• Title/Summary/Keyword: Fiber Coil

Search Result 58, Processing Time 0.021 seconds

OPGW Corrosion Detection Using Nondestructive Test Method

  • Jeong, Jae-Kee;Yoon, Gi-Gab;Kang, Ji-Won;Yang, Hai-Won
    • Journal of Electrical Engineering and information Science
    • /
    • v.3 no.1
    • /
    • pp.45-50
    • /
    • 1998
  • This paper deals with some characteristics of a nondestructive eddy current detector to measure OPGW(Composite overhead ground wire with optical fiber) corrosion. This detector is designed to automatically run on OPGW and to continuously inspect the corrosion of the line. The impedance of the eddy current coil changing by any corrosion phenomenon of OPGW is analyzed. Several performances of the detector are described and experimental procedures and test results are also given. As a result, it is shown that the implemented detector can be measured some quantitative data for crack, broken wires or severe deteriorations in OPGW. This nondestructive test method would be applied to improve the reliability and efficiency of transmission line in service.

  • PDF

Characteristics of AFPM motor in variation of winding shape (AFPM 전동기의 권선 형상에 따른 특성)

  • Kim, Hyoung-Gil;Seo, Young-Taek;Kong, Jeong-Sik;Oh, Chul-Soo
    • Proceedings of the KIEE Conference
    • /
    • 2000.07b
    • /
    • pp.735-737
    • /
    • 2000
  • An axial-flux permanent-magnet machine(AFPM) topology with coreless winding is proposed. In the proposed AFPM configuration. the winding consists of a hexagon-shaped coils encapsulated in fiber-reinforced epoxy resin. Due to the lack of the iron core. the overall machine structure has high compactness and lightness. The simplified design calculation of the back emf was obtained. In this study, motor design was carried out using the software package Maxwell. This paper discusses the basic design of coil winding of AFPM motor. Experimental results were taken form a prototype machine rated 0.4 Nm, 2000 rpm.

  • PDF

The study on X-ray generation in the Coaxial Plasma focus Device (동축 플라즈마 집속장치에서의 x-선 방출에 관한 연구)

  • 엄영현
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1989.02a
    • /
    • pp.65-69
    • /
    • 1989
  • Mather type dense plasma focus device was develooped for the feasibili쇼 study in its application to the x-ray lithography. To etermine the electrical characteristics,the temporal begavior of the discharge current and the voltage was measured by using the Rogowski coil and the high voltage probe respectively. The results are 9 $\mu\textrm{s}$ of the period, 18m$\Omega$ of resistance and 0.16$\mu$Η of inductance. The average current sheath velocity was measured by the light signal emitted at the moving plasma sheath. The light signal was detected through two fiber bundles. When the applied voltage was 13 kV and the initial jpressure of argon was 21.8 Pa, the best plasma focus was occurred. The x-ray emission characteristics from the plasma focus was determined by the x-ray pictures taken by pinhole camera. It is focus that the plasma was focused at 1.4 cm distant position above the center electrode and its diameter was about 1.0 m.

  • PDF

Analysis and Design of Planar Textile Resonator for Wearable Magnetic Resonance-Wireless Power Transfer (의복용 자기공진형 무선전력전송 시스템을 위한 평면형 직물공진기의 설계 및 연구)

  • Kang, Seok Hyon;Jung, Chang Won
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.53 no.8
    • /
    • pp.119-126
    • /
    • 2016
  • In this paper, we proposed the planar textile resonator for constructing wearable MR-WPT system and analyzed the characteristic of textile substrates used in resonators. The planar textile resonators were designed to resonate at 1-10 MHz. The loop and coil were fabricated planar structure on textile substrate using conductive materials. Polyester fiber and cotton widely used in real life were chosen as textile resonators for wearable applications and copper tape and silver paste were used for fabricating planar loop and coil on textile substrate. For comparison analysis on transfer efficiency according to the types of textile, transmitter and receiver parts were symmetric. According to the result, for the highest transfer efficiency of wearable WPT system, the planar resonators have specifications of relative thick textile substrate with low permittivity and low surface resistance of conductive pattern. The performed experiments show that the planar textile resonator is possible to be used for resonator in wearable MR-WPT system.

Nondestructive evaluation of wall thinning covered with insulation using pulsed eddy current (펄스와전류를 이용한 보온재 비해체식 배관감육 평가기술)

  • Park, Duck-Gun;Babu, M.K.;Lee, Duk-Hyun
    • Transactions of the Korean Society of Pressure Vessels and Piping
    • /
    • v.10 no.1
    • /
    • pp.90-95
    • /
    • 2014
  • Local wall thinning is a point of concern in almost all steel structures such as pipe lines covered with a thermal insulator made up of materials with low thermal conductivity(fiberglass or mineral wool); hence, Non Destructive Technique(NDT) methods that are capable of detecting the wall thinning and defects without removing the insulation are necessary. In this study we developed a Pulsed Eddy Current(PEC) system to detect the wall thinning of Ferro magnetic steel pipes covered with fiber glass thermal insulator and shielded with Aluminum plate. The developed system is capable of detecting the wall thickness change through an insulation of thickness 10cm and 0.4mm aluminum shielding. In order to confirm the thickness change due to wall thinning, two different sensors, a hall sensor and coil sensor were used as a detecting element. In both cases, the results show a very good change corresponding to the thickness change of the test specimen. During these experiments a carbon steel tube of diameter 210mm and a length of 620mm, which is covered with insulator of 95mm thickness was used. To simulate the wall thinning, the thickness of the tube is changed for a specified length such as 2.5mm, 5mm and 8 mm from the inner surface of the tube. A 0.4mm thick Aluminum plate was covered on the Test specimen to simulate the shielding of the insulated pipelines. For both hall sensor and coil detection methods Fast Fourier transform(FFT) was calculated using window approach and the results for the test specimen without Aluminum shielding were summarized which shows a clear identification of thickness change in the test specimen by comparing the magnitude spectra. The PEC system can detect the wall thinning under the 95 mm thickness insulation and 0.4 mm Al shielding, and the output signal showed linear relation with tube wall thickness.

Optical Current Sensors Based on Polarization Rotated Reflection Interferometry (편광회전 반사간섭계를 이용한 광전류센서)

  • Jang, Ji-Hyang;Chu, Woo-Sung;Kim, Hoon;Seo, Jun-Kyu;Kim, Kyung-Jo;Kim, Jun-Whee;Oh, Min-Cheol
    • Korean Journal of Optics and Photonics
    • /
    • v.21 no.4
    • /
    • pp.168-174
    • /
    • 2010
  • Fiber optic current sensors based on polarization-rotated reflection interferometry are demonstrated by incorporating them into polymeric optical waveguide components, including polarization-maintaining 3-dB couplers, TE-pass waveguide polarizers, and thermooptic phase modulators. To remove the bending induced birefringence, optical fiber coil is annealed at $850^{\circ}C$ for 24 hours. The reflection interferometry comprising polymer waveguide devices exhibit a highly stable output signal corresponding to the flowing current.

Development of Highly Reliable Power and Communication System for Essential Instruments Under Severe Accidents in NPP

  • Choi, Bo Hwan;Jang, Gi Chan;Shin, Sung Min;Lee, Soo Ill;Kang, Hyun Gook;Rim, Chun Taek
    • Nuclear Engineering and Technology
    • /
    • v.48 no.5
    • /
    • pp.1206-1218
    • /
    • 2016
  • This article proposes a highly reliable power and communication system that guarantees the protection of essential instruments in a nuclear power plant under a severe accident. Both power and communication lines are established with not only conventional wired channels, but also the proposed wireless channels for emergency reserve. An inductive power transfer system is selected due to its robust power transfer characteristics under high temperature, high pressure, and highly humid environments with a large amount of scattered debris after a severe accident. A thermal insulation box and a glass-fiber reinforced plastic box are proposed to protect the essential instruments, including vulnerable electronic circuits, from extremely high temperatures of up to $627^{\circ}C$ and pressure of up to 5 bar. The proposed wireless power and communication system is experimentally verified by an inductive power transfer system prototype having a dipole coil structure and prototype Zigbee modules over a 7-m distance, where both the thermal insulation box and the glass-fiber reinforced plastic box are fabricated and tested using a high-temperature chamber. Moreover, an experiment on the effects of a high radiation environment on various electronic devices is conducted based on the radiation test having a maximum accumulated dose of 27 Mrad.

A HISTOLOGIC STUDY OF PULPAL REACTION AFTER EXPERIMENTAL TOOTH MOVEMENT IN RATS (백서구치의 실험적 치아이동후 치수조직 변화에 관한 조직학적 연구)

  • Jin, Keun Ho;Hong, Sung Joon
    • The korean journal of orthodontics
    • /
    • v.21 no.3
    • /
    • pp.635-656
    • /
    • 1991
  • It was the aim of this investigation to evaluate some histologic aspect of rat pulp tissue after it had been compromised by an experimental orthodontic force. Experimental animals of thirty five Spraque-Dawley rats were employed. The first upper molars had been successively mesial moved (initial load 100 gr.) with a closed coil spring during 21 days. The experimental periods were set on immediate, 1 day, 1 week, 2 weeks, 3 weeks, 4 weeks following retention time. On each experimental period, the rats were killed and prepared for the light microscopy. After prepared with H/E stain and Gomori's one-step trichrome stain, the specimens were analyzed with evaluation criteria which were adopted in this study. The result may be summarized as follows; 1. The main pulp changes due to experimental orthodontic force included vacuolization of odontoblastic layer, circulation disturbance, root resorption, reduced pulp collagenous fiber density and mean cell count of pulp fibroblast in the immediate group. 2. The pulp tissue changes were revealed reversible because the relieved pulp tissues from experimental orthodontic force were recovered rapidly in each evaluation criteria during retention periods. 3. Compared with normal control group, pulp collagenous fiber density were decreased in immediated group (p < 0.01), but increased in each retention groups. These seem to suggest that the pulp tissues were aged after experimental orthodontic force conditions. 4. Compared with normal control group, mean cell counts of pulp fibroblasts were decreased in immediate group (p < 0.05), but increased continuous in each retention groups. These seem to indicate that the pulp tissues were highly regenerative after experimental orthodontic force conditions. 5. Compared with normal control group, root resorptions occurred in all immediate specimens (p < 0.01) and they were healed in each retention periods, but often observed in 4 weeks retention group. These seem to indicate that root resorptions were recovered slowly after experimental orthodontic force conditions.

  • PDF

Screening for candidate genes related with histological microstructure, meat quality and carcass characteristic in pig based on RNA-seq data

  • Ropka-Molik, Katarzyna;Bereta, Anna;Zukowski, Kacper;Tyra, Miroslaw;Piorkowska, Katarzyna;Zak, Grzegorz;Oczkowicz, Maria
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.31 no.10
    • /
    • pp.1565-1574
    • /
    • 2018
  • Objective: The aim of the present study was to identify genetic variants based on RNA-seq data, obtained via transcriptome sequencing of muscle tissue of pigs differing in muscle histological structure, and to verify the variants' effect on histological microstructure and production traits in a larger pig population. Methods: RNA-seq data was used to identify the panel of single nucleotide polymorphisms (SNPs) significantly related with percentage and diameter of each fiber type (I, IIA, IIB). Detected polymorphisms were mapped to quantitative trait loci (QTLs) regions. Next, the association study was performed on 944 animals representing five breeds (Landrace, Large White, Pietrain, Duroc, and native Puławska breed) in order to evaluate the relationship of selected SNPs and histological characteristics, meat quality and carcasses traits. Results: Mapping of detected genetic variants to QTL regions showed that chromosome 14 was the most overrepresented with the identification of four QTLs related to percentage of fiber types I and IIA. The association study performed on a 293 longissimus muscle samples confirmed a significant positive effect of transforming acidic coiled-coil-containing protein 2 (TACC2) polymorphisms on fiber diameter, while SNP within forkhead box O1 (FOXO1) locus was associated with decrease of diameter of fiber types IIA and IIB. Moreover, subsequent general linear model analysis showed significant relationship of FOXO1, delta 4-desaturase, sphingolipid 1 (DEGS1), and troponin T2 (TNNT2) genes with loin 'eye' area, FOXO1 with loin weight, as well as FOXO1 and TACC2 with lean meat percentage. Furthermore, the intramuscular fat content was positively associated (p<0.01) with occurrence of polymorphisms within DEGS1, TNNT2 genes and negatively with occurrence of TACC2 polymorphism. Conclusion: This study's results indicate that the SNP calling analysis based on RNA-seq data can be used to search candidate genes and establish the genetic basis of phenotypic traits. The presented results can be used for future studies evaluating the use of selected SNPs as genetic markers related to muscle histological profile and production traits in pig breeding.

Insulation of Winding and Current Lead of the High-Tc Superconducting Magnets for DC Reactor Type SFCL (DC 리액터형 고온초전도한류기용 고온초전도자석의 권선 및 전류리드의 절연)

  • 양성은;배덕권;전우용;김영식;김상현;고태국
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.226-229
    • /
    • 2003
  • Following the successful development of practical high temperature superconducting (HTS) wires, there has been renewed activity in the development of superconducting power equipments. HTS equipments must be operated in the coolant, such as liquid nitrogen (L$N_2$) or cooled by cooler, such as GM-cryocooler to maintain the temperature below critical temperature. In this paper, dielectric strength of some insulating materials, such as epoxy, teflon, and glass fiber reinforced plastic (GFRP) in L$N_2$was measured. Surface breakdown voltage of GFRP which is basic property in design of HTS solenoid coil was measured. Epoxy is a goof insulating material but it is fragile at cryogenic temperature. The multi-layer insulating method of current lead is suggested to compensate this fragile property. It consists of teflon tape layer and epoxy layer fixed with texture. Based on these measurements, the 6.6㎸ class HTS magnet for DC reactor type high-T$_{c}$ superconducting fault current limiter (SFCL) was successfully fabricated and tested.d.

  • PDF