• 제목/요약/키워드: Fiber reinforcement concrete

검색결과 684건 처리시간 0.029초

강도설계법으로 산정된 탄소섬유시트 보강 철근콘크리트 보의 공칭 휨모멘트 (Determination of Nominal Moment of Strengthening Beam with Carbon Fiber Sheets Using Strength Method)

  • 조백순;정진환;김성도;박대효;이우철
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.593-598
    • /
    • 2002
  • Routinely, strength method for the determination of the nominal moment of reinforced concrete beam is assumed to also be suitable for strengthening beams with carbon fiber sheets since typically strengthening beams compromise 98% by volume of reinforced concrete. Flexural capacity of strengthening beam is absolutely dependent upon the type of reinforcement materials, amount of reinforcement, anchoring system, adhesion capacity between reinforcement material and concrete. Therefore, it might be incorrect to use strength method for analysis and design of strengthening beam without considering the differences in the load-deflection curves, mechanism of failure, state of stress distribution, failure strain of the reinforcement. An flexural analysis based on force equilibrium and strain comparability has been developed for strengthening beam. Systematic experimental investigations are compared with analytical results. Then, the adaptation of strength method for strengthening beam have also been discussed.

  • PDF

최소철근량 이하로 보강된 강섬유보강 보의 휨성능 고찰 (A Study on the Flexural Performance of Steel Fiber-Reinforced Beams lightly Reinforced Below the Minimum Steel Reinforcement)

  • 강덕만;박용걸;문도영
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제21권3호
    • /
    • pp.35-44
    • /
    • 2017
  • 본 연구에서는 국내 콘크리트구조기준(2012)에서 규정하고 있는 최소철근량 이하로 보강된 보에 강섬유를 혼입한 강섬유보강철근콘크리트보의 휨파괴 실험을 수행하였다. 실험변수는 철근비와 강섬유의 혼입량으로 하였다. 철근보강비는 최소철근량의 44%, 66%, 78%와 100%로 하였으며, 강섬유의 혼입량은 0.25%, 0.50%, 0.75% 및 1.00%이다. 실험결과, 강섬유는 균열저항성능을 크게 개선시키는 것으로 확인되었다. 또한, 하중저항성능의 관점에서 강섬유는 항복하중의 증가에 기여하지만 극한하중의 증가에는 거의 기여하지 못하는 것을 확인하였다. 강섬유로 인한 항복하중의 증가량은 철근 감소로 인한 항복하중의 감소량에 비하여 미미한 것으로 나타났다. 최소철근보에서 강섬유의 사용은 오히려 연성을 크게 감소시키는 것으로 확인되었다. 따라서 최소철근 휨부재에 강섬유를 사용하기 위해서는 연성도 확보를 위하여 철근비를 증가시켜야 하는 것으로 확인되었다.

강섬유 보강 고강도 철근 콘크리트 보-기둥 접합부의 이력 거동에 관한 연구 (A Study on the Hysteretic Behavior of High Strength Steel Fiber Reinforced Concrete Beam-Column Joint)

  • 오경남;이정한;유영찬;이원호;정헌수
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 1999년도 학회창립 10주년 기념 1999년도 가을 학술발표회 논문집
    • /
    • pp.533-536
    • /
    • 1999
  • The primary purpose of this study is to investigate experimentally the effect of steel fiber reinforcement on the total energy dissipation capacity of R/C flexural members and to make a contribution to the construction of 40~60 story R/C high rise building by developing the new materials and reinforcing details which can improve the seismic performance of high-strength R/C beam-column joints. Experimental research was carried out on 4 type specimen under cyclic loading. Main variables are steel fiber reinforcement, intermediate reinforcements and yield strength of rebars. From the test results, steel fiber reinforcement can improve the ductility of R/C flexural members.

  • PDF

하이브리드 FRP 리바의 역학적 특성 (Mechanical Properties of Hybrid FRP Rebar)

  • 박찬기;원종필
    • 한국농공학회지
    • /
    • 제45권2호
    • /
    • pp.58-67
    • /
    • 2003
  • Over the last decade fiber-reinforced polymer (FRP) reinforcement consisting of glass, carbon, or aramid fibers embedded in a resin such as vinyl ester, epoxy, or polyester has emerged as one of the most promising and affordable solutions to the corrosion problems of steel reinforcement in structural concrete. But reinforcing rebar for concrete made of FRP rebar has linear elastic behavior up to tensile failure. For safety a certain plastic strain and an elongation greater than 3% at maximum load is usually required for steel reinforcement in concrete structures. The same should be required for FRP rebar. Thus, the main object of this study was to develop new type of hybrid FRP rebar Also, this study was evaluated to the mechanical properties of Hybrid FRP rebar. The Manufacture of the hybrid FRP rebar was achieved by pultrusion, and braiding and filament winding techniques. Tensile and interlaminar shear test results of Hybrid FRP rebar can provide its excellent tensile strength-strain behavior and interlaminar stress-strain behavior.

폴리아미드 섬유보강 초고강도(160MPa) 콘크리트의 내화성능 (Fire Resistance of Reinforced Polyamide Fiber Ultra High Strength(160MPa) Concrete)

  • 전중규;전찬기;김수영;김복규;김필성;윤경호
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2009년도 춘계 학술대회 제21권1호
    • /
    • pp.547-548
    • /
    • 2009
  • 분산제 코팅 및 단일형상을 가진 폴리아미드 섬유보강 콘크리트 기술을 적용하여 160MPa 초고강도 콘크리트의 내화성능을 평가한 결과, 콘크리트의 압송성능을 개선했을 뿐만 아니라 콘크리트의 내화성능 관리기준을 만족하였다.

  • PDF

Nonlinear responses of energy storage pile foundations with fiber reinforced concrete

  • Tulebekova, Saule;Zhang, Dichuan;Lee, Deuckhang;Kim, Jong R.;Barissov, Temirlan;Tsoy, Viktoriya
    • Structural Engineering and Mechanics
    • /
    • 제71권4호
    • /
    • pp.363-375
    • /
    • 2019
  • A renewable energy storage pile foundation system is being developed through a multi-disciplinary research project. This system intends to use reinforced concrete pile foundations configured with hollowed sections to store renewable energy generated from solar panels attached to building structures in the form of compressed air. However previous research indicates that the compressed air will generate considerable high circumferential tensile stresses in the concrete pile, which requires unrealistic high hoop reinforcement ratio to avoid leakage of the compressed air. One possible solution is to utilize fiber reinforced concrete instead of placing the hoop reinforcement to resist the tensile stress. This paper investigates nonlinear structural responses and post-cracking behavior of the fiber reinforced concrete pile subjected to high air pressure through nonlinear finite element simulations. Concrete damage plasticity models were used in the simulation. Several parameters were considered in the study including concrete grade, fiber content, and thickness of the pile section. The air pressures which the pile can resist at different crack depths along the pile section were identified. Design recommendations were provided for the energy storage pile foundation using the fiber reinforced concrete.

고강도 RC 기둥의 전단능력 증진을 위한 강섬유 보강 (Steel Fiber Reinforcement for Shear Capacity Enhancement of High Strength RC Columns)

  • 장극관;이현호;문상덕
    • 한국콘크리트학회:학술대회논문집
    • /
    • 한국콘크리트학회 2002년도 봄 학술발표회 논문집
    • /
    • pp.469-474
    • /
    • 2002
  • This study was to define the strengthening effect of steel fibers in high strength RC columns. For this, ten specimens of columns were tested under cyclic lateral load and constant axial load. The testing parameters are steel fiber volume fraction of concrete and shear reinforcement ratio of hoop bars. Finally, the optimal content of steel fibers was evaluated as 1.0 - 1.5 % volume fraction of concrete.

  • PDF

Parametric study of shear capacity of beams having GFRP reinforcement

  • Vora, Tarak P.;Shah, Bharat J.
    • Advances in concrete construction
    • /
    • 제13권 2호
    • /
    • pp.183-190
    • /
    • 2022
  • A wide range of experimental bases and improved performance with different forms of Fiber Reinforced Polymer (FRP) have attracted researchers to produce eco-friendly and sustainable structures. The reinforced concrete (RC) beam's shear capacity has remained a complex phenomenon because of various parameters affecting. Design recommendations for the shear capacity of RC elements having FRP reinforcement need a more experimental database to improve design recommendations because almost all the recommendations replace different parameters with FRP's. Steel and FRP are fundamentally different materials. One is ductile and isotropic, whereas the other is brittle and orthotropic. This paper presents experimental results of the investigation on the beams with glass fiber reinforced polymer (GFRP) reinforcement as longitudinal bars and stirrups. Total twelve beams with GFRP reinforcement were prepared and tested. The cross-section of the beams was rectangular of size 230 × 300 mm, and the total length was 2000 mm with a span of 1800 mm. The beams are designed for simply-supported conditions with the two-point load as per specified load positions for different beams. Flexural reinforcement provided is for the balanced conditions as the beams were supposed to test for shear. Two main variables, such as shear span and spacing of stirrups, were incorporated. The beams were designed as per American Concrete Institute (ACI) ACI 440.1R-15. Relation of VExp./VPred. is derived with axial stiffness, span to depth ratio, and stirrups spacing, from which it is observed that current design provisions provide overestimation, particularly at lower stirrups spacing.

강섬유보강 콘크리트와 일반 콘크리트 합성보의 전단강도 (Shear Strength of Steel Fiber Concrete - Plain Concrete Composite Beams)

  • 김철구;박홍근;홍건호;강수민
    • 콘크리트학회논문집
    • /
    • 제27권5호
    • /
    • pp.501-510
    • /
    • 2015
  • 최근 프리캐스트 콘크리트에 현장타설 콘크리트를 타설하는 복합화 공법의 사용이 증가하고 있다. 강섬유 콘크리트는 습식공법에서는 시공성 문제로 적용이 어렵지만, 공장에서 선 제작이 이뤄지는 프리캐스트 부재에는 충분히 사용 가능하다. 강섬유 콘크리트가 복합화 공법에 사용되면 서로 재료적 특성이 다른 강섬유 콘크리트와 일반 콘크리트 합성단면의 전단강도 산정법이 문제가 되고 있다. 하지만 현행 기준은 명확한 기준을 제시하지 못하고 있는 실정이다. 따라서 강섬유 콘크리트가 사용된 합성 부재의 전단강도 실험을 통해 강섬유 콘크리트가 합성단면의 전단강도에 미치는 영향을 살펴보았다. 실험 변수로는 합성단면적비와 전단철근비를 고려하였다. 실험결과를 살펴보면, 강섬유가 인장대에 보강된 경우 강섬유 보강 단면적에 비례하여 전단강도가 증가하였다. 하지만 강섬유의 영향으로 인해 계면에서 수평전단파괴가 쉽게 발생하기 때문에 최소 수평전단철근이 반드시 필요하다.

콘크리트의 휨성능 증진 및 균열제어에 대한 특수 가공된 셀룰로오스섬유의 효과 (Effects of Specialty Cellulose Fibers on Improvement of Flexural Performance and Control of Cracking of Concrete)

  • 원종필;박찬기
    • 콘크리트학회논문집
    • /
    • 제12권2호
    • /
    • pp.89-98
    • /
    • 2000
  • The mechanical properties of specialty cellulose fiber reinforced concrete and the contribution of specialty cellulose fiber to drying shrinkage crack reduction potential of concrete and theirs evaluation are presented in this paper. The effects of differing fiber volume fraction(0.03%, 0.06%, 0.08%, 0.1%, 0.15%, 0.2%) were studied. The results of tests of the specialty cellulose fiber reinforced concrete were compared with plain and polypropylene fiber reinforced concrete. Flexural performance(flexural strength and flexural toughness) test results indicated that specialty cellulose fiber reinforcement showed an ability to increase the flexural performance of normal- and high- strength concrete(as compared to plain and polypropylene fiber reinforced concrete). Optimum specialty cellulose fiber reinforced concrete were obtianed using 0.08% fiber volume fraction. Drying shrinkage cracking test results confirmed specialty cellulose fibers are effective in reducing the drying shrinkage cracking of normal and high-strength concrete(as compared to popylene fiber reinforced concrete).