• Title/Summary/Keyword: Fetal heart

Search Result 86, Processing Time 0.038 seconds

Effect of Postpartum Outcomes in Mother's Upright Position During the Second Stage of Labor: Systematic Review (분만 2기 산모의 직립자세가 분만결과에 미치는 효과: 체계적 문헌고찰)

  • Park, Seong-Hi;Hwang, Jeong-Hae;Choi, Yun-Kyoung;Kang, Chang-Bum
    • Women's Health Nursing
    • /
    • v.18 no.3
    • /
    • pp.209-222
    • /
    • 2012
  • Purpose: The purpose of this study was to determine whether upright position is effective in labor through systematic review in randomized controlled trials. Methods: We established the PICO (Patient-Intervention-Comparator-Outcome) strategy, and reviewed 282 literatures from national and international electronic databases, and finally selected 9 references based on inclusion and exclusion criteria. We evaluated the quality of references and carried out a meta-analysis. Results: The maternal outcomes showed that the duration of their second-stage labor was 2.29 minutes shorter than that of the women in the recumbent position, and were less likely to have episiotomy. The other outcomes, including the mode of delivery, blood loss, hemoglobin level, use of oxytocin, use of analgesics, and perineal laceration, did not differ between the groups. The fetal heart rate abnormality occurred less than in the control group. The Apgar scores of the groups did not differ. Conclusion: There is evidence that an upright position in the second stage of labor reduces the duration of the second stage of labor, the incidence of episiotomy, and an abnormal fetal heart rate.

A Study on MCG Imaging (MCG 영상진단 검사에 관한 연구)

  • Kim, Jong-Gyu
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.38 no.2
    • /
    • pp.135-140
    • /
    • 2006
  • Magnetocardiography (MCG) is the measurement and analysis of the magnetic component of the electro-magnetic field of the human heart, usually conducted externally, using extremely sensitive devices such as a Superconducting Quantum Interference Device (SQUID). MCG is a totally noninvasive method, it uses neither radiation nor ultrasonics. The magnetic activity of the heart is registered from outside the thorax. MCG has a very high sensitivity and a high spatial resolution for very a small, local myocardial current. In comparison to the electrical signals measured by an ECG, the magnetic signal does not disturb the boundaries of tissues with different electrical properties. MCG measures the myocardial function rather than describing the morphology. MCG is a relatively new technique that promises good spatial resolution and extremely high temporal resolution, thus complementing other heart activity measurement techniques such as Electrocardiography (ECG). The clinical uses of MCG are in detecting various cardiac disorders including myocardial infarction, ventricular hypertrophy, ventricular conduction defects, Wolff-Parkinson-White (WPW) syndrome, sudden cardiac death and fetal magnetocardiography. Magnetocardiography may be used alone or together with electrcardiography for the measurement of spontaneous or overloaded activity and for research or clinical purposes.

  • PDF

Automated Analysis of fetal Myocardial Performance Index of Doppler Waveform in Normal Pregnancy (정상 태아의 임신 분기별 좌심실 도플러 신호 자동 분석)

  • Kim, Su-min;Ye, Soo-young
    • Journal of the Korean Society of Radiology
    • /
    • v.14 no.6
    • /
    • pp.791-800
    • /
    • 2020
  • Ultrasonography is widely used to evaluate the function of fetal heart, but due to the subjective nature of the test, there are differences in measurement methods for each examiner, and especially the myocardial performance index has no reference index to date. Therefore, in this study, we wanted to analyze pulse Doppler waveforms of normal fetuses and develop an automatic measurement program to make objective measurements. One hundred and thirty-three pregnant women who visited the hospital for prenatal examinations were studied, myocardial performance index was measured after acquiring a pulse doppler image of the left ventricle. As a result, the early, mid and late pregnancy myocardial performance index, measured by the automatic measurement program conducted in this study, was found to increase as pregnancy continued.

Evaluation of maternal toxicity in rats exposed to the insecticide amitraz during pregnancy (임신 중 살충제 amitraz에 노출된 랫드의 모독성 평가)

  • Shin, Jin-Young;Oh, Ki-Suk;Shin, Dong-Ho;Kim, Sung-Ho;Kim, Hyoung-Chin;Park, Seung-Chun;Lee, Hyun-Sook;Chung, Moon-Koo;Kim, Jong-Choon
    • Korean Journal of Veterinary Research
    • /
    • v.44 no.4
    • /
    • pp.523-532
    • /
    • 2004
  • The present study was carried out to investigate the potential adverse effects of amitraz on pregnant dams after maternal exposure during the gestational days (GD) 1 through 19 in Sprague-Dawley rats. The test chemical was administered orally to pregnant rats at dose levels of 0, 3, 10, or 30 mg/kg/ day. During the test period, clinical signs, mortality, body weights, food consumption, serum biochemistry, gross findings, organ weights and reproductive findings on GD 20 were examined. In the 30 mg/kg group, an increase in the incidence of abnormal clinical signs and death, a suppression in the body weight gain, and a decrease in the food consumption were observed. A decrease in the liver weight and increases in the kidneys, adrenal glands and heart weights were also found. Serum biochemical investigations revealed increases in the aspartate aminotransferase (AST), total bilirubin, and chloride. In addition, an increase in the fetal death and decreases in the litter size and fetal body weight were seen at caesarean section. Inthe 10 mg/kg group, an increase in the incidence of abnormal clinical signs, decreases in the food consumption and liver weight, increases in the total bilirubin and chloride, and a decrease in the fetal body weight were observed. There were no adverse effects on clinical signs, mortality, body weights, food consumption, serum biochemistry, gross findings, organ weights and reproductive findings in the 3 mg/kg group. Based on the results, it was concluded that the 19-day repeated oral dose of amitraz to pregnant rats caused increases in the clinical signs, kidneys, adrenal glands and heart weights, AST, total bilirubin and chloride and decreases in the body weight gain, food consumption and liver weight at the dose levels of above 10 mg/kg/day. Under the present experimental conditions, the no-observed-adverse-effect level (NOAEL) of amitraz was considered to be 3 mg/kg/day.

THE CURRENT STATUS OF BIOMEDICAL ENGINEERING IN THE USA

  • Webster, John G.
    • Proceedings of the KOSOMBE Conference
    • /
    • v.1992 no.05
    • /
    • pp.27-47
    • /
    • 1992
  • Engineers have developed new instruments that aid in diagnosis and therapy Ultrasonic imaging has provided a nondamaging method of imaging internal organs. A complex transducer emits ultrasonic waves at many angles and reconstructs a map of internal anatomy and also velocities of blood in vessels. Fast computed tomography permits reconstruction of the 3-dimensional anatomy and perfusion of the heart at 20-Hz rates. Positron emission tomography uses certain isotopes that produce positrons that react with electrons to simultaneously emit two gamma rays in opposite directions. It locates the region of origin by using a ring of discrete scintillation detectors, each in electronic coincidence with an opposing detector. In magnetic resonance imaging, the patient is placed in a very strong magnetic field. The precessing of the hydrogen atoms is perturbed by an interrogating field to yield two-dimensional images of soft tissue having exceptional clarity. As an alternative to radiology image processing, film archiving, and retrieval, picture archiving and communication systems (PACS) are being implemented. Images from computed radiography, magnetic resonance imaging (MRI), nuclear medicine, and ultrasound are digitized, transmitted, and stored in computers for retrieval at distributed work stations. In electrical impedance tomography, electrodes are placed around the thorax. 50-kHz current is injected between two electrodes and voltages are measured on all other electrodes. A computer processes the data to yield an image of the resistivity of a 2-dimensional slice of the thorax. During fetal monitoring, a corkscrew electrode is screwed into the fetal scalp to measure the fetal electrocardiogram. Correlations with uterine contractions yield information on the status of the fetus during delivery To measure cardiac output by thermodilution, cold saline is injected into the right atrium. A thermistor in the right pulmonary artery yields temperature measurements, from which we can calculate cardiac output. In impedance cardiography, we measure the changes in electrical impedance as the heart ejects blood into the arteries. Motion artifacts are large, so signal averaging is useful during monitoring. An intraarterial blood gas monitoring system permits monitoring in real time. Light is sent down optical fibers inserted into the radial artery, where it is absorbed by dyes, which reemit the light at a different wavelength. The emitted light travels up optical fibers where an external instrument determines O2, CO2, and pH. Therapeutic devices include the electrosurgical unit. A high-frequency electric arc is drawn between the knife and the tissue. The arc cuts and the heat coagulates, thus preventing blood loss. Hyperthermia has demonstrated antitumor effects in patients in whom all conventional modes of therapy have failed. Methods of raising tumor temperature include focused ultrasound, radio-frequency power through needles, or microwaves. When the heart stops pumping, we use the defibrillator to restore normal pumping. A brief, high-current pulse through the heart synchronizes all cardiac fibers to restore normal rhythm. When the cardiac rhythm is too slow, we implant the cardiac pacemaker. An electrode within the heart stimulates the cardiac muscle to contract at the normal rate. When the cardiac valves are narrowed or leak, we implant an artificial valve. Silicone rubber and Teflon are used for biocompatibility. Artificial hearts powered by pneumatic hoses have been implanted in humans. However, the quality of life gradually degrades, and death ensues. When kidney stones develop, lithotripsy is used. A spark creates a pressure wave, which is focused on the stone and fragments it. The pieces pass out normally. When kidneys fail, the blood is cleansed during hemodialysis. Urea passes through a porous membrane to a dialysate bath to lower its concentration in the blood. The blind are able to read by scanning the Optacon with their fingertips. A camera scans letters and converts them to an array of vibrating pins. The deaf are able to hear using a cochlear implant. A microphone detects sound and divides it into frequency bands. 22 electrodes within the cochlea stimulate the acoustic the acoustic nerve to provide sound patterns. For those who have lost muscle function in the limbs, researchers are implanting electrodes to stimulate the muscle. Sensors in the legs and arms feed back signals to a computer that coordinates the stimulators to provide limb motion. For those with high spinal cord injury, a puff and sip switch can control a computer and permit the disabled person operate the computer and communicate with the outside world.

  • PDF

Factors Affecting Complete Fetal Loss Following Multifetal Pregnancy Reduction (다태임신 감수술 (Multifetal Pregnancy Reduction) 후 완전태아손실에 영향을 미치는 인자)

  • Kim, Hye-Ok;Kim, Mun-Young;Song, Hyun-Jeong;Park, Chan-Woo;Hur, Girl;Kim, Jin-Yeong;Yang, Kwang-Mun;You, Keun-Jae;Song, In-Ok;Jun, Jong-Young;Koong, Mi-Kyoung;Kang, Inn-Soo
    • Clinical and Experimental Reproductive Medicine
    • /
    • v.30 no.1
    • /
    • pp.39-45
    • /
    • 2003
  • Objective : To identify the factors affecting the complete fetal loss following multifetal pregnancy reduction (MFPR). Design: Retrospective clinical study. Methods : A total of 256 consecutive treatments of MFPR in IVF-ET cycles performed between 1992 through 2000 in Samsung Cheil hospital were analyzed. MFPR was done around 8 weeks of gestation by transvaginal ultrasono-guided aspiration in multiple pregnancies and reduced to singleton or twins. Stepwise logistic regression was performed to identify the factors affecting the final outcome of pregnancy after MFPR. Dependent variable was complete fetal loss and the independent variables were maternal age, paternal age, initial number of gestational sac (iGSNO), initial number of fetal heart beat, the number of remaining live fetus after MFPR, and chorionicity. Results: The total survival rate was 87.9%, and total fetal loss rate after MFPR was 12.1%. Total fetal loss occurred within four weeks from MFPR procedure was 1.95%. Total loss occurred after four weeks of procedure and before 24 gestational weeks was 8.2%. Seventy nine percent (202/256) of pregnancies delivered after 34 weeks of gestation. The survival rate of pregnancies reduced to singleton was significantly higher than that of pregnancies reduced to twins (93.5% vs. 86.7%, p<0.05). The mean ($\pm$SEM) gestational age at delivery was $36.2{\pm}1.0$ and $34.1{\pm}0.5$ weeks for pregnancies reduced to singletons and twins, respectively (p=0.065). Logistic regression analysis revealed that the maternal age, the number of initial gestational sac (iGSNO), and the number of remaining live fetus after MFPR significantly affected the rate of total fetal loss (Z = 0.174'age + 0.596'iGSNO + 1.324'remaining fetuses -12.07), (p<0.05). Conclusions: MFPR seems to be a relatively safe and efficient method to improve the obstetric outcome in high order multiple pregnancy. Because the maternal age, the number of initial gestational sac and the remaining live fetuses after MFPR affect the total fetal loss rate, restriction of the number of transferred embryos according to the age and MFPR to singleton fetus could be considered for the better obstetric outcome in IVF pregnancy.

Flow Cytometric Analysis of Endothelial Cell Viability in Arterial Allograft (동종동맥판 혈관내피세포의 생육성 평가에 관한 연구)

  • 임창영;홍은경
    • Journal of Chest Surgery
    • /
    • v.30 no.6
    • /
    • pp.553-558
    • /
    • 1997
  • Arterial allografts have known advantages over prosthetic vascular conduit for treatment of heart valvular disease, congenital heart disease and aortic disease. Cell viability may play a role in determining the longterm outcome of allografts. Endothelial cell is one important part in determining the allograft viability. To evaluate the viability of endothelial cells using current allograft preservation technique, porcine heart valve leaflets and arterial wall were subjected to collagenase digestion. Single endothelial cell suspension was labeled with GSA-PITC(Griffonia simplicifolia agglutininfluorescein isothiocyan te), a vascular, endothelial cell specific marker. The cell suspension was washed and incubated with Pl(Propidium iodide), which does not bind with viable cells, Endothelial cell viability was evaluated by calculating the percentage of GSA-FITC(+) and Pl(-) group using flowcytometric analysis. Allografts were treated with $4^{\circ}C$ antibiotic solo!ion for 24 hours for sterilization. After this, half of allografts were stored in $4^{\circ}C$ RPMI 1640 with HEPES buffer culture medium with 10% fetal bovine serum for 1 to 14 days(Group I). Another half of allografts were cryopreserved with a currently used technique (Group II). During the procurement and sterilization of arterial allografts, 22.8% and 24.4% of endothelial cell viability declined, respectively. In Group I, 11.9% of endothelial cell viability declined further steadily during 14 days of storage. In Group II, 13.7% of endothelial cell viability declined. These results show that largest loss of endothelial cell viability occurs during the nitial process. After 14 days of arterial allograft storage under $4^{\circ}C$ nutrient medium or cryopreservation, about 40% of endothelial cell viability is maintained. There were no differences between the endothelial cell viability from aortic valve leaflet, pulmonic valve leaflets, aortic wall and pulmonic wall.

  • PDF

Experimental Fetal Cardiopulmonary Bypass in the Fetal Lamb Model (태아양 모델을 이용한 실험적 태아 심폐우회술)

  • 이정렬;임홍국;김원곤;김종성;최정연;김용진
    • Journal of Chest Surgery
    • /
    • v.32 no.6
    • /
    • pp.495-503
    • /
    • 1999
  • Background: We tested the technical feasibility of fetal cardiac bypass and collected baseline data on the fetal hemodynamics and placental functions related to the cardiopulmonary bypass in the fetal lamb model. Material and Method: Eleven fetuses at 120 to 150 days of gestation were subjected to bypass via trans-sternal approach with a 12 G pulmonary arterial cannula and 14 to 18 F venous cannula for 30 minutes. All ewes received general anesthesia with ketamine. In all the fetuses, no anesthetic agents were used except muscle relaxant. Eight served as a group in which placenta was excluded from the extracorporeal circulation by clamping the umbilical cord during the bypass(the oxygenator group) and in the remaining three, the placenta worked as the only source of oxygen supply(the placenta group). Observations were made every 10 minute during a 30-minute bypass and 30-minute post bypass period. No prostaglandin inhibitors were used both in ewes and in fetuses. Result: Weights of the fetuses ranged from 1.9 to 5.2 kg. In the oxygenator group, means of arterial pressure, PaO2, atrial pressure, heart rate, and bypass flow rate ranged 69.8 to 82.6 mmHg, 201.7 to 220.9 mmHg, 4.1 to 4.3 mmHg, 169 to 182/min, and 140.3 to 164.0 ml/kg/min, respectively during bypass, but rapid deterioration of the fetal cardiac functions and the placental gas exchange was observed after the cessation of bypass. In the placenta group, means of arterial pressure decreased from 44.7 to 14.4 mmHg and means of PaCO2 increased from 61.9 to 129.6 mmHg during bypass. Flow rate was suboptimal(74.3 to 97.0 ml/kg/min) during bypass. All hearts fibrillated immediately after the discontinuation of bypass. Conclusion: In this study, the technical feasibility of fetal cardiopulmonary bypass was confirmed in the fetal lamb model. However, further studies with modifications of the bypass including an addition of prostaglandin inhibitor, an application of the total spinal anesthesia on the fetus, a creation of more concise bypass circuit, and a use of active pump are mandatory to improve the outcome.

  • PDF

Effects of Single Fetal Death on Mother and Live Co-twin in Twin Pregnancy (쌍태 임신에서 일측 태아의 자궁내 사망이 산모와 생존아에 미치는 영향)

  • Kim, So Youn;Chung, Hae Yul;Back, Hee Jo;Choi, Ic Sun;Cho, Chang Yee;Choi, Young Youn
    • Clinical and Experimental Pediatrics
    • /
    • v.45 no.12
    • /
    • pp.1512-1518
    • /
    • 2002
  • Purpose : Twins have a higher mortality and morbidity than singletons. Co-twin with one fetal death is particularly at risk. We investigated the neonatal outcome of live co-twins when one fetus had died after the 20th gestational week, and associated risk factors. Methods : A retrospective study was performed in fifteen cases of twin pregnancy with single intrauterine fetal deaths after the 20th gestational week during the period from January 1996 to December 2000 at Chonnam University Hospital. Results : Gestational age was $33.7{\pm}3.2weeks$, birth weight was $1,992{\pm}592g$. Interval between one fetal death being detected and the delivery of a live co-twin was $32.4{\pm}29.5days$. There were 11 cases(73.3%) of premature babies less than 37 gestational weeks. Main causes of preterm delivery were preterm labor and premature rupture of membranes. Hematologic findings suggesting disseminated intravascular coagulopathy(DIC) were not found in all mothers before delivery, and was not associated with DIC and encephalomalacia of the live co-twin. Perinatal outcome of fifteen live co-twins was as follows : six were normal(40%), three were DIC(20.0%), three were encephalomalacia(20.0%), one suffered intrauterine growth retardation, there was one case of twin to twin transfusion syndrome, and one of congenital heart disease(atrial septal defect with pulmonary stenosis). The occurrence of DIC and encephalomalacia in live co-twins was not related to placental chorionicity, birth weight, gestational week, and the interval between the detection one fetal death and the delivery of a live co-twin. Conclusion : We could not find any maternal hematologic problems in twin pregnancies complicated by one fetal death. Twenty percent of live co-twins showed DIC and encephalomalacia. However, its associated risk factors were not found. We need to investigate more closely the cases of live co-twins with one intrauterine fetal death.

Truncus Arteriosus, Type IV -one case report- (동맥간증 제 IV형 -1예 보고-)

  • 이종태
    • Journal of Chest Surgery
    • /
    • v.13 no.3
    • /
    • pp.243-249
    • /
    • 1980
  • Truncus ateriosus is one of the cyanotic congenital heart disease. The incidence is relatively uncommon, as 0.4% of totoal congenital heart disease. Embryologically the defect is due to a lack of partitioning of the embryonic truncus and conus during the first few weeks of fetal life. The ventricular septal defect is invariable present. A single arterial vessel arises from the heart and supplies blood to the aorta, the lung, and the coronary arteries. In 1949, collett and Edwards classified this defect according to anatomic variation to four major types, such as type I, II, III, and IV. Type IV is defined that pulmonary arteries are absent, and the pulmonary arterial supply arises from the descending thoracic aorta. This patients often have a continuous murmur head particularly well in the interscapular area. No effective surgical treatment is available. We have experienced one case of truncus arteriosus, type IV of Collett and Edwards in the Department of Thoracic and Cardiovascular Surgery, Kyungbook National University Hospital. This patient was 10 year-old girl. The chief complaints were cyanosis and dyspnea on exertion since birth. She was admitted at this hospital on April 16, 1980. The continous machinery murmur was heard loudest at the interscapular area. The chest X-ray films revealed cardiomegaly with an increase in pulmonaryvascular markings. The pulmonary secotr was significantly concave. No filling of pulmonary arteries noticed by the right ventriculogram. There was possible biventricular hypertrophy in EKG. The echocardiogram showed that the demension of the aortic root was larger than normal and minimal increase of the left ventricular internal dimension. The cardiac catheterization data was obtained by use of the great saphenus vein approach. The systolic pressure of the right ventricular outflow tract was 80 mmHg and was similar to that of the aorta. The oxygen saturation data revealed the evidence of the left to right shunt at the level of ventricular septum. The patient was operated and the diagnosis was confirmed as trucus arteriosus, type IV. No effective surgical interventins were performed.

  • PDF