• 제목/요약/키워드: Fiber optic sensor

검색결과 518건 처리시간 0.03초

광전류/광전압 센서의 일체화 설계에 관한 연구 (A study on single body design of optical current sensor and optical voltage sensor)

  • 김영수;김요희
    • 한국통신학회논문지
    • /
    • 제21권6호
    • /
    • pp.1596-1603
    • /
    • 1996
  • A single body type of fiber-optic current and voltae sensor using a rare earth doped YIG and a bismuth silicon oxide single crystsl is proposed, which is used for simultaneous measurement of the AC electric current and AC electric voltage over the trasmission lines. Experimental results showed that the fiber-optic current sensor has the maximum 7.5% error within the current range of 0A to 400A, and the fiber-optic voltage sensor has the maximum 0.87% error within the current range of 0V to 400V. The output waveforms of proposed fiber-optic sensor system has a good agreement with output waveforms of conductor current and voltage. Experimental results proved that the output of fiber-optic current sensor is not affected by the electric voltage applied to the fiber-optic voltage sensor, and also, that the output of fiber-optic voltage sensor is not affected by the electric current applied to the fiber-optic current sensor.

  • PDF

A Fiber Optic Sensor for Determination of 2,4-Dichlorophenol Based on Oxygen Oxidation Catalyzed by Iron(III) Tetrasulfophthalocyanine

  • Tong, Yilin;Li, Dapeng;Huang, Jun;Zhang, Cong;Li, Kun;Ding, Liyun
    • Bulletin of the Korean Chemical Society
    • /
    • 제34권11호
    • /
    • pp.3307-3311
    • /
    • 2013
  • A new fiber optical sensor was developed for the determination of 2,4-dichlorophenol (DCP). The sensor was based on DCP oxidation by oxygen with the catalysis of iron(III) tetrasulfophthalocyanine (Fe(III)PcTs). The optical oxygen sensing film with $Ru(bpy)_3Cl_2$ as the fluorescence indicator was used to determine the consumption of oxygen in solution. A lock-in amplifier was used for detecting the lifetime of the oxygen sensing film by measuring the phase delay change of the sensor head. The different variables affecting the sensor performance were evaluated and optimized. Under the optimal conditions (i.e. pH 6.0, $25^{\circ}C$, Fe(III)PcTs concentration of 0.62 mg/mL), the linear detection range and response time of the sensor are $1.0{\times}10^{-6}-9.0{\times}10^{-6}$ mol/L and 250 s, respectively. The sensor displays high selectivity, good repeatability and stability, and can be used as an effective tool in analyzing DCP concentration in practical samples.

측정대상물의 표면조도에 따른 광파이버 센서 특성고찰 (The Characteristics of Fiber Optic Sensor on the Surface Roughness of Target)

  • 박한수;정택구;홍준희;이동주
    • 한국정밀공학회:학술대회논문집
    • /
    • 한국정밀공학회 2002년도 춘계학술대회 논문집
    • /
    • pp.283-286
    • /
    • 2002
  • In fiber optic sensor, the error of the measurement is influenced by the surface roughness of the target and surroundings, especially the outside light. To reduce or modify this error, the sensitivity of the fiber optic sensor and the noise change by the surface roughness of the target should be known. The purpose of this paper is to observe the sensitivity of the fiber optic sensor and the noise according to the surface roughness of the target.

  • PDF

광섬유 압력센서 (Fiber optic pressure sensor)

  • 이기완;배준형
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 1996년도 한국자동제어학술회의논문집(국내학술편); 포항공과대학교, 포항; 24-26 Oct. 1996
    • /
    • pp.640-643
    • /
    • 1996
  • In this paper, a sensitivity of the fiber optic pressure sensor in water is demonstrated. A single mode optical fiber Mach-Zehnder interferometer used to detect the change in optical path length produced by the change of fiber optic strain in water. The sensitivity with this system measured 100.mu.psia through an experiment in the static response.

  • PDF

빌딩표면에 분포된 온도를 측정하기 위한 광섬유 BOTDA센서의 적용 (Application of fiber optic BOTDA sensor for measuring the temperature distributed on the surfaces of a building)

  • Kwon, Il-Bum;Kim, Chi-Yeop;Park, Man-Yong
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 2002년도 가을 학술발표회 논문집
    • /
    • pp.505-510
    • /
    • 2002
  • We have focused on the development of a fiber optic BOTDA (Brillouin Optical Time Domain Analysis) sensor system in order to measure temperature distributed on large structures. Also, we present a feasibility study of the fiber optic sensor to monitor the distributed temperature on a building construction. A fiber optic BOTDA sensor system, which has a capability of measuring the temperature distribution, attempted over several kilometers of long fiber paths. This simple fiber optic sensor system employs a laser diode and two electro-optic modulators. The optical fiber of the length of 1400 m was installed on the surfaces of the building. The change of the distributed temperature on the building construction was well measured by this fiber optic sensor. The temperature changed normally up to 4℃ through one day.

  • PDF

Fiber-Optic Temperature Sensor Based on Single Mode Fused Fiber Coupler

  • Kim, Kwang-Taek;Park, Kiu-Ha
    • Journal of the Optical Society of Korea
    • /
    • 제12권3호
    • /
    • pp.152-156
    • /
    • 2008
  • This paper reports a fiber-optic temperature sensor using a single mode fused fiber coupler incorporating a thermo-optic external medium. The spectral transmission was altered by changing the refractive index of the external thermo-optic medium. A theoretical and experimental investigation was carried out with the aim of achieving high sensitivity. The measured sensitivity for the environmental temperature was as high as -1.5 $nm/^{\circ}C$.

PMMA가 코팅된 주름 구조를 갖는 다공성규소 격판을 이용한 광섬유 압력센서 (Fiber-Optic Pressure Sensor Using a Rugate-Structured Porous Silicon Diaphragm Coated with PMMA)

  • 이기원;조소연
    • 센서학회지
    • /
    • 제22권3호
    • /
    • pp.227-232
    • /
    • 2013
  • In this research, fiber-optic pressure sensors were fabricated with rugate-structured porous silicon (RPS) diaphragms coated with PMMA (Polymethyl-Methacrylate). The reflectance spectrum of the PMMA/RPS diaphragm was almost the same as that of uncoated RPS diaphragm. However the mechanical strength of the PMMA/RPS diaphragm increased more than that of the uncoated diaphragm. As a result, the fiber-optic sensor fabricated with PMMA/RPS diaphragm could successfully detect more high pressure difference without diaphragm damage than the highest detectable pressure difference of the sensor with normal RPS diaphragm. The response data of the fiber-optic sensor recorded as a function of pressure difference were fitted by theoretical curves. During this process, elastic moduli of the used PMMA/RPS diaphragms were obtained numerically. The dynamic response properties of the fiber-optic sensor were also investigated under continuous variation of the pressure difference conditions.

Sagnac형 광섬유 배열센서를 이용한 유증 음답 탐지 연구 (Investigation of the Acoustic Detection in Transformer Oil Using Sagnac Fiber Optic Sensor Array)

  • 이종길;이승홍
    • 한국소음진동공학회:학술대회논문집
    • /
    • 한국소음진동공학회 2010년도 추계학술대회 논문집
    • /
    • pp.533-534
    • /
    • 2010
  • Fiber optic sensor has bee widely used in the industrial applications. For the application of acoustic detection of the high voltage electric transformer Sagnac interferometer can be used. In this paper several different materials of mandrel were used in the fiber sensor array. Based on the transformer oil fiber optic sensor is more sensitive than in the air.

  • PDF

광섬유 브래그 격자 센서의 변형률 감지도 (Strain Sensitivity of Fiber Optic Bragg Grating Sensor)

  • 권일범;최만용;김민수
    • 한국구조물진단유지관리공학회 논문집
    • /
    • 제3권3호
    • /
    • pp.237-243
    • /
    • 1999
  • Recently, there has been considerable interest in the development of fiber-optic sensors based on fiber Bragg gratings (FBGs), which can be made into Ge-doped fiber's core by UV phase mask or holographic methods. A good sensitivity and small size of this sensor make it an ideal candidate for distributed sensing in smart structures or other structural monitoring applications. In this study, fiber optic Bragg grating sensor, which could be applied to measure the absolute strains, was constructed and the strain sensitivity of this sensor was investigated in order to apply to the structural health monitoring. Fiber Fabry-Perot (FFP) filter has been used to detect the optical signals instead of optical spectrum analyzer. It has been convenient to determine the structural strains from the output signal of FBGs. The fiber optic Bragg grating sensor was attached on the aluminum beam near the electrical strain gage to measure the same strain. The relationship between strain and fiber signal was linearly fitted. The strain sensitivity of the fiber optic Bragg grating sensor was determined as $l.57{\mu}{\varepsilon}/{\mu}sec$ from the aluminum beam test.

  • PDF

양단이 지지된 Fabry-Perot 광섬유센서의 음압 감지 특성 연구 (Sound Detection Characteristics Using Fabry-Perot Fiber Optic Sensor which Simply Supported in Structure)

  • 이종길;이진우;이준호
    • 한국음향학회지
    • /
    • 제22권7호
    • /
    • pp.585-591
    • /
    • 2003
  • 본 연구에서는 소형화 및 경량화의 특성을 가진 Fabry-Perot형 간섭계를 구성하였다. 음향이 광섬유의 횡방향으로 감지되도록 센서 헤드부를 1㎝정도로 제작하고 총 길이가 9.5㎝인 광섬유의 양단을 단순 지지토록 하였다. 센서의 음향 감지특성을 관찰하기 위하여 무지향성 스피커를 이용하여 음향신호를 인가하였다 횡방향으로 입력된 음향 신호를 광섬유 센서와 마이크로폰이 감지한 신호를 비교하였다. 1㎑ 이하의 신호에서는 광섬유 센서가 마이크로폰보다 감지 특성이 좋으나 2 ㎑에서는 광섬유센서의 감지 특성이 감소하였다. 이것은 제작된 광섬유 센서의 지지구조의 특성을 나타낸 것이며 실험을 통하여 Fabry-Perot 간섭계용 센서는 횡방향의 음향을 잘 감지함을 확인하였다. 이러한 형태의 센서는 지능구조물의 건강진단 모니터링 분야에도 적용가능 하리라 판단된다.