• Title/Summary/Keyword: Fiber array

Search Result 186, Processing Time 0.031 seconds

Preparation and Analysis of Activated Carbon Fiber from PAN Precursor(II) (PAN 선구체로부터 활성 탄소섬유의 생산과 분석(II))

  • 김진홍;최중열;박병기;정경락;김공주
    • Textile Coloration and Finishing
    • /
    • v.4 no.4
    • /
    • pp.97-103
    • /
    • 1992
  • For manufacturing a high sorptive ACF, we used orthognal array experimental design to get optimum condition. The ability of ACF was measured by $CCl_4$ adsorption and showed those manufacturing conditions were effective in the order of treatment time>oxidative gas>treatment temperature. The optimal condition presented the maximum adsorption rate was at 90$0^{\circ}C$ for 6 minutes with $CO_2$/$H_2O$ gas in the PAN based ACF manufacturing process. The adsorption rate of developed ACF in this experiment was over 100%.

  • PDF

Development of the Planar Active Phased Array Radar System with Real-time Adaptive Beamforming and Signal Processing (실시간으로 적응빔형성 및 신호처리를 수행하는 평면능동위상배열 레이더 시스템 개발)

  • Kim, Kwan Sung;Lee, Min Joon;Jung, Chang Sik;Yeom, Dong Jin
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.15 no.6
    • /
    • pp.812-819
    • /
    • 2012
  • Interference and jamming are becoming increasing concern to a radar system nowdays. AESA(Active Electronically Steered Array) antennas and adaptive beamforming(ABF), in which antenna beam patterns can be modified to reject the interference, offer a potential solution to overcome the problems encountered. In this paper, we've developed a planar active phased array radar system, in which ABF, target detection and tracking algorithm operate in real-time. For the high output power and the low noise figure of the antenna, we've designed the S-band TRMs based on GaN HEMT. For real-time processing, we've used wavelenth division multiplexing technique on fiber optic communication which enables rapid data communication between the antenna and the signal processor. Also, we've implemented the HW and SW architecture of Real-time Signal Processor(RSP) for adaptive beamforming that uses SMI(Sample Matrix Inversion) technique based on MVDR(Minimum Variance Distortionless Response). The performance of this radar system has been verified by near-field and far-field tests.

Novel Coupling Condition between Optical Fiber and Microstrip Antenna in Photonic Antenna (Photonic 안테나에서 광섬유와 마이크로스트립 안테나사이의 새로운 결합조건)

  • Ho Kwang-Chun
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.4 s.346
    • /
    • pp.31-37
    • /
    • 2006
  • Strongly motivated by the need for significant reduction in the optics-to-antenna interface circuitry used in a Photonically controlled array, it has proposed the design development of a novel 'true photonic antenna' consisted of optical fiber and micro-strip antenna. To clarify the design capability of the geometry, modal transmission-line theory including the discontinuity property between circular i,nd planar guiding structures is defined, md the optical power coupling of a slot-coupled microstrip antenna directly fed from an optical fiber using photoconductive effect is evaluated numerically. The numerical results reveal that the maximum power transfer between the two different guiding structures occurs at a new point in which the guiding powers of two rigorous modes are equally partitioned.

Experimental Study for Defects Inspection of CFRP Using Laser-Generated Ultrasound

  • Lee, Joon-Hyun;Park, Won-Su;Byun, Joon-Hyung
    • Proceedings of the Korea Committee for Ocean Resources and Engineering Conference
    • /
    • 2006.11a
    • /
    • pp.41-45
    • /
    • 2006
  • The fabrication process of fiber placement system of carbon fiber reinforced plastic (CFRP) requires real time process control and reliable inspection to ensure quality by preventing defects such as delamination and void. Therefore, novel non-contact inspection technique is required during the non-destructive evaluation in a fiber placement system. For the inspection of delamination in CFRP, various methods to receive laser-generated ultrasound were applied by using piezoelectric transducer, air-coupled transducer, wavelet transform and scanning laser ultrasonic technique. Laser-generated ultrasound was received with a conventional piezoelectric sensor in contacting manner. Then signal characteristics due to defects were analyzed to find a factor for detecting defects. Air-coupled transducer was used for reception of laser-generated guided wave using linear slit array in order to generate high frequency guided wave. And line scan technique was used to confirm the capability of on-line application. The high frequency component of laser-generated guided wave received with piezoelectric sensor disappeared after propagating through delamination region. Nevertheless, it was failed to receive high frequency guided wave in using air-coupled transducer. The first peak of the frequency spectrum under 100kHz in the delamination region is higher than in the sound region. By using this feature, the line scanned frequency data were acquired in fully non-contact generation and reception of ultrasound. This method was proved as useful technique for detecting delamination in CFRP.

  • PDF

A study on the multi-point signal detection, using Passive band-pass filter in FBG Hydrophone (FBG(Fiber Bragg Grating) Hydrophone에서 Passive Band-Pass Filter를 사용한 다중점 신호 검출에 관한 연구)

  • Kim, Kyung-Bok;Kwack, Kea-Dal
    • Journal of Sensor Science and Technology
    • /
    • v.9 no.4
    • /
    • pp.307-315
    • /
    • 2000
  • To set up the arrays system of FBG(Fiber Bragg Grating) Hydrophone sensor and realize the multi-point signal detection for the wide scope underwater, using WDM(Wavelength Division Multiplexing) method and Passive band-pass filter system, underwater acoustic signal detection of the newly designed two FBG Transducers is successfully experimented. As a result of the experiment, it was possible each signal with different frequent signals is detected for the multi-point up to 1.3KHz in underwater. We can, therefore, prove the possibility on the system design of Hydrophone sensor arrays, using the newly made FBG Transducers.

  • PDF

실험계획법을 이용한 탄소섬유/페놀수지의 강화 cycle연구

  • Ha, Heon-Seung;Lee, Jin-Yong;Jo, Dong-Hwan;Yun, Byeong-Il
    • Korean Journal of Materials Research
    • /
    • v.3 no.5
    • /
    • pp.514-520
    • /
    • 1993
  • In this paper the cure cycle of carbon fiber/phenolic resin was investigated by the Taguchi Method in an experimental design. Experiments were systematically performed using $L_{18}(2^1 \times 3_7)$ orthorgonal array table of the experimental design. In the experimental design, eight compression molding parameters (heating rate, pressing temperature, pressing rate, molding pressure, curing temperature, dwell time at curing temperature, cooling rate and degassing) were considered and the effects of the parameters on the flexural strength and the apparent porosity of carbon fiber/phenolic composites were investigated. The analysis of variance for the experimental results indicated that molding pressure and curing temperature are the most significant parmeters in the flexural strength and the apparent porosity of carbon fiber/phenolic resin composites, respectively.

  • PDF

A wavelength readout of a fiber-optic tunable laser using a double-pass Mach-Zehnder Interferometer (더블패스 마하젠더 간섭계를 이용한 광섬유 레이저의 파장검출)

  • Park, Hyong-Jun;Kim, Hyun-Jin;Song, Min-Ho
    • Journal of the Institute of Electronics Engineers of Korea SC
    • /
    • v.46 no.1
    • /
    • pp.43-48
    • /
    • 2009
  • We constructed a simple wavelength readout system for a tunable fiber laser which was used for a fiber Bragg grating sensor array system. A quadrature sampling method was used to demodulate wavelength variations of the tunable laser which consisted of a SOA(semi-conductor optical amplifier) and a fiber-optic Fabry-Perot filter. Internal triggers, which have a 90 degree phase period, have been generated by using a double-pass Mach-Zehnder interferometer. From Lissajous plots with quadrature sampled data, a mean phase error of ${\sim}2.51$ mrad was obtained. From the wavelength readout experiments, an accurate and fast linear wavelength demodulation has been confirmed.

Feasibility Study of Source Position Verification in HDR Brachytherapy Using Scintillating Fiber

  • Moon, Sun Young;Jeong, EunHee;Lim, Young Kyung;Chung, Weon Kyu;Huh, Hyun Do;Kim, Dong Wook;Yoon, Myonggeun
    • Progress in Medical Physics
    • /
    • v.27 no.4
    • /
    • pp.213-219
    • /
    • 2016
  • The position verification of the radiation source utilized in brachytherapy forms a critical factor in determining the therapeutic efficiency. Currently, films are used to verify the source position; however, this method is encumbered by the lengthy time interval required from film scanning to analysis, which makes real-time position verification difficult. In general, the source position accuracy is usually tested in a monthly quality assurance check. In this context, this study investigates the feasibility of the real-time position verification of the radiation source in high dose rate (HDR) brachytherapy with the use of scintillating fibers. To this end, we construct a system consisting of scintillating fibers and a silicon photomultiplier (SiPM), optimize the dosimetric software setup and radiation system characteristics to obtain maximum measurement accuracy, and determine the relative ratio of the measured signals dependent upon the position of the scintillating fiber. According to the dosimetric results based on a treatment plan, in which the dwell time is set at 30 and 60 s at two dwell positions, the number of signals is 31.5 and 83, respectively. In other words, the signal rate roughly doubles in proportion to the dwell time. The source position can also be confirmed at the same time. With further improvements in the spatial resolution and scintillating fiber array, the source position can be verified in real-time in clinical settings with the use of a scintillating fiber-based system.

Manufacturing of an FBG sensor imbedded small wind turbine blade (광섬유 격자센서 내장형 소형 풍력발전기 날개 제작)

  • Kim, Chang-Hwan;Yun, Jin-Young;Kim, Hyun-Gyu;Kim, Kwan-Soo;Paek, In-Su;Yoo, Neung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.32 no.4
    • /
    • pp.1-8
    • /
    • 2012
  • A Fiber Bragg Grating (FBG) sensor imbedded small wind turbine blade was manufactured to experimentally investigate the feasibility to embed FBG sensors between layers of glass fiber to monitor dynamic strains of the wind turbine blade. The blade which is similar to a commercial 300 W wind turbine blade was manufactured with glass fiber as a reinforcement and epoxy resin as base material. A total of five FBG sensors including one temperature sensor were imbedded in the blade to sense mechanical strain and temperature. While manufacturing the blade, residual strain and temperature that occurred in the small wind turbine blade were monitored using the imbedded FBG sensor array. To examine the sensor performance, an impact test was carried out. The experimental results from the FBG sensors were close to those from electrical strain gages mounted on the blade root surface. The mode shapes of the blade were analyzed also using a commercial Ansys simulation with a model obtained from a three dimensional laser scanning of the blade.

Multi-focal Microscopic System Using a Fiber Bundle (광섬유 다발을 이용한 다초점 현미경)

  • Gu, Young-Mo;Ham, Hyo-Shick;Choi, Sung-Eul
    • Korean Journal of Optics and Photonics
    • /
    • v.20 no.6
    • /
    • pp.354-360
    • /
    • 2009
  • We have constructed and analyzed the performance of a simple fiber bundle multi-focal microscope. The microscope had a fiber bundle substituted for micro-lens array that is the core part of MMM(multi-focal multi-photon microscope). The MMM is a type of confocal microscope. To analyze the performance and characteristics of the fiber bundle multi-focal microscope, three types of samples were used: a standard grating, USAF 1951(7, 3), and 1951(7, 6). Using two polarizers and a polarizing beam splitter, we eliminated noise and got clear images. We obtained the FWHM of fiber spot images with the standard grating using two different magnifier lenses which were 63X and 20X, and found an image of the sample as a distribution of fiber spot images. For this case we used the low magnification lens, which gives denser distribution, so that we could get clearer images. In order to test the resolution of the fiber bundle multi-focal microscopic system, we used the USAF 1951 sample which has a smaller line interval than that of the standard grating. The FWHM of the line width of the image coincides well with the real line width of the USAF 1951 sample. We confirmed the performance of a fiber bundle multi-focal microscopic system which is relatively simple but has submicron resolution and is able to get 1600 images at the same time.