• Title/Summary/Keyword: Fiber optical sensor

Search Result 727, Processing Time 0.022 seconds

Multiplexed Bend Loss Type Single-Mode Fiber-Optic Displacement Sensor Using Reflection Signals Generated at Optical Connectors (광커넥터의 반사를 이용한 다중화된 굽힘 손실형 단일모드 광섬유 변위센서)

  • Yoo Jung-Ae;Jo Jae Heung;Kwon Il-Bum
    • Korean Journal of Optics and Photonics
    • /
    • v.15 no.5
    • /
    • pp.415-422
    • /
    • 2004
  • We propose and present a new multiplexed bend loss type single-mode fiber-optic sensor system for displacement measurement in order to measure the displacement of several mm of civil engineering structures such as bridges and buildings. We make a bend loss type fiber-optic sensor for measuring displacements using the signal difference between two reflection signals due to various bend losses generating at a pair of optical connectors by using the optical time domain reflectometer. And we fabricate a multiplexed bend loss type fiber-optic sensor detecting linear displacements of 4 measuring positions of an object by setting these new 4 fiber-optic sensors on a single mode fiber simultaneously. We find that the multiplexed fiber-optics displacement sensor has linearity of 0.9942, maximum displacement of 6 mm, and accuracy of 6% for 4 measuring points.

Development of Optical Fiber Glucose and Lactate Biosensors for Bioprocess Monitoring (생물공정 모니터링을 위한 광섬유 포도당 및 젖산 센서의 개발)

  • Jung, Chang Hwan;Sohn, Ok-Jae;Rhee, Jong Il
    • KSBB Journal
    • /
    • v.32 no.1
    • /
    • pp.35-45
    • /
    • 2017
  • In this work the optical fiber glucose and lactate biosensors were developed by using fluorescent dye and enzyme immobilized on the end tip of an optical fiber. 3-Glycidyloxypropyl)methyldiethoxysilane (GPTMS), (3-Aminopropyl) trimethoxysilane (APTMS) and Methyltrimethoxysilane (MTMS) were used to immobilize glucose oxidase (GOD), lactate oxidase (LOD) and ruthenium(II) complex (tris(4,7-diphenyl-1,10-phenanthroline) ruthenium(II), $Ru(dpp)_3^{2+}$) as oxygen sensitive fluorescent dye. MTMS sol-gel was an excellent supporting material for the immobilization of $Ru(dpp)_3^{2+}$, GOD, and LOD on the optical fiber. Storage stability of the optical fiber glucose sensor was kept constant over 20 days, while the optical fiber lactate sensor had constant storage stability over 17 days. The optical fiber glucose and lactate biosensors also maintained good operational stability for 20 hours and 14 hours, respectively. The activities of the immobilized enzymes were most excellent at pH 7 and at $25^{\circ}C$. On-line monitoring of glucose and lactate in a simulated process was performed with the optical fiber glucose and lactate biosensors. On-line monitoring results were agreed with those of off-line data measured with high performance liquid chromatography (HPLC).

Detection of Partial Discharge Acoustic Signal Using the Optical Fiber Interferometric Sensor (광섬유 간섭계 센서를 이용한 부분방전 음압 측정)

  • 이종길;박윤석;이준호
    • The Journal of the Acoustical Society of Korea
    • /
    • v.21 no.7
    • /
    • pp.614-623
    • /
    • 2002
  • In this paper, it was manufactured an interferometric optical fiber sensor and measured partial discharge acoustic signal caused by defect of power facilities such as power cables, transformers and gas insulation. Acrylic and aluminium mandrels wound with fiber-optic were chosen as optical fiber sensor, Sagnac and Mach-Zehnder interferometers were chosen to detect discharge acoustic signals. The two fiber optic interferometers were identified by using the PZT. Discharge experimentation set in the discharge imitation cell in oil tank and the discharge phenomena was generated. Based on the experimental result, to detect the discharge acoustic signal, Sagnac interferometer can detect stably the acoustic signal than the Mach-Zehnder interferometer. It is shown that Sagnac optical fiber sensor can detect the discharge acoustic signals effectively.

Optical Sensor Based on Evanescent Field Coupling Between Side-Polished Polarization Maintaining Fiber and Planar Waveguide Coupler (측면 연마 편광 유지 광섬유와 평면 도파로 사이의 소산장 결합을 이용한 광센서)

  • Kim, Kwang-Taek;HwangBo, Sueng;Kang, Yong-Chul
    • Journal of Sensor Science and Technology
    • /
    • v.13 no.3
    • /
    • pp.207-212
    • /
    • 2004
  • We have investigated the optical characteristics of a directional coupler made of a side-polished polarization maintaining fiber in contact with a multimode planar waveguide and its applications as sensors. A device structural condition to achieve the polarization insensitive wavelength response has been presented. The fabricated devices revealed a superior immunity to the bending and the deformation of PM fibers in the input section. It is experimentally shown that the proposed device is suitable for a remote fiber sensor.

Development of Fiber Optic BOTDA Sensor (광섬유 BOTDA 센서의 개발)

  • 권일범;최만용;유재왕;백세종
    • Korean Journal of Optics and Photonics
    • /
    • v.12 no.4
    • /
    • pp.294-299
    • /
    • 2001
  • Recently great efforts and investment have been made in order to develop a structural health monitoring technology using fiber optic sensors. Therefore, in this study, we have focused on the development of a fiber optic BOTDA (Brillouin Optical Time Domain Analysis) sensor system in order to measure strains distributed on large structures by an optical fiber. The fiber optic BOTDA sensor was constructed simply, with only two electro-optic modulators. The results of strain measurement tests of an optical fiber showed that the strain can be determined accurately from the Brillouin frequency shift measurement on the strain induced range of 10 m in the total fiber length of 4.8 kIn using 200 averaged signals. Also, the strain sensitivity of Samsung single mode fiber was 4.81 MHz/O.Ol % under the test. test.

  • PDF

Strain Analysis in GFRP Cross-Ply Laminates Using TR-EFPI Optical Fiber Sensor (광섬유 TR-EFPI 센서를 이용한 GFRP 직교 적층판의 변형률 해석)

  • 우성충;최낙삼;권일범
    • Proceedings of the Korean Society For Composite Materials Conference
    • /
    • 2003.10a
    • /
    • pp.150-153
    • /
    • 2003
  • Longitudinal strains({$varepsilon}_x$) of the core and skin layers in glass fiber reinforced plastic(GFRP) cross-ply composite laminates have been studied using the embedded optical fiber sensor of totally-reflected extrinsic Fabry-Perot interferometer(TR-EFPI). Foil-type strain gauges bonded on both the upper and lower surfaces were used for the measurement of the surface strains. Both TR-EFPI sensor and strain gauge bonded on the specimen surface showed excellent agreement within -0.0086 ~ +0.0302% strain. It was shown that values of {$varepsilon}_x$ in the interior of the surface layer and the core layer measured by embedded TR-EFPI sensor was significantly higher than that of the specimen surface measured by strain gauges. The experimental results were ascertained with finite element analysis. Embedded TR-EFPI optical fiber sensor could measure accurately the internal strains which were different from the surface.

  • PDF

A study of fiber optic intrusion sensor system using the speckle patterns (스페클 패턴을 이용한 광섬유 침입자 센서 시스템에 대한 연구)

  • 김인수;박재희
    • Korean Journal of Optics and Photonics
    • /
    • v.14 no.3
    • /
    • pp.230-235
    • /
    • 2003
  • A fiber optic intrusion sensor system using the variations of speckle patterns was developed. The intrusion sensor system consisted of an analog unit, a digital control unit, and a DSP unit. Some experiments were carried out using a 500 m length optical fiber sensor. The system detected intruders without missing, and distinguished between cars and persons. When the intruders were cars, the discrimination probability was 100% and when the intruders were persons, the discrimination probability was 90%.

Sensor Mat using POF for Medical Application (의료용 플라스틱 광섬유 센서 매트)

  • Choi, Kyoo-Nam
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.44 no.4 s.316
    • /
    • pp.74-78
    • /
    • 2007
  • Novel concept of sensor mat and its signal processing method is proposed for patient monitoring in medical application. Proposed sensor mat structure has sensing inner layer which has cross-linked arrangement using plastic optical fiber(POF). Large core diameter of plastic optical fiber behaved as band pass filter by averaging the noise component caused by unwanted environmental factors. Signal processor followed by sensor output added noise immune performance by filtering out unwanted component. Fail-proof patient breath monitoring scheme was realized by using intelligent decision algorithm. Unlike the conventional approach by using mechanical sensor, which have high sensitivity both to signal and to environmental noise, our approach provided reliable breath motion detection.

Implementation of Stimulated Brillouin Scattering in Optical Fiber Sensor for Improved Stability by Using Neuro-Fuzzy Theory (뉴로-퍼지 알고리즘을 적용한 광파이버 유도 브릴루앙 산란 센서의 신뢰도 향상에 관한 연구)

  • Hwang, Kyoung-Jun;Yeom, Keong-Tae;Kim, Yong-Kab
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.57 no.1
    • /
    • pp.92-97
    • /
    • 2008
  • This is a research to apply 1310nm single-mode optical fiber to a temperature sensor. The existing study of optical fiber sensor is complicated because it was made with various equipment. To vary scattering, the variation of optical frequency is measured by using Bragg(lattice) or pulse generator and also bulk system is created by YAG laser but there were some difficulties creating experimental environment and it was a problem that the stability of measured data was low. The temperature sensor system using the suggested sBs(stimulated Brillouin scattering:sBs) from this research is much more simplified straight-line system. To improve the trust and accuracy of noises from optical frequency and unclear results, it was analysed by using Neuro-Fuzzy algorithm. we tried to get more correct data than existing system. sBs measure that optical frequency changed due to the variation of temperature. The analyzed change rate of outcome by Fuzzy theory is 1.1 MHz.

Characterization of both adhesion and interfacial interaction between optical fiber coating and structural

  • Brotzu, A.;Felli, F.;Fiori, L.;Caponero, M.A.
    • Smart Structures and Systems
    • /
    • v.4 no.4
    • /
    • pp.439-448
    • /
    • 2008
  • Optical fiber sensors are by now broadly accepted as an innovative and reliable device for structural health monitoring, to be used either embedded into or bonded on structures. The accuracy of the strain measurement achievable by optical fiber sensors is critically dependent on the characteristics of the bonding of the various interface layers involved in the sensor bonding/embedding (structure material and gluing agent, fiber coating and gluing agent, fiber coating and fiber core). In fact, the signal of the bonded/embedded optical fiber sensor must correspond to the strain experienced by the monitored structure, but the quality of each involved interface can affect the strain transfer. This paper faces the characterization, carried on by both mechanical tests and morphological analysis, of the strain transfer function resulting with epoxidic and vinylester gluing agent on polyimide and acrylate coated optical fibers.