• Title/Summary/Keyword: Ferromagnetic

Search Result 967, Processing Time 0.026 seconds

Model on the electro-magnetic characteristics of elastic ferromagnetic materials with vibrationg gap (탄성 고투자율 자성체의 공극진동에 따른 전자기 특성에 관한 모델)

  • 김대수;김왕곤;홍진웅
    • Electrical & Electronic Materials
    • /
    • v.9 no.9
    • /
    • pp.891-899
    • /
    • 1996
  • A model for predicting the characteristics of elastic ferromagnetic materials having a moving gap was presented. Based on the model parameters concerning behavior of material, such as the instantaneous field intensity, attractive force between the poles, length of gap, and the induced current/ emf in the circuit can be determined from the numerical integrations of the governing equations derived. From the results of the model it is found that when dc emf is imposed on the circuit the current sharply rise and fall for very short duration then stabilize at extremely low level which depends mainly on elasticity, permeabilities and ratio of resistivity. Subsequently output emf is shown stabilized at constant value which depends on the previous parameters as well as the resistivity ratio of primary to secondary circuit after sufficient progress of time.

  • PDF

Study of superconductor bearing stiffness according to shape of rotor (로터 형상에 따른 초전도 베어링 강성 변화)

  • 윤희중;한영희;한상철;정년호;김경진;박병삼;성태현
    • Proceedings of the Korea Institute of Applied Superconductivity and Cryogenics Conference
    • /
    • 2003.10a
    • /
    • pp.240-242
    • /
    • 2003
  • The properties of superconductor bearing are depend on shape of rotor, especially thickness of ferromagnetic shim between permanent magnets. The levitation forces and stiffness of superconductor bearings as the thickness of the ferromagnetic shim were calculated and measured, Frozen image model and difference of magnetization per unit volume of the superconductor were used to calculate stiffness for two models. The calculated values had similar trend with the measured one. From the results, an optimal design of the rotor was selected.

  • PDF

Optimization of Ferromagnetic Resonance Spectra Measuring Procedure for Accurate Gilbert Damping Parameter in Magnetic Thin Films Using a Vector Network Analyzer

  • Kim, D.H.;Kim, H.H.;You, Chun-Yeol;Kim, Hyung-Suk
    • Journal of Magnetics
    • /
    • v.16 no.3
    • /
    • pp.206-210
    • /
    • 2011
  • We optimize a vector network analyzer ferromagnetic resonance (VNA-FMR) measurement system to study spin dynamics and Gilbert damping parameters of thin ferromagnetic films. In order to obtain accurate damping parameters, careful determination of the susceptibility line-width is required. The measured S-parameters are converted into the corresponding susceptibility through a calibration processes. From the line-width measurements, we can successfully extract the saturation magnetizations and Gilbert damping parameters of 5-, 8-, and 10-nm thick $Ni_{81}Fe_{19}$ (Py) films.

Magnetic Behaviors of Isolated Fe-Co-Ni Nanoparticles in a Random Arrangement

  • Yang, Choong Jin;Kim, Kyung Soo;Wu, Jianmin
    • Journal of Magnetics
    • /
    • v.6 no.3
    • /
    • pp.94-100
    • /
    • 2001
  • Fe-Co-Ni particles with an average size of 45 and 135 nm are characterized in terms of magnetic phase transformation and magnetic properties at room temperature. BCC structure of Fe-Co-Ni spherical particles can be synthesized from Fe-Co-Ni-Al-Cu precursor films by heating at 600-80$0^{\circ}C$ for the phase separation of Fe-Co rich Fe-Co-Ni particles, followed by a post heating at $600^{\circ}C$ for 5 hours. The average size of nanoparticles was directly determined by the thickness of precursor films. Exchange interactive hysteresis was observed for the nano-composite (Fe-Co-Ni)+(Fe-Ni-Al) films resulting from the short exchange interface between ferromagnetic Fe-Co-Ni particles surrounded by almost papramagnetic Ni-Al-Fe matrix. Arraying the isolated Fe-Co-Ni nano-particles in a random arrangement on $Al_2O_3$substrate the particle assembly showed a behavior of dipole interactive ferromagnetic clusters depending on their volume and inter-particle distance.

  • PDF

Ferromagnetic resonance of Hensler $Ni_2$MnGa thin films

  • M. D. Huang;Lee, N. N.;Lee, Y. P.;J. Y. Rhee;J. Dubowik
    • Journal of the Korean Vacuum Society
    • /
    • v.12 no.S1
    • /
    • pp.116-119
    • /
    • 2003
  • $Ni_2$MnGa films, deposited on mica and glass substrates, were studied by ferromagnetic resonance (FMR) technology. The temperature-dependent resonance field was measured and a martensitic phase transformation (MT) was found between 310 and 340 K, exhibiting an abnormality on the curve. The easy axis is found to be in the film plane. The line width increases as a whole with decreasing temperature, which is discussed in terms of the motional narrowing mechanism. The resonance field was also measured as a function of orientation and the results were fitted, exhibiting a good consistence.

Fundamental study on cancer therapy by blocking newborn blood vessels by magnetic force control

  • KIRIMURA, Makoto;AKIYAMA, Yoko;NISHIJIMA, Shigehiro
    • Progress in Superconductivity and Cryogenics
    • /
    • v.20 no.2
    • /
    • pp.11-15
    • /
    • 2018
  • In this study, a cancer treatment by accumulating and aggregating ferromagnetic particles in newborn blood vessels was examined. It is necessary for this treatment to control dispersion-aggregation property of ferromagnetic particles. Ferromagnetic particles required in this method disperse at low magnetic field, aggregate at high magnetic field and maintain the aggregation even after removal of the magnetic field. In order to control the dispersion-aggregation property, the surface of magnetite particles was modified with higher fatty acids having different lengths. As a result, we succeeded to prepare propionic acid-modified magnetite particles that form irreversible aggregation by magnetic field. The model experiments simulating newborn blood vessels showed that these particles can block the flow by the magnetic field, and the blockage was maintained after removal of the magnetic field.

Magnetic Properties of Cu-doped AlN Semiconductor (AlN 반도체와 Cu의 도핑 농도에 대한 자성)

  • Kang, Byung-Sub;Lee, Haeng-Ki
    • Journal of the Semiconductor & Display Technology
    • /
    • v.9 no.3
    • /
    • pp.1-4
    • /
    • 2010
  • First-principles calculations based on spin density functional theory are performed to study the spin-resolved electronic properties of AlN doped with a Cu concentration of 6.25%-18.75%. The ferromagnetic state is more energetically favorable state than the antiferromagnetic state or the nonmagnetic state. For $Al_{0.9375}Cu_{0.0625}N$, a global magnetic moment of 1.26 mB per supercell, with a localized magnetic moment of 0.75 $m_B$ per Cu atom is found. The magnetic moment is reduced due to an increase in the number of Cu atoms occupying adjacent cation lattice position. For $Al_{0.8125}Cu_{0.1875}N$, the magnetism of the supercell disappears by the interaction of the neighboring Cu atoms. The nonmagnetic to ferromagnetic phase transition is found to occur at this Cu concentration. The range of concentrations that are spin-polarized should be restricted within very narrow.

ROOM TEMPERATURE FERROMAGNETISM IN TRANSITION METAL DOPED OXIDE SEMICONDUCTORS, $TiO_2$ and ZnO

  • Y. H. Jeong;S-J. Han;Park, J.H.
    • Proceedings of the Korean Magnestics Society Conference
    • /
    • 2003.06a
    • /
    • pp.17-17
    • /
    • 2003
  • Semiconductors with ferromagnetism at room temperature has been actively searched for in recent years; a prospect of devices using both charge and spin continuously gives impetus to the activities. Transition metal doped oxide materials have been of particular interest. Co substituted ZnO [1] and TiO$_2$ [2] thin films, for example, were reported to show ferromagnetic properties at room temperature. However, various studies do not seem to converge on a definite picture [3,4,5]. The issue is rather fundamental: whether a system shows ferromagnetic properties at all, and in case it does, whether the system possesses a close coupling between magnetism and transport properties. In this talk, we shall assess the current status of transition metal doped oxide materials as room temperature ferromagnetic semiconductors.

  • PDF

Assessment of Magnetic Resonance Image Quality For Ferromagnetic Artifact Generation: Comparison with 1.5T and 3.0T. (강자성 인공물 발생에 대한 자기공명영상 질 평가: 1.5T와 3.0T 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.193-199
    • /
    • 2018
  • In this research, 15 patients were diagnosed with 1.5T and 3.0T MRI instruments (Philips, Medical System, Achieva) to minize Ferromagnetic artifact and find the optimized Tesla. Based on the theory that the 3.0T, when compared to 1.5T, show relatively high signal-to-ratio(SNR), Scan time can be shortened or adjust the image resolution. However, when using the 3.0T MRI instruments, various artifact due to the magnetic field difference can degrade the diagnostic information. For the analysis condition, area of interest is set at the background of the T1, T2 sagittal image followed by evaluation of L3, L4, L5 SNR, length of 3 parts with Ferromagnetic artifact, and Histogram. The validity evaluation was performed by using the independent t test. As a result, for the SNR evaluation, mere difference in value was observed for L3 between 1.5T and 3.0T, while big differences were observed for both L4, and L5(p<0.05). Shorter length was observed for the 1.5T when observing 3 parts with Ferromagnetic artifact, thus we can conclude that 3.0T can provide more information on about peripheral tissue diagnostic information(p<0.05). Finally, 1.5T showed higher counts values for the Histogram evaluation(p<0.05). As a result, when we have compared the 1.5T and 3.0T with SNR, length of Ferromagnetic artifact, Histogram, we believe that using a Low Tesla for Spine MRI test can achieve the optimal image information for patients with disk operation like PLIF, etc. in the past.

Inverse Compensation of Hysteresis in Ferromagnetic Materials (강자성체의 히스테리시스 역 보상 모델)

  • 박영우;한광섭
    • Proceedings of the Korean Society of Precision Engineering Conference
    • /
    • 2004.10a
    • /
    • pp.1470-1474
    • /
    • 2004
  • This paper addresses the development of inverse compensation techniques for a class of ferromagnetic transducers including magnetostrictive actuators. In this work, hysteresis is modeled through the domain wall theory originally proposed by Jiles and Atherton[1]. This model is based on the quantification of the energy required to translate domain walls pinned at inclusions in the material with the magnetization at a given field level specified through the solution of an ordinary differential equation. A complementary differential equation is then employed to compute the inverse which can be used to compensate for hysteresis and nonlinear dynamics in control design.

  • PDF