• Title/Summary/Keyword: Fiber Reinforced

Search Result 4,422, Processing Time 0.026 seconds

Bending performance and calculation of reinforced beam with hybrid fiber and CaCO3 whisker

  • Li Li;Yapeng Qin;Mingli Cao;Junfeng Guan;Chaopeng Xie
    • Computers and Concrete
    • /
    • v.31 no.3
    • /
    • pp.197-206
    • /
    • 2023
  • In this paper, the bending performance of a MSFRHPC (containing steel fiber, polyvinyl alcohol (PVA) fiber, and CW)-reinforced beam was studied for the first time. Introducing a multiscale fiber system increased the first crack load (up to 150%), yield load (up to 50%), and peak load (up to 15%) of reinforced beams. The multiscale fiber system delays cracking of the reinforced beam, reduces crack width of the reinforced beam in normal use, and improves the durability of the beam. Considering yield load and peak load, the reinforcing effect of multiscale fiber on the high-reinforcement ratio beam (1.00%) is better than that on the low-reinforcement ratio beam (0.57%). Introducing fibers slowed the development of cracks in the reinforced beam under bending. With the added hybrid fiber, the deformation concentration of reinforced beams after yield was more significant with concentration in 1 or 2 cracks. A model for predicting the flexural capacity of MSFRHPC-reinforced beams was proposed, considering the action of multiscale hybrid fibers. This research is helpful for structure application of MSFRHPC-containing CW.

Fracture Toughness of Glass Fiber Reinforced Laminated Timbers (유리섬유 보강적층재의 파괴인성 특성)

  • Kim, Keon-ho;Hong, Soon-Il
    • Journal of the Korean Wood Science and Technology
    • /
    • v.43 no.6
    • /
    • pp.861-867
    • /
    • 2015
  • The Compact Tension (CT) type test was performed in order to evaluate the fracture toughness performance of glass fiber-reinforced laminated timber. Glass fiber textile and sheet Glass fiber reinforced plastic were used as reinforcement. The reinforced laminated timber was formed by inserting and laminating the reinforcement between laminated woods. Compact tension samples are produced under ASTM D5045. The sample length was determined by taking account of the end distance of 7D, and bolt holes (12 mm, 16 mm, 20 mm) had been made at the end of artificial notches in advance. The fracture toughness load of sheet fiberglass reinforced plastic reinforced laminated timber was increased 33 % in comparison to unreinforced laminated timber while the glass fiber textile reinforced laminated timber was increased 152 %. According to Double Cantilever Beam theory, the stress intensity factor was 1.08~1.38 for sheet glass fiber reinforced plastic reinforced laminated timber and 1.38~1.86 for glass fiber textile reinforced laminated timber, respectively. That was because, for the glass fiber textile reinforced laminated timber, the fiber array direction of glass fiber and laminated wood orthogonal to each other suppressed the split propagation in the wood.

Evaluation of Electromagnetic Pulse Shielding Performance of Amorphous Metallic Fiber Reinforced Cement Composite (비정질 강섬유 보강 시멘트 복합체의 전자파 차폐성능 평가)

  • Lee, Sang-Kyu;Kim, Gyu-Yong;Hwang, Eui-Chul;Son, Min-Jae;Baek, Jae-Wook;Nam, Jeong-Soo
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2018.05a
    • /
    • pp.50-51
    • /
    • 2018
  • In this study, it evaluate the electromagnetic pulse shielding performance of amorphous metallic fiber reinforced cement composite with other steel fiber reinforced cement composite. Hooked-ended steel fiber, smooth steel fiber and amorphous metallic fiber were reinforced 2.0 vol.% in cement composites respectively. The electromagnetic pulse shielding performance was evaluated by MIL-STD-188-125-1. As a result, shielding performance of amorphous metallic fiber reinforced cement composite was higher than Hooked-ended and smooth steel fiber reinforced cement composites. In addition, the relationship between the electrical conductivity and the electromagnetic pulse shielding performance of the cement composite was confirmed.

  • PDF

Mechanical properties of natural fiber-reinforced normal strength and high-fluidity concretes

  • Kim, Joo-Seok;Lee, Hyoung-Ju;Choi, Yeol
    • Computers and Concrete
    • /
    • v.11 no.6
    • /
    • pp.531-539
    • /
    • 2013
  • An experimental investigation of mechanical properties of jute fiber-reinforced concrete (JFRC) has been reported for making a suitable construction material in terms of fiber reinforcement. Two jute fiber reinforced concretes, called jute fiber reinforced normal strength concrete (JFRNSC) and jute fiber-reinforced high-fluidity concrete (JFRHFC), were tested in compression, flexure and splitting tension. Compressive, flexural and splitting tensile strengths of specimens were investigated to four levels of jute fiber contents by volume fraction. From the test results, Jute fiber can be successfully used for normal strength concrete (NSC) and high-fluidity concrete (HFC). Particularly, HFC with jute fibers shows relatively higher improvement of strength property than that of normal strength concrete.

Slump and Mechanical Properties of Hybrid Steel-PVA Fiber Reinforced Concrete (강섬유와 PVA 섬유로 하이브리드 보강된 콘크리트의 슬럼프 및 역학적 특성)

  • Yang, Keun-Hyeok
    • Journal of the Korea Concrete Institute
    • /
    • v.22 no.5
    • /
    • pp.651-658
    • /
    • 2010
  • Sixteen concrete mixes reinforced with hybrid steel-polybinyl alcohol (PVA) fibers and a control concrete mix with no fiber were tested in order to examine the effect of the micro and macro fibers on the slump and different mechanical properties of concrete. Main variables investigated were length and volume fraction of steel and PVA fibers. The measured mechanical properties of hybrid fiber reinforced concrete were analyzed using the fiber reinforcing index and compared with those recorded from monolithic steel or PVA fiber reinforced concrete. The initial slump of hybrid fiber reinforced concrete decreased with the increase of the aspect ratio and the volume fraction of fibers. In addition, splitting tensile strength, modui of rupture and elasticity, and flexural toughness index of concrete increased with the increase of the fiber reinforcement index. Modulus of rupture and flexural toughness index of hybrid fiber reinforced concrete were higher than those of monolithic fiber reinforced concrete, though the total volume fraction of hybrid fibers was lower than that of monolithic fiber. For enhancing the flexural toughness index of hybrid fiber reinforced concrete, using the steel fiber of 60 mm length was more effective than using the steel fibers combined with 60 mm and 30 mm lengths.

Implant Restorations Using Fiber Reinforced Framework (Fiber Reinforced Framework를 이용한 Implant 수복증례)

  • Song, Ho-Yong;Lee, Yang-Jin;Jo, Ri-Ra
    • Journal of the Korean Academy of Esthetic Dentistry
    • /
    • v.10 no.2
    • /
    • pp.21-30
    • /
    • 2001
  • Fiber reinforced materials have favorable mechanical properties. Moreover, the strength to weight ratios of this material is superior to those of most alloys. Comparing to the metals, it showed many other advantages as well, including non-corrosiveness, translucency and easy repair characteristic. Since, it has the potential for the chair-side and laboratory fabrication, it is not surprising that fiber reinforced composites offer the potential for use in various applications in dentistry. To make the well-fitted restorations, Fiber reinforced composite (FRC) has been suggested as an alternative framework material for the implant supported fixed prosthesis. Two fixed partial denture fabrication procedures were tried. Vectris fiber was pressed to the EsthetiCone gold cylinder on the implant positioned cast. And then, Targis were added on it. In the other method, we used the customized component using UCLA abutment. The beads for retaining the Vectris fiber were added on the abutment. If careful laboratory and clinical techniques were done, these two techniques would fulfill the demands of the esthetics and strength.

  • PDF

A development of modification program for steel fiber reinforced shotcrete during design and construction stages (강섬유 숏크리트의 설계 및 시공에 대한 문제점 및 개선방향에 대한 연구)

  • Kim, Sang-Hwan;Youn, Seung-Ki
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2009.03a
    • /
    • pp.48-57
    • /
    • 2009
  • The quality control of tunnel support construction is very important to maintain a long term stability of tunnel. Especially, steel fiber reinforced shotcrete should be necessary to investigate practically the condition of quality control in the construction site. In order to perform this study, the design criteria and specifications relevant to steel fiber reinforced shotcrete are reviewed. And the comparison is made between the bearing capacity of the several shotcrete layers, based on the equivalence of the bending moments. Eight tunnel construction sites are also investigated carefully to examine and analyse the characteristics of steel fiber reinforced shotcrete especially including strength and mixing condition of steel fiber. Based on the results, it is founded the items to be improved in the future. In addition, the modification program for the specifications of steel fiber reinforced shotcrete is suggested.

  • PDF

Interaction of magnetic water and polypropylene fiber on fresh and hardened properties of concrete

  • Ansari, Mokhtar;Safiey, Amir
    • Steel and Composite Structures
    • /
    • v.39 no.3
    • /
    • pp.307-318
    • /
    • 2021
  • Utilizing fibers is an effective way to avoid the brittle behavior of the conventional concrete and can enhance its ductility. In particular, propylene fibers can improve concrete properties, including energy absorption, physical and mechanical properties, controlling shrinkage cracks. The increase of fiber density leads to an increase of the overlapping surface of the fiber of concrete and, in turn, a decrease of cracks developed in the concrete. However, the workability of fiber reinforced concrete tends to be lower than the conventional concrete owing mainly to the hairline thickness and excessive concentration of fibers. The low slump of concrete impedes the construction of reinforced concrete members. In this research, we study if the utilization of magnetic water can alleviate the workability issue of young fiber reinforced concrete. To this end, the compressive and flexural strength of four types of concrete (conventional concrete, fiber reinforced concrete, magnetic concrete, magnetic fiber-reinforced concrete) is studied and compared at three different ages of 7, 14, and 28 days. In order to study the influence of the fiber density and length, a study on specimens with three different fiber density (1, 2, 5 kg of fiber in each cubic meter of concrete) and fiber length (6, 12, 18 mm) is undertaken. The result shows the magnetic fiber concrete can result in an increase of the flexural and compressive strength of concrete at higher ages.

An Experimental Study on the Compressive Strength Characteristics of Reinforced Concrete Columns Strengthened with Fiber Sheets (섬유시트로 보강된 철근콘크리트 기둥의 압축강도 특성에 관한 실험적 연구)

  • Kim, Jeong-Sup;Choi, Jin-Seok;Cho, Cheol-Hee;Go, Song-Kyoon
    • Journal of the Korea Institute of Building Construction
    • /
    • v.3 no.2
    • /
    • pp.119-127
    • /
    • 2003
  • Test specimen test was performed using concrete reinforced with fiber sheet and the test variables were based on the kinds of fiber and the number of reinforcement layers. Using steel-concrete reinforced with fiber sheet, compression tests were performed and the test variables were the kinds of fiber, number reinforcement layers and reinforcement layer order. The following results were obtained: 1) It was demonstrated that compressive strength of the test specimen reinforced during test specimen test and member test increased as the number of reinforcement layers increased. 2) It was shown that non-reinforced test, specimen were destroyed during the member tests, but the specimen reinforced with CFS destroyed and the GFS-reinforced specimen and composite reinforced specimen showed ductile destruction. 3) As a result of tests on kinds of reinforcement fiber, it was demonstrated that CFS-reinforced test specimen had higher compressive strength in a 공시체 test. In the member test, 2ply-and 3ply-GFS reinforced specimens except lplied one had higher compressive strength. It was because partial destruction occurred due to the rate of height/section. 4) For layer strength order, compared with test specimen reinforced only with a single reinforced material, test specimen reinforced with CFS and GFS, and test specimen reinforced with CFS first showed better results in compressive strength and ductility judgement.

The Fracture Toughness and Crack Propagation behavoir of Short-fiber Reinforced Ruber (단섬유 강화고무의 파괴인성 및 크랙진전 거동)

  • Ryu, Sang-Ryeoul;Lee, Dong-Joo
    • Proceedings of the KSME Conference
    • /
    • 2000.04a
    • /
    • pp.85-90
    • /
    • 2000
  • The fracture toughness and crack propagation behaviors of short nylon66 fiber reinforced Chloroprene rubber nave been Investigated as functions of fiber aspect ratio, fiber content and interphase conditions. The J for crack initiation and rupture were determined for short-fiber reinforced rubber. The values of $J_c$ for most reinforced rubbers were low compared that of matrix. But, $J_r$ at rupture showed a higher value than that of matrix. The crack propagation behaviors were analyzed into 3 patterns with increasing fiber aspect ratio and fiber content. The tearing mechanisms of matrix and fiber reinforced rubber were observed by CCD camera focused on the tip of crack and load-displacement graph. Both cases showed a completely different behaviors

  • PDF