Usefulness of Anteromedial Portal for Femoral Tunneling in Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술시 대퇴골 터널에 있어 전내측 삽입구의 유용성)

  • Kang, Min-Soo;Kim, In-Bo;Kim, Kyung-Taek
    • Journal of the Korean Arthroscopy Society
    • /
    • v.12 no.2
    • /
    • pp.118-124
    • /
    • 2008
  • Purpose: Recent development and advances in the arthroscopic surgical techniques for anterior cruciate ligament(ACL) reconstruction have led to the ideal location for more oblique anatomic point of the femur from 10 to 10:30 o'clock(in the right knee) and from 2 to 1:30 o'clock(in the left knee) in the frontal plane. This study was performed to compare the operative methods and the radiologic results of the femoral tunnels made through the tibial tunnel(trans-tibial approach) and the anteromedial portal. Materials and Methods: From January 2003 to May 2004, on hundred reconstructions of ACL were performed. Group I(the femoral tunnel made through the tibial tunnel) consisted of 50 cases and group I(the femoral tunnel made through the anteromedial portal) consisted of 50 cases. The operative methods and the radiographic results of the femoral tunnels were compared. Results: Femoral tunnel was made more easily at more oblique anatomic point in group II than in group I. In group II, better visual field was achieved at the angle of 100? flexion of the knee joint, the risks of the posterior cortical breakage and the tunnel-graft mismatching were reduced more, and the divergence of femoral interference screw from the radiograph decreased more than in group I(p<0.05). The angle between the femoral tunnel and the longitudinal axis of ACL increased in group II. Conclusion: Anteromedial portal technique was useful for femoral tunneling toward 10 to 10:30 o'clock(in the right knee) and 2 to 1:30 o'clock(in the left knee) in ACL reconstruction. Level of Evidence:Level III, case-control study.

  • PDF

Design of Femoral Tunnel Entrance to Operate Notchplasty (Notchplasty 시술을 위한 대퇴골 터널 입구 형상 설계)

  • Chung G.Y.;Kim K.T.;Lee T.H.;Ahn J.Y.;Han J.S.
    • Journal of Biomedical Engineering Research
    • /
    • v.21 no.3 s.61
    • /
    • pp.279-283
    • /
    • 2000
  • After ACL reconstruction. abrasion or wear of graft appeared frequently because of contact stresses between femoral tunnel and ACL. To minimize these problems. optimal shape of femoral tunnel is necessary. In this study. we evaluate friction force by degree of wear due to abrasion of soft tissue and develop 3-dimensional FEM model using ANSYS 5.5.1 version to analyze stress growths between femoral tunnel and ACL, We conclude that femoral tunnel angle must be slacked parallel to tunnel direction to minimize contact stress.

  • PDF

Radiographic Evaluation of Femoral Tunnel Placement During ACL Reconstruction (전방 십자 인대 재건술시 대퇴 터널의 위치에 대한 방사선학적 평가)

  • Chung, Hyun Kee;Choi, Choong Hyeok;Lee, Joong Hak
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.80-84
    • /
    • 1998
  • The isometric position for the graft is important in the anterior cruciate ligament reconstruction surgery. It is well known that the femoral position is more critical than tibial side. But, there is few deciding method of proper graft position after the anterior cruciate ligament reconstruction surgery. So we planned to evaluate the ideal femoral isometric position with 6 adult cadavaric femurs and exact radiographs. After the insertion of femoral interference screw on ideal isometric position, we obtained roentgenograms of true lateral view and 10, 20, 30, 45 degree internal and external rotation views. Then we measured the shortest distance from the posterior cortical margin of lateral femoral condyle to posterior border of interference screw on the radiographs. We also measured true distance between posterior cortical margin of lateral femoral condyle to the posterior margin of femoral tunnel after cutting of distal femur. Based on this study, we could not determine the permissible rotation degree of radiographs. But we concluded that if the distance between posterior cortical margin of lateral femoral condyle and posterior border of interference screw ranges 4.5-6.5mm on the lateral view, the femoral position is considered as a relatively ideal isometric good position.

  • PDF

Comparision of Trans-Tibial and Anteromedial Portal Approach in Femoral Tunneling of Anterior Cruciate Ligament Reconstruction (전방십자인대 재건술의 대퇴골 터널 굴착시 경경골 접근법과 전내측통로 접근법의 비교)

  • Sohn, Sung-Keun;Chang, Yun-Suk;Chung, ll-Kwon;Kim, Kyung-Taek
    • Journal of the Korean Arthroscopy Society
    • /
    • v.8 no.2
    • /
    • pp.75-81
    • /
    • 2004
  • Purpose: Recent development and advances in arthroscopic surgical techniques for Anterior Cruciate Ligament(ACL) reconstruction have led to the ideal location for the etric point from 10 o'clock (in right knee) and 13:30 (in left knee) to 10:30 (in right knee) and 14 o'clock (in left knee) in the frontal plane. This study was performed to compare operative methods and the radiologic results of femoral tunnels made through the tibial tunnel(trans-tibial approach) and the anteromedial portal. Material and Methods: From January 2003 to May 2004, one-hundred reconstructions of anterior cruciate ligament were performed. Group I (femoral tunnel through tibial tunnel) was composed of 50 cases and group ll (femoral tunnel through anteromedial portal) was consisted of 50 cases. The study was performed to compare the radiographic results of femoral tunnels made through the tibial tunnel and the anteromedial portal and operative methods. Results: In operative methods at Group II, femoral tunnel was made more easily at isometric point than Group I, a good visual field was achived because 100$^{\circ}$ flxion of knee, they can be reduced risk of posterior cortical breakage and tunnel-graft mismatching and decreased divergence of femoral interference screw in radiology (P<0.05). The angle between femoral tunnel and longitudinal axis of ACL wae increased at Group ll. Conclusion: Aanteromedial portal technique was more useful in ACL reconstruction for femoral tunnel toward 10 o'clock to10:30(in right) or 1:30 to 2 o'clock(in left).

  • PDF

ACL reconstruction with autologous hamstring tendon - Short term clinical result using new femoral suspensory fixation device 'Cross Pin' and graft tensioner for maintaining a constant tension- (자가 슬괵건을 이용한 전방 십자 인대 재건술 - 새로운 대퇴부 현수고정법인 Cross Pin과 일정한 긴장력 유지를 위한 Graft Tensioner 사용의 단기 추시 결과 -)

  • Seo, Seung-Suk;Kim, Chang-Wan;Kim, Jin-Seok;Choi, Sang-Yeong
    • Journal of Korean Orthopaedic Sports Medicine
    • /
    • v.10 no.1
    • /
    • pp.27-34
    • /
    • 2011
  • Purpose: To evaluate the short term clinical result of ACL reconstruction with autologous hamstring tendon using Cross pin and Graft Tensioner and to seek way to resolve the experienced technical problems. Materials and Methods: From January 2008 to March 2009, 35 patients who had been treated arthroscopic ACL reconstruction were enrolled. The femoral side of ACL graft was fixed with Cross pin. The tibial side of graft was fixed with Intrafix and post-tie. The graft was tensioned with Graft Tensioner at 80N. We analyzed the clinical, radiographic results and complications. Results: IKDC subjective score and Lysholm score improved to 89.1 and 91.4 points. Also, Pivot shift test and One-leg hop test showed good results postoperatively. Side to side difference using KT-1000 arthrometer and Telos stress radiography improved compared with normal limb to $2.8{\pm}1.6$ mm and $2.6{\pm}1.3$ mm, respectively. The femoral tunnel enlarged to $2.3{\pm}1.1$ mm. Soft tissue irritation and femoral tunnel-graft harness length mismatch, femoral tunnel-cross pin tunnel mismatch were happened as peri-operative complications. Conclusion: Using of Cross pin and Graft Tensioner for ACL reconstruction with hamstring tendon is one of the good method for obtaining stability in short-term clinical result. But to reduce femoral tunnel-cross pin mismatch, it needs to shorten femoral bone tunnel and to create cross pin tunnel as vertical as possible. And to reduce femoral tunnel-graft harness mismatch, it needs to advance position rod further 3 mm when to create femoral tunnel.

  • PDF

Overview of the PCL Reconstruction (후방 십자 인대 손상 치료의 개관(over view))

  • Jung, Young Bok
    • Journal of the Korean Arthroscopy Society
    • /
    • v.2 no.1
    • /
    • pp.1-3
    • /
    • 1998
  • The PCL reconstruction in chronic isolate PCL reconstruction was still controversy. 1) In isolate PCL deficient knee, functionally not so bad as like ACL deficient knee. 2) The result of the PCL reconstruction was not as good as ACL reconstruction. Therefore, isolate PCL injuries has been treated as nonoperatively. Hey Grovere, who was the first to attempt an intra-articular reconstruction of the PCL, utilized the semi-tendinous tendon other static procedures have been described in only a few cases with very limited follow-up. Dynamic procedures utilizing the medial head of the gastrocnemius has been reported by Hugston and Degenhardt, Kennedy and Grainger, and Insall and Hood. These procedures did not improve static stability. Dr Clancy, who was introduce the use of BPTB for the PCL reconstruction transtibial and femoral tunnel. From 1995, untill early 1990 PCL reconstruction was done as tend as placement of the isometric point. Physiometic placement of Anatomical placement of the femoral tunnel in PCL reconstruction were introduced in 1995. Tibial Inlay Technique was reported by Dr Berg in 1995. The main advantage of the tibial Inlay Technique was to avoid fraying of the graft at the posterior tibial tunnel orifice. In complete PCL ruptured and severely posterior unstable knee, dual femoral tunnel technique will be to get better result than one bundle technique. To achieve restoration of normal posterior laxity, it is critical to address the posterior as well as the posterolateral structures. Futher research is necessary to evaluate new surgical approches such as double-bundle reconstructions and tibial inlay techniques as well as improved techniques for capsular and collateral ligament injuries.

  • PDF

ACL Reconstruction using Transtibial Femoral Tunnel at 10 or 2 O'clock Position - Technical Note - (10시 혹은 2시 방향의 경경골 대퇴 터널을 이용한 전방 십자 인대 재건술 - 수술 수기 -)

  • Cho, Sung-Do;Ko, Sang-Hun;Park, Mun-Soo;Jung, Kwang-Hwan;Cha, Jae-Ryong;Gwak, Chang-Youl;Kim, Sang-Woo
    • Journal of the Korean Arthroscopy Society
    • /
    • v.10 no.2
    • /
    • pp.209-213
    • /
    • 2006
  • Purpose: Conventional transtibial approach for the anterior cruciate ligament (ACL) reconstruction tended to place the femoral tunnel in too vertical position (11 or 1 o'clock), which could provide the postoperative anteroposterior (AP) stability but not provided the rotational stability. Therefore we present a surgical technique to make the transtibial femoral tunnel at 10 or 2 o'clock position. Surgical approach: To make a transtibial femoral tunnel at the 10 or 2 o'clock position, the direction and position of the tibial drill guide was important. We set the tibial drill guide at $40{\sim}45$ degrees and the intraarticular guide tip was 1 mm anterior and medial to the conventional site. The starting point for the guide pin on the proximal tibia was proximal to the pes anserinus and anterior to the medial collateral ligament. The tibial tunnel was initially drilled 1mm less than the diameter of the graft. Then femoral offset guide could be easily placed at 10 or 2 o'clock position through the tibial tunnel. The tibial tunnel and the femoral tunnel of 30 mm in length were made with the reamer that was same size with the graft. Conclusion: We report a surgical technique to create a transtibial femoral tunnel at 10 or 2 o'clock position in ACL reconstruction to provide the rotational stability as well as the AP stability.

  • PDF

Femoral Tunnel Drilling Techniques in Anterior Cruciate Ligament Reconstruction (전방십자인대 대퇴터널 형성을 위한 방법들과 각각의 장단점)

  • Lee, Sang Hak;Lee, Myeong Gu
    • Journal of the Korean Orthopaedic Association
    • /
    • v.55 no.4
    • /
    • pp.311-317
    • /
    • 2020
  • The most recent concept in anterior cruciate ligament reconstruction is an anatomical single bundle anterior cruciate ligament reconstruction. For an anatomical anterior cruciate ligament reconstruction, the tibial tunnel is made anterior than before, and the femoral tunnel is made in a lower and oblique direction compared to the classical method using the transtibial technique. The anteromedial portal technique, outside-in technique, and modified transtibial technique have been performed to produce femoral tunnels with anatomical positions. Each method has different advantages and disadvantages and is chosen based on the operator's preferences, experience, instruments, and implants.

Failure of Cross-Pin Femoral Fixation after Anterior Cruciate Ligament Reconstruction - A Case Report - (전방십자인대 재건술후 대퇴골 경골핀 고정의 실패 - 증례보고 -)

  • Lee Kee-Byoung;Kwon Duck-Joo;Ji Yong-Nam
    • Journal of the Korean Arthroscopy Society
    • /
    • v.7 no.1
    • /
    • pp.92-95
    • /
    • 2003
  • A 34-year-old man with ACL total rupture due to slip down injury, had received ACL reconstruction using autogenous hamstrings tendon with cross-pin femoral fixation. Postoperative course was as usual. But postoperative 3 months later, he complained posterolateral knee pain, recurrent effusion and mild instability. He was managed repeatitive aspiration and nonsteroid antiinflammatory drugs but was failed to relieve symptoms & signs. In CT scans, perforation of posteromedial femoral cortex of lateral femoral condyle was found. In second look arthroscopy, two pieces of broken femoral cross pin were found in between tibiofemoral Joint which was badly injured cartilage. We considered malposition of pins was the main cause of failure. We propose that femoral tunnel must be made more acute angle and femoral cross-pin guide must be positioned more external rotation 10-20 degree than transepicondylar axis made confirm the cross-pin tunnel position in order to avoid posterior cortex perforation and early failure.

  • PDF