• Title/Summary/Keyword: Fiber Laser Encoder System

Search Result 4, Processing Time 0.022 seconds

Fiber Laser based Fiber Bragg Grating Strain Sensor (광섬유 레이저를 이용한 광섬유격자 스트레인 센서)

  • Kim, Jong-Seop;Park, Hyoung-Jun;Song, Min-Ho
    • Proceedings of the KIEE Conference
    • /
    • 2002.07c
    • /
    • pp.1936-1938
    • /
    • 2002
  • A tunable fiber laser and the Quadrature Sampling technique are used to construct highly sensitive fiber-optic distributive Bragg grating strain sensor system. By using a wavelength-modulated fiber laser, the variations of strain-dependent Bragg wavelengths are transformed into the variations of time-domain reflection profiles. The locations of profile peaks that correspond to the applied strains are demodulated using a precise wavelength encoder that uses a fiber-optic Mach-Zehnder interferometer and Quadrature Sampling technique. With the extremely high sensitive optical encoder, we could obtain not only high sensitivity, but also very linear responses that was impossible with the conventional techniques. This paper is attempted to report the theoretical and experimental results.

  • PDF

An Experimental Study on the Tappet Spin for a Direct Acting Valve Train System (직접 구동형 밸브 트레인 시스템의 태핏 회전에 관한 실험적 연구)

  • Cho, Myung-Rae;Kim, Hyung-Jun;Moon, Tae-Seon;Han, Dong-Chul
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.7
    • /
    • pp.1179-1184
    • /
    • 2003
  • The technique for measuring the rotational speed of tappet in direct acting type valve train system has been developed. The optic signal monitoring system with laser and optic fiber was designed to follow the signal of tappet rotation. The system was based on ON/OFF signal generation from the additional encoder teeth under the tappet with optic fibers attached photo transistor. The data showed that tappet rotation was affected by offset, oil temperature and cam shaft operating speed. Also it was found that tappet rotation increases with oil temperature. Tappet spin was delayed 10∼s20$^{\circ}$ cam angle after valve opening. The instantaneous rotational speed of tappet was reciprocal to cam shaft speed and the tappet and the cam angle ratio was located in the range of 0.1∼0.3.

Development of Measurement System for Tappet Rotation in the Valve Train System (밸브 트레인 시스템의 태핏 회전 측정 장치의 개발)

  • 김형준;조명래;신흥주;한동철
    • Tribology and Lubricants
    • /
    • v.14 no.3
    • /
    • pp.81-86
    • /
    • 1998
  • The purpose of this paper is to measure the rotational speed of tappet in OHC valve train system. Tappet has eccentricity about cam center, which induces the tappet rotation and prevents from wear. In this paper, the experimental test rig which composes of one cam system is developed to measure the tappet rotation by using the laser generating system, rotary encoder, optical fiber, and photo transistor. The direction of tappet rotation is judged from the oder of optical signal. As results of experiment, average and instant rotational speed and average rotation angle per one cam revolution are presented. Measured results show that eccentricity ratio is dominant factor for the tappet rotation, and tappet is rotated at the base circle.