• Title/Summary/Keyword: Fiber optic probe

Search Result 64, Processing Time 0.027 seconds

Fabrication and Characterization of a One-dimensional Fiber-optic Dosimeter for Electron Beam Therapy Dosimetry (치료용 전자선 계측을 위한 1차원 광섬유 방사선량계의 제작 및 특성분석)

  • Jang, Kyoung-Won;Cho, Dong-Hyun;Shin, Sang-Hun;Yoo, Wook-Jae;Jun, Jae-Hun;Lee, Bong-Soo;Moon, Joo-Hyun;Park, Byung-Gi
    • Progress in Medical Physics
    • /
    • v.19 no.4
    • /
    • pp.285-290
    • /
    • 2008
  • In this study, we have fabricated a one-dimensional fiber-optic dosimeter for electron beam therapy dosimetry. Each fiber-optic dosimeter has an organic scintillator with a plastic optical fiber and it is embedded and arrayed in the plastic phantom to measure one-dimensional high energy electron beam profile of clinical linear accelerator. The scintillating lights generated from each sensor probe are guided by plastic optical fibers to the multi-channel photodiode amplifier system. We have measured one-dimensional electron beam profiles in a PMMA phantom according to different field sizes and energies of electron beam. Also, the isodose and three-dimensional percent depth dose curves in a PMMA phantom are obtained using a one-dimensional fiber-optic dosimeter with different electron beam energies.

  • PDF

CHALLENGING APPLICATIONS FOR FT-NIR SPECTROSCOPY

  • Goode, Jon G.;Londhe, Sameer;Dejesus, Steve;Wang, Qian
    • Proceedings of the Korean Society of Near Infrared Spectroscopy Conference
    • /
    • 2001.06a
    • /
    • pp.4112-4112
    • /
    • 2001
  • The feasibility of NIR spectroscopy as a quick and nondestructive method for quality control of uniformity of coating thickness of pharmaceutical tablets was investigated. Near infrared spectra of a set of pharmaceutical tablets with varying coating thickness were measured with a diffuse reflectance fiber optic probe connected to a Broker IFS 28/N FT-NIR spectrometer. The challenging issues encountered in this study included: 1. The similarity of the formulation of the core and coating materials, 2. The lack of sufficient calibration samples and 3. The non-linear relationship between the NIR spectral intensity and coating: thickness. A peak at 7184 $cm^{-1}$ was identified that differed for the coating material and the core material when M spectra were collected at 2 $cm^{-1}$ resolution (0.4 nm at 7184 $cm^{-1}$). The study showed that the coating thickness can be analyzed by polynomial fitting of the peak area of the selected peak, while least squares calibration of the same data failed due to the lack of availability of sufficient calibration samples. Samples of coal powder and solid pieces of coal were analyzed by FT-NIR diffuse reflectance spectroscopy with the goal of predicting their ash content, percentage of volatile components, and energy content. The measurements were performed on a Broker Vector 22N spectrometer with a fiber optic probe. A partial least squares model was constructed for each of the parameters of interest for solid and powdered sample forms separately. Calibration models varied in size from 4 to 10 PLS ranks. Correlation coefficients for these models ranged from 86.6 to 95.0%, with root-mean-square errors of cross validation comparable to the corresponding reference measurement methods. The use of FT-NIR diffuse reflectance measurement techniques was found to be a significant improvement over existing measurement methodologies in terms of speed and ease of use, while maintaining the desired accuracy for all parameters and sample forms.(Figure Omitted).

  • PDF

A Study on the Analysis of Ciliary Beat Frequency in Human Respiratory Tract n Vivo (레이저 산란 기법을 이용한 인체 기도 내 섬모 운동 신호의 분석에 관한 연구)

  • 이원진;이재서;이재서;이철희;권태영
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.4
    • /
    • pp.339-344
    • /
    • 2000
  • The mucociliary system is one of the most important airway defense mechanisms in human body and impairment of ciliary movement results in various diseases in respiratory tract. In this study, we have developed a system that can measure ciliary movement in vivo and quantified ciliary beat frequency (CBF) through autoregressive (AR) power spectrum. To measure the frequency in vivo, we applied a photoelectric method that was composed of a laser light and a fiber optic probe. Scattered signals are transferred to a PC in which they are displayed on the monitor and its CBF is determined by the AR method in were acquired. For 8 normal subjects, the analyzed CBFs ranged from 5 to 10Hz and its mean was 7.3${\pm}$1.1Hz. This result showed similar aspects to the reported results of CBFs to data. We expect that this result will be applied in various clinical studies such as analysis of CBF changes by drugs or by diseaes.

  • PDF

Graphene Coated Optical Fiber SPR Biosensor

  • Kim, Jang Ah;Hwang, Taehyun;Dugasani, Sreekantha Reddy;Kulkarni, Atul;Park, Sung Ha;Kim, Taesung
    • Proceedings of the Korean Vacuum Society Conference
    • /
    • 2014.02a
    • /
    • pp.401-401
    • /
    • 2014
  • In this study, graphene, the most attractive material today, has been applied to the wavelength-modulated surface plasmon resonance (SPR) sensor. The optical fiber sensor technology is the most fascinating topic because of its several benefits. In addition to this, the SPR phenomenon enables the detection of biomaterials to be label-free, highly sensitive, and accurate. Therefore, the optical fiber SPR sensor has powerful advantages to detect biomaterials. Meanwhile, Graphene shows superior mechanical, electrical, and optical characteristics, so that it has tremendous potential to be applied to any applications. Especially, grapheme has tighter confinement plasmon and relatively long propagation distances, so that it can enhance the light-matter interactions (F. H. L. Koppens, et al., Nano Lett., 2011). Accordingly, we coated graphene on the optical fiber probe which we fabricated to compose the wavelength-modulated SPR sensor (Figure 1.). The graphene film was synthesized via thermal chemical vapor deposition (CVD) process. Synthesized graphene was transferred on the core exposed region of fiber optic by lift-off method. Detected analytes were biotinylated double cross-over DNA structure (DXB) and Streptavidin (SA) as the ligand-receptor binding model. The preliminary results showed the SPR signal shifts for the DXB and SA binding rather than the concentration change.

  • PDF

Measurement of Brillouin Backscattering for Distributed Temperature Sensor Applications

  • Kim, Su-Hwan;Kwon, Hyung-Woo;Kwon, Hyun-Ho;Jang, Hang-Seok;Kim, Jee-Hyun;Kang, Shin-Won
    • Journal of Sensor Science and Technology
    • /
    • v.20 no.1
    • /
    • pp.8-13
    • /
    • 2011
  • We present measurements of the Brillouin frequency shift in an optical fiber using a 1550 nm distributed feedback laser diode(DFB-LD) as a light source. By modulating the probe light with an electro-optic modulator, we confirm the stimulated Brillouin gain spectrum(BGS) and spontaneous BGS using the coherent detection method. We also confirm the applicability of the technique to distributed temperature sensors that measure the change in Brillouin frequency shift due to temperature variations.

Fiber Optic Bragg Grating Sensor for Crack Growth Detection of Structures (구조물의 균열 진전 탐지를 위한 광섬유 브래그 격자 센서)

  • Kwon, Il-Bum;Seo, Dae-Cheol;Kim, Chi-Yeop;Yoon, Dong-Jin;Lee, Seung-Seok
    • Journal of the Korean Society for Nondestructive Testing
    • /
    • v.27 no.4
    • /
    • pp.299-304
    • /
    • 2007
  • There are to be some cracks on the material degradation part or the stress concentration parts of the main members, which carry on over-loads, of structures. Because these cracks can be used to evaluate the structural health status, it is important to monitor the crack growth for maintaining the structural safety. In this study, the fiber Bragg grating sensor with a drop ball was developed as a sensor for crack growth detection of an existing crack. The crack growth detection sensor was constructed with three parts: a probe part, a wavelength controling light source and receiver part, and an impact part. The probe part was just formed with a fiber Bragg grating optical fiber The wavelength controling light source part was composed of a current supplying circuit, a DFB laser diode, and a TEC controling circuit for wavelength control. Also, the impact part was just implemented by dropping a steel ball. The performance of this sensor was confirmed by the experiments of the crack detection with an aluminum plate having one existing crack. According to these experiments, the difference of the sensor signal outputs was correlated with the crack length. So, it was confirmed that this sensor could be applied to monitor the crack growth.

Feasibility study on the development of Liquid crystal-optical fiber temperature sensor for minimal invasive laserthermia (LC(Liquid crystal)-광섬유를 이용한 최소 침습적 레이저 온열 치료용 온도 측정 센서의 개발을 위한 기초 연구)

  • Lee, Bong-Soo;Hwang, Young-Muk;Chung, Soon-Cheol
    • Journal of Sensor Science and Technology
    • /
    • v.12 no.5
    • /
    • pp.225-230
    • /
    • 2003
  • Nowadays, laserthermia is widely used to treat malignant tumors with generating heat as the one of minimal invasive surgeries. Generally, the laserthermia probe system consists of the fiber-optic laser and light guides, image guide and temperature sensor. It is very important to measure the temperature of treating tumor and make a stable temperature ($42{\sim}43^{\circ}C$) during the treating time. Therefore, laserthermia probe needs temperature sensor which can measure it exactly and fast. In this study, to develop a new type of temperature sensor with LC(liquid crystal) and optical fiber, the reflectivity of LC according to the temperature changes are measured. Also, the relationships are derived from the results.

A possible optical measuring technique for corona discharge by use of Pockets sensor (광계측 시스템을 이용한 코로나 방전 검출)

  • Kang, Won-Jong;Ma, Ji-Hoon;Chang, Yong-Moo;Koo, Ja-Yoon
    • Proceedings of the KIEE Conference
    • /
    • 2001.07c
    • /
    • pp.1561-1563
    • /
    • 2001
  • In this paper, an novel optical measuring system based on the electro-optic effect has been proposed and realized using Pockels cell with a view to detecting partial discharge taking place at the needle plane electrode. This system has the following advantages ; nonmetallic probe sensor, immune to external EMI noise and broad band response of the Pockels cell from DC to GHz. And also it is constructed by He-Ne laser, optical fiber, $LiNbO_3$ Pockels cell, photo detector, grin lens, oscilloscope and PC. The characteristics of the developed prototype sensor are investigated under AC and corona discharges.

  • PDF

Nondestructive Quantification of Intact Ambroxol Tablet using Near-infrared Spectroscopy (근적외분광분석법을 사용한 암브록솔 정제의 비파괴적 정량분석)

  • 임현량;우영아;김도형;김효진;강신정;최현철;최한곤
    • YAKHAK HOEJI
    • /
    • v.48 no.1
    • /
    • pp.60-64
    • /
    • 2004
  • Near-infrared (NIR) spectroscopy was used to determine rapidly and nondestructively the content of ambroxol in intact ambroxol tablets containing 30 mg (12.5% m/m nominal concentration) by collecting NIR spectra in range 1100-1750 nm. The laboratory-made samples had 10.3∼15.9% m/m nominal ambroxol concentration. The measurements were made by reflection using a fiber-optic probe and calibration was carried out by partial least square regression (PLSR) with autoscaling. Model validation was performed by randomly splitting the data set into calibration and validation data set (7 samples as a calibration data set and 5 samples as a validation data set). The developed NIR method gave results comparable to the known values of tablets in a laboratorial manufacturing Process, standard error of calibration (SEC) and standard error of prediction (SEP) being 0.49% and 0.49% m/m respectively. The method showed good accuracy and repeatability NIR spectroscopic determination in intact tablets allowed the potential use of real time monitoring for a running production process.

Determination of the water content in Citrus leaves by portable near infrared (NIR) system

  • Suh, Eun-Jung;Lim, Hun-Rang;Woo, Young-Ah;Kim, Hyo-Jin
    • Proceedings of the PSK Conference
    • /
    • 2002.10a
    • /
    • pp.405.1-405.1
    • /
    • 2002
  • The amount of water for the cultivation of citrus is different based on the growing period. The water content in the leaves of citrus can be a index for watering during cultivation. The purpose of this study is to determine non-destructively the water content of Citrus leaves by using near infrared spectroscopy (NIRS). Citrus leaves were prepared from satsuma mandarin leaves (Citrus unshiu Marc. var. okitsu) ranging from 62.20 to 69.98% of water content by loss on drying, NIR reflectance spectra of Citrus leaves were acquired by using a fiber optic probe. (omitted)

  • PDF