bars

  • Irshidat, Mohammad R.;Haddad, Rami H.;Almahmoud, Hanadi
    • Structural Engineering and Mechanics
    • /
    • v.53 no.6
    • /
    • pp.1253-1269
    • /
    • 2015
  • The present paper investigates the post heating behavior of concrete beams reinforced with fiber reinforced polymer (FRP) bars, namely carbon fiber reinforced polymer (CFRP) bars and glass fiber reinforced polymer (GFRP) bars. Thirty rectangular concrete beams were prepared and cured for 28 days. Then, beams were either subjected (in duplicates) to elevated temperatures in the range (100 to $500^{\circ}C$) or left at room temperature before tested under four point loading for flexural response. Experimental results showed that beams, reinforced with CFRP and GFRP bars and subjected to temperatures below $300^{\circ}C$, showed better mechanical performance than that of corresponding ones with conventional reinforcing steel bars. The results also revealed that ultimate load capacity and stiffness pertaining to beams with FRP reinforcement decreased, yet their ultimate deflection and toughness increased with higher temperatures. All beams reinforced with FRP materials, except those post-heated to $500^{\circ}C$, failed by concrete crushing followed by tension failure of FRP bars.

Impact Properties of Organic Fiber Reinforced Thermoplastic Composites (유기섬유강화 열가소성고분자 복합재료의 충격특성)

  • Im, Seung-Soon;Lee, Seung-Bae;Lee, Yong-Moo;Choi, Hyeong-Ki
    • Applied Chemistry for Engineering
    • /
    • v.7 no.3
    • /
    • pp.424-432
    • /
    • 1996
  • The fiber reinforced thermoplastic composites(FRTP) were prepared with polypropylene fiber(PPF) as matrix and vinylon(VF), Aramid(KF) or nylon fiber(PAF) as reinforcing materials using the integrated fiber mixing apparatus. The composite sheets were prepared by compression molding and their impact and morphological properties were characterized. VF/PP system showed the maximum value in Izod impact strength, while KF/PP system showed the maximum value in high rate impact properties. Ductility Index(DI) order was VF/PP>KF/PP>PAF/PP. A maximum DI for VF/PP, 2.43, was obtained when the weight fraction of VF was 20%. The optimum amount of the reinforcing organic fiber was found to be 20~30%. As a result, it is concluded that VF/PP system has better interfacial adhesion properties than either KF/PP or PAF/PP.

  • PDF

FATIGUE CRACK GROWTH MONITORING OF CRACKED ALUMINUM PLATE REPAIRED WITH COMPOSITE PATCH USING EMBEDDED OPTICAL FIBER SENSORS (광섬유센서를 이용한 복합재 패치수리된 알루미늄판의 균열관찰)

  • 서대철;이정주;김상훈
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2001.05a
    • /
    • pp.250-253
    • /
    • 2001
  • Recently, based on the smart structure concept, optical fiber sensors have been increasingly applied to monitor the various engineering and civil structural components. Repairs based on adhesively bonded fiber reinforce composite patches are more structurally efficient and much less damaging to the parent structure than standard repairs based on mechanically fastened metallic patches. As a result of the high reinforcing efficiency of bonded patches fatigue cracks can be successfully repaired. However, when such repairs are applied to primary structures, it is needed to demonstrate that its loss can be immediately detected. This approach is based on the "smart patch" concept in which the patch system monitors its own health. The objective of this study is to evaluate the potentiality of application of transmission-type extrinsic Fabry-Perot optical fiber sensor (TEFPI) to the monitoring of crack growth behavior of composite patch repaired structures. The sensing system of TEFPI and the data reduction principle for the detection of crack detection are presented. Finally, experimental results from the tests of center-cracked-tension aluminum specimens repaired with bonded composite patch is presented and discussed.

  • PDF

A Study on the Hysteretic Behavior of High Strength Steel Fiber Reinforced Concrete Beam-Column Joint (강섬유 보강 고강도 철근 콘크리트 보-기둥 접합부의 이력 거동에 관한 연구)

  • 오경남;이정한;유영찬;이원호;정헌수
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.10a
    • /
    • pp.533-536
    • /
    • 1999
  • The primary purpose of this study is to investigate experimentally the effect of steel fiber reinforcement on the total energy dissipation capacity of R/C flexural members and to make a contribution to the construction of 40~60 story R/C high rise building by developing the new materials and reinforcing details which can improve the seismic performance of high-strength R/C beam-column joints. Experimental research was carried out on 4 type specimen under cyclic loading. Main variables are steel fiber reinforcement, intermediate reinforcements and yield strength of rebars. From the test results, steel fiber reinforcement can improve the ductility of R/C flexural members.

  • PDF

Tension Stiffening of High Performance Fiber-Reinforced Cementitious Composites (고인성 섬유보강 시멘트 복합체의 인장강성)

  • Yun Hyun-Do;Yang Il-Seung;Han Byung-Chan;Hiroshi Fukuyama;Cheon Esther;Kim Sun-Woo
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2004.11a
    • /
    • pp.441-444
    • /
    • 2004
  • This paper presnets the tensile behavior of 8 high performance fiber-reinforced cementitious composites (HPFRCCs) members, each reinforced with one deformed bar 16mm in diameter. The variables included HPFRCC(Ductal, steel cord and polyethylene hybrid fiber, PE fiber) versus normal concrete. Fibers used in HPFRCC significantly increased tensile strength, ductility, and tension stiffening of cementitious materials. For HPFRCC, after first cracking, tensile load continue to rise without fracture localization. Sequentially developed parallel cracks contributed to the inelastic strain at increasing stress level. After yielding of the reinforcing bars, HPFRCC showed increases in loads with increasing strains.

  • PDF

The Effect of Reinforcing Materials on the Transverse Strength of Denture Base Resin (의치상 레진 강화재가 의치상 굽힘강도에 미치는 영향)

  • Lee, Jun-Sik;Song, Young-Gyun;Cho, In-Ho
    • Journal of Dental Rehabilitation and Applied Science
    • /
    • v.28 no.4
    • /
    • pp.327-337
    • /
    • 2012
  • The object of this study was to find out the effect of various reinforcing materials including Quarts Splint$^{TM}$ Mesh on the transverse strength of the denture resin. QC-20 and Lucitone199$^{(R)}$ were used as the denture resin, and polyethylene fiber Ribbond$^{(R)}$, light curing quarts fiber Quarts Splint$^{TM}$ Mesh, metal mesh were used as the reinforcing materials. Ten specimens were fabricated for each group and the size of specimens was $2.0{\times}10.0{\times}65.0mm$. To compare the effect of resin thickness, additional specimens of $2.5{\times}10.0{\times}65.0mm$, $3.0{\times}10.0{\times}65.0mm$ were fabricated. In the control group, the transverse strength of Lucitone199$^{(R)}$ was significantly higher than that of QC-20(p<0.05). Among the specimens of 2.0 mm thickness fabricated with $Lucitone199^{(R)}$ and QC-20, they showed high transverse strength in the order of metal mesh, Quarts Splint$^{TM}$ Mesh, Ribbond$^{(R)}$, and control group. In the specimens of 2.0 mm, 2.5 mm thickness, the transverse strength of Quarts Splint$^{TM}$ Mesh were significantly higher than that of QC-20(p<0.05). But in the specimens of 3.0 mm thickness, there was no significant difference.